Tender For Re Tubing Of Damaged Coolers (Heat Exchangers) At 3 X35 Mw, Ljhp Power House, Baramulla.
Tender Overview
Project Description
Tender for Re Tubing Of Damaged Coolers (Heat Exchangers) At 3 X35 Mw, Ljhp Power House, Baramulla.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Nov-2026 | Corrigendum | Date | 30-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Complete Job of Retubing of Generator Hot Air coolers/heat exchangers of the hydro generators by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 90/10 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power houseTube OD of 19mmTube length of 1.29 mTube thickness 1.5 mmNo. of tubes = 132 |
| 2 | Complete Job of Retubing of Turbine Guide bearings coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming toIS 4503 as per existing ones.The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 90/10 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power houseTube OD of 19mmTube length of 2.06 mTube thickness 1.5 mmNo. of tubes = 60 |
| 3 | Complete Job of Retubing of Transformer coolers/heat exchangers of 14 MVA Generator Transformers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 90/10 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power houseTube OD of 6 mmTube length of 1.29 mTube thickness 1.5 mmNo. of tubes = 180 |
| 4 | Complete Job of Retubing of Thrust Bearing coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. The Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 90/10 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power houseTube OD of 19mmTube of varied length 1.12 m to 0.5 mTube thickness 0.8 mmNo. of tubes = 190 |
| 5 | Complete Job of Retubing of Upper Guide bearing (UGB)coolers/heat exchangers by way of replacement of Cu-Ni tubes by new ones conforming to IS 4503 as per existing ones. TThe Cu-Ni tubes should be of dia with min. thickness of as per IS 4503and chemical composition ofCu-Ni 90/10 conforming to ASTM B171/B171M-18 code. The job includes testing of the coolers at Contractors site and again at power houseTube OD of 19mmTube of length 0.99 m and 0.8 mTube thickness 1.5 mmNo. of tubes = 12 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender