Project Description

Tender for Electrification Work Of Class Room With Toilet Block, Cycle Stand & Pathway At Nigamananda Siksha Niketan Girls High School Under Village-Ii Gram Panchyat At Dinhata -Ii Block In The District Of Coochbehar (Deep Tube Well Included)

BOQ

Name of Work:- Electrification work of class room with Toilet Block, Cycle stand & Pathway at Nigamananda Siksha Niketan Girls high school under village-II Gram panchyat at Dinhata -II block in the District of Coochbehar (Deep Tube well included)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable ( Make Havells/Polycab/RR Cabel/Standard) in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group C
2Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired. ( Make Legrand/Schneider/Siemens/Havells Crabtree)5/6 A switch
33 pin 5/6 A socket outlet
4Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modularsocket outlet and 5/6 A modular switch ( Make Legrand/Schneider/Siemens/Havells Crabtree), connectionsetc. as required.
5Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch ( Make Legrand/Schneider/Siemens/Havells Crabtree),connections etc. as required.
6Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor ( Make Havells/ Polycab/RR cabel/Standard), single core cable in surface/recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
72 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
82 X 10 sq. mm + 1 X 6 sq. mm earth wire
9Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. ( Make Legrand/Schneider/Siemens/Havells Crabtree) (But without MCB/RCCB/Isolator)12 way , Double door
10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required. ( Make Legrand/Schneider/Siemens) 32 Amp. DP MCB.
11(6-32)Amp. SP MCB.( Make Legrand/Schneider/Siemens)
12Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distributionboard, 415 V, on surface/ recess, complete withtinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted includingearthing etc. as required. (But withoutMCB/RCCB/Isolator) ( Make Legrand/Schneider/Siemens/Havells Crabtree)6 way (4 + 18), Double door .
13Supplying and fixing following rating, four pole, 415 V,isolator in the existing MCB DB complete withconnections, testing and commissioning etc. asrequired. 63 A ( Make Legrand/Schneider/Siemens)
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required.
15Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distributionboard of sheet steel, dust protected, duly powderpainted, inclusive of 200 A tinned copper bus bar,common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.)( Make Legrand/Schneider/Siemens/Havells Crabtree)4 way (4 + 12), Double door
16Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required.
17Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required. Triple pole ( Make Legrand/Schneider/Siemens/Havells Crabtree)
18Single pole ( Make Legrand/Schneider/Siemens)
19Supply 1.1 KV grade PVC Armoured XLPE insulated AL conductor cable .( Make Havells/ Polycab/RR Cabel/Havells Crabtree)i) 3.5 core X 25 sq.mm.
20ii) 2 core x10 Sqmm
21Laying and fixing of one number PVC insulated andPVC sheathed / XLPE power cable of 1.1 KV grade offollowing size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
22Supplying and making end termination with brasscompression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade asrequired.i) 3.5 core X 25 sq.mm.
23ii) 2 core x10 Sqmm.
24Supplying and making outdoor end termination withcast resin compound including aluminium lugs andother jointing materials for following size of PVCinsulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required. i) 3.5 core X 25 sq.mm.
25Supplying and fixing of light class G.I. pipe of 50 mmdia. (nominal) 3 metres length along the pole forprotection of under ground cable as required.
26Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class ofinsulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. ( Make Usha/ Orient Electric/Crompton/Havells)
27Installation, Testing and Commissioning of exhaustfan in the existing opening, including making good thedamage, connection, testing, commissioning etc. asrequired. Upto 450 mm sweep
28Extra for fixing the louvers/ shutters complete withframe for a exhaust fan of all sizes
29Brush Less Direct Current (BLDC) Fan without Remote :Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor ( Make Usha/ Orient Electric/Crompton), class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
30Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
31Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plateswitch box including connections but excludingmodular plate etc. as required.
32Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan ( Make Usha/ Orient Electric/Crompton) and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external Connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
33Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts &washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20PVC insulated flexible copper wire 0.5 mt. length
34LED Batten light (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light ( Make Halonix/Philips/Jaguar/Crompton/Havells) of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Submission of test report and warranty certificate from OEM for atleast five years is mandatory.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm)18- 22 Watt
35Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting ofall types, complete with all accessories and tube/lampetc., including supplying and fixing ball and socketarrangement, 2 Nos. down rods of 20 mm dia X 1.6mm thick steel conduit upto 30 cm length, paintingand wiring the down rods and connections with 1.5sq. mm FRLS/HFFR PVC insulated, copperconductor, single core cable and earthing etc. asrequired.
36LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) Make Halonix/Philips/Crompton/Wipro as per the discretion of ythe EIC) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housingComplete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 18 watt Make Halonix/Philips/Jaguar/Crompton/Havells)
37Supplying and fixing brass batten/ angle holderincluding connection etc. as required.
38Fixing only bulk head /ceiling fitting on wall /ceiling by screws etc.
39Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories, and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required.
40Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, includingconnection/ terminating with G.I. nut, bolt, spring,washer etc. as required. (Jointing shall be done byoverlapping and with 2 sets of G.I. nut bolt & springwasher spaced at 50mm)
41Supplying and fixing of 32 mm dia X 2.00 metres longG.I. pipe (medium class) bracket for mounting offluorescent / HPMV / HPSV street light fitting on poleincluding bending the pipe to the required shape, 2nos 40 mm X 3 mm flat iron clamps with nuts, boltsand washer, painting the flat iron with primer and finishpaint etc. as required.
42Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
43LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). 120 watt ( Model HLSLD-E1-120-CWDL-R01 Make Halonix or equivalent model Philips/Jaguar/Crompton/Havells) ) Submission of test report and warranty certificate from OEM for atleast five years is mandatorySupplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external Connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
44Sinking of Deep Tube well: Labour for boring through any type of soil for sinking tube well ofrequired dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia. First 50 metre).
45Next 50 metre
46Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(ii) 80 mm dia. (internal)
47(i)150 mm dia. (internal)
48Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. 80 mm dia.
49Labour for jointing and lowering pipes including strainer within the tube well bore vertically with necessary sockets, special fittings and welding as required including cost of all jointing materials, hire charges of tools and plants, cutting pipes to required sizes, making threads, welding pieces together etc. as necessary as per direction of the Engineer-in-charge.Upto 100 mm dia. pipe
50(ii) Above 100 mm dia. and upto 200 mm dia. pipe
51Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
52Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
53Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
54Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
55Supply, fitting, fixing and lowering the following with fabrication as required:(a)80 mm dia bottom cap.
56(b) 150 X 80
57©150 mm dia M.S. Top cap with hole.
58(d) 150 mm dia M.S. Ring.
59(e) 100 mm dia MS Ring.
60(f) 80 mm dia Centre Guide.
61(g) Threaded Adopter( 80 mm Dia).
62(H) Threaded Adopter( 150 mm Dia).
63Supplying & fixing medium gauge 50 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
64Supply, fitting, fixing 50 mm dia G.I. Pipe (ISI-M) column pipe for submersible pump lowering having 3-mtr average length including special threading in Lathe and S & F one GI socket.
65S & F suitable size of M.S. Flat clamp for holding the column pipe, pump motor in the tube well with necessary nuts, bolts, washer as per direction of EIC.
66Supplying, fitting and fixing G.I. cap at top suitable for tube well.
67S & F of G.I. Accessories ISI approved with all jointing materials:a) 50 mm dia Bend
68b) 50 mm dia Elbow.
69c) 50 mm dia Nipple.
70d) 50 mm dia Union.
71e) 50 mm dia Socket.
72Supplying, Installation, Testing and Commissioning of ISI Marked openwell submersible pump set contain with stainless steel shaft and cast iron/SS body, the pump shall be designed to prevent over loading and having dynamically balanced rotating parts etc. thepump capable of delivering following capacities discharge at suitable head and lowering the pumps in water bodies and suitable for operation on 415V(+- 10%), 3-phase AC supply including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet including connection, interconnection ,supports etc. as required. suitable for 900LPM at 25 Mtrs Head etc. complete as required. ( Make KSB/ V Guard/ Crompton/Bajaj) Submission of test report and warranty certificate from OEM for atleast five years is mandatory
73Supplying & fixing PVC insulated PVC sheathedcopper conductor submersible flat cable ISI Marked inexisting metal/ HDPE / PVC/ pipe/ in bore well/ insump including fixing the cable to GI/HDPE pipe withsuitable cable tags of following sizes etc. complete asrequired. 3 Core 2.5 Sq mm Flat Cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58431592
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 25-11-2026
Authority
Authority Name North Bengal Development Department
Work Description Tender for Electrification Work Of Class Room With Toilet Block, Cycle Stand & Pathway At Nigamananda Siksha Niketan Girls High School Under Village-Ii Gram Panchyat At Dinhata -Ii Block In The District Of Coochbehar (Deep Tube Well Included)
Basic Detail
Tender No NBDD/BS/EE /NIQ-41 - (EL) of 2026-2027
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 06 Nov 2026
Submission Date 25 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 20000
Exemption Available
Document List
BOQ_2567843.xls
f72851f3-5bb9-49fa-aa90-0a5d97aaefd8.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2567843.xls

html

f72851f3-5bb9-49fa-aa90-0a5d97aaefd8.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender