Tender For Construction Of Peurified Water Tank At Jhakua Para Icds Under Baropatia Nutan Bos Gram Panchayat Under Sadar Block Jalpaiguri (Activity Code-145299689)
Tender Value
3.50 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
8 days left
EMD
7001
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Peurified Water Tank At Jhakua Para Icds Under Baropatia Nutan Bos Gram Panchayat Under Sadar Block Jalpaiguri (Activity Code-145299689)
BOQ
| Sl. No. | Item Description |
| 1 | Boring/drilling bore well of required dia for casingl strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 150 metre depth below ground level(i) 50 mm dia. boring etc. |
| 2 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. |
| 3 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 4 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing /casing pipe , removable . |
| 5 | Providing and fixinf MS clamp of required dia ti the top of casting housing pipe of tube well as per 2800(part I ) |
| 6 | Providing and fixing ball plug/bottom plug of required dia to the bottom of pipe assembly of tube well as is 28000 (100mm) |
| 7 | Earthing with 50 mm dia GI pipe 3,64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the groundlevel as below: |
| 8 | Devlopment of tube well in accordance with IS2800and IS 11189 to establis maximum rate of useable water yield without sand contant (beyond)with requred capacity air commpressor. |
| 9 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :(II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. VarietyIn ground floor |
| 11 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost ofcentering, shuttering and finishing:Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 12 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 13 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel |
| 14 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement:4 coarse sand) 1x(2.00+.600)x0.75=1.95 m2 |
| 15 | 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 fine sand) /Item no. 13.2.1 (as per same brick area) 2x.1.95=16.5 |
| 16 | 15MM BID COCK L |
| 17 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete. |
| 18 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank is : 12701 marked …(b)10000litre capacity |
| 19 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass theraded fitting this icludesjoiting of pipes & fitting with one step CPVC solvent cement ... Extarnel work upto Storage tank 25mm nominal dia pipes |
| 20 | Solar Module: Supply, transport, installation and commissioning of ISI marked solar module as per following specification.1. Cell: Indigenous mono crystalline silicon SPV cells.2. Solar Module: Monocrystalline cell with PERC technology/module with bifacial cell3. Standards: ISI marked as per IS 14286 and having certification of IEC 6183(1), 61730(1&2), 617104. Modules must quality to IS 170210(Part 1)5. Min efficiency 19.5% |
| 21 | Cable and Accessories:Supplying, fitting and fixing of UV rated Copper cable laid inside HDPE conduit and other accessories as per following with necessay connection with the Solar PV Module, MPPT etcI. 4.0 Sqmm Single core multi studs-5m (for 1HP/2HP/3HP)ii. Lugs, HDPE Pipe, Flexible pipe, saddle, cable tie etca) For 1HP/2HP/3HP per structure |
| 22 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe including excavation of soil for installation of each electrode and filling & ramming and connection to individual structure to earth electrode including S&F 20mmx3mm galvanized (Hot Dip) MS flat on Wall/floor with |
| 23 | Lighting system a scheme (with lighting Pole)Dusk to dawn lighting arrangement at 4 mts height above ground level, with Hot dip Galvanised 80mmx50mm, medium duty pipe with 12V, 15Ah 2-in-1 Lithium ion/Ferro- Phosphate battery with in-built 7-11 Watt LED lamp, 50 Wp solar panel (min 19% eff.) to cover the scheme area. The lighting system should be warranted for 5years for the date of installation |
| 24 | Lighting protection (Pole mounted): Lighting protection with 3”x1.5” GI pipe of 6m+1m height with base flange in proper RCC foundation and S&F Lighting Conductor Air Terminal made of 20mm dia 1000mm long GI pipe (ISI Medium) having five discharge prongs of 4SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip0 wire and 85 mm dia 6mm thick GI base plate at bottom incl. necessary holes etc. Eating with 65mm dia GI pipe (Medium) 3.0mts long and 1/9/10 stranded GI (Hot Dip) wire (4 mts long) 20mm dia x125mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire crimping sockets/ thimbles and S&F 65mm dia GI Pipe (ISI-Medium) protection (3 mts. Long) to be filled with bitumen partly under the ground level and partly above the ground level to an average depth of 3.65 Mts. Including connection to earth electrodes with 25x6mm GI strips |
| 25 | Supply and Installation of 3 Phase AC electromotor Pump-motor set with speed of 3000 rpm (synchronous speed) suitable for Solar applications and shall have 60 months guarrentee for folloing conditions including loading, unloading, transportation etca) 1 HP 3 phse AC Surface Mounted Monoblock Pump-Motor set as per IS 9079 with discharge of 5.0-6.0 Lps at 8 mts total head with required quantity of flexible deliver pipe (10m), clamps, cable and all other accessories to complete connection of suction and delivery side. |
| 26 | Testing and commissioning of scheme after completion of all work |
| 27 | Testing and commissioning of scheme after completion of all work |
| 28 | Cleaning and washing of modules once in month with clear water to remove diposited dust and dirt on the dodule surface and deep the modules clean throughout the ear. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at the site for the said purpose |
| 29 | Comprehensive maintenance charges for 5 years (which cover onthly inspection, Yearly training to WUA, to atted breakdown within 3 days and to keep the scheme in operation without lapse of time)a) for 2 HP both for submersible & Surface pump |
| 30 | le Mounting Structure:Supply, transportation & Installation of GI manual tracking/Fixed structure made of MS Hollow Section, Pipes, Plates, angles etc as per IS4923, IS:1161/1239, IS:1079/2062, to hold min 300Wp SPV Module as per drawing and technical specification. The steel structure is to be protected with minimum 80 micron galvanization (hot dip) and provided with fixed arrangement of dual axis manual tracking arrangement for three times in a day and seasonal lilting to face the sun optimally. |
| 31 | conditioning unit with enclosure:Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.12. Power input: DC source for 1HP, 2HP and 3HP3. Power input: AC/DC source or hybrid for 5HP and above4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-25. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-26. Type II DC SPD of 40 KA7. Type II AC SPD 40 KA for AC/DC or Hybrid input8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP |
| 32 | correction factor |
| 33 | GST 18% |
| 34 | cess 1 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender