Drinking Water Supply and Sanitation Local Bodies Closing in 30 days TDR #58434864

Tender For Operation And Maintenance Of The 2 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12B)

Issued by Local Bodies · Tenkasi, Tamil Nadu
Tender Value
12.70 Crore
Estimated cost
Bid Submission
07 Dec 2026
30 days left
EMD
9.53 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tenkasi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Operation And Maintenance Of The 2 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12B)

BOQ

Name of Work:- Operation and maintenance of the 2 Nos of CWSS in Tenkasi District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 12B)
Sl. No. Item Description
1Operation and maintenance of the 2 Nos of CWSS in Tenkasi District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 12B)
2CWSS TO Vasudevanallur, Rayagiri, Sivagiri, Alangulam TPs and 78 Other habitations in Tenkasi District and Bulk provision to Srivilliputhur Municipality and way side habitations in Virudhunagar District
3CWSS TO Kadayanallur, Puliyankudi Municipalities, Surandai, Sundarapandiyapuram, Sambavarvadakarai Town Panchayats and 114 Way side habitations in Tenkasi District
4Total Basic Value
5Add GST @18% on Basic Value
62.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
7Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 12.00 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 1080.00 ML (12*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
8Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
9PSC Pipes of various sizes
10Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
11500 mm dia PSC Pipe
12600 mm dia PSC Pipe
13Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
14500 mm dia PSC Pipe
15600 mm dia PSC Pipe
16Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
17500 mm dia PSC Pipe
18600 mm dia PSC Pipe
19Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
20500 mm dia PSC Pipe
21600 mm dia PSC Pipe
22Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
23PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
24Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
25700 mm dia BWSC Pipe Various Classes
26200 mm MS Pipe
27500 mm MS Pipe
28600 mm MS Pipe
29Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
30700 mm dia BWSC Pipe Various Classes
31200 mm MS Pipe
32500 mm MS Pipe
33600 mm MS Pipe
34Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
35700 mm dia BWSC Pipe Various Classes
36200 mm MS Pipe
37500 mm MS Pipe
38600 mm MS Pipe
39Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
40700 mm dia BWSC Pipe Various Classes
41200 mm MS Pipe
42500 mm MS Pipe
43600 mm MS Pipe
44Supply and Delivery of MS specials as per IS 7322-1985 with inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
45700 mm dia BWSC Pipe Various Classes
46200mm MS pipe
47200mm Machine end
48500mm MS pipe
49500mm Machine end
50600mm MS pipe
51600mm Machine end
52Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
53700 mm dia BWSC Pipe Various Classes
54200 mm MS Pipe
55500 mm MS Pipe
56600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
57Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
58For PVC Pipes of various sizes
59For PSC Pipes of various sizes
60Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
6150mm PVC 6 KSC
6263mm PVC 4 KSC
6375mm PVC 4 KSC
6490mm PVC 4 KSC
65110mm PVC 4KSC
66140mm PVC 4KSC
67160mm PVC 4KSC
68200mm PVC 4KSC
69Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
70508 mm x 5 mm thick MS PIPE
71610 mm x 5.8 mm thick MS PIPE
72Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
7350mm PVC Coupler Fabricated 6 KSC
7463mm PVC Coupler Fabricated 4 KSC
7575mm PVC Coupler Fabricated 4 KSC
7690mm PVC Coupler Fabricated 4 KSC
77110mm PVC Coupler Fabricated 4 KSC
78140mm PVC Coupler Fabricated 4 KSC
79160mm PVC Coupler Fabricated 4 KSC
80200mm PVC Coupler Fabricated 4 KSC
81Supply and delivery of MJ Collers as directed by TWAD Board officers
82500 mm dia PSC Pipe
83600 mm dia PSC Pipe
84Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
8550mm PVC 6KSC
8663mm PVC 4KSC
8775mm PVC 4KSC
8890mm PVC 4 KSC
89110mm PVC 4KSC
90140mm PVC 4KSC
91160mm PVC 4KSC
92200mm PVC 4KSC
93500 mm PSC Pipes
94600 mm PSC Pipes
95Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
9650 mm GI Pipe
9765 mm GI Pipe
9880 mm GI Pipe
99100 mm GI Pipe
100Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
10150 mm GI Pipe
10265 mm GI Pipe
10380 mm GI Pipe
104100 mm GI Pipe
105Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
10650 mm GI Pipe
10765 mm GI Pipe
10880 mm GI Pipe
109100 mm GI Pipe
110Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
11150 mm GI Pipe
11265 mm GI Pipe
11380 mm GI Pipe
114100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
115Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Mukkudal
116Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 982 LPM X 16 M ) including cost of all material ,conveyance, labour charges for removing and re-erection of Submersible pumpset at Head Works, Mukkudal Infiltration Well
117Rewinding of motor and repair works to 100 HP centrifugal HSC Motor ( 5882 lpm x50 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works, Mukkudal Pump Room
118Repair and reconditioning works in 100 HP HSC centrifugal Pump ( 5882 x 50 m Head ) including cost of all material exluding Bronze impeller ,conveyance , labour charges for removing and re-erection of centrifugal HSC Pump at Head Works, Mukkudal Pump Room -
119Rewinding of motor and reconditioning pump and repair works to 1 HP centrifugal Monobloc Pump set (20 LPM x 41m Head) including cost of all material, conveyance, labour charges for removing and re-erection of Monobloc Pump set at Mukkudal. SUMP AT KASINATHAPURAM
120Repair and reconditioning works in 120 HP Vertical turbine Pump ( 5818 lpm x 61 m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Kalingapatti Pump Room
121Rewinding of 120 HP Vertical turbine motor ( 5818 lpm x61 m Head ) including cost ofall materials (excluding SS Hollow/solid shaft), conveyance, labour charges for removing andre-erection of Vertical Turbine Motors etc., complete and as directed by the TWAD Boardofficers.
122Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set 128 lpm x 41m hea m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room ALANGULAM SUMP
123Rewinding of motor and reconditioning pump and repair works to 15HP Submercible Pump set (845 lpm x 38 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Alangulam Pump Room
124Rewinding of motor and reconditioning pump and repair works to 1HP Submercible Pump set (44 lpm x49 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Alangulam Pump Room Kalingapatty sump
125Rewinding of motor works in 120 HP Vertical turbine motor (5374 lpm x64m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room.
126Repair and reconditioning works in 120 HP Vertical turbine Pump (5374 lpm x64m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room. Sendamaram Sump
127Rewinding of motor works in 100 HP Vertical turbine motor (5374 lpm x 47m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room
128Repair and reconditioning works in 100 HP Vertical turbine Pump (5374 lpm x 47m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room.
129Rewinding of motor and reconditioning pump and repair works to 2HP submersible Pump set (170lpm x18m) including cost of all material ,conveyance ,labour charges for removing and re-erection Pump set to Sendamaram.
130Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (230lpm x 31m) including cost of all material ,conveyance ,labour charges for removing and re-erection Pump set to veerasigamani. Vellalankottai sump
131Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 295 lpm x21m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vellalankottai-
132Rewinding of motor and reconditioning pump and repair works to 15 HP Submersible Pump set ( 1212 lpm x27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vasudevanallur NARANAPURAM SUMP
133Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x268 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Naranapuram- VADAMALAPURAM SUMP
134Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 52 lpm x18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadamalapuram THIRUMALAPURAM SUMP
135Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 331 lpm x23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalapuram RAYAGIRI SUMP
136Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 208 lpm x35 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Viswanathaperi
137Rewinding of motor and reconditioning pump and repair works to 25 HP Submersible Pump set ( 1087 lpm x 50 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Sivagiri RTP
138Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 709 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Rayagiri RTP
139Rewinding of motor and reconditioning pump and repair works to 1HP Submersible Pump set (68lpm x 24m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Refugee colony
140Rewinding of motor and reconditioning pump and repair works to 1.50 HP Submersible Pump set ( 112 lpm x 19m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Muthukudi
141Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 150lpm x 26m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Samusigapuram
142Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 280lpm x 23m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Samusigapuram
143Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 150 lpm x 33 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ashilapuram
144Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 308 lpm x 30m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kothankulam
145Attending cable fault by replacing the cable 6 Nos of IW
146Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.7098 for following Wells submersible motor to main panel board.35 sqmm Aluminum armoured cable for 7 Nos of IW Including standby pumpset.
147Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.35 sqmm Aluminum armoured cable for 7 Nos of IW Including standby pumpset
148Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. 35 sq.mm cable for 7 Nos.of infiltration wells
149Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset.
150Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. 50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
151Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers Jointing of 50 sq.mm cable for 2 Nos.of infiltration wells
152Replacement of 32-400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers.
1533 Pole MCCB
15432 Amps
15563 Amps
156100 Amps
157250 Amps
158400 Amps
159Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
1609 Amps\440V
16112 Amps\440V
16218 Amps\440V
16325 Amps\440V
16432 Amps\440V
16540 Amps\440V
16645 Amps\440V
16770 Amps\440V
16895 Amps\440V
169225 Amps\440V
170Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
171Upto 5A
172Upto 5A-10A
173Upto 10A-20A
174Upto 20A-30A
175Upto 30A-50A
176Upto 50A-75A
177Upto 75A-110A
178Upto 200A-300A
179Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
180Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply
181Attending Major Repair works to 315 KVA Transformer At MUKKUDAL HEAD WORKS
182Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
183Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
184Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
185Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
186Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
187Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
188Supply and delivery of 433KV LV Bushing copper rod to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
189Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
190Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
191Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
192Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
193Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
194Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
195Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
196Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
197Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
198Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
199Attending Major Repair works to 250KVA Transformer At Kasinathapuram, Kalingapatti & Senthamaram Booster Station
200Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
201Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
202Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
203Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
204Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
205Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
206Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
207Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
208Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
209Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
210Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
211Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
212Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
213Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
214Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
215Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
216Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
217Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
218For 1 HP Starter
219For 3 HP Starter
220For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
221Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
222600mm sluice valve
223500 mm CI Sluice valve
224450 mm CI Sluice valve
225400 mm CI Sluice valve
226250 mm CI Scour valve
227350 mm CI Sluice valve
228300 mm CI Sluice valve
229300 mm CI NRV valve
230200 mm CI NRV valve
231150 mm CI Sluice valve
232150 mm CI NRV valve
233100 mm CI Sluice valve
234Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
23550 mm Gate valve
23665 mm Gate valve
23780 mm Gate valve
238100 mm Gate valve
239Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
240Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
241Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
242Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
243Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
2444.00 LL capacity of sump @ head works Mukkudal
2458.00 LL capacity of sump @ Kasinathapuam
2467.00 LL capacity of sump @ , kalinkapatty, Sendamaram
2471.50 LL capacity of sump @ Rayagiri
2481.00 LL capacity of sump @ Alangulam, velllankottai
2490.30 LL capacity of sump @ Gudalure and Thirumalapuram
2500.15 LL capacity of sump @ Vadamalapuram
2510.10 LL capacity of sump @ Naranapuram
2524.00 LL capacity of sump @ Srivilliputhur
2531.50 LL capacity of sump @ Samsigapuram
2541.00. LL capacity of sump @ Kothankulam
2550.30 LL capacity of sump @ Refuge colony
2560.60 LL capacity of sump @ Asilapuram and Muthukudi For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
257Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 12.00 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 4380.00 ML (12*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
258Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
259PSC Pipes of various sizes
260Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
261500 mm dia PSC Pipe
262600 mm dia PSC Pipe
263Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
264500 mm dia PSC Pipe
265600 mm dia PSC Pipe
266Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
267500 mm dia PSC Pipe
268600 mm dia PSC Pipe
269Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
270500 mm dia PSC Pipe
271600 mm dia PSC Pipe
272Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
273PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
274Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
275700 mm dia BWSC Pipe Various Classes
276200 mm MS Pipe
277500 mm MS Pipe
278600 mm MS Pipe
279Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
280700 mm dia BWSC Pipe Various Classes
281200 mm MS Pipe
282500 mm MS Pipe
283600 mm MS Pipe
284Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
285700 mm dia BWSC Pipe Various Classes
286200 mm MS Pipe
287500 mm MS Pipe
288600 mm MS Pipe
289Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
290700 mm dia BWSC Pipe Various Classes
291200 mm MS Pipe
292500 mm MS Pipe
293600 mm MS Pipe
294Supply and Delivery of MS specials as per IS 7322-1985 with inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
295700 mm dia BWSC Pipe Various Classes
296200mm MS pipe
297200mm Machine end
298500mm MS pipe
299500mm Machine end
300600mm MS pipe
301600mm Machine end
302Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
303700 mm dia BWSC Pipe Various Classes
304200 mm MS Pipe
305500 mm MS Pipe
306600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
307Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
308For PVC Pipes of various sizes
309For PSC Pipes of various sizes
310Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
31150mm PVC 6 KSC
31263mm PVC 4 KSC
31375mm PVC 4 KSC
31490mm PVC 4 KSC
315110mm PVC 4KSC
316140mm PVC 4KSC
317160mm PVC 4KSC
318200mm PVC 4KSC
319Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
320508 mm x 5 mm thick MS PIPE
321610 mm x 5.8 mm thick MS PIPE
322Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
32350mm PVC Coupler Fabricated 6 KSC
32463mm PVC Coupler Fabricated 4 KSC
32575mm PVC Coupler Fabricated 4 KSC
32690mm PVC Coupler Fabricated 4 KSC
327110mm PVC Coupler Fabricated 4 KSC
328140mm PVC Coupler Fabricated 4 KSC
329160mm PVC Coupler Fabricated 4 KSC
330200mm PVC Coupler Fabricated 4 KSC
331Supply and delivery of MJ Collers as directed by TWAD Board officers
332500 mm dia PSC Pipe
333600 mm dia PSC Pipe
334Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
33550mm PVC 6KSC
33663mm PVC 4KSC
33775mm PVC 4KSC
33890mm PVC 4 KSC
339110mm PVC 4KSC
340140mm PVC 4KSC
341160mm PVC 4KSC
342200mm PVC 4KSC
343500 mm PSC Pipes
344600 mm PSC Pipes
345Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
34650 mm GI Pipe
34765 mm GI Pipe
34880 mm GI Pipe
349100 mm GI Pipe
350Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
35150 mm GI Pipe
35265 mm GI Pipe
35380 mm GI Pipe
354100 mm GI Pipe
355Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
35650 mm GI Pipe
35765 mm GI Pipe
35880 mm GI Pipe
359100 mm GI Pipe
360Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
36150 mm GI Pipe
36265 mm GI Pipe
36380 mm GI Pipe
364100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
365Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Mukkudal
366Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 982 LPM X 16 M ) including cost of all material ,conveyance, labour charges for removing and re-erection of Submersible pumpset at Head Works, Mukkudal Infiltration Well
367Rewinding of motor and repair works to 100 HP centrifugal HSC Motor ( 5882 lpm x50 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works, Mukkudal Pump Room
368Repair and reconditioning works in 100 HP HSC centrifugal Pump ( 5882 x 50 m Head ) including cost of all material exluding Bronze impeller ,conveyance , labour charges for removing and re-erection of centrifugal HSC Pump at Head Works, Mukkudal Pump Room -
369Rewinding of motor and reconditioning pump and repair works to 1 HP centrifugal Monobloc Pump set (20 LPM x 41m Head) including cost of all material, conveyance, labour charges for removing and re-erection of Monobloc Pump set at Mukkudal. SUMP AT KASINATHAPURAM
370Repair and reconditioning works in 120 HP Vertical turbine Pump ( 5818 lpm x 61 m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Kalingapatti Pump Room
371Rewinding of 120 HP Vertical turbine motor ( 5818 lpm x61 m Head ) including cost ofall materials (excluding SS Hollow/solid shaft), conveyance, labour charges for removing andre-erection of Vertical Turbine Motors etc., complete and as directed by the TWAD Boardofficers.
372Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set 128 lpm x 41m hea m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room ALANGULAM SUMP
373Rewinding of motor and reconditioning pump and repair works to 15HP Submercible Pump set (845 lpm x 38 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Alangulam Pump Room
374Rewinding of motor and reconditioning pump and repair works to 1HP Submercible Pump set (44 lpm x49 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Alangulam Pump Room Kalingapatty sump
375Rewinding of motor works in 120 HP Vertical turbine motor (5374 lpm x64m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room.
376Repair and reconditioning works in 120 HP Vertical turbine Pump (5374 lpm x64m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room. Sendamaram Sump
377Rewinding of motor works in 100 HP Vertical turbine motor (5374 lpm x 47m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room
378Repair and reconditioning works in 100 HP Vertical turbine Pump (5374 lpm x 47m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room.
379Rewinding of motor and reconditioning pump and repair works to 2HP submersible Pump set (170lpm x18m) including cost of all material ,conveyance ,labour charges for removing and re-erection Pump set to Sendamaram.
380Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (230lpm x 31m) including cost of all material ,conveyance ,labour charges for removing and re-erection Pump set to veerasigamani. Vellalankottai sump
381Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 295 lpm x21m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vellalankottai-
382Rewinding of motor and reconditioning pump and repair works to 15 HP Submersible Pump set ( 1212 lpm x27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vasudevanallur NARANAPURAM SUMP
383Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x268 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Naranapuram- VADAMALAPURAM SUMP
384Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 52 lpm x18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadamalapuram THIRUMALAPURAM SUMP
385Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 331 lpm x23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalapuram RAYAGIRI SUMP
386Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 208 lpm x35 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Viswanathaperi
387Rewinding of motor and reconditioning pump and repair works to 25 HP Submersible Pump set ( 1087 lpm x 50 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Sivagiri RTP
388Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 709 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Rayagiri RTP
389Rewinding of motor and reconditioning pump and repair works to 1HP Submersible Pump set (68lpm x 24m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Refugee colony
390Rewinding of motor and reconditioning pump and repair works to 1.50 HP Submersible Pump set ( 112 lpm x 19m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Muthukudi
391Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 150lpm x 26m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Samusigapuram
392Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 280lpm x 23m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Samusigapuram
393Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 150 lpm x 33 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ashilapuram
394Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 308 lpm x 30m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kothankulam
395Attending cable fault by replacing the cable 6 Nos of IW
396Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.7098 for following Wells submersible motor to main panel board.35 sqmm Aluminum armoured cable for 7 Nos of IW Including standby pumpset.
397Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.35 sqmm Aluminum armoured cable for 7 Nos of IW Including standby pumpset
398Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. 35 sq.mm cable for 7 Nos.of infiltration wells
399Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset.
400Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. 50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
401Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers Jointing of 50 sq.mm cable for 2 Nos.of infiltration wells
402Replacement of 32-400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers.
4033 Pole MCCB
40432 Amps
40563 Amps
406100 Amps
407250 Amps
408400 Amps
409Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
4109 Amps\440V
41112 Amps\440V
41218 Amps\440V
41325 Amps\440V
41432 Amps\440V
41540 Amps\440V
41645 Amps\440V
41770 Amps\440V
41895 Amps\440V
419225 Amps\440V
420Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
421Upto 5A
422Upto 5A-10A
423Upto 10A-20A
424Upto 20A-30A
425Upto 30A-50A
426Upto 50A-75A
427Upto 75A-110A
428Upto 200A-300A
429Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
430Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply
431Attending Major Repair works to 250KVA Transformer At MUKKUDAL HEAD WORKS
432Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
433Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
434Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
435Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
436Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
437Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
438Supply and delivery of 433KV LV Bushing copper rod to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
439Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
440Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
441Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
442Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
443Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
444Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
445Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
446Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
447Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
448Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
449Attending Major Repair works to 250KVA Transformer At Kasinathapuram, Kalingapatti & Senthamaram Booster Station
450Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
451Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
452Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
453Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
454Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
455Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
456Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
457Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
458Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
459Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
460Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
461Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
462Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
463Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
464Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
465Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
466Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
467Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
468For 1 HP Starter
469For 3 HP Starter
470For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
471Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
472600mm sluice valve
473500 mm CI Sluice valve
474450 mm CI Sluice valve
475400 mm CI Sluice valve
476250 mm CI Scour valve
477350 mm CI Sluice valve
478300 mm CI Sluice valve
479300 mm CI NRV valve
480200 mm CI NRV valve
481150 mm CI Sluice valve
482150 mm CI NRV valve
483100 mm CI Sluice valve
484Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
48550 mm Gate valve
48665 mm Gate valve
48780 mm Gate valve
488100 mm Gate valve
489Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
490Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
491Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
492Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
493Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
4944.00 LL capacity of sump @ head works Mukkudal
4958.00 LL capacity of sump @ Kasinathapuam
4967.00 LL capacity of sump @ , kalinkapatty, Sendamaram
4971.50 LL capacity of sump @ Rayagiri
4981.00 LL capacity of sump @ Alangulam, velllankottai
4990.30 LL capacity of sump @ Gudalure and Thirumalapuram
5000.15 LL capacity of sump @ Vadamalapuram
5010.10 LL capacity of sump @ Naranapuram
5024.00 LL capacity of sump @ Srivilliputhur
5031.50 LL capacity of sump @ Samsigapuram
5041.00. LL capacity of sump @ Kothankulam
5050.30 LL capacity of sump @ Refuge colony
5060.60 LL capacity of sump @ Asilapuram and Muthukudi For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
507Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 12.00 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 4380.00 ML (12*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
508Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
509PSC Pipes of various sizes
510Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
511500 mm dia PSC Pipe
512600 mm dia PSC Pipe
513Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
514500 mm dia PSC Pipe
515600 mm dia PSC Pipe
516Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
517500 mm dia PSC Pipe
518600 mm dia PSC Pipe
519Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
520500 mm dia PSC Pipe
521600 mm dia PSC Pipe
522Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
523PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
524Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
525700 mm dia BWSC Pipe Various Classes
526200 mm MS Pipe
527500 mm MS Pipe
528600 mm MS Pipe
529Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
530700 mm dia BWSC Pipe Various Classes
531200 mm MS Pipe
532500 mm MS Pipe
533600 mm MS Pipe
534Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
535700 mm dia BWSC Pipe Various Classes
536200 mm MS Pipe
537500 mm MS Pipe
538600 mm MS Pipe
539Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
540700 mm dia BWSC Pipe Various Classes
541200 mm MS Pipe
542500 mm MS Pipe
543600 mm MS Pipe
544Supply and Delivery of MS specials as per IS 7322-1985 with inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
545700 mm dia BWSC Pipe Various Classes
546200mm MS pipe
547200mm Machine end
548500mm MS pipe
549500mm Machine end
550600mm MS pipe
551600mm Machine end
552Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
553700 mm dia BWSC Pipe Various Classes
554200 mm MS Pipe
555500 mm MS Pipe
556600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
557Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
558For PVC Pipes of various sizes
559For PSC Pipes of various sizes
560Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
56150mm PVC 6 KSC
56263mm PVC 4 KSC
56375mm PVC 4 KSC
56490mm PVC 4 KSC
565110mm PVC 4KSC
566140mm PVC 4KSC
567160mm PVC 4KSC
568200mm PVC 4KSC
569Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
570508 mm x 5 mm thick MS PIPE
571610 mm x 5.8 mm thick MS PIPE
572Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
57350mm PVC Coupler Fabricated 6 KSC
57463mm PVC Coupler Fabricated 4 KSC
57575mm PVC Coupler Fabricated 4 KSC
57690mm PVC Coupler Fabricated 4 KSC
577110mm PVC Coupler Fabricated 4 KSC
578140mm PVC Coupler Fabricated 4 KSC
579160mm PVC Coupler Fabricated 4 KSC
580200mm PVC Coupler Fabricated 4 KSC
581Supply and delivery of MJ Collers as directed by TWAD Board officers
582500 mm dia PSC Pipe
583600 mm dia PSC Pipe
584Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
58550mm PVC 6KSC
58663mm PVC 4KSC
58775mm PVC 4KSC
58890mm PVC 4 KSC
589110mm PVC 4KSC
590140mm PVC 4KSC
591160mm PVC 4KSC
592200mm PVC 4KSC
593500 mm PSC Pipes
594600 mm PSC Pipes
595Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
59650 mm GI Pipe
59765 mm GI Pipe
59880 mm GI Pipe
599100 mm GI Pipe
600Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
60150 mm GI Pipe
60265 mm GI Pipe
60380 mm GI Pipe
604100 mm GI Pipe
605Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
60650 mm GI Pipe
60765 mm GI Pipe
60880 mm GI Pipe
609100 mm GI Pipe
610Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
61150 mm GI Pipe
61265 mm GI Pipe
61380 mm GI Pipe
614100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
615Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Mukkudal
616Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 982 LPM X 16 M ) including cost of all material ,conveyance, labour charges for removing and re-erection of Submersible pumpset at Head Works, Mukkudal Infiltration Well
617Rewinding of motor and repair works to 100 HP centrifugal HSC Motor ( 5882 lpm x50 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works, Mukkudal Pump Room
618Repair and reconditioning works in 100 HP HSC centrifugal Pump ( 5882 x 50 m Head ) including cost of all material exluding Bronze impeller ,conveyance , labour charges for removing and re-erection of centrifugal HSC Pump at Head Works, Mukkudal Pump Room -
619Rewinding of motor and reconditioning pump and repair works to 1 HP centrifugal Monobloc Pump set (20 LPM x 41m Head) including cost of all material, conveyance, labour charges for removing and re-erection of Monobloc Pump set at Mukkudal. SUMP AT KASINATHAPURAM
620Repair and reconditioning works in 120 HP Vertical turbine Pump ( 5818 lpm x 61 m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Kalingapatti Pump Room
621Rewinding of 120 HP Vertical turbine motor ( 5818 lpm x61 m Head ) including cost ofall materials (excluding SS Hollow/solid shaft), conveyance, labour charges for removing andre-erection of Vertical Turbine Motors etc., complete and as directed by the TWAD Boardofficers.
622Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set 128 lpm x 41m hea m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room ALANGULAM SUMP
623Rewinding of motor and reconditioning pump and repair works to 15HP Submercible Pump set (845 lpm x 38 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Alangulam Pump Room
624Rewinding of motor and reconditioning pump and repair works to 1HP Submercible Pump set (44 lpm x49 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Alangulam Pump Room Kalingapatty sump
625Rewinding of motor works in 120 HP Vertical turbine motor (5374 lpm x64m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room.
626Repair and reconditioning works in 120 HP Vertical turbine Pump (5374 lpm x64m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room. Sendamaram Sump
627Rewinding of motor works in 100 HP Vertical turbine motor (5374 lpm x 47m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room
628Repair and reconditioning works in 100 HP Vertical turbine Pump (5374 lpm x 47m Head ) including cost of all material exluding ,conveyance ,labour charges for removing and re-erection of vertical Turbine pump at Pump Room.
629Rewinding of motor and reconditioning pump and repair works to 2HP submersible Pump set (170lpm x18m) including cost of all material ,conveyance ,labour charges for removing and re-erection Pump set to Sendamaram.
630Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (230lpm x 31m) including cost of all material ,conveyance ,labour charges for removing and re-erection Pump set to veerasigamani. Vellalankottai sump
631Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 295 lpm x21m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vellalankottai-
632Rewinding of motor and reconditioning pump and repair works to 15 HP Submersible Pump set ( 1212 lpm x27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vasudevanallur NARANAPURAM SUMP
633Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x268 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Naranapuram- VADAMALAPURAM SUMP
634Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 52 lpm x18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadamalapuram THIRUMALAPURAM SUMP
635Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 331 lpm x23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalapuram RAYAGIRI SUMP
636Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 208 lpm x35 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Viswanathaperi
637Rewinding of motor and reconditioning pump and repair works to 25 HP Submersible Pump set ( 1087 lpm x 50 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Sivagiri RTP
638Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 709 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Rayagiri RTP
639Rewinding of motor and reconditioning pump and repair works to 1HP Submersible Pump set (68lpm x 24m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Refugee colony
640Rewinding of motor and reconditioning pump and repair works to 1.50 HP Submersible Pump set ( 112 lpm x 19m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Muthukudi
641Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 150lpm x 26m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Samusigapuram
642Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 280lpm x 23m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Samusigapuram
643Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 150 lpm x 33 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ashilapuram
644Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 308 lpm x 30m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kothankulam
645Attending cable fault by replacing the cable 6 Nos of IW
646Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.7098 for following Wells submersible motor to main panel board.35 sqmm Aluminum armoured cable for 7 Nos of IW Including standby pumpset.
647Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.35 sqmm Aluminum armoured cable for 7 Nos of IW Including standby pumpset
648Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. 35 sq.mm cable for 7 Nos.of infiltration wells
649Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset.
650Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. 50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
651Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers Jointing of 50 sq.mm cable for 2 Nos.of infiltration wells
652Replacement of 32-400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers.
6533 Pole MCCB
65432 Amps
65563 Amps
656100 Amps
657250 Amps
658400 Amps
659Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
6609 Amps\440V
66112 Amps\440V
66218 Amps\440V
66325 Amps\440V
66432 Amps\440V
66540 Amps\440V
66645 Amps\440V
66770 Amps\440V
66895 Amps\440V
669225 Amps\440V
670Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
671Upto 5A
672Upto 5A-10A
673Upto 10A-20A
674Upto 20A-30A
675Upto 30A-50A
676Upto 50A-75A
677Upto 75A-110A
678Upto 200A-300A
679Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
680Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply
681Attending Major Repair works to 250KVA Transformer At MUKKUDAL HEAD WORKS
682Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
683Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
684Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
685Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
686Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
687Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
688Supply and delivery of 433KV LV Bushing copper rod to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
689Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
690Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
691Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
692Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
693Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
694Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
695Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
696Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
697Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
698Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
699Attending Major Repair works to 250KVA Transformer At Kasinathapuram, Kalingapatti & Senthamaram Booster Station
700Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
701Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
702Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
703Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
704Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
705Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
706Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
707Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
708Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
709Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
710Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
711Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
712Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
713Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
714Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
715Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
716Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
717Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
718For 1 HP Starter
719For 3 HP Starter
720For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
721Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
722600mm sluice valve
723500 mm CI Sluice valve
724450 mm CI Sluice valve
725400 mm CI Sluice valve
726250 mm CI Scour valve
727350 mm CI Sluice valve
728300 mm CI Sluice valve
729300 mm CI NRV valve
730200 mm CI NRV valve
731150 mm CI Sluice valve
732150 mm CI NRV valve
733100 mm CI Sluice valve
734Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
73550 mm Gate valve
73665 mm Gate valve
73780 mm Gate valve
738100 mm Gate valve
739Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
740Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
741Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
742Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
743Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
7444.00 LL capacity of sump @ head works Mukkudal
7458.00 LL capacity of sump @ Kasinathapuam
7467.00 LL capacity of sump @ , kalinkapatty, Sendamaram
7471.50 LL capacity of sump @ Rayagiri
7481.00 LL capacity of sump @ Alangulam, velllankottai
7490.30 LL capacity of sump @ Gudalure and Thirumalapuram
7500.15 LL capacity of sump @ Vadamalapuram
7510.10 LL capacity of sump @ Naranapuram
7524.00 LL capacity of sump @ Srivilliputhur
7531.50 LL capacity of sump @ Samsigapuram
7541.00. LL capacity of sump @ Kothankulam
7550.30 LL capacity of sump @ Refuge colony
7560.60 LL capacity of sump @ Asilapuram and Muthukudi
7572.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
758Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 12.18 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 1096.2 ML (12.18*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
759Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
760AC Pipes of various sizes
761PSC Pipes of various sizes
762Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
763150 mm AC Pipe
764200 mm AC Pipe
765300 mm AC Pipe
766350 mm PSC Pipe
767450 mm PSC Pipe
768500 mm PSC Pipe
769600 mm PSC Pipe
770700 mm PSC Pipe
771Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
772150 mm AC Pipe
773200 mm AC Pipe
774300 mm AC Pipe
775350 mm PSC Pipe
776450 mm PSC Pipe
777500 mm PSC Pipe
778600 mm PSC Pipe
779700 mm PSC Pipe
780Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
781150 mm AC Pipe
782200 mm AC Pipe
783300 mm AC Pipe
784350 mm PSC Pipe
785450 mm PSC Pipe
786500 mm PSC Pipe
787600 mm PSC Pipe
788700 mm PSC Pipe
789Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
790150 mm AC Pipe
791200 mm AC Pipe
792300 mm AC Pipe
793350 mm PSC Pipe
794450 mm PSC Pipe
795500 mm PSC Pipe
796600 mm PSC Pipe
797700 mm PSC Pipe
798Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
799AC Pipes of various sizes
800PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
801Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
802MS Pipes of various sizes
803Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
804350 mm MS Pipe
805450 mm MS Pipe
806500 mm MS Pipe
807600 mm MS Pipe
808Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
809350 mm MS Pipe
810450 mm MS Pipe
811500 mm MS Pipe
812600 mm MS Pipe
813Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
814350 mm MS Pipe
815450 mm MS Pipe
816500 mm MS Pipe
817600 mm MS Pipe
818Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
819350mm ms pipe
820350mm machine end
821450mm MS pipe
822450mm machine end
823500mm MS pipe
824500mm machine end
825600mm MS pipe
826600mm machine end
827Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
828MS Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
829Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
830For PVC Pipes of various sizes
831For AC Pipes of various sizes
832For PSC Pipes of various sizes
833Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
83450mm PVC 6KSC
83563mm PVC 4KSC
83675mm PVC 4KSC
83790mm PVC 4 KSC
838110mm PVC 4KSC
839140mm PVC 4KSC
840160mm PVC 4KSC
841Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
842150 mm AC Pipes Class 15
843200 mm AC Pipes Class 15
844300 mm AC Pipes Class 15
845Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
846355.6 mm x 4 mm thick MS PIPE
847457 mm x 4 mm thick PIPE
848508 mm x 5 mm thick MS PIPE
849610 mm x 5.8 mm thick MS PIPE
850711 mm x 6.3 mm thick PIPE
851Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
85250 mm PVC Coupler Fabricated 6 KSC
85363 mm PVC Coupler Fabricated 4 KSC
85475 mm PVC Coupler Fabricated 4 KSC
85590 mm PVC Coupler Fabricated 4 KSC
856110 mm PVC Coupler Fabricated 4 KSC
857140 mm PVC Coupler Fabricated 4 KSC
858160 mm PVC Coupler Fabricated 4 KSC
859Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
860150 mm AC Pipes Class 15
861200 mm AC Pipes Class 15
862300 mm AC Pipes Class 15
863Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
864350mm MJ Collars for MS pipe
865450mm MJ Collars for MS pipe
866500mm MJ Collars for MS pipe
867600mm MJ Collars for MS pipe
868700mm MJ Collars for PSC pipe
869Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
87050mm PVC 6KSC
87163mm PVC 4KSC
87275mm PVC 4KSC
87390mm PVC 4 KSC
874110mm PVC 4KSC
875140mm PVC 4KSC
876160mm PVC 4KSC
877150 mm dia AC Class 15 Pipe
878200 mm dia AC Class 15 Pipe
879300 mm dia AC Class 15 Pipe
880For 350 mm PSC Pipes of various classes
881For 450 mm PSC Pipes of various classes
882For 500 mm PSC Pipes of various classes
883For 600 mm PSC Pipes of various classes
884For 700 mm PSC Pipes of various classes
885Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
88650 mm GI Pipe
88765 mm GI Pipe
88880 mm GI Pipe
889100 mm GI Pipe
890Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
89150 mm GI Pipe
89265 mm GI Pipe
89380 mm GI Pipe
894100 mm GI Pipe
895Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
89650 mm GI Pipe
89765 mm GI Pipe
89880 mm GI Pipe
899100 mm GI Pipe
900Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
90150 mm GI Pipe
90265 mm GI Pipe
90380 mm GI Pipe
904100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
905Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers HEAD WORKS
906Rewinding of motor and reconditioning pump and repair works to 10 HP Open Well Submersible Pump Set ( 1490 LPM X 16 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
907Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 1000 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
908Rewinding of motor and repair works to 170 HP centrifugal HSC Motor ( 11920 X 47 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
909Repair and reconditioning of 170 HP centrifugal HSC Pump ( 11920 lpm x 47m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works THALAISUBRAMANIYAPURAM BOOSTER STATION
910Rewinding of motor and repair works to 270 HP centrifugal HSC Motor ( 11920 X 75 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at TS Puram
911Repair and reconditioning of 270 HP centrifugal HSC Pump ( 11920 lpm x 75m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at TS Puram ATHIYOUTH SUMP
912Rewinding of motor and reconditioning pump and repair works to 4 HP Centrifugal Monobloc Pumpsets (466 lpm x 16 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kaluneerkulam - 2 Nos ( Including stand by ) VK PUDUR SUMP
913Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets (191 lpm x 43 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at VK Puthur
914Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets (354 lpm x 31 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Rajagopalaperi KALINGAPATTI BOOSTER STATION
915Rewinding of motor and repair works to 170 HP centrifugal HSC Motor ( 11065 X 52 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kalingapatti -
916Repair and reconditioning of 170 HP centrifugal HSC Pump ( 11065 X 52 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kalingapatti
917Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (123 lpm x38 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurichampatti Surandai sump
918Rewinding of motor and repair works to 20 HP centrifugal HSC Motor ( 1011 X 50 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kulayaneri & Anaikulam
919Repair and reconditioning of 20 HP centrifugal HSC Pumpset ( 1011 X 50 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kulayaneri & Anaikulam
920Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets (709 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Surandai RTP
921Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 342 lpm x 40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Surandai RTP
922Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 235 lpm x 25 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Bungalow Surandai
923Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 124 lpm x 29 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Aladipatti
924Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (342 lpm x36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Suntharapandiaypuram ( Including stand by ) Sambavarvadakarai sump
925Rewinding of motor and reconditioning pump and repair works to 4 HP Centrifugal Monobloc Pumpsets ( 249 lpm x 28 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SV Karai -
926Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 261 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SV Karai KADAYALURITY SUMP
927Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 149 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nochikulam
928Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 523 lpm x 29 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Uthankulam
929Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 102 lpm x 54 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Senthamaram Cusba VELAUTHAPURAM SUMP
930Rewinding of motor and repair works to 150 HP centrifugal HSC Motor ( 7423 X 61 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Velayuthapuram
931Repair and reconditioning of 150 HP centrifugal HSC pump ( 7423 X 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Velayuthapuram
932Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 375 lpm x 41 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kallampuli
933Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 599 lpm x 27 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Urmelalagian SANGUPURAM pump room
934Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 439 lpm x 42 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Sangupuram - 1 nos SIVARAMANPATTAI PUMP ROOM
935Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 100 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Neduvayal MANGALAPURAM Sump
936Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 106 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Achampatti
937Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 50 lpm x 24 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mangalapuram Colony PUDUKUDI SUMP
938Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 406 lpm x 70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Thirikoodapuram - BALAARUNACHALAPURAM SUMP
939Rewinding of motor and repair works to 75 HP centrifugal HSC Motor ( 3623 X 54 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Puliyankudi -
940Repair and reconditioning of 75 HP centrifugal HSC pump ( 3623 X 54 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Puliyankudi
941Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 352 lpm x 12 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Valasai
942Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 123 lpm x 28 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Boganallur
943Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 110 lpm x 32 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achampatti SINGILIPATTY
944Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 206 lpm x 14 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Punnaiyapuram
945Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 50 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Singilipatti colony VETRAMPATTYI SUMP
946Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 180 lpm x 60 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thiruvettanallur KADAYANALUR SUMP
947Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 1591 lpm x 27 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Weekly market - 2 Nos ( Including stand by )
948Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 1503 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Fire station
949Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 134 lpm x 22 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kasitharmam
950Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 503 lpm x 24 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Krishnapuram PULIYANGUDI SUMP
951Rewinding of motor and repair works to 20 HP centrifugal HSC Motor 2303 lpm x 20 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Puliyankudi GH
952Repair and reconditioning of 20 HP centrifugal HSC Motor 2303 lpm x 20 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Puliyankudi GH s
953Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 332 lpm x 16 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Pallivasal
954Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 330 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SS School
955Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 347 lpm x 8 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Chinthamani
956Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Sattupathu Head works pump room
957Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
958Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
959Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
960Attending cable fault for infiltration well for 10 HP Submersible Motor to Main Panel Board at Sattupathu Head works pump room
961Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
962Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. 50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
963Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers Jointing of 50 sq.mm cable for 2 Nos.of infiltration wells
964Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
96532 Amps
96663 Amps
967100 Amps
968250 Amps
969400 Amps
970600 Amps
971Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
972400 Amps\440V
973140 Amps\440V
974110 Amps\440V
97540 Amps\440V
97632 Amps\440V
97725 Amps\440V
978Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
979Upto 5A
980Upto 10A-20A
981Upto 20A-30A
982Upto 50A-75A
983Upto 110A-150A
984Upto 150A-200A
985Upto 200A-300A
986Attending Major Repair works to 315 KVA Transformer At Sattupathu Head works
987Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
988Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
989Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
990Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
991Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
992Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
993Supply and delivery of 433KV LV Bushing copper rod to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
994Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
995Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
996Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
997Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
998Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
999Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1000Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1001Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1002Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1003Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1004Attending Major Repair works to 400 KVA Transformer At TS Puram Booster station
1005Labour charges for dismantling of 400 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1006Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1007Supply and delivery of LV 433V Copper windings for 3 phase insulation to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1008Supply and delivery of 3 phase insulation to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1009Supply and delivery of new transformer oil to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1010Supply and delivery of 11KV HV Bushing with metal parts to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1011Supply and delivery of 433KV LV Bushing copper rod to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1012Supply and delivery of silica gel breather to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1013Supply and delivery of Capillary type thermometer including accessories to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1014Supply and delivery of gasket & oil seals to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1015Supply and delivery of paint to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1016Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1017Charges for transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1018Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1019Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1020Labour charges for Re rection of 400 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1021Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1022Attending Major Repair works to 250 KVA Transformer At Kaligapatti, Velayuthapuram Booster station
1023Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1024Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1025Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1026Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1027Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1028Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1029Supply and delivery of 433KV LV Bushing copper rod to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1030Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1031Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1032Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1033Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1034Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1035Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1036Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1037Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1038Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1039Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1040Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers.
1041For 7.5 HP Starter -1 No
1042For 10 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1043Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV / Scour valve / ARV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1044500 mm CI Sluice valve
1045450 mm CI Sluice valve
1046400 mm CI Scour valve
1047250 mm CI Scour valve
1048350 mm CI Sluice valve
1049350 mm CI Scour valve
1050350 mm CI NRV valve
1051200 mm CI Sluice valve
1052200 mm CI Scour valve
1053250 mm CI NRV valve
1054250 mm CI Sluice valve
1055150 mm CI Sluice valve
1056150 mm Double Chamber Air Release Valve
1057100 mm Double Chamber Air Release Valve
105880 mm Double Chamber Air Release Valve
1059Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
106050 mm Gate valve
106165 mm Gate valve
106280 mm Gate valve
1063100 mm Gate valve
1064Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
1065Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
1066Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1067Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1068Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
10693.00 LL capacity of sump @ head works, Sattupathu
107010.00 LL capacity of sump @ Thalaisubramaniapuram,
10719.00 LL capacity of sump @ kalinkapatty
10727.00 LL capacity of sump @ Velayuthapuram
10733.50 LL capacity of sump @ Balaarunachalapuram
10743.00 LL capacity of sump @ Kadayanallur & Puliyangudi
10751.50 LL capacity of sump @ Athiyoothu, Surandai and Kadayalurutti
10760.60 LL capacity of sump @ Pudukudi, Sambavarvadakarai
10770.30 LL capacity of sump @ V.K.Pudur, Sangupuram, Mangalapuram & Sivaramapetti For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
1078Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 12.18 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 4445.70 ML (12.18*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
1079Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1080AC Pipes of various sizes
1081PSC Pipes of various sizes
1082Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1083150 mm AC Pipe
1084200 mm AC Pipe
1085300 mm AC Pipe
1086350 mm PSC Pipe
1087450 mm PSC Pipe
1088500 mm PSC Pipe
1089600 mm PSC Pipe
1090700 mm PSC Pipe
1091Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1092150 mm AC Pipe
1093200 mm AC Pipe
1094300 mm AC Pipe
1095350 mm PSC Pipe
1096450 mm PSC Pipe
1097500 mm PSC Pipe
1098600 mm PSC Pipe
1099700 mm PSC Pipe
1100Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
1101150 mm AC Pipe
1102200 mm AC Pipe
1103300 mm AC Pipe
1104350 mm PSC Pipe
1105450 mm PSC Pipe
1106500 mm PSC Pipe
1107600 mm PSC Pipe
1108700 mm PSC Pipe
1109Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1110150 mm AC Pipe
1111200 mm AC Pipe
1112300 mm AC Pipe
1113350 mm PSC Pipe
1114450 mm PSC Pipe
1115500 mm PSC Pipe
1116600 mm PSC Pipe
1117700 mm PSC Pipe
1118Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1119AC Pipes of various sizes
1120PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
1121Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1122MS Pipes of various sizes
1123Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
1124350 mm MS Pipe
1125450 mm MS Pipe
1126500 mm MS Pipe
1127600 mm MS Pipe
1128Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
1129350 mm MS Pipe
1130450 mm MS Pipe
1131500 mm MS Pipe
1132600 mm MS Pipe
1133Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
1134350 mm MS Pipe
1135450 mm MS Pipe
1136500 mm MS Pipe
1137600 mm MS Pipe
1138Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
1139350mm ms pipe
1140350mm machine end
1141450mm MS pipe
1142450mm machine end
1143500mm MS pipe
1144500mm machine end
1145600mm MS pipe
1146600mm machine end
1147Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1148MS Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1149Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1150For PVC Pipes of various sizes
1151For AC Pipes of various sizes
1152For PSC Pipes of various sizes
1153Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
115450mm PVC 6KSC
115563mm PVC 4KSC
115675mm PVC 4KSC
115790mm PVC 4 KSC
1158110mm PVC 4KSC
1159140mm PVC 4KSC
1160160mm PVC 4KSC
1161Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
1162150 mm AC Pipes Class 15
1163200 mm AC Pipes Class 15
1164300 mm AC Pipes Class 15
1165Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
1166355.6 mm x 4 mm thick MS PIPE
1167457 mm x 4 mm thick PIPE
1168508 mm x 5 mm thick MS PIPE
1169610 mm x 5.8 mm thick MS PIPE
1170711 mm x 6.3 mm thick PIPE
1171Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
117250 mm PVC Coupler Fabricated 6 KSC
117363 mm PVC Coupler Fabricated 4 KSC
117475 mm PVC Coupler Fabricated 4 KSC
117590 mm PVC Coupler Fabricated 4 KSC
1176110 mm PVC Coupler Fabricated 4 KSC
1177140 mm PVC Coupler Fabricated 4 KSC
1178160 mm PVC Coupler Fabricated 4 KSC
1179Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
1180150 mm AC Pipes Class 15
1181200 mm AC Pipes Class 15
1182300 mm AC Pipes Class 15
1183Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
1184350mm MJ Collars for MS pipe
1185450mm MJ Collars for MS pipe
1186500mm MJ Collars for MS pipe
1187600mm MJ Collars for MS pipe
1188700mm MJ Collars for PSC pipe
1189Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
119050mm PVC 6KSC
119163mm PVC 4KSC
119275mm PVC 4KSC
119390mm PVC 4 KSC
1194110mm PVC 4KSC
1195140mm PVC 4KSC
1196160mm PVC 4KSC
1197150 mm dia AC Class 15 Pipe
1198200 mm dia AC Class 15 Pipe
1199300 mm dia AC Class 15 Pipe
1200For 350 mm PSC Pipes of various classes
1201For 450 mm PSC Pipes of various classes
1202For 500 mm PSC Pipes of various classes
1203For 600 mm PSC Pipes of various classes
1204For 700 mm PSC Pipes of various classes
1205Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
120650 mm GI Pipe
120765 mm GI Pipe
120880 mm GI Pipe
1209100 mm GI Pipe
1210Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
121150 mm GI Pipe
121265 mm GI Pipe
121380 mm GI Pipe
1214100 mm GI Pipe
1215Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
121650 mm GI Pipe
121765 mm GI Pipe
121880 mm GI Pipe
1219100 mm GI Pipe
1220Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
122150 mm GI Pipe
122265 mm GI Pipe
122380 mm GI Pipe
1224100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
1225Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers HEAD WORKS
1226Rewinding of motor and reconditioning pump and repair works to 10 HP Open Well Submersible Pump Set ( 1490 LPM X 16 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1227Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 1000 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1228Rewinding of motor and repair works to 170 HP centrifugal HSC Motor ( 11920 X 47 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
1229Repair and reconditioning of 170 HP centrifugal HSC Pump ( 11920 lpm x 47m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works THALAISUBRAMANIYAPURAM BOOSTER STATION
1230Rewinding of motor and repair works to 270 HP centrifugal HSC Motor ( 11920 X 75 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at TS Puram
1231Repair and reconditioning of 270 HP centrifugal HSC Pump ( 11920 lpm x 75m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at TS Puram ATHIYOUTH SUMP
1232Rewinding of motor and reconditioning pump and repair works to 4 HP Centrifugal Monobloc Pumpsets (466 lpm x 16 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kaluneerkulam - 2 Nos ( Including stand by ) VK PUDUR SUMP
1233Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets (191 lpm x 43 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at VK Puthur
1234Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets (354 lpm x 31 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Rajagopalaperi KALINGAPATTI BOOSTER STATION
1235Rewinding of motor and repair works to 170 HP centrifugal HSC Motor ( 11065 X 52 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kalingapatti -
1236Repair and reconditioning of 170 HP centrifugal HSC Pump ( 11065 X 52 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kalingapatti
1237Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (123 lpm x38 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurichampatti Surandai sump
1238Rewinding of motor and repair works to 20 HP centrifugal HSC Motor ( 1011 X 50 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kulayaneri & Anaikulam
1239Repair and reconditioning of 20 HP centrifugal HSC Pumpset ( 1011 X 50 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kulayaneri & Anaikulam
1240Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets (709 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Surandai RTP
1241Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 342 lpm x 40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Surandai RTP
1242Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 235 lpm x 25 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Bungalow Surandai
1243Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 124 lpm x 29 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Aladipatti
1244Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (342 lpm x36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Suntharapandiaypuram ( Including stand by ) Sambavarvadakarai sump
1245Rewinding of motor and reconditioning pump and repair works to 4 HP Centrifugal Monobloc Pumpsets ( 249 lpm x 28 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SV Karai -
1246Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 261 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SV Karai KADAYALURITY SUMP
1247Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 149 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nochikulam
1248Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 523 lpm x 29 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Uthankulam
1249Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 102 lpm x 54 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Senthamaram Cusba VELAUTHAPURAM SUMP
1250Rewinding of motor and repair works to 150 HP centrifugal HSC Motor ( 7423 X 61 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Velayuthapuram
1251Repair and reconditioning of 150 HP centrifugal HSC pump ( 7423 X 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Velayuthapuram
1252Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 375 lpm x 41 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kallampuli
1253Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 599 lpm x 27 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Urmelalagian SANGUPURAM pump room
1254Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 439 lpm x 42 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Sangupuram - 1 nos SIVARAMANPATTAI PUMP ROOM
1255Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 100 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Neduvayal MANGALAPURAM Sump
1256Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 106 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Achampatti
1257Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 50 lpm x 24 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mangalapuram Colony PUDUKUDI SUMP
1258Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 406 lpm x 70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Thirikoodapuram - BALAARUNACHALAPURAM SUMP
1259Rewinding of motor and repair works to 75 HP centrifugal HSC Motor ( 3623 X 54 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Puliyankudi -
1260Repair and reconditioning of 75 HP centrifugal HSC pump ( 3623 X 54 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Puliyankudi
1261Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 352 lpm x 12 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Valasai
1262Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 123 lpm x 28 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Boganallur
1263Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 110 lpm x 32 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achampatti SINGILIPATTY
1264Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 206 lpm x 14 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Punnaiyapuram
1265Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 50 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Singilipatti colony VETRAMPATTYI SUMP
1266Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 180 lpm x 60 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thiruvettanallur KADAYANALUR SUMP
1267Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 1591 lpm x 27 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Weekly market - 2 Nos ( Including stand by )
1268Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 1503 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Fire station
1269Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 134 lpm x 22 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kasitharmam
1270Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 503 lpm x 24 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Krishnapuram PULIYANGUDI SUMP
1271Rewinding of motor and repair works to 20 HP centrifugal HSC Motor 2303 lpm x 20 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Puliyankudi GH
1272Repair and reconditioning of 20 HP centrifugal HSC Motor 2303 lpm x 20 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Puliyankudi GH s
1273Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 332 lpm x 16 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Pallivasal
1274Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 330 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SS School
1275Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 347 lpm x 8 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Chinthamani
1276Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Sattupathu Head works pump room
1277Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
1278Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
1279Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
1280Attending cable fault for infiltration well for 10 HP Submersible Motor to Main Panel Board at Sattupathu Head works pump room
1281Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
1282Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. 50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
1283Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers Jointing of 50 sq.mm cable for 2 Nos.of infiltration wells
1284Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
128532 Amps
128663 Amps
1287100 Amps
1288250 Amps
1289400 Amps
1290600 Amps
1291Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
1292400 Amps\440V
1293140 Amps\440V
1294110 Amps\440V
129540 Amps\440V
129632 Amps\440V
129725 Amps\440V
1298Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
1299Upto 5A
1300Upto 10A-20A
1301Upto 20A-30A
1302Upto 50A-75A
1303Upto 110A-150A
1304Upto 150A-200A
1305Upto 200A-300A
1306Attending Major Repair works to 315 KVA Transformer At Sattupathu Head works
1307Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1308Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1309Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1310Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1311Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1312Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1313Supply and delivery of 433KV LV Bushing copper rod to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1314Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1315Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1316Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1317Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1318Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1319Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1320Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1321Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1322Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1323Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1324Attending Major Repair works to 400 KVA Transformer At TS Puram Booster station
1325Labour charges for dismantling of 400 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1326Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1327Supply and delivery of LV 433V Copper windings for 3 phase insulation to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1328Supply and delivery of 3 phase insulation to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1329Supply and delivery of new transformer oil to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1330Supply and delivery of 11KV HV Bushing with metal parts to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1331Supply and delivery of 433KV LV Bushing copper rod to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1332Supply and delivery of silica gel breather to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1333Supply and delivery of Capillary type thermometer including accessories to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1334Supply and delivery of gasket & oil seals to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1335Supply and delivery of paint to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1336Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1337Charges for transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1338Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1339Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1340Labour charges for Re rection of 400 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1341Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1342Attending Major Repair works to 250KVA Transformer At Kaligapatti, Velayuthapuram Booster station
1343Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1344Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1345Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1346Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1347Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1348Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1349Supply and delivery of 433KV LV Bushing copper rod to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1350Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1351Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1352Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1353Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1354Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1355Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1356Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1357Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1358Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1359Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1360Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers.
1361For 7.5 HP Starter -1 No
1362For 10 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1363Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV / Scour valve / ARV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1364500 mm CI Sluice valve
1365450 mm CI Sluice valve
1366400 mm CI Scour valve
1367250 mm CI Scour valve
1368350 mm CI Sluice valve
1369350 mm CI Scour valve
1370350 mm CI NRV valve
1371200 mm CI Sluice valve
1372200 mm CI Scour valve
1373250 mm CI NRV valve
1374250 mm CI Sluice valve
1375150 mm CI Sluice valve
1376150 mm Double Chamber Air Release Valve
1377100 mm Double Chamber Air Release Valve
137880 mm Double Chamber Air Release Valve
1379Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
138050 mm Gate valve
138165 mm Gate valve
138280 mm Gate valve
1383100 mm Gate valve
1384Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
1385Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
1386Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1387Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1388Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
13893.00 LL capacity of sump @ head works, Sattupathu
139010.00 LL capacity of sump @ Thalaisubramaniapuram,
13919.00 LL capacity of sump @ kalinkapatty
13927.00 LL capacity of sump @ Velayuthapuram
13933.50 LL capacity of sump @ Balaarunachalapuram
13943.00 LL capacity of sump @ Kadayanallur & Puliyangudi
13951.50 LL capacity of sump @ Athiyoothu, Surandai and Kadayalurutti
13960.60 LL capacity of sump @ Pudukudi, Sambavarvadakarai
13970.30 LL capacity of sump @ V.K.Pudur, Sangupuram, Mangalapuram & Sivaramapetti For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
1398Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 12.18 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 4445.70 ML (12.18*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
1399Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1400AC Pipes of various sizes
1401PSC Pipes of various sizes
1402Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1403150 mm AC Pipe
1404200 mm AC Pipe
1405300 mm AC Pipe
1406350 mm PSC Pipe
1407450 mm PSC Pipe
1408500 mm PSC Pipe
1409600 mm PSC Pipe
1410700 mm PSC Pipe
1411Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1412150 mm AC Pipe
1413200 mm AC Pipe
1414300 mm AC Pipe
1415350 mm PSC Pipe
1416450 mm PSC Pipe
1417500 mm PSC Pipe
1418600 mm PSC Pipe
1419700 mm PSC Pipe
1420Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
1421150 mm AC Pipe
1422200 mm AC Pipe
1423300 mm AC Pipe
1424350 mm PSC Pipe
1425450 mm PSC Pipe
1426500 mm PSC Pipe
1427600 mm PSC Pipe
1428700 mm PSC Pipe
1429Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1430150 mm AC Pipe
1431200 mm AC Pipe
1432300 mm AC Pipe
1433350 mm PSC Pipe
1434450 mm PSC Pipe
1435500 mm PSC Pipe
1436600 mm PSC Pipe
1437700 mm PSC Pipe
1438Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1439AC Pipes of various sizes
1440PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
1441Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1442Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
1443350 mm MS Pipe
1444450 mm MS Pipe
1445500 mm MS Pipe
1446600 mm MS Pipe
1447Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
1448350 mm MS Pipe
1449450 mm MS Pipe
1450500 mm MS Pipe
1451600 mm MS Pipe
1452Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
1453350 mm MS Pipe
1454450 mm MS Pipe
1455500 mm MS Pipe
1456600 mm MS Pipe
1457Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
1458350mm ms pipe
1459350mm machine end
1460450mm MS pipe
1461450mm machine end
1462500mm MS pipe
1463500mm machine end
1464600mm MS pipe
1465600mm machine end
1466Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1467MS Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1468Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1469For PVC Pipes of various sizes
1470For AC Pipes of various sizes
1471For PSC Pipes of various sizes
1472Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
147350mm PVC 6KSC
147463mm PVC 4KSC
147575mm PVC 4KSC
147690mm PVC 4 KSC
1477110mm PVC 4KSC
1478140mm PVC 4KSC
1479160mm PVC 4KSC
1480Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
1481150 mm AC Pipes Class 15
1482200 mm AC Pipes Class 15
1483300 mm AC Pipes Class 15
1484Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
1485355.6 mm x 4 mm thick MS PIPE
1486457 mm x 4 mm thick PIPE
1487508 mm x 5 mm thick MS PIPE
1488610 mm x 5.8 mm thick MS PIPE
1489711 mm x 6.3 mm thick PIPE
1490Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
149150 mm PVC Coupler Fabricated 6 KSC
149263 mm PVC Coupler Fabricated 4 KSC
149375 mm PVC Coupler Fabricated 4 KSC
149490 mm PVC Coupler Fabricated 4 KSC
1495110 mm PVC Coupler Fabricated 4 KSC
1496140 mm PVC Coupler Fabricated 4 KSC
1497160 mm PVC Coupler Fabricated 4 KSC
1498Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
1499150 mm AC Pipes Class 15
1500200 mm AC Pipes Class 15
1501300 mm AC Pipes Class 15
1502Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
1503350mm MJ Collars for MS pipe
1504450mm MJ Collars for MS pipe
1505500mm MJ Collars for MS pipe
1506600mm MJ Collars for MS pipe
1507700mm MJ Collars for PSC pipe
1508Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
150950mm PVC 6KSC
151063mm PVC 4KSC
151175mm PVC 4KSC
151290mm PVC 4 KSC
1513110mm PVC 4KSC
1514140mm PVC 4KSC
1515160mm PVC 4KSC
1516150 mm dia AC Class 15 Pipe
1517200 mm dia AC Class 15 Pipe
1518300 mm dia AC Class 15 Pipe
1519For 350 mm PSC Pipes of various classes
1520For 450 mm PSC Pipes of various classes
1521For 500 mm PSC Pipes of various classes
1522For 600 mm PSC Pipes of various classes
1523For 700 mm PSC Pipes of various classes
1524Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
152550 mm GI Pipe
152665 mm GI Pipe
152780 mm GI Pipe
1528100 mm GI Pipe
1529Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
153050 mm GI Pipe
153165 mm GI Pipe
153280 mm GI Pipe
1533100 mm GI Pipe
1534Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
153550 mm GI Pipe
153665 mm GI Pipe
153780 mm GI Pipe
1538100 mm GI Pipe
1539Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
154050 mm GI Pipe
154165 mm GI Pipe
154280 mm GI Pipe
1543100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
1544Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers HEAD WORKS
1545Rewinding of motor and reconditioning pump and repair works to 10 HP Open Well Submersible Pump Set ( 1490 LPM X 16 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1546Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 1000 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1547Rewinding of motor and repair works to 170 HP centrifugal HSC Motor ( 11920 X 47 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
1548Repair and reconditioning of 170 HP centrifugal HSC Pump ( 11920 lpm x 47m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works THALAISUBRAMANIYAPURAM BOOSTER STATION
1549Rewinding of motor and repair works to 270 HP centrifugal HSC Motor ( 11920 X 75 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at TS Puram
1550Repair and reconditioning of 270 HP centrifugal HSC Pump ( 11920 lpm x 75m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at TS Puram ATHIYOUTH SUMP
1551Rewinding of motor and reconditioning pump and repair works to 4 HP Centrifugal Monobloc Pumpsets (466 lpm x 16 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kaluneerkulam - 2 Nos ( Including stand by ) VK PUDUR SUMP
1552Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets (191 lpm x 43 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at VK Puthur
1553Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets (354 lpm x 31 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Rajagopalaperi KALINGAPATTI BOOSTER STATION
1554Rewinding of motor and repair works to 170 HP centrifugal HSC Motor ( 11065 X 52 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kalingapatti -
1555Repair and reconditioning of 170 HP centrifugal HSC Pump ( 11065 X 52 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kalingapatti
1556Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (123 lpm x38 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurichampatti Surandai sump
1557Rewinding of motor and repair works to 20 HP centrifugal HSC Motor ( 1011 X 50 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kulayaneri & Anaikulam
1558Repair and reconditioning of 20 HP centrifugal HSC Pumpset ( 1011 X 50 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kulayaneri & Anaikulam
1559Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets (709 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Surandai RTP
1560Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 342 lpm x 40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Surandai RTP
1561Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 235 lpm x 25 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Bungalow Surandai
1562Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 124 lpm x 29 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Aladipatti
1563Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (342 lpm x36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Suntharapandiaypuram ( Including stand by ) Sambavarvadakarai sump
1564Rewinding of motor and reconditioning pump and repair works to 4 HP Centrifugal Monobloc Pumpsets ( 249 lpm x 28 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SV Karai -
1565Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 261 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SV Karai KADAYALURITY SUMP
1566Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 149 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nochikulam
1567Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 523 lpm x 29 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Uthankulam
1568Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 102 lpm x 54 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Senthamaram Cusba VELAUTHAPURAM SUMP
1569Rewinding of motor and repair works to 150 HP centrifugal HSC Motor ( 7423 X 61 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Velayuthapuram
1570Repair and reconditioning of 150 HP centrifugal HSC pump ( 7423 X 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Velayuthapuram
1571Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 375 lpm x 41 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kallampuli
1572Rewinding of motor and reconditioning pump and repair works to 7.5 HP Centrifugal Monobloc Pumpsets ( 599 lpm x 27 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Urmelalagian SANGUPURAM pump room
1573Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 439 lpm x 42 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Sangupuram - 1 nos SIVARAMANPATTAI PUMP ROOM
1574Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 100 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Neduvayal MANGALAPURAM Sump
1575Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 106 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Achampatti
1576Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 50 lpm x 24 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mangalapuram Colony PUDUKUDI SUMP
1577Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 406 lpm x 70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Thirikoodapuram - BALAARUNACHALAPURAM SUMP
1578Rewinding of motor and repair works to 75 HP centrifugal HSC Motor ( 3623 X 54 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Puliyankudi -
1579Repair and reconditioning of 75 HP centrifugal HSC pump ( 3623 X 54 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Puliyankudi
1580Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 352 lpm x 12 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Valasai
1581Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 123 lpm x 28 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Boganallur
1582Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 110 lpm x 32 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achampatti SINGILIPATTY
1583Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 206 lpm x 14 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Punnaiyapuram
1584Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 50 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Singilipatti colony VETRAMPATTYI SUMP
1585Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 180 lpm x 60 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thiruvettanallur KADAYANALUR SUMP
1586Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 1591 lpm x 27 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Weekly market - 2 Nos ( Including stand by )
1587Rewinding of motor and reconditioning pump and repair works to 15 HP Centrifugal Monobloc Pumpsets ( 1503 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Fire station
1588Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 134 lpm x 22 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kasitharmam
1589Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 503 lpm x 24 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Krishnapuram PULIYANGUDI SUMP
1590Rewinding of motor and repair works to 20 HP centrifugal HSC Motor 2303 lpm x 20 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Puliyankudi GH
1591Repair and reconditioning of 20 HP centrifugal HSC Motor 2303 lpm x 20 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Puliyankudi GH s
1592Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 332 lpm x 16 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Pallivasal
1593Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 330 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at SS School
1594Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 347 lpm x 8 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Chinthamani
1595Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Sattupathu Head works pump room
1596Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
1597Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
1598Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
1599Attending cable fault for infiltration well for 10 HP Submersible Motor to Main Panel Board at Sattupathu Head works pump room
1600Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
1601Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. 50 sqmm Aluminum armoured cable for 2 Nos of IW Including standby pumpset
1602Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers Jointing of 50 sq.mm cable for 2 Nos.of infiltration wells
1603Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
160432 Amps
160563 Amps
1606100 Amps
1607250 Amps
1608400 Amps
1609600 Amps
1610Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
1611400 Amps\440V
1612140 Amps\440V
1613110 Amps\440V
161440 Amps\440V
161532 Amps\440V
161625 Amps\440V
1617Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
1618Upto 5A
1619Upto 10A-20A
1620Upto 20A-30A
1621Upto 50A-75A
1622Upto 110A-150A
1623Upto 150A-200A
1624Upto 200A-300A
1625Attending Major Repair works to 315 KVA Transformer At Sattupathu Head works
1626Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1627Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1628Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1629Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1630Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1631Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1632Supply and delivery of 433KV LV Bushing copper rod to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1633Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1634Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1635Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1636Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1637Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1638Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1639Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1640Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1641Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1642Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1643Attending Major Repair works to 400 KVA Transformer At TS Puram Booster station
1644Labour charges for dismantling of 400 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1645Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1646Supply and delivery of LV 433V Copper windings for 3 phase insulation to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1647Supply and delivery of 3 phase insulation to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1648Supply and delivery of new transformer oil to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1649Supply and delivery of 11KV HV Bushing with metal parts to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1650Supply and delivery of 433KV LV Bushing copper rod to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1651Supply and delivery of silica gel breather to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1652Supply and delivery of Capillary type thermometer including accessories to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1653Supply and delivery of gasket & oil seals to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1654Supply and delivery of paint to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1655Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1656Charges for transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1657Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1658Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1659Labour charges for Re rection of 400 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1660Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1661Attending Major Repair works to 250KVA Transformer At Kaligapatti, Velayuthapuram Booster station
1662Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1663Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1664Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1665Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1666Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1667Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1668Supply and delivery of 433KV LV Bushing copper rod to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1669Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1670Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1671Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1672Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1673Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1674Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1675Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1676Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1677Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1678Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1679Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers.
1680For 7.5 HP Starter -1 No
1681For 10 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1682Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV / Scour valve / ARV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1683500 mm CI Sluice valve
1684450 mm CI Sluice valve
1685400 mm CI Scour valve
1686250 mm CI Scour valve
1687350 mm CI Sluice valve
1688350 mm CI Scour valve
1689350 mm CI NRV valve
1690200 mm CI Sluice valve
1691200 mm CI Scour valve
1692250 mm CI NRV valve
1693250 mm CI Sluice valve
1694150 mm CI Sluice valve
1695150 mm Double Chamber Air Release Valve
1696100 mm Double Chamber Air Release Valve
169780 mm Double Chamber Air Release Valve
1698Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
169950 mm Gate valve
170065 mm Gate valve
170180 mm Gate valve
1702100 mm Gate valve
1703Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
1704Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
1705Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1706Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1707Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
17083.00 LL capacity of sump @ head works, Sattupathu
170910.00 LL capacity of sump @ Thalaisubramaniapuram,
17109.00 LL capacity of sump @ kalinkapatty
17117.00 LL capacity of sump @ Velayuthapuram
17123.50 LL capacity of sump @ Balaarunachalapuram
17133.00 LL capacity of sump @ Kadayanallur & Puliyangudi
17141.50 LL capacity of sump @ Athiyoothu, Surandai and Kadayalurutti
17150.60 LL capacity of sump @ Pudukudi, Sambavarvadakarai
17160.30 LL capacity of sump @ V.K.Pudur, Sangupuram, Mangalapuram & Sivaramapetti Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58434864
AUTHORITY Local Bodies
TENDER VALUE 12.70 Crore
LAST DATE 07-12-2026
Authority
Authority Name Tamil Nadu Water Supply And Drainage Board
Work Description Tender for Operation And Maintenance Of The 2 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12B)
Basic Detail
Tender No Operation and Maintenance of 2 Nos. of CWSS in Tenkasi District Package 12 B
Bidding Type Tender
Location
City Tenkasi
State Tamil Nadu
Key Dates
Publish Date 07 Nov 2026
Submission Date 07 Dec 2026
Open Date 08 Dec 2026
Finance
Tender Value 12.70 Crore
Tender Fee Ref. Documents
EMD 9.53 Lakhs
Exemption Not Available
Document List
04722989-f528-4fd4-9441-67d7fdb436ca.html
BOQ_869168.xls
Tendernotice_1.pdf
TenkasiBid12B.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 30 days
Dec 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 31 days

Tender Documents

Download All (ZIP) ↓
html

04722989-f528-4fd4-9441-67d7fdb436ca.html

xls

BOQ_869168.xls

pdf

Tendernotice_1.pdf

pdf

TenkasiBid12B.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender