Housing Urban and Rular Development Government Departments Closing in 18 days TDR #58431596

Tender For Electrification Work Of Market Complex At Kurshar Hat Bazar Under Sukarurkuthi Gp Within Dinhata-Ii Block In The District Of Coochbehar. (Deep Tube Well Included).

Issued by Government Departments · Jalpaiguri, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Nov 2026
18 days left
EMD
40000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrification Work Of Market Complex At Kurshar Hat Bazar Under Sukarurkuthi Gp Within Dinhata-Ii Block In The District Of Coochbehar. (Deep Tube Well Included).

BOQ

Name of Work:- Electrification work of Market complex at Kurshar Hat Bazar under Sukarurkuthi GP within Dinhata-II Block in the district of Coochbehar. (Deep Tube well included).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group C
2Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired. 5/6 A switch
33 pin 5/6 A socket outlet
4Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modularsocket outlet and 5/6 A modular switch, connectionsetc. as required.
5Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch,connections etc. as required.
6Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
72 X 4 sq. mm + 1 X 4 sq. mm earth wire
82 X 10 sq. mm + 1 X 6 sq. mm earth wire
94 X 10 sq. mm + 2 X 6 sq. mm earth wire
10Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distributionboard of sheet steel, dust protected, duly powderpainted, inclusive of 200 A tinned copper bus bar,common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.)4 way (4 + 12), Double door
11Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. 100A
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required. Triple pole
13Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distributionboard, 415 V, on surface/ recess, complete withtinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted includingearthing etc. as required. (But withoutMCB/RCCB/Isolator)6 way (4 + 18), Double door .
14Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
15Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required. 32 Amp. DP MCB.
16(6-32)Amp. SP MCB.
17Laying and fixing of one number PVC insulated andPVC sheathed / XLPE power cable of 1.1 KV grade offollowing size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
18Supplying and making end termination with brasscompression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade asrequired.i) 4 core X 25 sq.mm.
19ii) 2 core x10 Sqmm.
20Supplying and fixing of light class G.I. pipe of 50 mmdia. (nominal) 3 metres length along the pole forprotection of under ground cable as required.
21Installation, Testing and Commissioning of exhaustfan in the existing opening, including making good thedamage, connection, testing, commissioning etc. asrequired. Upto 450 mm sweep
22Extra for fixing the louvers/ shutters complete withframe for a exhaust fan of all sizes
23Brush Less Direct Current (BLDC) Fan without Remote :Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) Make:Usha/Orient Electric/Crompton/Havells
24Installation, Testing and Commissioning of ceiling fan,including wiring the down rods of standard length(upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVCinsulated, copper conductor, single core cable etc. asrequired.
25Supplying and fixing extra conduit down rod of 20 cmlength G.I. pipe 15 mm dia, heavy gauge includingpainting etc. as required. (Note : More than 5 cmlength shall be rounded to the nearest 10 cm and 5cm or less shall be ignored)
26Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plateswitch box including connections but excludingmodular plate etc. as required.
27LED Batten light (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning ofLED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm)18- 22 Watt ( Make Halonix/Philips/Bajaj/Crompton/Halonix/Havells/Jaguar)
28Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting ofall types, complete with all accessories and tube/lampetc. directly on ceiling/ wall, including connectionswith 1.5 sq. mm FRLS/HFFR PVC insulated, copperconductor, single core cable and earthing etc. asrequired.
29LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housingComplete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 18 watt Make:(Phillips/Bajaj/Crompton)
30Supplying and fixing brass batten/ angle holderincluding connection etc. as required.
31Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories, and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required.
32Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, includingconnection/ terminating with G.I. nut, bolt, spring,washer etc. as required. (Jointing shall be done byoverlapping and with 2 sets of G.I. nut bolt & springwasher spaced at 50mm)
33Supplying and fixing of 32 mm dia X 2.00 metres longG.I. pipe (medium class) bracket for mounting offluorescent / HPMV / HPSV street light fitting on poleincluding bending the pipe to the required shape, 2nos 40 mm X 3 mm flat iron clamps with nuts, boltsand washer, painting the flat iron with primer and finishpaint etc. as required.
34LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). 120 watt Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external Connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make Havells/Halonix/Jaguar/Philips/Crompton)
35Supplying, Installation, Testing and Commissioning of ISI Marked openwell submersible pump set contain with stainless steel shaft and cast iron/SS body, the pump shall be designed to prevent over loading and having dynamically balanced rotating parts etc. thepump capable of delivering following capacities discharge at suitable head and lowering the pumps in water bodies and suitable for operation on 415V(+- 10%), 3-phase AC supply including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet including connection, interconnection ,supports etc. as required. suitable for 900LPM at 25 Mtrs Head etc. complete as required.
36Supplying & fixing PVC insulated PVC sheathedcopper conductor submersible flat cable ISI Marked inexisting metal/ HDPE / PVC/ pipe/ in bore well/ insump including fixing the cable to GI/HDPE pipe withsuitable cable tags of following sizes etc. complete asrequired. 3 Core 2.5 Sq mm Flat Cable
37Supplying & Fixing iron beam fan clamp of two piece type, as perapproved specification, fabricated from 40 mm x 9 mm MS sheetflat suitable for beam having flange upto 150 mm wide – (As perDrawing no. 476 of PWD Specification Book – May 1991)
38Supply, fabrication, installation, testing and Commissioning of 14 SWG MS sheet metal box to made of 40 mm x 40 mm x 5 mm MS angle and 40 mmx 5 mm MS flat accommodate WBSEDCL energy meter & others & others Department in suitable size double door cover welded on MS flat iron frame with wire mesh door arrangement to facilate meter reading with locking arrangement. ( for individual metering for shops).Fixed on wall on wooden base and angle iron frame including grouting, cementing, mending good to original finish, painting etc complete with internal electrical connection by suitable copper conductor, proper termination & socketing as per the requirement and as per the direction of Engineer-in-Charge.i) 32 A DP Main Switch- 15 nos.ii) Busbar chamber of 415 V,200 A, Al Bars of 85mm long of size 4 x 25 x 5mm in 500x150mm sheet metal Box.- 1 no.
39Supplying and fixing 415V, 125A TPN SFU with sheetsteel enclosure on flat iron/angle iron frame on wallwith nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse on flat iron frame.
40Supply & Fixing 32A 250 V DP with fuse on L&N Iron clad Main Switch on Iron legs on wall as per instruction of EIC.
41Supplying and fixing 4 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as per instruction of EIC.
42Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class ofinsulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
43Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection. 63 A FP MCB
44Supply 1.1 KV grade PVC Armoured XLPE insulated AL conductor cable .i) 4 core X 25 sq.mm.
45ii) 2 core x10 Sqmm
46Supplying & Fixing GI waterproof type looping cable box size200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, onecompression type brass cable gland for upto 2- core 16 sqmmPVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
47Fixing only bulk head /ceiling fitting on wall /ceiling by screws etc.
48Sinking of Deep Tube well: Labour for boring through any type of soil for sinking tube well ofrequired dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia. First 50 metre).
49Next 50 metre
50Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(ii) 80 mm dia. (internal)
51(i)150 mm dia. (internal)
52Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. 80 mm dia.
53Labour for jointing and lowering pipes including strainer within the tube well bore vertically with necessary sockets, special fittings and welding as required including cost of all jointing materials, hire charges of tools and plants, cutting pipes to required sizes, making threads, welding pieces together etc. as necessary as per direction of the Engineer-in-charge.Upto 100 mm dia. pipe
54(ii) Above 100 mm dia. and upto 200 mm dia. pipe
55Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
56Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
57Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
58Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
59Supply, fitting, fixing and lowering the following with fabrication as required:(a)80 mm dia bottom cap.
60(b) 150 X 80
61©150 mm dia M.S. Top cap with hole.
62(d) 150 mm dia M.S. Ring.
63(e) 100 mm dia MS Ring.
64(f) 80 mm dia Centre Guide.
65(g) Threaded Adopter( 80 mm Dia).
66(H) Threaded Adopter( 150 mm Dia).
67Supplying & fixing medium gauge 50 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
68Supply, fitting, fixing 50 mm dia G.I. Pipe (ISI-M) column pipe for submersible pump lowering having 3-mtr average length including special threading in Lathe and S & F one GI socket.
69S & F suitable size of M.S. Flat clamp for holding the column pipe, pump motor in the tube well with necessary nuts, bolts, washer as per direction of EIC.
70Supplying, fitting and fixing G.I. cap at top suitable for tube well.
71S & F of G.I. Accessories ISI approved with all jointing materials:a) 50 mm dia Bend
72b) 50 mm dia Elbow.
73c) 50 mm dia Nipple.
74d) 50 mm dia Union.
75e) 50 mm dia Socket. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58431596
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 25-11-2026
Authority
Authority Name North Bengal Development Department
Work Description Tender for Electrification Work Of Market Complex At Kurshar Hat Bazar Under Sukarurkuthi Gp Within Dinhata-Ii Block In The District Of Coochbehar. (Deep Tube Well Included).
Basic Detail
Tender No NBDD/BS/EE /NIQ-41 - (EL) of 2026-2027
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 06 Nov 2026
Submission Date 25 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 40000
Exemption Available
Document List
BOQ_2567841.xls
fe60e6b4-cf15-4b4d-8c72-9616ce45e0a8.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2567841.xls

html

fe60e6b4-cf15-4b4d-8c72-9616ce45e0a8.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf