Tender For Construction Of 300 Sqm Capacity Naturally Ventilated Polyhouse At Coconut Farm Chitrakut, Rangat.
Tender Value
15.52 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
12 days left
EMD
31045
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 300 Sqm Capacity Naturally Ventilated Polyhouse At Coconut Farm Chitrakut, Rangat.
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 2 | All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | All kinds of soil. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 1:2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 9 | Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Well steining |
| 11 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 12 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 13 | On steel work |
| 14 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 15 | 110 mm diameter |
| 16 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 17 | Coupler110 mm |
| 18 | Single tee with door110x110x110 mm |
| 19 | Bend 87.5°110 mm bend |
| 20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 21 | 25 mm nominal dia Pipes |
| 22 | 40 mm nominal dia Pipes |
| 23 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 24 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 25 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 26 | All kinds of soil |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 28 | Ordinary rock |
| 29 | Extra for every additional lif of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 30 | All kinds of soil |
| 31 | Ordinary or hard rock |
| 32 | Reinforced cement concrete work in well-steining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3(1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 33 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 34 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 35 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 36 | 12 mm cement plaster of mix: |
| 37 | 1:4(1 cement: 4 fine sand) |
| 38 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 39 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 40 | Two or more coats on new work |
| 41 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 42 | Providing and fixing UPVC pipe clips of approved design to UPVC pipes with screws of required length etc. complete as per the direction of Engineer-in-charge. |
| 43 | 110 mm |
| 44 | Providing and fixing UPVC Gutter (160 mm x160 mm ) including all necessary accessories as per the direction of the Engineer-in-charge all complete. |
| 45 | Providing and fixing CPVC ball valve of approved quality |
| 46 | 25 mm nominal bore |
| 47 | 40 mm nominal bore |
| 48 | Providing and fixing CPVC union socket of approved quality |
| 49 | 25 mm nominal bore |
| 50 | 40 mm nominal bore |
| 51 | Providing and fixing 200 GSM anti fungal UV treated poly film approved quality and make, and fixing it on the roof as per the requirement. |
| 52 | Providing and fixing of UV treated 40 mesh insect proof nylon net of approved quility and make, and fixing it on all side of the poly house as per direction of Engineer-in-charge. |
| 53 | Supplying and fixing 100 GSM wooven fabric weedmat black in colour as per direction of Engineer-in-charge. |
| 54 | Providing and fixing of UV treated 80 GSM 50 % green shade net all over the structure including all labour charges etc complete as per direction of Engineer-in-charge. |
| 55 | Supplying and fixing aluminium channel with zig zag opening including all labour charges etc complete for tightening the UV film, shade net in insect net etc complete as per direction of engineer-in-charge. |
| 56 | Providing and installation of 16 mm LDPE lateral pipe with all fittings and accessories for fixing mist spinkler. |
| 57 | Supplying and installation of 26 LPH jain butterfly mist sprinkler etc complete as per direction of Engineer-in-charge. |
| 58 | Supplying and installation of 25 cum sand filter etc complete as per direction of engineer-in-charge. |
| 59 | Supplying and installation of 12 cum screen filter etc complete as per direction of engineer-in-charge. |
| 60 | Supplying and installation of Digital Watering Timer for fixing times for sprinkler water at site etc complete as per direction of engineer-in-charge. |
| 61 | Supplying, installation, testing and commissioning of single phase, 1.0 HP, 220 Volts, Electric Self-priming Pump make - Kirloskar/Havells/Bajaj/Crompton or its equivalent ISI mark with hose pipe, foot valve etc all accessories i/c connection etc as required as per the direction of Egineer-in-charge. |
| 62 | Supplying and filling of materials in ring well side to be used as filter media as per the direction of EIC. |
| 63 | Stone boulder Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender