Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58431243

Tender For Provision Of Deficient Lifts In Gulab Building At Robert Complex Under Ge (Nw) Nofra

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
19 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Deficient Lifts In Gulab Building At Robert Complex Under Ge (Nw) Nofra

BOQ

Name of Work:- PROVISION OF DEFICIENT LIFTS IN GULAB BUILDING AT ROBERT COMPLEX UNDER GE (NW) NOFRA
Sl. No. Item Description
1Design, manufacture, supply, installation, testing and commissioning of 13-passenger Machine Room Less (MRL) passenger lift, suitable for serving Ground + 3 upper floors (G+3), 4 stops, complete in all respects with all standard accessories, safety devices, controls, signalling arrangements, electrical connections and other equipment necessary for satisfactory and safe operation, comprising the following: 1. Type of Lift: Passenger Lift, Machine Room Less (MRL); 2. Rated Capacity: 13 passengers / 884 kg minimum; 3. Rated Speed: 1.0 m/s; 4. Number of Stops: 04 Nos., serving Ground, First, Second and Third Floors (G+3), with all landings having same-side opening; 5. Operation: Simplex full collective automatic operation with/without attendant; 6. Power Supply: 415 V, 3 Phase, 50 Hz AC; 7. Drive: AC Variable Voltage Variable Frequency (VVVF), closed-loop controlled; 8. Machine: Gearless Permanent Magnet Synchronous Motor (PMSM), suitable for MRL application; 9. Machine Arrangement: Machine Room Less arrangement, with lift machinery and control equipment suitably accommodated within the hoistway/landing arrangement as per approved manufacturer's design; 10. Controller: Microprocessor-based integrated lift controller with closed-loop VVVF drive; 11. Door Drive: AC VVVF-controlled, closed-loop, PM motor-operated door drive; 12. Lift Car: Standard manufacturer's construction with MS structural frame and stainless steel sheet of minimum 1.5 mm thickness having hairline finish, internal dimensions approximately 1500 mm (W) x 1500 mm (D) x 2300 mm (H) or equivalent, with minimum usable floor area of 2.20 m², complete with stainless steel false ceiling, LED lighting, concealed ventilation/cross-flow fan with automatic cut-off arrangement and all necessary fittings and accessories;
213. Car Door : Automatic centre-opening/telescopic sliding type with VVVF-controlled door operator, PM motor, clear opening approximately 900 mm wide x 2000 mm high, fabricated from stainless steel sheet minimum 1.2 mm thick with hairline finish, complete with door hangers, tracks, rollers, guides, locks, interlocks and all necessary accessories; 14. Landing Doors: Automatic centre-opening/telescopic sliding type at all four landings, clear opening approximately 900 mm wide x 2000 mm high, fabricated from stainless steel sheet minimum 1.2 mm thick with hairline finish, complete with frames, sills, hangers, tracks, rollers, guides, locks, interlocks and all necessary accessories, with fire-rated construction as specified for the installation and supported by required test certification; 15. Hoistway: RCC hoistway construction having clear internal dimensions approximately 2500 mm wide x 1900 mm deep, subject to final approved lift manufacturer's requirements and shop drawings, including coordination of pit depth, overhead clearance, sill levels, supports, openings and embedded items; 16. Guide Rails: Suitable machined T-section mild steel guide rails for car and counterweight, complete with brackets, fishplates, fasteners and accessories, with indicative sizes of 89 mm x 62 mm x 16 mm for car and 70 mm x 65 mm x 9 mm for counterweight; 17. Buffers: Suitable terminal buffers of approved type and capacity for car and counterweight, complete with supporting arrangements;
318. Counterweight: Suitable counterweight frame with cast iron/MS profile weights, properly calculated for rated capacity and manufacturer's design requirements; 19. Car Operating Panel: One number stainless steel car operating panel with hairline-finish face plate, luminous push buttons, floor selection, door open/close, alarm/emergency button, emergency communication facility, overload indication, car position indication, direction indication, fireman's operation provision and other controls required for safe operation; 20. Landing Controls and Indicators: Luminous hall call push buttons and LED floor position/direction indicators at each landing; 21. Indicators and Annunciation: LED car position indicator in COP, car and landing direction indicators and audible floor arrival/annunciation system indicating the floor reached by the lift car and suitable audible indication associated with opening/closing of car entrance doors; 22. Safety Devices: Complete with all standard statutory and manufacturer's safety devices, including full-height infrared door safety sensor/light curtain across the entire door opening, overload protection with visual display and audible buzzer indication, and one number fireman's switch at Ground Floor near the landing entrance; 23. Automatic Rescue Device: Suitable Automatic Rescue Device (ARD)/Automatic Landing Device complete with maintenance-free rechargeable batteries, battery charging arrangement and associated equipment, capable of automatically bringing the lift car to a suitable landing during failure of normal power supply for safe passenger exit; 24. Emergency Lighting and Alarm: Rechargeable battery-operated emergency light, battery-operated alarm bell and suitable maintenance-free rechargeable battery, with emergency illumination independent of normal car lighting supply;
425. Emergency Communication: Suitable two-way emergency communication/telephone system between lift car and designated receiving/communication point, including one number wall-mounted telephone instrument of approved make such as Crompton Greaves/Beetel or equivalent approved make, complete with mounting arrangement and suitable communication cable through approved wiring/travelling cable arrangement; 26. Announcing/Intercom System: Built-in announcing/emergency communication system including suitable press-and-speak type communication arrangement and necessary communication points between lift car, Ground Floor/designated landing and lift control/maintenance location, complete with cables, control units, speakers, microphones, power supply units and accessories; 27. Siren: One number electrically operated siren rated for 240 V operation, having suitable audible range, with independent switch/control arrangement inside lift car and complete with necessary cables, conduits and accessories; 28. Electrical Wiring: Complete internal electrical wiring, control wiring, FRLS cables, power connections, conduits, cable supports, terminals, MCBs/protective devices and all electrical accessories required for complete operation of the lift, including proper identification, termination and support of all wiring; 29. Earthing: Complete earthing and bonding of all metallic parts of the lift installation to the prescribed earthing system; 30. Testing and Commissioning: Complete testing, adjustment, balancing and commissioning of the lift under no-load and rated-load conditions, including testing and demonstration of all safety devices, controls, door operation, emergency systems, ARD, indicators, alarms and communication systems, and submission of manufacturer's test certificates, inspection reports, commissioning reports, operation and maintenance manuals, warranty documents and all other documents required for handing over, including statutory inspection/approval and certificates applicable to the installation, complete all specified and directed by the Engineer-in-Charge.
5Material and labour for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 32 mm x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation and earthwork in any type of soil including chamber in PCC 1:3:6 type C1,50 mm thick precast RCC cover slab in 1:2:4 type B1 reinforced with 8 mm TMT bars @ 100 c/c. MS handle 6 mm dia,watering arrangement with funnel internally secured with wire mesh ,20 mm bore medium grade for watering , 40 mm GI pipe light grade for lead protection including alternate layer of charcoal dust and common salt complete all as specified and shown in electrical plate No. 3 connected to earthing test point complete all as specified and directed by Engr -in- Charge or indicated including testing on completion complete all as specified and directed.
6Providing, laying and fixing of 25 mm x 4 mm galvanised iron (GI) strip from the designated earth test point to the lift machine/control equipment location, supported on porcelain insulators at intervals not exceeding 500 mm, with suitable clamps, nuts, bolts and accessories. The GI strip shall be securely fixed without touching the wall and shall be laid in a neat and straight manner without sharp bends, kinks or unnecessary offsets, including cutting, jointing, drilling, fixing and making good all surfaces, complete all as specified and directed by the Engineer-in-Charge.
7Supplying and fixing in repairs factory-fabricated sheet metal enclosure for MCCB, made of cold-rolled close-annealed (CRCA) sheet steel not less than 1.6 mm thick, equipped with hinged front door, locking arrangement, neoprene gasket sealing, and welded MS flat/angle iron mounting framing on all sides for rigid fixing to wall, complete with 100 Ampere Four-Pole (4P) Moulded Case Circuit Breaker (MCCB) of 415 V rating with short-circuit breaking capacity of not less than 16 kA, including making all internal cable/busbar terminations, neutral link, earthing studs, testing, commissioning complete all as specified and directed.
8Material and labour for repairs to lift architrave using 16–18 mm thick machine cut mirror polished black granite slab, decorative design with chamfered/rounded edges, including necessary PCC work, jointing in cement slurry and pointing with white cement mixed with pigment to match shade of granite, complete all as specified and directed by Engineer-in-Charge.
9Taking down cement or cement lime plaster, any description, on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., and including removal of all resulting rubbish and debris off MD premises, complete all as specified and directed.
10Material and Labour for rendering 20 mm thick on stone masonry surfaces or surfaces other than fair face of brickwork (external wall surfaces), consisting of 10 mm thick base coat in cement mortar 1:4 and 10 mm thickness in cement mortar 1:4,finshing coat mixed with integral water-proofing compound at 3% by weight of cement (or as per manufacturer's instructions),including necessary scaffolding and safety arrangement complete all as specified and directed (Note: Water-proofing compound shall be included in the quoted item).
11Material and Labour for preparation of new or previously untreated surfaces of any description, including cleaning, wire-brushing, washing down, and applying one coat of exterior wall primer followed by two coats of 100% acrylic emulsion of approved shade and manufacture on wall or roof surfaces, complete all as specified and directed.
12Supplying, laying, and testing XLPE insulated, PVC bedded, galvanised steel strip or wire armoured heavy-duty electric power cable, 1100 Volts grade, with stranded aluminium conductors of size 3.5 Core × 50 sq. mm, laid in existing masonry/RCC ducts, or clamped along walls/ceiling/steel structures/poles using GI saddles or cleats at intervals not exceeding 60 cm, including making end terminations and connections complete, all as specified and directed by the Engineer-in-Charge.
13M&L for demolition of existing wall of lift shaft, of any size and thickness, for providing opening for lift landing door at each floor, as per site requirements, including careful demolition without causing damage to adjoining structures, finishing of all disturbed surfaces, making good the plastered surfaces to match the existing adjacent surface in texture and finish, collection and removal of all debris, rubbish and dismantled materials from the site to an approved location outside the station, and making good all damages caused during the work, complete all as specified and directed by the Engineer-in-Charge.
14M&L for providing and casting 200 mm thick RCC waterproof slab over the existing lift shaft at an overhead height of approximately 5800 mm, including all necessary centering, shuttering, reinforcement, supports and structural arrangements required for casting the slab within the lift shaft, including dismantling and removal of existing old GI structure/steelwork inside the lift shaft, stacking or disposal of dismantled materials as directed, making good all disturbed surfaces and finishescomplete all as specified and directed by the Engineer-in-Charge.
15Note :All quoted item rates shall be fully inclusive of supplying, erecting, maintaining, shifting, and dismantling double-pole steel scaffolding, staging, safety nets, and protective screens required at any height or floor level (if necessary). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58431243
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Deficient Lifts In Gulab Building At Robert Complex Under Ge (Nw) Nofra
Basic Detail
Tender No 8710/CWE(NW)MUMBAI/E8
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 07 Nov 2026
Submission Date 26 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
1726f275-33d4-4112-9d46-09c20b206627.html
8710.rar
BOQ_894379.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

1726f275-33d4-4112-9d46-09c20b206627.html

rar

8710.rar

xls

BOQ_894379.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender