Tender For Construction Of 40 Nos. Of E-Type Staff Qrs. (Block-I (S+3) And Block-Ii (S+2)) At Parlakhemundi, Gajapati.
Tender Value
13.51 Crore
Estimated cost
Bid Submission
16 Nov 2026
8 days left
EMD
13.51 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gajapati → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 40 Nos. Of E-Type Staff Qrs. (Block-I (S+3) And Block-Ii (S+2)) At Parlakhemundi, Gajapati.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKProviding jungle cutting uprooting buses below 1.00m girth with cost of all labour and T&P required for the work etc. complete as directed by the Engineer- in- charge.Stilt Floor (S+3) |
| 2 | Stilt Floor (S+2) |
| 3 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.Stilt Floor (S+3) |
| 4 | Stilt Floor (S+2) |
| 5 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. Stilt Floor (S+3) |
| 6 | Stilt Floor (S+2) |
| 7 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge.Stilt Floor (S+3) |
| 8 | Stilt Floor (S+2) |
| 9 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge. Stilt Floor (S+3) |
| 10 | Stilt Floor (S+2) |
| 11 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 40mm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.Stilt Floor (S+3) |
| 12 | Stilt Floor (S+2) |
| 13 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 12mm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.Stilt Floor (S+3) |
| 14 | Stilt Floor (S+2) |
| 15 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.S+3Stilt FloorFooting :- |
| 16 | Column up to Pl Lvl :- |
| 17 | Tie/Plinth Beam :- |
| 18 | COLUMN UP TO ROOF LEVEL :-S+3Stilt Floor |
| 19 | First Floor |
| 20 | Second Floor |
| 21 | Third Floor |
| 22 | Terrace Floor |
| 23 | LINTEL :-Stilt Floor |
| 24 | First Floor |
| 25 | Second Floor |
| 26 | Third Floor |
| 27 | Terrace Floor |
| 28 | ROOF BEAM :-Stilt Floor |
| 29 | First Floor |
| 30 | Second Floor |
| 31 | Third Floor |
| 32 | Terrace Floor |
| 33 | ROOF SLAB :-Stilt Floor |
| 34 | First Floor |
| 35 | Second Floor |
| 36 | Third Floor |
| 37 | Terrace Floor |
| 38 | STAIRCASE :-Stilt Floor |
| 39 | First Floor |
| 40 | Second Floor |
| 41 | Third Floor |
| 42 | LIFT :-Stilt Floor |
| 43 | First Floor |
| 44 | Second Floor |
| 45 | Third Floor |
| 46 | CHAJJA :-First Floor |
| 47 | Second floor |
| 48 | Third floor |
| 49 | S+2Stilt Floor Footing :- |
| 50 | Column up to Pl lvl :- |
| 51 | Tie/Plinth Beam :- |
| 52 | COLUMN UP TO ROOF LEVEL :- Stilt Floor |
| 53 | First Floor |
| 54 | Second Floor |
| 55 | Terrace Floor |
| 56 | LINTEL :-Stilt Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Terrace Floor |
| 60 | ROOF BEAM :-Stilt Floor |
| 61 | First Floor |
| 62 | Second Floor |
| 63 | Terrace Floor |
| 64 | ROOF SLAB :-Stilt Floor |
| 65 | First Floor |
| 66 | Second Floor |
| 67 | Terrace Floor |
| 68 | STAIRCASE :-Stilt Floor |
| 69 | First Floor |
| 70 | Second Floor |
| 71 | LIFT :-Stilt Floor |
| 72 | First Floor |
| 73 | Second Floor |
| 74 | CHAJJA :-First Floor |
| 75 | Second floor |
| 76 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.S+3Stilt Floor |
| 77 | First Floor |
| 78 | Second Floor |
| 79 | Third Floor |
| 80 | Terrace Floor |
| 81 | S+2Stilt Floor |
| 82 | First Floor |
| 83 | Second Floor |
| 84 | Terrace Floor |
| 85 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Stilt Floor (S+3) |
| 86 | Stilt Floor (S+2) |
| 87 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.S+3Stilt Floor |
| 88 | First Floor |
| 89 | Second Floor |
| 90 | Third Floor |
| 91 | Terrace Floor |
| 92 | S+2Stilt Floor |
| 93 | First Floor |
| 94 | Second Floor |
| 95 | Terrace Floor |
| 96 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.S+3First Floor |
| 97 | Second Floor |
| 98 | Third Floor |
| 99 | S+2First Floor |
| 100 | Second Floor |
| 101 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. S+3Stilt Floor |
| 102 | First Floor |
| 103 | Second Floor |
| 104 | Third Floor |
| 105 | Terrace Floor |
| 106 | S+2Stilt Floor |
| 107 | First Floor |
| 108 | Second Floor |
| 109 | Terrace Floor |
| 110 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. S+3Stilt Floor |
| 111 | First Floor |
| 112 | Second Floor |
| 113 | Third Floor |
| 114 | Terrace Floor |
| 115 | S+2Stilt Floor |
| 116 | First Floor |
| 117 | Second Floor |
| 118 | Terrace Floor |
| 119 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.S+3Stilt Floor |
| 120 | First Floor |
| 121 | Second Floor |
| 122 | Third Floor |
| 123 | S+2Stilt Floor |
| 124 | First Floor |
| 125 | Second Floor |
| 126 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON /RAK/ KAJARIA) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.S+3Stilt Floor |
| 127 | First Floor |
| 128 | Second Floor |
| 129 | Third Floor |
| 130 | S+2Stilt Floor |
| 131 | First Floor |
| 132 | Second Floor |
| 133 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.S+3Stilt Floor |
| 134 | First Floor |
| 135 | Second Floor |
| 136 | Third Floor |
| 137 | S+2Stilt Floor |
| 138 | First Floor |
| 139 | Second Floor |
| 140 | Fixing granite stone of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.S+3Stilt Floor |
| 141 | First Floor |
| 142 | Second Floor |
| 143 | Third Floor |
| 144 | S+2Stilt Floor |
| 145 | First Floor |
| 146 | Second Floor |
| 147 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.S+3Stilt Floor |
| 148 | First Floor |
| 149 | Second Floor |
| 150 | Third Floor |
| 151 | S+2Stilt Floor |
| 152 | First Floor |
| 153 | Second Floor |
| 154 | Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.Stilt Floor (S+3) & (S+2) |
| 155 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 as per direction of the Engineer-in-charge.Stilt Floor (S+3) & (S+2) |
| 156 | Providing and fixing of WPC door frames with rebate cuts and finished cross section size 75mm x 45mm or 90mm x 50mm, including cost of all materials, cost of all labour conveyance, taxes, loading, unloading scaffolding, slaging watering and curing, T&P, etc, complete as per the direction of the Engineer-in-charge.(Make-Green Land / Century/ Alstone)S+3First Floor |
| 157 | Second Floor |
| 158 | Third Floor |
| 159 | Terrace Floor |
| 160 | S+2First Floor |
| 161 | Second Floor |
| 162 | Terrace Floor |
| 163 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.S+3First Floor |
| 164 | Second Floor |
| 165 | Third Floor |
| 166 | Terrace Floor |
| 167 | S+2First Floor |
| 168 | Second Floor |
| 169 | Terrace Floor |
| 170 | Supplying and installing UPVC-3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with Smm reflective toughened glass of make Saint gobain/AIS/Goldplus The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning/GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge. (Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance)S+3Stilt Floor |
| 171 | First Floor |
| 172 | Second Floor |
| 173 | Third Floor |
| 174 | S+2Stilt Floor |
| 175 | First Floor |
| 176 | Second Floor |
| 177 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA/ NCL VEKA LTD.). Ventilator/ Top Hung-60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM, weathering seal resistant accessories, like clipping Jocking system tone including cost and conveyance of all materials, accessories, labour charges, materials Nuotiosoite pine thermobninstalled at the nonaktsmeners, silicon rubber sealant, easy glazing/deglazing at site etc..and product conforming to ASTM D 638-14.EN-477-95 and other applicable codes and standards.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance)S+3Stilt Floor |
| 178 | First Floor |
| 179 | Second Floor |
| 180 | Third Floor |
| 181 | Terrace Floor |
| 182 | S+2Stilt Floor |
| 183 | First Floor |
| 184 | Second Floor |
| 185 | Terrace Floor |
| 186 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.S+3Stilt Floor |
| 187 | First Floor |
| 188 | Second Floor |
| 189 | Third Floor |
| 190 | Terrace Floor |
| 191 | S+2Stilt Floor |
| 192 | First Floor |
| 193 | Second Floor |
| 194 | Terrace Floor |
| 195 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).S+3Stilt Floor |
| 196 | First Floor |
| 197 | Second Floor |
| 198 | Third Floor |
| 199 | Terrace Floor |
| 200 | S+2Stilt Floor |
| 201 | First Floor |
| 202 | Second Floor |
| 203 | Terrace Floor |
| 204 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).S+3Stilt Floor |
| 205 | First Floor |
| 206 | Second Floor |
| 207 | Third Floor |
| 208 | Terrace Floor |
| 209 | S+2Stilt Floor |
| 210 | First Floor |
| 211 | Second Floor |
| 212 | Terrace Floor |
| 213 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).S+3Stilt Floor |
| 214 | First Floor |
| 215 | Second Floor |
| 216 | Third Floor |
| 217 | Terrace Floor |
| 218 | S+2Stilt Floor |
| 219 | First Floor |
| 220 | Second Floor |
| 221 | Terrace Floor |
| 222 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).S+3Stilt Floor |
| 223 | First Floor |
| 224 | Second Floor |
| 225 | Third Floor |
| 226 | Terrace Floor |
| 227 | S+2Stilt Floor |
| 228 | First Floor |
| 229 | Second Floor |
| 230 | Terrace Floor |
| 231 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ).S+3Stilt Floor |
| 232 | First Floor |
| 233 | Second Floor |
| 234 | Third Floor |
| 235 | S+2Stilt Floor |
| 236 | First Floor |
| 237 | Second Floor |
| 238 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.S+3Third Floor |
| 239 | Fourth floor |
| 240 | S+2Second Floor |
| 241 | Third Floor |
| 242 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.S+3Stilt Floor |
| 243 | First Floor |
| 244 | Second Floor |
| 245 | Third Floor |
| 246 | Terrace Floor |
| 247 | S+2Stilt Floor |
| 248 | First Floor |
| 249 | Second Floor |
| 250 | Terrace Floor |
| 251 | E.I. WORKSub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB: 2way switch shall be used for living room for controlling room light and fan adjacent to bed.Each lightpoint should have provision for ceiling rose and angle holder point. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter.There shall be separate switchboard for inverter points and raw points.All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A |
| 252 | GROUP-B |
| 253 | GROUP-C |
| 254 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 255 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 256 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 257 | Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 258 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 259 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 260 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 261 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 10 sq. mm copper wire for phase and neutral and 01 no of single core 6 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit . (2x10+1X6) |
| 262 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit (2X6+1X4) |
| 263 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 264 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 265 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 266 | Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 267 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 268 | S/F of 5 step type Modular electronic Fan Regulator anti bacterial ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) |
| 269 | SITC Of 4Ft surface mounted/suspended Single Piece Constructed CRCA LED TUBE BATTEN required pre-wired terminal one side with body earthing provision - along with mounting of 1No.s Essential Glass T8 Base Tube 2200Lumen Pack,Efficacy >110Lm/W, 20Watt,CRI >=80, PF >0.9, CCT 4K, IP20, 25K Burning Hours Temp -20To45Degree,CE marking RoHS compliance KEMA Keur certificate.(Make: Panasonic/LT/Havells /Philips((TMC502 1xT-LED 22W))/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years. |
| 270 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 271 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 272 | HYBRID SOLAR FOR COMMON AREASupply Installation Testing and Commissioning of 2.5 kVA hybrid Solar Photovoltaic Power Plant having following provision: 6 nos. of panel , C-10 Lead acid solar battery 200Ah , 12 V- 4 Nos. conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT Crystalline silicon solar cells,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency..d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc.asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years. |
| 273 | BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (RAW DB) |
| 274 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (INVERTER DB) |
| 275 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 276 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 277 | Supplying and fixing 63Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 278 | Supplying and fixing 32Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 279 | Supplying and fixing 32 Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 280 | (Earthing) INSTALLATIONSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 281 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 282 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 283 | CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 120 sq mm |
| 284 | 3.5core x 70 sq mm |
| 285 | 4 core x 16 sqmm |
| 286 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 287 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM and not exceeding 120 sqmm direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 288 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 289 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.4 core x16 sq mm |
| 290 | 3.5core x 120 sq mm |
| 291 | 3.5core x 70 sq mm |
| 292 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia |
| 293 | PANELS S/I/T&Commissioning of Main LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 40X10MM Separate Aluminium Earth bus bar should be installed..1 nos of 3P+N Type 1+2 SPD 50kA/pole with 600A HRC Backup fuse shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders.Make of SPD- ABB/OBO/DEHN. In commer-1-01 number of 250A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula, Busbar- 04 numbers of 300Amps aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. , Out going- (i) 27 numbers of 63A rating,10 KA breaking capacity,C series, DP MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) With 12 Nos 1 Phase Energy Meter. , Out going- (ii) 02 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics 2 nos. with space for 2 nos. 3ph KWH Meter digital type( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB-FORMULA), Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data., (iv) All the incoming and outgoing feeders shall have ON/OFF/TRIP indication., |
| 294 | Changeover panelS/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.1 nos of 3P+N Type 1+2 SPD 50kA/pole with 600A HRC Backup fuse shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders.Make of SPD- ABB/OBO/DEHN. 125A 4P ON Load changeover switch( ( Make-LEGRAND/ Siemens/ Schneider/ABB), Busbar- 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) , Out going- (iii) 63A 4P MCCB rating,16 KA breaking capacity with TMR based release(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 03 nos along with space for 3 Phase KWH meter for LIFT ., Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 2 nos with space for 2 nos 10-100A 1PH KWH Meter digital type for each quarter . |
| 295 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 296 | LIGHTNING PROTECTIONSupply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 297 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 298 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 299 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 300 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/ expansion piece ). Make-OBO/Dehn/ABB |
| 301 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 302 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 303 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 304 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 305 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 306 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 307 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 308 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 309 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 310 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 311 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 312 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 313 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP testedMake-OBO/Dehn/ABB |
| 314 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system.Make-OBO/Dehn/ABB |
| 315 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 316 | EXTERNAL ILLUMINATION WORK (SOLAR STREET LIGHT)Supply of Elegant look 60 W(>=190lm/W) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 317 | SITC of 8 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos. Jtype En 8 grade foundation bolts to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the pole.The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 nos 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.The reports are to be duly approved by the competant authority from civil wing (concerned SE/CCE/Competant authority) before execution of the work.The structural design of the pole foundation shall be approved by concerned civil wing(SE/CCE/Competant authority) before execution of the work.(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh) |
| 318 | Construction of RCC foundation by using M20gradeRCC and Fe415 grade reinforcementin the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation for installation of pole with solar lighton that foundation.The work shall be executed as per the instruction of EIC . |
| 319 | Sub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB: 2way switch shall be used for living room for controlling room light and fan adjacent to bed.Each lightpoint should have provision for ceiling rose and angle holder point. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter.There shall be separate switchboard for inverter points and raw points.All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A(QTRS) |
| 320 | GROUP-B(QTRS) |
| 321 | GROUP-C(COMMON AREA) |
| 322 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 323 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 324 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 325 | Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 326 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 327 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 328 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 329 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 10 sq. mm copper wire for phase and neutral and 01 no of single core 6 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit . (2x10+1X6) |
| 330 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit (2X6+1X4) |
| 331 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 332 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 333 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 334 | Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 335 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 336 | S/F of 5 step type Modular electronic Fan Regulator anti bacterial ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) |
| 337 | SITC Of 4Ft surface mounted/suspended Single Piece Constructed CRCA LED TUBE BATTEN required pre-wired terminal one side with body earthing provision - along with mounting of 1No.s Essential Glass T8 Base Tube 2200Lumen Pack,Efficacy >110Lm/W, 20Watt,CRI >=80, PF >0.9, CCT 4K, IP20, 25K Burning Hours Temp -20To45Degree,CE marking RoHS compliance KEMA Keur certificate.(Make: Panasonic/LT/Havells /Philips((TMC502 1xT-LED 22W))/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years. |
| 338 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 339 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 340 | HYBRID SOLAR FOR COMMON AREASupply Installation Testing and Commissioning of 2.5 kVA hybrid Solar Photovoltaic Power Plant having following provision: 6 nos. of panel , C-10 Lead acid solar battery 200Ah , 12 V- 4 Nos. conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT Crystalline silicon solar cells,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency..d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc.asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years. |
| 341 | BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (RAW DB) |
| 342 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (INVERTER DB) |
| 343 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 344 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 345 | Supplying and fixing 63Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 346 | Supplying and fixing 32Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 347 | Supplying and fixing 32 Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 348 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 349 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 350 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 351 | CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 120 sq mm |
| 352 | 3.5core x 70 sq mm |
| 353 | 4 core x 16 sqmm |
| 354 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 355 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM and not exceeding 120 sqmm direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 356 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 357 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4 core x16 sq mm |
| 358 | 3.5core x 120 sq mm |
| 359 | 3.5core x 70 sq mm |
| 360 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia |
| 361 | PANELS S/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.1 nos of 3P+N Type 1+2 SPD 50kA/pole with 600A HRC Backup fuse shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders.Make of SPD- ABB/OBO/DEHN. In commer - 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula. Busbar- 04 numbers of 300Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) , Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 18 nos with space for 18 nos 10-100A 1PH KWH Meter digital type for each quarter . Out going- (ii) 02 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics 2 nos. with space for 2 nos. 3ph KWH Meter digital type( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB-FORMULA), Instrument- (i) phase indicating lamp with toggle switch & HRC fuse for all incomers, (ii) digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication for all incomers. |
| 362 | Changeover panelS/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.1 nos of 3P+N Type 1+2 SPD 50kA/pole with 600A HRC Backup fuse shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders.Make of SPD- ABB/OBO/DEHN. 125A 4P ON Load changeover switch( ( Make-LEGRAND/ Siemens/ Schneider/ABB). Busbar- 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing), Out going- (iii) 63A 4P MCCB rating,16 KA breaking capacity with TMR based release(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 03 nos along with space for 3 Phase KWH meter for LIFT ., Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 2 nos with space for 2 nos 10-100A 1PH KWH Meter digital type for each quarter . . |
| 363 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 364 | LIGHTNING PROTECTIONSupply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 365 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 366 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 367 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 368 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 369 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 370 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 371 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 372 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 373 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 374 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 375 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 376 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 377 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 378 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 379 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 380 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 381 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 382 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 383 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 384 | EXTERNAL ILLUMINATION WORK (SOLAR STREET LIGHT)Supply of Elegant look 60 W(>=190lm/W) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 385 | SITC of 8 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos. Jtype En 8 grade foundation bolts to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the pole.The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 nos 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.The reports are to be duly approved by the competant authority from civil wing (concerned SE/CCE/Competant authority) before execution of the work.The structural design of the pole foundation shall be approved by concerned civil wing(SE/CCE/Competant authority) before execution of the work.(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh) |
| 386 | Construction of RCC foundation by using M20gradeRCC and Fe415 grade reinforcementin the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation for installation of pole with solar lighton that foundation.The work shall be executed as per the instruction of EIC . |
| 387 | P.H. WORKSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge. 1st Floor 20mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 388 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 389 | 2nd Floor 20mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 390 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 391 | 3rd Floor 20mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 392 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst) |
| 393 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm PVC ASTM Pipe |
| 394 | 32mm PVC ASTM Pipe |
| 395 | 1st Floor 25mm PVC ASTM Pipe |
| 396 | 32mm PVC ASTM Pipe |
| 397 | 2nd Floor 25mm PVC ASTM Pipe |
| 398 | 32mm PVC ASTM Pipe |
| 399 | 3rd Floor 25mm PVC ASTM Pipe |
| 400 | 32mm PVC ASTM Pipe |
| 401 | 40mm PVC ASTM Pipe |
| 402 | 50mm PVC ASTM Pipe |
| 403 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.1st Floor |
| 404 | 2nd Floor |
| 405 | 3rd Floor |
| 406 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge1st Floor |
| 407 | 2nd Floor |
| 408 | 3rd Floor |
| 409 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall 1st Floor |
| 410 | 2nd Floor |
| 411 | 3rd Floor |
| 412 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge15mm dia CP Bib cock (FLR-CHR-5047N Jaquar make) |
| 413 | 15 mm dia CP Long body Bib cock(Jaquar)CON-CHR-049NKN |
| 414 | 15mm dia CP angle stop cock (FLR-CHR-5053N Jaquar make) |
| 415 | 20mm dia CP Con. stop cock (CON-CHR-089KN) |
| 416 | 15mm dia CP Pillar cock (FLR-chr-5011N Jaquar make) |
| 417 | 15mm dia CP two in one bib cock (FLR-CHR-5041N Jaquar make) |
| 418 | 15mm dia CP Health faucet (ALD-CHR-573 Jaquar make) |
| 419 | 15mm dia CP Sink Cock (FLR- CHR- 5347 NJaquar make) |
| 420 | Revolving Shower with arm Jaquar Cat NO--OHS-CHR-1985 + SHA-CHR-477 |
| 421 | 25mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 422 | 32mm dia brass or gun metal fullway valve(Leader / KritiMake) |
| 423 | 40mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 424 | 50mm dia brass or gun metal fullway valve(Leader / Kriti Make) |
| 425 | 15mm dia CP flange |
| 426 | 15mm dia CP extension piece |
| 427 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 litre capacity water storage Sintex tank on the roof of 2nd floor. |
| 428 | On the roof of 3rd floor. |
| 429 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge . 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Hindware / Parryware Make) |
| 430 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 431 | 75mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 432 | 100mm dia U-PVC 'P' trap |
| 433 | 110mm dia U-PVC Door Tee |
| 434 | 100mm dia U-PVC Plain Bend |
| 435 | 100mm dia U-PVC Door Bend |
| 436 | 100mm U-PVC Door Cross Tee |
| 437 | 75mm dia U-PVC Door Bend. |
| 438 | 75mm dia U-PVC Plain Bend. |
| 439 | 110x75mm dia Reducer |
| 440 | 110mm dia Vent cowl. |
| 441 | W/C connector |
| 442 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 443 | 125mm dia CP grating |
| 444 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of (Parryware/Hindware/Cera/Somany/Kerovit) with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge.EWC with 'S' trap plain with seat cover (Parryware/ Hindware) |
| 445 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware) |
| 446 | 550mmx440 mm size wash hand basin (Without porcelain pedestal) (Parryware/Hindware) |
| 447 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 448 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf 600mm long(ACN-CHR-1171N) |
| 449 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mm x 600mm long CP towel rail (Jaquar) ACN-CHR-1111SM |
| 450 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 451 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P(Jaquar make) |
| 452 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink With sink cock with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge 600x450x250 mm SS sink(With drain board -NIRALI) |
| 453 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 1st Floor |
| 454 | 2nd Floor |
| 455 | 3rd Floor |
| 456 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. 1st Floor 8x2x2x(2.27+1.22)x2.1 |
| 457 | 2nd Floor |
| 458 | 3rd Floor |
| 459 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.1st Floor Wall |
| 460 | 2nd Floor Wall |
| 461 | 3rd Floor Wall |
| 462 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 30 cm x 45 cm1st Floor Toilet |
| 463 | 2nd Floor Toilet |
| 464 | 3rd Floor Toilet |
| 465 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 30 x 30 cm Kajaria / equvalent to be pree approved .1st Floor |
| 466 | 2nd Floor |
| 467 | 3rd Floor |
| 468 | Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge (Rajshri plastiwood/Alstone/Aramstrong or equivalent as per direction of Engineer-in-charge) |
| 469 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour brown/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. (Rajshri plastiwood/Alstone/Aramstrong or equivalent as per direction of Engineer-in-charge) |
| 470 | Louvers |
| 471 | EXTERNAL P.H. WORK.:-Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm all round concrete |
| 472 | 160mm all round concrete |
| 473 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
| 474 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 600mmx600mmx450mm |
| 475 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeMan hole chamber Inside size 910mmx910mmx910mm |
| 476 | Cost of R.C.P.C.Cover. |
| 477 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeBrick masonry soakway pit 1.40m dia x 2.10m deep |
| 478 | Construction of 50 users RCC septic tank-2 Nos :-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 479 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 480 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 481 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 482 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 483 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor (inside/outside) |
| 484 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor (inside/outside) |
| 485 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.R.C.C floor and roof slabs up to 4.30m height |
| 486 | R.C.C beams,columns,girder and bressmer etc. |
| 487 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In Ground Floor per 0.80 qtl/cum |
| 488 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 489 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 490 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 491 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn F&PB.Wall |
| 492 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. 2x6 nos |
| 493 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 494 | Supplying all materials, labour,T&P and providing 25mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips on new work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 495 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 496 | Dewatering with 5 H.P diesel engine pump during excavation 2nosx 30 hours |
| 497 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 150mx150mx150m as per P.H.D.specification and direction of the E.I.C. |
| 498 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 499 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 500 | 110mm U-PVC cowl |
| 501 | Construction of 100 users RCC septic tank- (I/S size-5.70mx2.10mx2.40m)-30cm wide wallEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 502 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 503 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 504 | Supplying all materials, labour, T&P and providing dewatering water from pit using 5 HP disel pump set etc.all complete as per specification and direction of the Engineer in charge |
| 505 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 506 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 507 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to 4.30m height |
| 508 | R.C.C beams, columns, girder and bressmer etc--In G.F |
| 509 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 510 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 511 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn foundation and plinth |
| 512 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 513 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn Ground floor |
| 514 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 515 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 516 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.Making MS step iron in 20mm diameter MS steel bars |
| 517 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 518 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 519 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 520 | 110mm dia U-PVC Plain shoe bend |
| 521 | 110mm U-PVC cowl |
| 522 | Sinking of (200 x150)mm dia bore well - 2 Nos by DTH method :-Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below first level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only.Drilling of 200mm dia bore 00 mtr to 45mtr |
| 523 | Drilling of 150mm dia bore 45 mtr to 150mtr |
| 524 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from first level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia P.V.C casing pipes00 mtr to 45 mtrs |
| 525 | Cost of 200mm dia PVC (sch-80) pipe |
| 526 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge.By DTH Rig |
| 527 | Supplying all materials, labour, T&P for withdrawing casing pipes from the unsuccessful bore well including all necessary equipment and labour as per direction of the Engineer in charge . |
| 528 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 529 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm |
| 530 | DOL controll pannel |
| 531 | 2.5 Sqmm flat cable |
| 532 | 32mm dia Steel short piece |
| 533 | Steel roop with cover |
| 534 | Well cap |
| 535 | 50mm size CI bracket |
| 536 | 20mm dia rigid UPVC pipe |
| 537 | 32mm Dia brass non return valve(Shakti make) |
| 538 | 32mm dia HDPE pipe |
| 539 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 540 | Construction of 6.75mx3.60m x 1.40m(h) Rain water harvesting system 2nos :-Sinking of tube well through D.T.H.Rig.200mm dia- 0.0m to 30.00m (4x25 mtrs) |
| 541 | Lowering of PVC casing pipe inside bore.200mm dia- 0.0m to 30.00m (4x25 mtrs) |
| 542 | Cost.of 200mm dia (Sch.80)Pipe (4x25 mtrs) |
| 543 | Cutting slot in casing pipe for recharge of rain water (4x25 mtrs) |
| 544 | Labour for packing gravel outside the tube well2x25.0mx22/28{(0.40)²-(0.20)²} |
| 545 | Cost of washed gravel. |
| 546 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 547 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 548 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 549 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 550 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 551 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 552 | Supplying all materials, labour, T&P and providing reinforced cement concrete work of M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 553 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. 0.85% |
| 554 | Providing and filling filter media40mm size bolder-2x6.0x2.50x0.85 |
| 555 | 20mm size washed gravel-2x6.0x2.50x0.40 |
| 556 | Course sand-2x6.0x2.50x0.30 |
| 557 | Providing fitting and fixing M.S.grill,Jalli cover over the harvesty pindi |
| 558 | Supplying all materials, labour, T&P and constructing surface drain of size A-4 type with cement concrete (1:3:6) using 12mm size h.g chips on bed, 1st class K.B brickwork in cement mortar (1:3) inside, 12mm thick cement plaster (1:3) finished smooth with cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 559 | 30000 Ltrs.Capacity Under Ground Reservier. :-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 560 | Initial lift |
| 561 | Excavation of foundation in laterite rock or any hard rock (other than granite) including dressing and leveling the bed and depositing the soil as per specification approved by the Department. |
| 562 | Supplying all materials, labour, T&P and filling in foundaton and plinth with sand well watered and rammed including conveyeance of all materials to worksite,payment of royalty, taxes etc all complete as per direction of the Engineer in charge. |
| 563 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site. |
| 564 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 565 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.1.00 qtl per cum |
| 566 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.RCC Walls |
| 567 | RCC Slab |
| 568 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:3) including watering,curring and conveyance of all materials to site.Inside/outside portion |
| 569 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 570 | Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender