Housing Urban and Rular Development Government Departments Closing in 12 days TDR #58432328

Tender For Camc Of Different Capacity Ups & Servo Stabilizers, Dg Sets , Substation, At Sms Hospital Jaipur

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
1.73 Crore
Estimated cost
Bid Submission
19 Nov 2026
12 days left
EMD
3.47 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Camc Of Different Capacity Ups & Servo Stabilizers, Dg Sets , Substation, At Sms Hospital Jaipur

BOQ

Name of Work:- CAMC of Different Capacity UPS & Servo Stabilizers, DG Sets , Substation, at SMS Hospital Jaipur
Sl. No. Item Description
1All in all Comprehensive annual maintenance and repair contract for On line UPS of following Capacity ( Excluding Replacement of Batteries )
2600 VA UPS
31 KVA UPS
42 KVA UPS
53 KVA UPS
65/6 KVA UPS
710 KVA UPS
830KVA UPS
9All in all comprehensive maintenance including servicing , replacement of fuel - filter, coolant , lubricating oil etc of Diesel Generating set including auto mains failure (AMF) panel , change over switch , earthing etc as per OEM guidelines and maintenance manual complete in all respet. (Excluding replacement of batteries as and when required.)
1015 KVA
1150 KVA
1262.5 KVA
1363 KVA
14125 KVA
15200 KVA
16250 KVA
17320 KVA
18380 KVA
19500 KVA
20All in all comprehensive maintenance of 11/0.415 KV or 33/0.415 KV Distribution sub station including 11 KV circuit Breaker , Transformer and its complete accessories , Auto transfer switch ,repairing of LT/HT cables with terminations, LT panel with complete accessories , Sub station Earthings etc with maintaining of Log Books complete in all respect but excluding of transformer oil as and when required.
2122780 KVAx12 month=273360 kva
22All in all comprehensive maintenance of Automatic power factor correction panel including repair / replacement of defective componenets to maintain the power factor as per Discom's permissible limit and without any penalty or surcharge.
23Up to 125 KVAR APFC Panels
24Above 125 kvar APFC Panels
25Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India
26Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field
27Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field )
28Technical Helper Having basic Knowledge of E&M Services
29Replacement of Existing Battery with 12V VRLA Lead Acid Sealed maintenance free (SMF) batteries of following capacity with Warranty of 2 years (The old battery shall be retained by contractor)
3012V 9 AH
3112V 12 AH
3212V 18 AH
3312V 26 AH
3412V 28 AH
3512V 34 AH
3612V 42 AH
3712V 150 AH
3812V 185 AH
39Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. .
40Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required.
41Replacement of existing transformer oil confirming to IS: 335 after removing of old oil and remove from site (old oil shall be retained by the contractor)
42Charges for Testing of transformer oil for its viscosity and dielectric strength including collection of sample from top and bottom of the existing transformer tank and submission of test report complete with all T & P , labour etc as required .
43Charges for Collection , Filtration and dehydration of existing transformer oil with the help of high vaccum filtration machine and cleaning of core-coil assembly by hot oil for removal of sludge / dust particles etc. as required.
44Supply and filling of fresh transformer oil as per IS: 335 in existing transformer along with submission of oil test report for its physical and chemical properties.The oil shall be clear and free from any suspended matter or sediments complete as required complete in all respect. .
45Repairing of LT/HT bushings of Distribution Transformers including replacement of brass studs , porcelain insulators , nut bolts , oil seals , gaskets etc. complete as required complete in all respect. .
46LT Bushing Set
47315 KVA
48500 KVA
49800 KVA
501000 KVA
51HT Bushing Set
5263 KVA to 500 KVA
53630 KVA to 1600 KVA
54Replacement of Silica gel Breather of Distribution Transformers of following capacities complete in all respect. .
55250 KVA
56315 KVA
57500 KVA
58630 KVA
59800 KVA
601000 KVA
611250 KVA
62Replacement of gasket of Distribution Transformers of following capacities complete in all respect.
6363 KVA to 500 KVA
64630 KVA to 1600 KVA
65Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
66Three phase Ammeter with Inbuilt Selector Switch
67Three phase Voltmeter with Inbuilt Selector Switch
68Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required .
69Ring type tape wound CT
70C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA
71C T Class 1, Ratio 1500/5 to 3000/5, Burden 15 VA
72Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required.
73Red/yellow/Green colour
74Blue / white Colour
75Providing & Fixing of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required.
7611 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)
77Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required.
78Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)
79Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
8012.5 KVAR
8115.0 KVAR
8220.0 KVAR
8350.0 KVAR
84SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
853 pole MCCB With Thermal Magnetic release
86250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
87400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
88630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
894 pole MCCB With Thermal Magnetic release
90250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
91400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
92Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect.
93Direct Rotary Handle
94Spreaders for 400A, 4Pole MCCB
95Spreaders for 630A, 4Pole MCCB
96Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.
973.5 x 95.0 sq.mm
983.5 x 120.0 sq.mm
993.5 x 150.0 sq.mm
1003.5 x 185.0 sq.mm
1013.5 x 240.0 sq.mm
1023.5 x 300.0 sq.mm
1033.5 x 400.0 sq.mm
1043.5 x 630.0 sq.mm
105Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
10635.0 Sq.mm
10750.0 Sq.mm
10870.0 Sq.mm
10995.0 Sq.mm
110120.0 Sq.mm
111150.0 Sq.mm
112185.0 Sq.mm
113240.0 Sq.mm
114300.0 Sq.mm
115400.0 Sq.mm
116630.0 Sq.mm
117All in all Comprehensive annual maintenance and repair contract for On line UPS of following Capacity ( Excluding Replacement of Batteries )
11860KVA Online UPS
119All in All annual maintenance contract for Servo Stablizers installed in various places at SMS Hospital of the following capacity complete in all respect etc as reqd.
1205 KVA
12110 KVA
12215 KVA
12330 KVA
124Add: GST@18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58432328
AUTHORITY Government Departments
TENDER VALUE 1.73 Crore
LAST DATE 19-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Camc Of Different Capacity Ups & Servo Stabilizers, Dg Sets , Substation, At Sms Hospital Jaipur
Basic Detail
Tender No EE_PWD_Medical_NIT_29_2026_27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 06 Nov 2026
Submission Date 19 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 1.73 Crore
Tender Fee 2000
EMD 3.47 Lakhs
Exemption Available
Document List
80be2cfa-746f-48b2-88ca-be64b39c501b.html
AMCandoperationofElectric_1.pdf
BOQ_1073934.xls
Cover3.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

80be2cfa-746f-48b2-88ca-be64b39c501b.html

pdf

AMCandoperationofElectric_1.pdf

xls

BOQ_1073934.xls

pdf

Cover3.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender