Tender For Repair /Maintenance To Contactors Starter, Mccb, Pump Sets, Lt Panel Boards And Connected Items At G/B Ph, Mithun Treated Water Ph, Cph, Anph, Jd And Dhanush Pump House Area Under Ge (Nw) Navynagar, Colaba Mumbai.
Tender Overview
Project Description
Tender for Repair /Maintenance To Contactors Starter, Mccb, Pump Sets, Lt Panel Boards And Connected Items At G/B Ph, Mithun Treated Water Ph, Cph, Anph, Jd And Dhanush Pump House Area Under Ge (Nw) Navynagar, Colaba Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning in replacement of LT Panel board indoor type from CPRI approved panel manufacturer made out of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 600A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V,400Amps 50 KA - 02 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100%(b) MCCB 4 pole,415V,250 Amps, 36 KA - 04 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% ( c) Change over switch front open hand operated 400 Amp - 1 No.(d) Automatic star/Delta starters panel with all accessories mounting suitable for 75 HP-02 Nos.and 40 HP-02 Nos(e) Phase indicating lamps(RYB)-04 set(f) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set.(g) Suitable CTs for main and for 04 starter panels.Note: before fabrication of panel, the contractor has to take approval from accepting officer on drawing. |
| 2 | Supply, installation, testing and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V,630Amps 50 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100%(b) MCCB 4 pole,415V, 630 Amps, 36 KA - 01 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% ( c) MCCB 4 pole,415V, 100 Amps, 36 KA - 01 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100%(d) MCCB 4 pole,415V, 63 Amps, 25 KA - 01 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100%(e) Phase indicating lamps(RYB)-04 set(f) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set.(g) Suitable CTs for main and for 04 starter panels.Note: before fabrication of panel, the contractor has to take approval from accepting officer on drawing. |
| 3 | Supply, installation, testing and commissioning in replacement of automatic mains failure (AMF) panel,indoor type floor mounted, free standing, CPRI approved panel manufacturer made out of of 2 mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire, 50 HZ , 415 Volt AC supply with 600A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V, 300 Amps 36 KA - 04 No (1 motor main + 1 DG + 2 for outgoing) thermo magnetic adjustable release type,ICS=ICU=100%(b) Contactor rating 300 Amps, 4 pole,415V - 02 Nos (c) AMF Controller - 01 Nos(d) Digital Mulfunctioning meter - 01 Nos(e) Battery Charger-01 Nos(f) Control relays - 05 Nos(g) Auto manual selector switch - 01 Nos(h) Control MCB 16A SPN - 02 Nos and 16A 4P - 01 Nos(e) Phase indicating lamps(RYB)-03 set(f) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set.(g) Suitable CTs for main and for 04 starter panels.Note: before fabrication of panel, the contractor has to take approval from accepting officer on drawing. |
| 4 | Supply, installation, testing and commissioning in replacement of LT Panel board indoor type from CPRI approved panel manufacturer made out of 3.15 mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V,630Amps 50 KA - 02 Nos (incoming) thermo magnetic adjustable release type,ICS=ICU=100% (b) On load change over switch 630 Amps, 4 pole, 415 volts-01 No. (c) MCCB 4 pole, 415V,400Amps 50 KA - 03 Nos (Out going) thermo magnetic adjustable release type,ICS=ICU=100% (d) Phase indicating lamps(RYB)-04 set(e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-01 set. |
| 5 | M& L for Disconnecting centrifugal pump from motor, suction and delivery pipe line of any Make, model and taking down packing for removing and insertion of new shaft sleeves or remove Bearing using bearing puller gear and fix new all two bearings and greasing all parts, coupling pump to motor and check for proper shaft alignments such that no vibration produce during opertion of following capacity pumps, complete all as specfied and as directed by Engineer-in-charge. (a) Bearings suitable for Pump coupled with 150 HP motor Make:SFC/NBC/SKF |
| 6 | Bearings suitable for Pump coupled with 120 HP motor . |
| 7 | Bearings suitable for Pump coupled with 100 HP motor . |
| 8 | Bearings suitable for Pump coupled with 75 HP motor . |
| 9 | Bearings suitable for Pump coupled with 60 HP motor . |
| 10 | Bearings suitable for Pump coupled with 50 HP motor . |
| 11 | Bearings suitable for Pump coupled with 30 HP motor . |
| 12 | Bearings suitable for Pump coupled with 20 HP motor. |
| 13 | S&F in repair AC-3 type contactor with control voltage of 415V AC, 50 Hz with integrated auxillary or Add on block contacts with 1 or 2 NO and NC including connection of control wiring to contactor and testing of starter after repairing .(a) Contactor rating of between 140A to 185A Make L &T/Havells/C&S/Legrand |
| 14 | Contactor rating of between 110A to 140A |
| 15 | Contactor rating of between 80A to 110A |
| 16 | Contactor rating of between 45A to 80A . |
| 17 | Contactor rating of between 32A to 45A . |
| 18 | Contactor rating of between 18A to 32A . |
| 19 | S&F in repair Thermal over load relay with adjustable setting with integrated auxillary or Add on block contacts with 1 or 2 NO and NC including connection of control wiring to OLR and testing of starter after repairing . (a) OLR of capacity I Min of 135 to I max 225A Make L &T/Havells/C&S/Legrand |
| 20 | OLR of capacity I Min of 78 to I max 130A. |
| 21 | OLR of capacity I Min of 69 to I max 115A . |
| 22 | OLR of capacity I Min of 52 to I max 75A . |
| 23 | OLR of capacity I Min of 45 to I max 65A. |
| 24 | M& L for Disconnecting motor from pump of any Make, model and remove Bearing using bearing puller gear and fix new all two bearings at DE /NDE including necessary greasing ,check for proper shaft alignments such that no vibratiobn produce during opertion of following capacity Motors. (a) Bearings suitable for 150 HP motor coupled with pump Make:SFC/NBC/SKF |
| 25 | Bearings suitable for 120 HP motor coupled with pump . |
| 26 | Bearings suitable for 100 HP motor coupled with pump . |
| 27 | Bearings suitable for 75 HP motor coupled with pump . |
| 28 | Bearings suitable for 60 HP motor coupled with pump. |
| 29 | Bearings suitable for 50 HP motor coupled with pump . |
| 30 | Bearings suitable for 30 HP motor coupled with pump . |
| 31 | Bearings suitable for 20 HP motor coupled with pump. |
| 32 | S&F self lubricated asbestoes non metallic and non graphite gland packing white colour of sizes 8 to 12 mm complete all as specified and directed . |
| 33 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 150 HP motor |
| 34 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 100 HP motor |
| 35 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 75 HP motor |
| 36 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 60 HP motor |
| 37 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 50 HP motor |
| 38 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 30 HP motor |
| 39 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 20 HP motor |
| 40 | S & F in repairs 300 mm dia MS pipe heavy grade, ISI marked for suction and deliver for pump including necessary fitting including welding, painting with red oxide primer and providing necessary PCC support, all as specfied and directed by Engineer-in-charge. |
| 41 | S & F in repairs 150 mm dia MS pipe heavy grade, ISI marked for suction and deliver for pump including necessary fitting including welding, painting with red oxide primer and providing necessary PCC support, all as specfied and directed by Engineer-in-charge. |
| 42 | S & F in repairs 100 mm dia MS pipe heavy grade, ISI marked for suction and deliver for pump including necessary fitting including welding, painting with red oxide primer and providing necessary PCC support, all as specfied and directed by Engineer-in-charge. |
| 43 | S & F in repairs 80 mm dia MS pipe heavy grade, ISI marked for suction and deliver for pump including necessary fitting including welding, painting with red oxide primer and providing necessary PCC support, all as specfied and directed by Engineer-in-charge. |
| 44 | Supply and fix in repairs 300 mm size CI foot valve ball type flanged end IS 4038 PN 0.2 housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed. |
| 45 | Supply and fix in repairs 150 mm size CI foot valve ball type flanged end IS 4038 PN 0.2 housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed. |
| 46 | Supply and fix in repairs 100 mm size CI foot valve ball type flanged end IS 4038 PN 0.2 housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed. |
| 47 | M&L for Disconnecting motor power cables of various sizes from electrical motor of different capacities and decoupling from the pump sets,removing and taking down carefully and transporting to authorised workshop ,Dismantaling stator and rotor carefully and rewinding stator assembly with supper enamelled copper winding wire of suitable gauge matching to existing gauge and cleaning of slots ,core with carbon tetra chloride solution and apply two coats of insulation varnish and keep stator assembly in heating chamber to improve insulation strength ,reassemble motor completey and transporation to site ,coupling pump to motor and check for proper shaft alignments such that no vibratiobn produce during opertion coupling to pump with exact allinment ,connect power cables to motor and testing of following capacity motor (a) 150 HP |
| 48 | (b) 120 HP |
| 49 | (c) 100 HP |
| 50 | (d) 75HP |
| 51 | (e) 60 HP |
| 52 | (f) 50 HP |
| 53 | (g) 30 HP |
| 54 | (h) 20 HP Please Enable Macros to View BoQ information |
| 55 | (h) 20 HP Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender