Tender For Construction Of Horkab Narzary Guest House At Deulkuchi (G + 1, 15 Rooms With Meeting Hall).
Tender Value
4.83 Crore
Estimated cost
Bid Submission
27 Nov 2026
8 days left
EMD
9.68 Lakhs
Bank guarantee accepted
Document Fee
9700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baksa → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Horkab Narzary Guest House At Deulkuchi (G + 1, 15 Rooms With Meeting Hall).
BOQ
| Sl. No. | Item Description |
| 1 | G+1 GUEST HOUSECIVIL WORKS2.25a Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 2 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 4 | 2.35.3 Treatment of soil under existing floors using chemical emul-sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 5 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 6 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 8 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 9 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.7 Stairs, (excluding landings) except spiral-staircases |
| 11 | 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 4.4.1 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 13 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 14 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu-ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 16 | 5.4 Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 17 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 18 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 20 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 21 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 23 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 24 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) |
| 25 | 6.44 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 26 | 8.10 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. 8.10.1 White Agaria Marble Stone |
| 27 | 9.1 Providing wood work in frames of doors, windows, clerestory windows White Agaria Marble Stone and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood |
| 28 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters |
| 29 | 9.7 Float glass panes 9.7.7.1 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 30 | 9.20 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 31 | 9.71 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete 9.71.1 125x64x2.50 mm |
| 32 | 9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.74.1 250x10 mm |
| 33 | 9.75 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 9.75.1 300x16x5 mm |
| 34 | 9.81 Providing and fixing bright finished brass handles with screws etc. complete: 9.81.1125 mm |
| 35 | 9.82 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 36 | 9.141 Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile.The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer -in- charge. |
| 37 | 9.142 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side),having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner.Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge. 9.142.1 Non decorative finish (matt finish) |
| 38 | 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 39 | 10.26 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube |
| 40 | 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb |
| 41 | 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size, 11.41A.3.1 Size of Tile 600 x 600 mm |
| 42 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 44 | 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 45 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) |
| 46 | 13.9 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 13.9.1 12 mm cement plaster |
| 47 | 13.16 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand) |
| 48 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 49 | 13.45 Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 50 | 13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. 13.42.1 Two or more coats on new work |
| 51 | 13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer |
| 52 | 13.52 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.1 On steel work |
| 53 | 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer. |
| 54 | 21.0 ALUMINIUM WORK 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 55 | 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 56 | 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod ofapproved quality as per architectural drawings and direction ofEngineer-in-charge complete.21.8.1 Upto 5mm depth and 5 mm width |
| 57 | 21.3 Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item):21.3.2 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) |
| 58 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 59 | 10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel. primer, all complete as per the direction of Engineer-In-charge. |
| 60 | 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.1 Light shade pigment using white cement |
| 61 | 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm |
| 62 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes |
| 63 | 12.65 Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or requiredpitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. |
| 64 | 12.66 Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides ofthe sheet and polyester top coat 15-18 microns, using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : 12.66.1 Precoated/mill finish aluminium Ridges plain (500- 600mm) |
| 65 | 11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :11.23.2 Raj Nagar plain |
| 66 | 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 9.3.2 Kiln seasoned and chemically treated hollock wood |
| 67 | 12.26 Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 12.26.2 6 mm thick Cement bonded wood particle board as per IS:14276 |
| 68 | Internal Water Supply & Sanitary Installation12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.2 110 mm diameter |
| 69 | 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.12.42.3 Single tee with door12.42.3.2 110x110x110 mm |
| 70 | 12.42.5 Bend 87.5°12.42.5.2 110 mm bend |
| 71 | 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.18.8.1 15 mm nominal dia Pipes |
| 72 | 18.8.2 20 mm nominal dia Pipes |
| 73 | 18.8.3 25 mm nominal dia Pipes |
| 74 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.18.9.5 40 mm nominal dia Pipes |
| 75 | 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 76 | 17.3 Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 77 | 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 78 | 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 79 | 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.18.52.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 80 | 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.18.50.1 15 mm nominal bore |
| 81 | 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 82 | 17.34 Providing and fixing toilet paper holder :17.34.1 C.P. brass |
| 83 | 17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:17.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 84 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 85 | 17.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 86 | 18.6 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work18.6.4 PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 87 | PN - 10 Pipe, 50 mm OD (SDR-11) |
| 88 | PN - 10 Pipe, 63 mm OD (SDR-11) |
| 89 | PN - 10 Pipe, 75 mm OD (SDR-11) |
| 90 | PN - 10 Pipe, 90 mm OD (SDR-11) |
| 91 | PN - 10 Pipe, 110 mm OD(SDR-11) |
| 92 | Internal Electric Installation Works1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 Group A |
| 93 | 1.55 Wiring for group controlled (looped) light point / fan point / exhaust fan point / call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required,1.55.1 Group A |
| 94 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.1. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 95 | 1.14.2. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 96 | 1.14.3. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 97 | 1.14.4. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 98 | 1.14.10. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 99 | 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.1. 5/6 amps switch |
| 100 | 1.24.3. 15/16 amps switch |
| 101 | 1.24.4. 3 pin 5/6 A socket outlet |
| 102 | 1.24.5. 6 pin 15/16 A socket outlet |
| 103 | 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.1 1 or 2 Module (75mmX75mm) |
| 104 | 1.27.2 3 Module (100mmX75mm) |
| 105 | 1.27.3 4 Module (125mmX75mm) |
| 106 | 1.27.4 6 Module (200mmX75mm) |
| 107 | 1.27.5 8 Module (125mmX125mm) |
| 108 | 1.27.6 12 Module (200mmX150mm) |
| 109 | 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 110 | 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 111 | 1.35 Installation,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 112 | 1.44 Installation,Testing, Commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor, songle core cable etc. as required. |
| 113 | 1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required1.50.1 Upto 450 mm sweep |
| 114 | 1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 115 | 1.58 Supplying and fixing PVC batten / angel holder including connction etc. as required |
| 116 | 2.4 Supplying and fixing following way, horizontal type three pole and neural , sheet steel, MCB distribution board, 415V on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.4.2 6 way (4+18), double door |
| 117 | 2.10 Supplying and fixing 5A to 32A rating, 240/415V 10KA C curve, MCB suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1. Single pole |
| 118 | 2.13 Supplying and fixing following rating, four pole 415V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required.40 A |
| 119 | 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 120 | 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 121 | 6.2 Providing and fixing of lighting arrester conductor finial made of 25mm dia 300mm long GI tube having single prong at top with 85mm dia thick GI base plate including holes etc. complete as required. |
| 122 | 6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For horizontal run) |
| 123 | 6.8 Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lighting conductor complete as required( For vertical run) |
| 124 | MR-1 Supplying of 36W LED tube, Surface/Suspension mounting General Purpose LED Battens in Extruded Aluminium housing with wide range of wattages to suite variety of application areas. IP40. THD: <10%, including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 125 | MR-2 Supplying of 20W LED tube, Surface mounting General Purpose LED Battens in Extruded aluminium housing with wide range of wattages to suite variety of application areas. THD: <10%, including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 126 | MR-3 Supplying of 15 W LED light, slim, pressure die-cast aluminium luminaire in powder coated white finish, ceiling-mounting in square / round profile including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 127 | MR-4 Supplying of 10W LED light, Surface mounting General Purpose LED Battens in Extruded aluminium housing with wide range of wattages to suite variety of application areas including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 128 | MR-5 Supplying of 1200 mm sweep Ceiling Fan with decorative blade or as directed by the Deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 129 | MR-6 Supplying of 300 mm sweep Exhaust Fan etc. as directed by the Deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 130 | MR-7 Supplying,with fitting & fixing of 4 KVA voltage stabilizer of following specification complete with necessary electrical connection etc. as required and as directed by the Department.(Microtec/equivalent) for 1.5 Ton A.C. 4.0 KVA, 140-290 Volt capacity |
| 131 | MR-8 Supplying,with installation of, testing and commi ssioning of Hi wall 5 star rating split inverter air conditioner of following capacity with cord less remote complete with copper pipe and electri cal connection etc. as required complete and as directed by the Department. (Voltus /Blue Star/Carrier Make) etc.1.5 Ton capacity |
| 132 | Power Supply Works11.3 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.11.3.4 Above 10.00 metre and upto 12.00 metre |
| 133 | 13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 134 | 13.2 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 135 | 13.4 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 136 | 13.6 Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. |
| 137 | 13.7 Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 138 | 13.8 Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required |
| 139 | 13.9 Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required |
| 140 | 13.10 Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 141 | 13.11 Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 142 | 13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 143 | 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 144 | 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (for Transformer, DG body earth & pole LA) |
| 145 | 5.4 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (for Transformer & DG neutral earth) |
| 146 | 6.14 Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 147 | 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 148 | 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.7.1.3 Above 95 sq. mm and upto 185 sq. mm |
| 149 | 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.1.27 3 & 1/2 x 185.00 Sq. mm. (57mm) |
| 150 | MR-1 Supplying of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP /Utkarsh / PARUTHI ENGR make) 410 SP 62 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 193.70 x 5.40 mm, Middle =165.10 x 4.50 mm, Top =138.70 x 4.50 mm |
| 151 | MR-2 Supplying and string up ACSR Rabbit conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department. |
| 152 | MR-3 Supplying and fitting fixing of P.G. clamp for Rabbit conductor complete as required and as directed by the department. |
| 153 | MR-4 Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department. |
| 154 | MR-5 Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department. |
| 155 | MR-6 Supply, installation, testing and commissioning of 100 KVA,50Hz, 11/0.433 KV, 3 phase, Oil filled, Off Circuit tap changer, copper wound, out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. |
| 156 | MR-7 Supply of following size XLPE insulated and PVC sheathed 1.1 KV grade Aluminium conductor armoured cable as specified and directed by deptt. (Havells/ polycab/ Gloster/ Finolex make as approved by the deptt.) .185.00 Sq. mm.3 & 1/2 Core armoured U.G. cable |
| 157 | MR-8 Supply, installation, testing & commissioning of Main LT Panel , fully compartmentaliszed cubicle type sheet clad indoor type, wall /floor mounted totally enclosed with IP52 degree of protection suitable for use on 415Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium busbars interconnection etc. with indication lamps, accessories etc. |
| 158 | MR-9 Supplying, Installtion, Testing and Commissioning of the accessories as required complete including payment of ASEB's supervision charge, cost of ASEB's materials etc (including payment of load security and cost of ASEB tested energy trivector Meter) |
| 159 | MR-10 Providing and fixing of 1800 mm long 20 mm dia GI rod earth electrode for individual Pole Earthing |
| 160 | External Electrical Services7.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.7.3.1 Upto 35 sq. mm |
| 161 | 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.1.32 4x10 sq. mm. (25mm) |
| 162 | 5.7 Supplying and laying 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required. |
| 163 | MR-1 Supply of following size XLPE insulated and PVC sheathed 1.1 KV grade Aluminium conductor armoured cable as specified and directed by deptt. (Havells/ polycab/ Gloster/ Finolex make as approved by the deptt.) .4 core 10 sq mm |
| 164 | MR-2 Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 nos foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. Pole Type BOP or equivalent-6030 Height 6m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO , Base Plate:- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join. Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening:- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. (A/ 70 Bottom Dia. (A/ 130, Sheet Thickness 3mm, Base Plate Dimensions (220 x 220 x 12, Foundation Bolt, Bolt Size :- (no. x dia.) 4 x 20 Dia, Pole Foundation :- The octagonal poles shall be bolted on a pre- cast RCC foundation with a set of four foundation bolts for greater rigidity. |
| 165 | MR-3 Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick. Stiffener plate from arm of the following types : Single arm bracket 1000mm long for 6 metre long Poles with boom angel 0 deg. |
| 166 | MR-4 Double arm bracket1000mm long for 6 metre long Poles with 90 deg deflection and boom angel 0 deg. |
| 167 | MR-5 Supply, fixing, testing and commissioning of LED type road light fittings suitable for mounting on 6.0 mtr high octagonal pole complete with all accessories and 40W/45W LED as per specification. Make: Philips / Crompton /Wipro |
| 168 | MR-6 Supplying and drawing of weather proof copper conductor flexible cable of the following size as directed and specified by the department3 core 2.5 Sq.mm unarmoured cable |
| 169 | MR-7 Providing and fixing of 1800 mm long 20 mm dia GI rod earth electrode for individual Pole Earthing |
| 170 | Fire Fighting Works18.1 Supplying, installing, testing and commissioning of Electic driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required:- (A) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520, (B) Suitable HP squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with class-'F' insulation, conforming to IS-325, (C) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required, (D) Suitable cement concrete foundation duly plastered with anti vibration pads.18.1.7 1620 Ipm at 88 m Head |
| 171 | 18.3 Supplying, installing, testing and commissioning of Diesel engine driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required:- (Jockey Pump) (A) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (B) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class pf protection for enclosure, horizontal foot mounted type with Class-'F' insulated, conforming to IS : 325. (C) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required, (D) Suitable cement concrete foundation duly plastered with anti vibration pads.18.3.4 300 Ipm at 88 m Head |
| 172 | 18.6 Providing laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS , refilling the trance etc. of following sizes complete as required.18.6.1 200 mm. dia (wall thickness = 6.3 mm) |
| 173 | 18.6.2 150 mm. dia |
| 174 | 18.7 Providing laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/ IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enael paint of required shade complete as required.18.7.1 25 mm. dia |
| 175 | 18.7.4 50 mm. dia |
| 176 | 18.11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.18.11.6 150 mm. dia |
| 177 | 18.11.7 200 mm. dia |
| 178 | 18.12 Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gunmetal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required.18.12.2 50 mm. dia |
| 179 | 18.12.6 150 mm. dia |
| 180 | 18.13 Supplying and fixing orifice plate made out of 6 mm. thick stainless steel (grade 304) with orifice of required size to be fitted between flance and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 181 | 18.14 Providing, installing, testing and commissioning of non-return valve of following sizes conforming to IS 5312 complete with rubber gaskes, GI bolts, nuts, washers etc as required.18.14.2 50 mm. dia |
| 182 | 18.14.7 150 mm. dia |
| 183 | 18.15 Providing, installing, testing and commissioning of stainless steel Y-strainer fabricated out of 1,6 mm. thick stainless steel, Grade 304, sheet with 3 mm. dia holes with stainless steel flange.18.15.3 150 mm. dia |
| 184 | 18.16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.18.16.1 Gun Metal |
| 185 | 18.19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as required for suitable dia MS pipe connection conforming to IS 904 as required.18.19.1 2 way 100 mm. dia M.S. Pipe |
| 186 | 18.21 Providing, installing, testing and commissioning of 15 mm. dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories.18.21.1 Pendent Sprinkler |
| 187 | INTERNAL DRAIN2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil |
| 188 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 189 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from naturalsources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 190 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 191 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 192 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 193 | 6.26 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand)6.26.1 From ground level upto plinth level |
| 194 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3, (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 195 | DEEP TUBE WELL23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.23.1.1 All types of soil23.1.1.1 300 mm dia |
| 196 | 23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.23.3.2 150 mm nominal size dia |
| 197 | 23.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.23.4.2 150 mm nominal size dia |
| 198 | 23.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 199 | 23.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 200 | 23.6 Supplying, filling, spreading & leveling gravels of size range 1.5 mm to 2 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 201 | 23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. For 84 Hours |
| 202 | 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I)23.15.2 150 mm dia |
| 203 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt.Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel. |
| 204 | BOUNDARY WALL2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 205 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 206 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.6 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 207 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 208 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 209 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 210 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 211 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 212 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 213 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 214 | 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand) |
| 215 | 13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer |
| 216 | 13.45 Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 217 | MAIN GATE2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil |
| 218 | 2.25a Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 219 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 220 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 221 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 222 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 223 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 224 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 225 | 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 226 | 11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 227 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 228 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 229 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 230 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 231 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu-ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 232 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 233 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 234 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 235 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 236 | 6.3 Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :6.3.1 With F.P.S.(non modular) bricks |
| 237 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 238 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters |
| 239 | 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 240 | 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screwsetc. complete :9.96.1 300x16 mm |
| 241 | 9.102 Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 242 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.2 250x10 mm |
| 243 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.4 150x10 mm |
| 244 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.1 125 mm |
| 245 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.2 100 mm |
| 246 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 247 | 10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel. primer, all complete as per the direction of Engineer-In-charge. |
| 248 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 249 | 13.4 12 mm cement plaster of mix :13.4.1 1:4 (1 cement: 4 coarse sand) |
| 250 | 13.16 6 mm cement plaster of mix :13.16.1 1:3 (1 cement : 3 fine sand) |
| 251 | 13.50 Applying priming coat:13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 252 | 13.50.3 With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/ steel works |
| 253 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 254 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @0.75 ltr /10 sqm |
| 255 | 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 256 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 257 | 11.41.A Providing and laying Vitrified tiles in floor in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 258 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 259 | PAVER BLOCK WORK ALONG WITH GATE 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 260 | 16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 261 | 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.1 Light shade pigment using white cement |
| 262 | 16.7 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. 16.7.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 263 | SEPTIC TANK (2 Nos)2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 264 | 16.12.1 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 265 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size |
| 266 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 267 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 268 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 269 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 270 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 271 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 272 | PAVER BLOCK WORKS16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.16.78.2 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 273 | 16.3 Supplying and stacking at site.16.3.2 63 mm to 45 mm size stone aggregate |
| 274 | 16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 275 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 276 | 16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 277 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 278 | 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :4.3.1 Foundations, footings, bases for columns |
| 279 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 280 | DG SETSupply, installation, testing and commissioning of water cooled diesel Generator set coupled to suitable alternator of 25 KVA, 415V, AC, 3-Phase, 50 Hz, 1500 RPM, 0.8 P.F. 3- Cylinder Diesel Engine, Cooling System by Liquid-Cooled on Air- Cooled, mounted on M.S. Fabricated base frame, M.S. fuel tank of required capacity. Residual Silencer, Standard Control Panel. Suitable batteries with lead., First fill of lube oil. Acoustic Enclosure complete with all accessories as specified and directed by the department or as per manufacturer. Kirloskar green/ bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. |
| 281 | Extra for Sunchronizing Panels Wherever required. |
| 282 | FURNITURE & SUPPLY ITEMSMagnolia King Size Bed in Two Tone Finish, Box Storage |
| 283 | Magnolia Queen Size Bed in Two Tone Finish, Box Storage |
| 284 | Turner Solid Wood Single Size Bed, Dark Oak Finish |
| 285 | Salvador 2 Door Wardrobe in Walnut Finish |
| 286 | Stephen Solid Wood Bed Side Table in Dark Oak Finish |
| 287 | Holston Coffee Table in TwoTone Finish |
| 288 | White Floral Printed Polyester Door Curtain, Size 7 Feet |
| 289 | White Cotton Designer Window Curtain, Size: 5 Feet |
| 290 | Stainless Steel Small Dustbin |
| 291 | Jute Floral Foot Mat For Home, For Bathroom, Thickness: 8 mm |
| 292 | Stainless Steel SS Pole Mounted Dual Dustbin for kitchen |
| 293 | Living Room Sofa Set |
| 294 | Premium Notice Board Foam Cushioned Green Fabric |
| 295 | Stylish Reception Table |
| 296 | King Size Jaipuri Print Double Bed Mattress |
| 297 | 8 Inches Pocketed Spring Bed Mattress, Queen Size |
| 298 | 5 Inches Single Bed Mattress |
| 299 | King Size Floral Print PATCHLOOK 100x108 Printed Bed Sheet |
| 300 | Winter Warm Velvet Queen Size Brown Colour Double Bedsheet With 2 Pillow Covers |
| 301 | Pink cotton Sanganeri Printed Single Bedsheets, Size: 60X90 |
| 302 | Premium Soft Pillow |
| 303 | Pillow Covers |
| 304 | Linemates Super Soft Glace Cotton King Size AC Comforter Blanket Duvet Set |
| 305 | BEDCOOUTURE Printed PLUSH SINGLE BED BLANKET |
| 306 | Lushomes Bath Towel |
| 307 | Plastic Bucket |
| 308 | Marina Plastic Mug 1500 |
| 309 | Stainless Steel Soap Dish With Toothbrush Holder, Size: Regular |
| 310 | Stainless Steel Towel Rack |
| 311 | Franceska Solid Wood 4 Seater Dining Set in Burnished Oak Finish |
| 312 | Aquaguard Water Purifiers |
| 313 | Wall Mount Sony Bravia KD-43X74K HD Smart LED TV, 43 inch |
| 314 | Office Table Wooden Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender