Educational and Research Institute Boards / Undertakings / PSU Closing in 12 days TDR #58431483

Tender For Underground Cabling Work In Place Of Overhead Electric Line Including Street Lights From Mmv Crossing To Law College Crossing, From Chittupur Gate To Near Non-Teaching Club (Partly) Including Arbindo Colony, Part Of Kabir Colony & From Mai

Issued by Boards / Undertakings / PSU · Varanasi, Uttar Pradesh
Tender Value
1.93 Crore
Estimated cost
Bid Submission
19 Nov 2026
12 days left
EMD
3.87 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Underground Cabling Work In Place Of Overhead Electric Line Including Street Lights From Mmv Crossing To Law College Crossing, From Chittupur Gate To Near Non-Teaching Club (Partly) Including Arbindo Colony, Part Of Kabir Colony & From Maitry Jalpan Grih Crossing To Akela Bir Baba Mandir Crossing, Bhu.

BOQ

Name of Work:- Underground cabling work in place of overhead electric line including street lights from MMV Crossing to Law College Crossing, From Chittupur Gate to Near Non-Teaching Club (Partly) including Arbindo Colony, part of Kabir Colony & from Maitry Jalpan Grih Crossing to Akela Bir Baba Mandir Crossing, BHU.
Sl. No. Item Description
1Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification .(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm
2Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification .(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm
3Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground as an additional run including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm
4Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground as an additional run including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm
5Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm
6Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx120 Sq. mm
7Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm )
8Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 4Cx10 Sq. mm
9Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx25 Sq. mm
10Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 4Cx10 Sq. mm
11Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm
12Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx120 Sq. mm
13Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm
14Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size loose for connection etc as per CPWD specification.. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5C x 25 Sqmm
15Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size loose for connection etc as per CPWD specification.. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 4C x 10 Sqmm
16Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. (Make-Dowels/Comet/HMR/HBX/Jainson/Skytone) 3 ½ core x 95 sqmm (45mm)
17Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. (Make-Dowels/Comet/HMR/HBX/Jainson/Skytone) 3 ½ core x 120 sqmm (45mm)
18Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. (Make-Dowels/Comet/HMR/HBX/Jainson/Skytone) 4 core x 10 sqmm (28mm)
19Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. (Make-Dowels/Comet/HMR/HBX/Jainson/Skytone) 3 ½ core x 25 sqmm (28mm)
20Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. (Make-Dowels/Comet/HMR/HBX/Jainson/Skytone) 3 ½ core x 185 sqmm (57mm)
21Supplying and making outdoor and termination with cast resin compound including aluminum lugs and other jointing materials for following size of PVC insulated /XLPE aluminum conductor cable 1.1KV grade as required. (Make-Raychem/XION/3M/Denson/M--Seal) 3 ½ core x 185 sqmm
22Supplying and making straight through joint with heat shrinkable kit including ferrule and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (Make-Raychem/XION/3M/Denson/M--Seal/Capseal) 3 ½ core x 185 sqmm
23Earthing with G.I. earth pipe 4.5 meter long 40 mm dia including accessories and providing masonry enclose with cove plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Make-TATA Steel/Jindal Hissar/Sail/Prakash Surya)
24Providing and fixing 6 SWG dia dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
25Supplying and laying 25 mm x 5 mm G.I. strip at 0.50 meter below ground as strip earth electrode, including connection/termination with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut & bolt spring washer spaced at 50 mm)
26Providing and Erection (SITC) of L.T. Feeder Pillar of approx dimension 1000 (L) x 1250 (H) x 700 (D) mm without rain hood and mounting stand. (Specification of Feeder Pillar type 1 is enclosed as Annexure-IA) The work shall also include the excavation of earth in 1100mm depth, 1200mm length & 900mm width and making of four nos. RCC concrete column pillars each of dimension 250(L)x250(W)x1000(H). The column pillar shall be projected 450mm above from the furnished ground level. (Rough sketch of foundation in enclosed as Annexure-IIA) For the construction of foundation concrete materials (cement, sand, Stone) shall be used as per 1:4:8 ratio and reinforcement shall be done with 10mm & 8mm dia TMT rods for vertical & horizontal rings respectively. The work shall also include the leveling, alignment, Testing etc. After erection/ installation of L.T. Feeder Pillar, the excavated earth shall be back filled / rammed by the contractor at no-extra cost. The projected surfaces of RCC foundation shall be painted with water proof good quality paint of white colour in two coats at no-extra cost. Danger board shall be mounted wherever required to meet the relevant clause of Indian electricity rules. MS Apron of 2mm thick sheet shall be provided alround the stand of Feeder Pillar and shall be painted with the same colour as Feeder Pillar colour in same quility All the construction material viz stone, reinforcement, sand, cement, tools & tackles, consumables etc. required for the work shall be provided by the contractor at no extra cost. The main components of above Feedder Pillar shal be as follows: (Make- Neptune/Advance power/Associated Switchgear Pvt. Ltd./SPC Electrotech Pvt. Ltd./Application Control Panel/Allied Engineers/Excel control/Pritine/Precision/System Control etc.) a) 400 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 400A HRC fuses as incoming & interconnector feeders. -02 Nos. b) 250 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 250A HRC fuses as outgoing feeder. -01 No. c) 160 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 160A HRC fuses as outgoing feeders. -02 Nos. d) 01 No. 440V TPN 63A automatic lighting unhit with 50A HRC fuse along with 03 Nos. 63A fuse base and holder plus 01 No. neutral link & 01 No. 50A Triple pole power contactor with 2 NO + 2 NC auxiliary connect & 230V AC coil voltage 01 No. LCD Display Time switch 230V AC, 24 Hour dial 01 No. red colour start push button (self rest type), 01 No. green colour stop push button (self rest type) 01 No. auto/manual selector switch and 01 No. red colour LED type 230V AC indicator lamp 01 No. 16A HRC control fuse with 01 No. neutral link and appropriate size of copper TPN bus bars for connecting the TPMCB-3 Nos., DPMCB as detailed below a) 20-32 A, TPMCB 10/16 KA C-Curve - 3 Nos. b) 10 A DPMCB 10 KA C-Curve - 1 No Drawing shall be approved by the Engineer In-charge before fabrication.
27Providing and Erection (SITC) of L.T. Feeder Pillar of approx dimension 1000 (L) x 975 (H) x 700 (D) mm without rain hood and mounting stand. (Specification of Feeder Pillar type 2 is enclosed as Annexure-IB) The work shall also include the excavation of earth in 1100mm depth, 1200mm length & 900mm width and making of four nos. RCC concrete column pillars each of dimension 250(L)x250(W)x1200(H). The column pillar shall be projected 450mm above from the furnished ground level. (Rough sketch of foundation in enclosed as Annexure-IIA) For the construction of foundation concrete materials (cement, sand, Stone) shall be used as per 1:4:8 ratio and reinforcement shall be done with 10mm & 8mm dia TMT rods for vertical & horizontal rings respectively. The work shall also include the leveling, alignment, Testing etc. After erection/ installation of L.T. Feeder Pillar, the excavated earth shall be back filled / rammed by the contractor at no-extra cost. The projected surfaces of RCC foundation shall be painted with water proof good quality paint of white colour in two coats at no-extra cost. Danger board shall be mounted wherever required to meet the relevant clause of Indian electricity rules. MS Apron of 2mm thick sheet shall be provided alround the stand of Feeder Pillar and shall be painted with the same colour as Feeder Pillar colour in same quility All the construction material viz stone, reinforcement, sand, cement, tools & tackles, consumables etc. required for the work shall be provided by the contractor at no extra cost. The main components of above Feedder Pillar shal be as follows: (Make- As per Item No. 12) a) 400 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 400A HRC fuses as incoming & interconnector feeders. -02 Nos. b) 250 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 250A HRC fuses as outgoing feeder. -01 No. c) 160 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 160A HRC fuses as outgoing feeder. -01 No. d) 125 A, 415 V, 50 Hz., TPN Switch-Disconnector fuse unit complete with 125A HRC fuses as outgoing feeders. -02 Nos. Drawing shall be approved by the Engineer In-charge before fabrication.
28Providing and Erection (SITC) of L.T. Service Pillar of approx dimension 600 (L) x 550 (H) x 250 (D) mm without rain hood and mounting stand. (Specification of Service Pillar is enclosed as Annexure-IC) The work shall also include the excavation of earth in 800mm depth, 700mm length & 400mm width and making of two nos. RCC concrete column pillars each of dimension 200(L)x200(W)x1250(H). The column pillar shall be projected 500mm above from the furnished ground level. (Rough sketch of foundation enclosed as Annexure-II C) For the construction of foundation concrete materials (cement, sand, Stone) shall be used as per 1:4:8 ratio and reinforcement shall be done with 10mm & 8mm dia TMT rods for vertical & horizontal rings respectively. The work shall also include the leveling, alignment, Testing etc. After erection/ installation of L.T. Service Pillar, the excavated earth shall be back filled / rammed by the contractor at no-extra cost. The projected surfaces of RCC foundation shall be painted with water proof good quality paint of white colour in two coats at no-extra cost. Danger board shall be mounted wherever required to meet the relevant clause of Indian electricity rules. All the construction material viz stone, reinforcement, sand, cement, tools & tackles, consumables etc. required for the work shall be provided by the contractor at no extra cost. The main components of above Feedder Pillar shal be as follows: (Make- As per Item No. 12) a) 01 No. 440V TP 160A MCCB 36 KA as incoming Ics = Icu b) 40 A, TPMCB 10/16 KA C-Curve - 3 Nos. c) 20-32 A DPMCB 10 KA C-Curve - 9 Nos. Drawing shall be approved by the Engineer In-charge before fabrication.
29Providing and fixing of 100A three phase Neutral (TPN) 4 ways Busbar chamber box with overall dimension 400 X 610 X 190 mm with copper strips for all phases and neutral and should be operated at 440 V AC 50 Hz with fault capacity 10KA. The fixing of Busbar on wall surface shall be carried out by appropriate size and strength of anchor fastners nuts bolts cadium coated etc. (Make: Beltech/Socomac or equivalent)
30Supplying & erection of flange mounted hot dip galvanized octagonal poles of 6 mtrs. height made from 3 mm thick HR Steel plate having bottom dia of 130 mm & top dia of 70 mm complete with window sleeve type cover arrangement at a height of 0.5 mtrs from the base for cable termination block welded on both ends etc. and galvanized base plate of size 220 mm x 220 mm x 12 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination. Supply & fixing 6 mm thick laminated mounted sheet inside the window i/c providing mounting arrangement etc complete as reqd. Supply and fixing 63 amps. terminal block 8 nos. suitable for 1.1 KV grade 4CX 16 sq. mm Armoured cable - 4 Nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length on the existing laminated sheet.Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 No., earth stud -1 No., welded at suitable height one nos washers, springs washers & nuts. Provision on suitable height one onos washers sprinings washers & nuts. Provision on suitable height for fixing of additional bracket Cable supports clamps suitable for 4x10 /4 x 16 sq. mm cablePole Drawing should be approved by the Engineer In-chage(Make :- valmont/Bajaj/RR Ispat/Paruthi/Utkarsh/BPP/SALSAR) Drawing shall be approved by the Engineer In-charge before fabrication.
31Providing and laying in position (1:2:4) reinforced cement Concrete foundation of size 450 mm (L) X 450mm wide and 1200mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement ring of cold twisted bars of 12 mm dia 1350 mm long (approx) 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia -1800mm (approx) 8 nos. (with 150 mm spacing) as requried with positioning of foundation bolts and provoding 40 mm dia (O.D.) DWC, HDPE pipe of 0.3 mtrs. length for cable entry & exit as reqd.
32Supplying and Fixing 4 Nos. 20 mm dia. X 600mm long GI foundation \\"J\\" bolt(EN8 grade) with nuts,washer including 2 Nos. template of 2 mm thick size 200mmX200mm with 4 Nos. 24mm dia holes to match with PCD of Pole base plate as reqd.
33Fabrication, supplying & fixing of single/double/tripple over hang galvanized arm bracket made out of Suitable dia & 500 mm to 1500 mm long & top tube with suitable dia etc complete as required.(Design as per approved sample).
34Supplying and drawing following size of PVC insulated copper conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.3 core 1.5 sq.mm 1.1 KV grade
35LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥ 105 < 120 lm/ Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50° C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC. 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Make: Philips/Wipro/Crompton/Surya/Polycab/Havells/LT/Trilux/Orient/Regant. 120 Watt
36LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥ 105 < 120 lm/ Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50° C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC. 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Make: Philips/Wipro/Crompton/Surya/Polycab/Havells/LT/Trilux/Orient/Regant. 150 Watt
37LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver asper the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Make- Same as Item No. 21 150 Watt
38Dismantling of overhead lines comprising of aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required.
39Dismantling of pole (RCC/ST)/ Rail pole street light standard/ strut embedded in brick ballast foundation etc. as required.
40Providing, laying and fixing 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(Make-B class -Jindal/TATA/QST)
41Providing and surface laying of G.I. pipe 40 mm dia make: Jindal/TATA/QST class B
42Supplying and erection of stay set complete (galvanized) with 19/20 mm dia x 1.8 meter long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble, stay clamps, turn buckle (20 mm x 60 cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
43Supply and making cable route maker with cement concrete 1:2:4 (1 cement:2coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.
44Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (Make-Rex/Duraline/Gemini/Triputi/Astral/Supreme) 63 mm dia (OD-63 mm & ID-51 mm nominal)
45Credit for old dismantled Swaged/G.I. Tubular pole of avarage Height 10 Mtr.
46Credit for old dismantled Aluminium ACSR Condutors Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58431483
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.93 Crore
LAST DATE 19-11-2026
Authority
Authority Name Banaras Hindu University
Work Description Tender for Underground Cabling Work In Place Of Overhead Electric Line Including Street Lights From Mmv Crossing To Law College Crossing, From Chittupur Gate To Near Non-Teaching Club (Partly) Including Arbindo Colony, Part Of Kabir Colony & From Maitry Jalpan Grih Crossing To Akela Bir Baba Mandir Crossing, Bhu.
Basic Detail
Tender No EWSS/UED/2026/06112026-1
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 06 Nov 2026
Submission Date 19 Nov 2026
Open Date 24 Nov 2026
Finance
Tender Value 1.93 Crore
Tender Fee 500
EMD 3.87 Lakhs
Exemption Not Available
Document List
b33244bd-31dd-4323-a711-163ab0252943.html
BOQ_981059.xls
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

b33244bd-31dd-4323-a711-163ab0252943.html

xls

BOQ_981059.xls

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender