Tender For Reshifting/Rerouting Of Electrical Infrastructure Alongwith With Ht/Lt Cable Near Nav Mart Canteen Under Ge(U) Elect Supply Delhi Cantt-10.
Tender Value
30 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
20 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Reshifting/Rerouting Of Electrical Infrastructure Alongwith With Ht/Lt Cable Near Nav Mart Canteen Under Ge(U) Elect Supply Delhi Cantt-10.
BOQ
| Sl. No. | Item Description |
| 1 | M & L for taking out HT/LT 11 KV/1.1 KV UG cable of following sizes at site from trench including excavation ,returning & filling in properly for reuse complete all as specified and directed by Engg-in-charge. |
| 2 | 300 sqmm, 3core, HT 11KV |
| 3 | 185 sqmm, 3core, HT 11KV |
| 4 | 400 sqmm, single core, LT 1.1KV |
| 5 | 300 sqmm, 3.5core, LT 1.1KV |
| 6 | 185 sqmm, 3.5core, LT 1.1KV |
| 7 | 70 sqmm, 3.5core, LT 1.1KV |
| 8 | Labour and T&P only for relaying the HT/LT cables of following sizes in any position including excavation, returning & filling in properly for reuse complete all as specified and directed by Engg-in-charge. Note: DWC Pipe shall be measured and paid separately. |
| 9 | 300 sqmm, 3core, HT 11KV |
| 10 | 185 sqmm, 3core, HT 11KV |
| 11 | 400 sqmm, single core, LT 1.1KV |
| 12 | 300 sqmm, 3.5core, LT 1.1KV |
| 13 | 185 sqmm, 3.5core, LT 1.1KV |
| 14 | 70 sqmm, 3.5core, LT 1.1KV |
| 15 | Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) (E) of following sizes with multistranded aluminum conductors, 11 KV/1.1KV grade, IS 7098 marked, laid in trenches including jointing & testing complete all as specified and directed by Engg-in-charge.Note:- ( Excavation, earth work, cable protection, DWC Pipe, cable joint shall be measured and paid separately.) |
| 16 | 300 sqmm, 3core, HT 11KV |
| 17 | 185 sqmm, 3core, HT 11KV |
| 18 | 400 sqmm, single core, LT 1.1KV |
| 19 | 300 sqmm, 3.5core, LT 1.1KV |
| 20 | 185 sqmm, 3.5core, LT 1.1KV |
| 21 | 70 sqmm, 3.5core, LT 1.1KV |
| 22 | Supply and fixing of cable jointing kit for 11 KV/ 1.1KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core/3.5 core/ single core XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed by Engg-in-charge. |
| 23 | 300 sqmm, 3core, HT 11KV |
| 24 | 185 sqmm, 3core, HT 11KV |
| 25 | 400 sqmm, single core, LT 1.1KV |
| 26 | 300 sqmm, 3.5core, LT 1.1KV |
| 27 | 185 sqmm, 3.5core, LT 1.1KV |
| 28 | 70 sqmm, 3.5core, LT 1.1KV |
| 29 | M&L for excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply and laying of DWC pipe on surface/trench for cable protection of following sizes complete all as specified and directed by engineer –in-charge. |
| 33 | 110mm |
| 34 | 160mm |
| 35 | M&L for manual boring of hole under road, pavement, hard standing by manually for laying cable including HDPE pipe of suitable size as specified and directed complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for disconnecting the HT/LT supply, Earthing Strip from Existing Transformers and reshifting the same from the existing plinth to another location nearby including construction of new plinth/RCC/PCC structure and Reconnecting the HT/LT Supply after shifting the transformer complete all as specified and directed by Engg-in-charge. |
| 37 | M&L for disconnecting the HT/LT supply, Earthing Strip from Existing RMU and reshifting the same from the existing plinth to another location nearby including construction of new plinth/RCC/PCC structure and Reconnecting the HT/LT Supply after shifting the RMU complete all as specified and directed by Engg-in-charge. |
| 38 | M&L for disconnecting the LT supply, Earthing Strip from Existing Panels and reshifting the same from the existing plinth to another location nearby including construction of new plinth/RCC/PCC structure and Reconnecting the LT Supply after shifting the LT Panel complete all as specified and directed by Engg-in-charge. Please Enable Macros to View BoQ information |
| 39 | M&L for disconnecting the LT supply, Earthing Strip from Existing Panels and reshifting the same from the existing plinth to another location nearby including construction of new plinth/RCC/PCC structure and Reconnecting the LT Supply after shifting the LT Panel complete all as specified and directed by Engg-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer