Tender For Sh-Running ,Maintenance And Operation Of Internal Electrical Installation, Compound Lighting I/C Iei Work Etc At Community Hall (Near Sainik Vihar And Rishi Nagar) Rani Bagh, Pitampura And Community Hall Shastri Nagar.
Tender Overview
Project Description
Tender for Sh-Running ,Maintenance And Operation Of Internal Electrical Installation, Compound Lighting I/C Iei Work Etc At Community Hall (Near Sainik Vihar And Rishi Nagar) Rani Bagh, Pitampura And Community Hall Shastri Nagar.
BOQ
| Sl. No. | Item Description |
| 1 | Maintenance, cleaning and testing of electrical &mechanical IEI installations on weekly basis such as compound lighting and internal electrical installations as per terms & conditions and inventory enclosed by deplolying following staff. A)1 no.wireman and 1 No.khallasi-2 days in a week in general shift and as and when required for Community Hall (near SainikVihar& Rishi Nagar) Rani Bagh, Pitampura and community hall Shastrinagar. |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C |
| 3 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 4 | Rewinding of existing damaged/burnt out ceilling fan of 1200 sweep size in all respect i/c dismantling the existing fan and refixing the same with connection, testing etc complete as required. |
| 5 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.20.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not risę above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness 1.20 mm) (A-40 watt) |
| 6 | Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthingetc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 7 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 P. F.20.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (A 120 watt)Installation, Testing, Commissioning and replacing at the place of old existing fan i/c dismantling and rebate for dismentalled material. |
| 8 | Supply and fixing of following electrical wiring from deputed labour accessories i/c connection, testing etc complete as required. |
| 9 | 3 mm thick phenolic laminated sheet |
| 10 | 5/6 amp one way switch piano type ISI marked |
| 11 | 15/16 amp one way switch piano type ISI marked |
| 12 | 3 pin 5/6 amp socket outlet piano type ISI marked |
| 13 | 6 pin 15/16 A & 5/6A socket outlet Piano type ISI marked |
| 14 | Supplying and drawing of FRLS/HFFR PVC insulated single core copper condutor cable in the existing surface/receses, steel/PVC conduit |
| 15 | 1.5 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable |
| 16 | 2.5 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable |
| 17 | 4 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable |
| 18 | Supplying and fixing of 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete i/c with connections, testing and commissioning etc. as required |
| 19 | Single pole |
| 20 | Double Pole |
| 21 | Lifting out of the existing submersible pump set from the existing bore well i/c dismantling the pipe line and pump set &submersible cable with the help of tri post block etc. as required. |
| 22 | Lowering the submersible pump set after repairing the pump set in the existing bore well i/c making of connection of pump set and pipe line providing with rubber packing & nut bolts, making of water proof joint of submersible cable, testing commissioning etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender