Tender For Roof Treatment And Other Hazards Repair Work In Govt. Model Middle School Sector 56, Chandigarh
Tender Value
44.05 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
5 days left
EMD
88111
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Roof Treatment And Other Hazards Repair Work In Govt. Model Middle School Sector 56, Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (As per DSR 4.1.10) |
| 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (As per DSR 6.4.1) |
| 3 | Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : (copper oxidized as per IS: 1378) 115 mm (As per DSR 9.67.2) |
| 4 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. (As per DSR 9.84) |
| 5 | Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type) (As per DSR 9.114.2) |
| 6 | Welding by gas or electric plant including transportation of plant at site etc. complete. (As per DSR 10.22) |
| 7 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand): 25 mm thick (As per DSR 11.26.1) |
| 8 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size Size of Tile 600x600 mm (As per DSR 11.41A.1.1) |
| 9 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (As per DSR 12.21.1) |
| 10 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (As per DSR 12.22) |
| 11 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (As per DSR 12.44) |
| 12 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 Fine sand) (As per DSR 13.2.1) |
| 13 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) (As per DSR 13.16.1) |
| 14 | Pointing on brick work with cement mortar (1:3) : Flush / Ruled/ Struck or weathered pointing (As per DSR 13.31.1) |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm). (As per DSR 13.46.1) |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (As per DSR 13.80) |
| 17 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete. (As per DSR 13.91) |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (As per DSR 13.99.1) |
| 19 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. (As per DSR 13.41.1) |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (As per DSR 13.62.1) |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm). (As per DSR 13.111.2) |
| 22 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (As per DSR 14.5.1) |
| 23 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (As per DSR 15.25) |
| 24 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.15.7.4 In cement mortar (As per DSR 15.7.4) |
| 25 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (As per DSR 15.56) |
| 26 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (As per DSR 15.60) |
| 27 | Providing and laying double charge vitrified floor tiles of specified size (thickness to be specified by the manufacturer) of 1st quality with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. (N.S.) |
| 28 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board in existing steel frames well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (N.S.) |
| 29 | Providing and fixing of cupboard shutter consisting of 19mm thick commercial board with lipping all around and fixed with chowkhat frame with piano hinges and screws etc. and provide with Alum. handle (with base plate) and magnetic catcher. The board surface is to be painted with two coats of special quality synthetic enamel paint after primer coat and preparation of surface, complete frame is to be fixed with iron nails etc. complete in all respects and to the entire satisfaction ofthe Engineer in charge. (N.S.) |
| 30 | Repair of deteriorated RCC Balconies, Chajjas, Beams, Walls, Ceiling, Column or other concrete surface having exposed rusted bars consisting of following operations (a) chipping of concrete surface 25mm thick average depth afterwards remocal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. (b) Moistening the surface properly and applying arcylic polymer (acrocrete/ pidilite/ mastercrete or its equivalent) coating mixed with cement for proper bonding of old and new concrete in two coats 0.2kg per 1kg of cement. (c) Providing and fixing chicken mesh of standard size and 26 guage with steel reinforcement by using binding wire and nails complete. (d) Proving and placing of cement concrete l:11/2:3 having average thickness 1\\" (3/4\\" to 11/4\\" thick) mixed with arcylic polymer admixture @ 1kg per bag of cement and waterproof agent @ 400ml per 2 bags of cement including finishing the surface complete in all respect as per the direction and to the entire satisfaction of Engineer-in-Charge. (N.S.) |
| 31 | Providing and fixing 60 mm thick high density rubber moulded precast cement concrete paver block grey/ colored/ polished/ designer (manufactured by vibro hydraulic pressure process) consisting of design mix of cement, sand and fine aggregate having designation M35 ISI marked including the cost of good quality color and hardening agents. The paver should be compiled with tensile strength and breaking load as per BIS 6717-1993 and shall be tested against resistance to bear as per IS 1237-1980 (specification for cement concrete floor tiles). The paver should be laid over layer of 50mm average thick sand to the required slope and requirement complete in all respects and to the entire satisfaction of Engineer in charge. (N.S.) |
| 32 | Providing and fixing of factory manufactured pre-cast concrete kerb of size 300mm X 300mm having 150 mm thickness with one edge semi rounded duly vibrated mechanically and compacted made of P.C.C. 1:2:4 duly cured and finished. the rate further include filling of joints between kerbs/ channels with cement mortar 1:2 complete in all respect and to the entire satisfaction of Engineer-in-charge. (N.S.) |
| 33 | Providing and fixing IRC welded mesh 25mm x 25mm in M.S. angle frame of 30x30x3mm and M.S. flat 20x5mm on the inner side including cost of cutting welding, fixing the complete frame in the exisitng brick / RCC structure with 3\\" long 8 nos. fasteneres including painting two coats of synthetic enamel paint over one coat of metal primer complete in all respects and to the entire satisfaction of the Engineer in charge. (N.S.) |
| 34 | Cleaning of kota stone floors and skirting with grinding machine and polishing the floor include machine charges and Filing the Gaps/Grooves with pigment added White Cement complete in all respects and to the entire satisfaction of the Engineer in charge. (N.S.) |
| 35 | Retile terracing of mud phaska covered with tiles or brick, in cement mortar by reusing dismantled tile or bricks after cleaning and making tile servicalbe for reuse, dismantling mud phaska and cleaning the mother slab propoerly (75mm old earth and 25mm new earth) after performing water proofing treatment which will be paid seperately. Laying 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat brick tile, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat including replacing unserviceable tiles or bricks with new ones (the cost of the new tiles/bricks excluded) all complete as per direction of Engineer-in-Charge. (N.S.) |
| 36 | Providing and Fixing Water proofing treatment with (MAK polyplast regular grade 2104 or equivalent) 1mm thk weighing 1.75 kg/sqm over the surface with two coat of bitumen 85/25 @1.20 kg/sqm fixing polyplast over laps sealed with flame of blown bitumen including cost of sealing the overlap 10cm width complete in all respect to the entire satisfaction of Engineer-In-Charge. (N.S.) |
| 37 | Supply of 1st quality brick tiles 9\\" X 4 1/2\\" X 1 1/2\\" complete in all respects to the entire satisfaction of Engineer in charge. (N.S.) |
| 38 | P/F 110mm internal dia PVC pipe as rain water pipe on walls of 6 kg. pressure with Bend, Elbow and Clamps complete in all respect to the entire satisfaction of Engineer--in-Charge. (N.S.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender