Tender For Supply Installation Testing and Commissioning of 1 No 8 Passenger Mrl Type Lift In Replacement Of Life Expired And Faulty Lift At Vengi Telephone Bhavan, Eluru . Sh: Supplying & Laying Of Power Cable, Lift Well Illumination, Earthing And A
Tender Overview
Project Description
Tender for Supply Installation Testing and Commissioning of 1 No 8 Passenger Mrl Type Lift In Replacement Of Life Expired And Faulty Lift At Vengi Telephone Bhavan, Eluru . Sh: Supplying & Laying Of Power Cable, Lift Well Illumination, Earthing And Associated Works.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer (Electrical) , BSNL Electrical Division, Vijayawada Name of Work: SITC of 1 no 8 passenger MRL type lift in replacement of life expired and faulty lift at Vengi Telephone Bhavan, Eluru . SH: Supplying & laying of power cable, lift well illumination, Earthing and Associated works. NIT No: 79/BSNL/EDV/2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER HSN Code TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. DESCRIPTION OF ITEM Item Code / Make Qty Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic unit price exclusive of all taxes & Charges FF Packing % FF Packing Amount CGST % CGST Amount SGST% SGST Amount IGST % IGST Amount All-inclusive Unit Cost (5+7)+[(9+11) or 13] Total price inclusive of all charges (3 x 14) Amount of Input tax Credit (ITC) to be availed [(9+11) or 13] Total Amount of Input tax Credit (ITC) to be availed (3 x 16) Unit price excluding ITC amount (net unit cost) (14-16) Total price inclusive of all levies and charges but excluding ITC (net total cost) HSN for goods and SAC for services Total price inclusive of all levies and charges but excluding ITC (net total cost) TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | SH-I Power cable, EI & Fans : Supplying & Laying of 4 core 16 sq.mm PVC insulated 1.1KV grade Aluminium power cable in the fallowing ways from LT Panel to Main switch at 3rd Floor Meter/ Meter to BTS equipment as required. a)In existing PVC /surface/in open (4x16 sqmm) |
| 3 | Supplying and fixing of FN-32 TPN Switch Disconnector Fuse Unit With SS Enclosure and 3nos.HRC fuses, including interconnections, testing etc., as required.(Make: LK (L&T) (SK90483) or equivalent) |
| 4 | Supplying and fixing following way, single pole and netural, sheet steel, MCB distribution board, 240v, on surface / recess, complete with tinned copper bus bar, netural bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator) (i)8 way, double door |
| 5 | S/F of the following MCBs suitable for operation on 230V, AC supply in existing syntex box as required. (i)32A 4P MCB |
| 6 | (ii)10A SP MCB |
| 7 | (iii)20A DP MCB |
| 8 | Supplying and making end termination with brasscompression gland and aluminium lugs for 4x16Sq.mm (28mm) size of PVC insulated and PVC sheathed/XLPEaluminium conductor cable of 1.1 KV grade asrequired. |
| 9 | S/L of 10 sqmm PVC insulated single core copper power cable for interconnections between Main switch and DB, including interconnections and testing complete as reqd. |
| 10 | S/F of bulkhead fitting along with 11 W LED lamp suitable for operation on 230V, 50Hz AC supply, including inter connections etc as required. |
| 11 | Wiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit etc as required. (i)2X2.5 sq.mm + 1x2.5 sq mm earth wire |
| 12 | Supplying and fixing of suitable size PVC modular box along with modular cover plate with 1no 6A socket and 2nos 6A rating switches including interconnections etc.. Complete as required. |
| 13 | SH-II Earthing: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc. without charcoal/ coke and salt as required. |
| 14 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 15 | Providing and fixing earth bus of size 32 mm x 6 mm GI strip of 30 cm long on surface etc., complete as required. |
| 16 | Providing and fixing of 8gauge copper wire on surface of wall in lift well for extending earth from earth bus bar to lift control panel board and body earth, complete etc. as required. |
| 17 | SH-III Associated works: Supplying & Fixing of 8Ft. length 200mmx100mm heavy gauge MS I-channel inside the lift well (between two opposite walls of lift well) at top of the lift with the support of 2nos 12mm thick MS flange (made with 12mm MS plate) duly fixed to the wall with suitable size bolts and nuts , welding the I-channel to the MS flange, providing U type hook made with 20mm dia MS rod , including transportation, loading and unloading, fabrication & labour charges and hiring charges of welding machine etc., complete as required. |
| 18 | Arranging groove cutting of brick wall for accommodating lift control panel including finishing the surface with cement mortar etc. complete as required |
| 19 | Arranging cutting of 9\\" brick wall of size 2Ft.x2Ft. For fresh air opening purpose, including finishing all sides after cutting with cement mortar etc., complete as required.( smoke vent) |
| 20 | Supplying of floor indication boards made of 3 mm thick acrylic sheet (with radium stickers), affixing all boards on surface of wall at all floor levels on opposite wall of lift door etc. complete as required. |
| 21 | Arranging statutory inspection of the lift by AP state government approved lift inspector ( Competent person under AP Factories Rules) for testing of fitness of the lift including all payable fees to the inspector etc. complete as required. |
| 22 | Supplying and fixing of air ventilator frame for the lift well made up of fabricated aluminium of size 15''x15'' with provision of 3 nos. glass louvers and PVC insect preventing net including fixing in existing opening of wall, making finish around the frame after fixing , including all labour charges etc. complete as required. |
| 23 | Supplying and laying of PVC floor mat (4 mm thick , suitable for indoor use ) inside the lift cabin and at each lift entrance (G+4) including all charges like transportation, cutting of mat to required size etc. complete as required.(30 Sq.ft approximately). |
| 24 | Removal of existing angle iron brackets of old lift installation fixed to the walls of the lift well, including chipping of masonry around the brackets and filling and closing the holes formed after removal with cement concrete, making good the affected surfaces, complete as required. |
| 25 | Removal of existing wooden door frames and other associated wooden works at all four lift landing entrances, including chipping of the 9-inch-thick brick masonry walls and lintels above and around the lift door openings, wherever necessary, to facilitate proper alignment and installation of lift doors at all floor levels, and making good the affected masonry surfaces with cement mortar after fixing of the lift doors, including all necessary connected civil, repair and finishing works, removal of debris, and all incidental works required to complete the job in all respects, as directed by the Engineer-in-Charge. |
| 26 | Closing the openings in the existing lift machine room by providing M.S. chequered plate of size 1.00 Mtr X 1.40 Mtr size, including cement concrete around the chequered plates, complete as required. |
| 27 | Removal of the spring buffers and chipping the pedestals of old dismantled lift in the lift pit of the old lift installation etc as reqd. |
| 28 | Chipping of the wall in the lift well at 1st and 2d Floor level, painting the rusted reinforcement steel rods with 2 coats of rust proof paint , and plastering the wall , making the lift pit waterproof etc., as reqd. |
| 29 | Providing one coat of white wash with emulsion paint(ordinary grade) to four sides of the lift well, using safety belts etc. complete as required.( 20 mtr X 8 mtr - 160 Sq.meter ) (approx.). |
| 30 | Supplying and fixing of 18 mm thick granite stone of approved colour and design around the lift door frames on existing masonry brick walls for all four floors of the building with cement mortar and cement slurry, grinding of ends wherever required including filling the gaps between stone pieces with grouting material etc. complete as required.Note: 4.65 Sq.mtr(approx.) area for each floor level, total 18.60 Sq.mt(Approximately) for (G+3) floors ( for Architrave work). Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select, Excess (+), Less (-) 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender