Tender For Camc Work Of Fire Fighting, Fire Detection System, Monoblock Motors, Over Head Tank Motor & Submersible Borewell At Sms Hospital Jaipur

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
1.28 Crore
Estimated cost
Bid Submission
19 Nov 2026
12 days left
EMD
2.56 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Camc Work Of Fire Fighting, Fire Detection System, Monoblock Motors, Over Head Tank Motor & Submersible Borewell At Sms Hospital Jaipur

BOQ

Name of Work:- CAMC work of Fire Fighting, Fire Detection System, Monoblock Motors, over head tank motor & submersible borewell at SMS Hospital Jaipur
Sl. No. Item Description
1All in all comprehensive maintenance of fire protection system including jockey Pump , main motor pump , terrace pump , Diesel pump , water sprinkles pipe lines ,wet /dry risers , various type of valves , over head / under ground water tanks , First aid hose reels , Indoor / out door hydrants , air vessels , hose pipes , branch pipes , hose cabinets , control panel , all type of fire extinguishers , battery charger ,wiring/cabling etc. complete in all respect. and standard terms & conditions of PWD (including replacement of battery and refilling of fire extinguishers .)
22280 /2250 LPM, 70 Mtr Head main pump fire station
32850 LPM, 70 Mtr Head main pump fire station
4All in all comprehensive maintenance of fire detection control system, manual call point , response indicators , speakers/hooters . PA system , wiring/cabling etc complete in all respect as per OEM's recommendations / guidelines and standard terms & conditions of PWD guide lines to put the system healthy and functional .
5Addressable type FACP with repeater panel, all types of detectors & devices (total 125 Nos) , fault isolation module ,
6Conventional type FACP with detectors & devices
7All in all comprehensive maintenance of mono block / submersible motor pump set with starter panel etc. complete in all respect
8Mono block Motor pump set
9Sub mersible Motor pump set
10Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect.
11Delowering and Lowering
12Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1310.0 H.P.
14Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
15From 7. 5 HP to 10.0 HP
16Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
17From7. 5 HP to 10.0 HP
18Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India
19Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field
20Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field )
21Technical Helper Having basic Knowledge of E&M Services
22Replacement of Existing Battery with 12V VRLA Lead Acid Sealed maintenance free (SMF) batteries of following capacity with Warranty of 2 years (The old battery shall be retained by contractor)
2312V 12 AH
2412V 18 AH
25SITC of pressure switches of pressure range 3 to 15 Bar for Main, Jockey, Terrace pump and Diesel pumps, Etc. as Required ( Control Cable from Pressure switch to Panel to be Paid Extra ).
26Providing and fixing 20/25 mm dia. (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve confirming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) complete with 1 no. Matching Flanges (Minimum 10 mm thick), nuts, bolts, washers, gaskets etc as required.
27Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required.
2825 mm dia.
29Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick walls and making good the same. complete with painting of one coat of Red Oxide and two or more coat of synthetic enamel paint of Signal red shade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.).
3025 mm dia
3150 mm dia
3280 mm dia
33100 mm dia
34150 mm dia
35200 mm dia, 6.0 mm thick
36Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holes in existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets etc as required of following sizes.
37200 mm dia
38Supplying and Fixing of PN 16 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes.
39100 mm dia
40150 mm dia
41200 mm dia Gear Operated
42Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A) 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304 male and female couplings (IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.
43Supplying & fixing SS-304 Short Branch Pipe conforming to IS: 903:93 fitted with 20mm (nominal internal diameter) bore nozzle, for projecting water in form of solid jet. The Branch pipe shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes.
44Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required. (A) Rubber Hose (B)20 mm dia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall. (D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1 through Forged steel Screwed Union & M.S. pipe. Etc. as required.
45With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969 and Bursting pressure min. 42 Kg/sqcm
46Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valve complete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Ways.
473 Way
484 Way
49Providing and fixing of 150 mm Dia. Flanged Gun Metal Fire brigade Suction hose coupling (draw out connection) for female coupling as per IS:902-1974 complete with Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required.
50Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.2 mm thick MS sheet duly powder coated in red color externally and white internally with 6 mm thick glazed doors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra)
51Providing and fixing of Fire / Electrical Shaft Door made from powder coated (50 Micron) aluminium partialy glazed with 6 mm thick glass and Partialy / Fully Louvered with Outer frame of Aluminium Section of Size 100 mm x 45 mm x 1.5 mm and Shutter's Top, Middle & side Section of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mm Complete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge.
52Providing and Fixing of 15 mm dia Bronze quartzoid bulb type sprinkler heads with Maximum working pressure 11.6 Kg / Sqcm and suitable for 68 degree centigrade rating standard response (UL Listed) chrome plated complete in all respect of the following type.
53Pendant/ Upright type
54Providing & fixing Stainless Steel pressure gauge with dial of 150 mm dia size and range 0 to 20 kg/sq.cm with 3 / 8 \\" BSP bottom entry , Ball valve , SS Syphon tube all fittings etc, duly calibrated before installation in MKS and FPS units, Accuracy Level +/- 1% including Making Drilling in Existing MS Pipe Etc. as required.
55Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required.
561.0 Sq. mm
57Add: GST@18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58432325
AUTHORITY Government Departments
TENDER VALUE 1.28 Crore
LAST DATE 19-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Camc Work Of Fire Fighting, Fire Detection System, Monoblock Motors, Over Head Tank Motor & Submersible Borewell At Sms Hospital Jaipur
Basic Detail
Tender No EE_PWD_Medical_NIT_29_2026_27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 06 Nov 2026
Submission Date 19 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 1.28 Crore
Tender Fee 2000
EMD 2.56 Lakhs
Exemption Available
Document List
5de8c32f-5fd9-4e72-9df8-71c9c55977a6.html
AMCandoperationofFireDetection.pdf
BOQ_1073933.xls
Cover2.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

5de8c32f-5fd9-4e72-9df8-71c9c55977a6.html

pdf

AMCandoperationofFireDetection.pdf

xls

BOQ_1073933.xls

pdf

Cover2.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender