Tender For Provn Of 12 X Street Light For Area Illumination Of Fence To Bdy Wall Of Sector-C Zone And Other Sanctioned Work At Bikaner Mil Stn Under Ge (N) Bikaner.
Tender Value
38.70 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
18 days left
EMD
77400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of 12 X Street Light For Area Illumination Of Fence To Bdy Wall Of Sector-C Zone And Other Sanctioned Work At Bikaner Mil Stn Under Ge (N) Bikaner.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre depth for laying of UG cable / pole etc. getting out including forming bottom surface to required level and gradient in soft/loose soil complete all as specified and directed. |
| 2 | Returning and filling in excavated soil including spreading levelling, watering, well ramming in layers not exc 25 Cm thick complete all as specified and directed. |
| 3 | Removing of excavated materials not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Supply and laying of DWC pipe inner dia 75 mm and outer dia 90mm confirming to IS 16205 for protection of LT UG cable of size 25 sqmm to 95 sqmm complete all as specified and directed. |
| 5 | M & L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping of pole etc. including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed. |
| 6 | Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe, including brass cable glands, clamps etc. of size 4 core x 10 sqmm including taking down of existing cable complete all as specified and directed. |
| 7 | Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe , including brass cable glands, clamps etc. of size 4 core x 16 sqmm including taking down of existing cable complete all as specified and directed. |
| 8 | Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe , including brass cable glands, clamps etc. of size 4 core x 25 sqmm including taking down of existing cable complete all as specified and directed. |
| 9 | Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe , including brass cable glands, clamps etc. of size 3.5 Core x 35 sqmm including taking down of existing cable complete all as specified and directed. |
| 10 | Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe , including brass cable glands, clamps etc. of size 3.5 Core x 70 sqmm including taking down of existing cable complete all as specified and directed. |
| 11 | S&F in replacement Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc. suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified directed. |
| 12 | S&F in replacement Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc. suitable for 70 Sqmm to 150 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified directed. |
| 13 | S&F GI Pipe light grade of size 40 mm bore with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories for protection of cable complete all as specified directed. |
| 14 | S&F GI Pipe light grade of size 50 mm bore with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories for protection of cable complete all as specified directed. |
| 15 | Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 Metre below the Road Surface with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and directed. Note : GI Pipe laid will be measured and paid separately under appropriate Item. |
| 16 | S&F in replacement for Cable jointing kit for LV/LT 1100 V cable for straight through, heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified directed. |
| 17 | S&F in replacement for Cable jointing kit for LV/LT 1100 V cable for straight through, heat shrinkable type joint kit complete with jointing material and accessories suitable for 70 Sqmm to 150 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified and directed. |
| 18 | S&F in replacement MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism Adjustable type complete with spreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified and directed. |
| 19 | S&F in replacement MCCB, 160 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism Adjustable type complete with spreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified and directed. |
| 20 | S&F in replacement MCCB, 200 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and fast tripping mechanism Adjustable type complete with spreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified and directed. |
| 21 | S&F in replacement MCCB,250 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism Adjustable type complete with spreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified and directed. |
| 22 | Supply, installing, commissioning and testing factory made and tested (CPRI type test certified) LT Panel board cubical type out door of size as per IS specifications, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-53, dust & vermin proof for outdoor use, made out of CRCA sheet 3.15 mm thick, powder coated inside & outside of flint grey shade (RAL-7032), machine pressed, both side opening in two halves with provision of rubber beading and locking system, including Al bus bar of 350 Amp capacity, 4 strip in colour code mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers for each MCCB / cubical switch shall have the independent opening, panel shall be mounted on angle iron frame and legs made from angle of size 50x50x5 mm including internal wiring with PVC insulated stranded copper conductor FRLSH cables of appropriate size but not less than 6 sqmm with proper ferrule & cable glands, including danger notice sticker, comprising & including the following accessories:- Incomer (a) MCCB, 400 Amps 36 kA, 4 Pole, Icu=100% Ics with built in protection functions for overload, short circuit current adjustable type complete with spreader link and extendable ON/OFF rotary handle - 01 No. (Incomer). (b) MCCB 250Amp 25 kA, 4 Pole, with built in protection functions for overload, short circuit current complete with spreader link and extendable ON/OFF rotary handle - 07 Nos (Outgoing). (c) MCB 32 Amp 10 kA, 2 Pole, -2 Nos (Outgoing). (d) Indicator Set RYB, “LED” type (set of three) -01 Set(e) Digital Amp meter (0-300) Amp with built in selector switch including necessary CTs (set of three) - 1 Set(f) Digital Volt meter with built in selector switch (0-500) - 01 No. Cost for taking down old unservicable LT Panel boards are also included in the unit rate quoted. |
| 23 | S & F in replacement Junction Box of size (H X W X D) 300x200x105 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66 with integrated membranes/metric knockouts for cable entry with cable glands, protection and suitable size of \\"connectwell\\" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on tubular/PCC pole with suitable clamps, nuts, bolts including removal of exiting unsv complete all as specified and directed. |
| 24 | S&F in replacement of LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellent thermal management, toughned glass and high power LED's with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120 lumen/watt and a minimum system lumen output of not less than 4950 lumens and maximum system wattage 70 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical impact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KV external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 .LED light fittings to bbe connected with existing bracket and pole by using twin insulated copper cable of size 2.5 sq mm size for each connection of light upto a length of 9.5 mtr long. |
| 25 | M&L for earthing complete with GI Earth Plate Electrode 600mm x 600mm x6mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to GI wire as earth lead 4 mm dia drawn through and including Galvanised Iron protection Pipe 15 mm bore (dia) Light grade upto 1.0 Metre above the ground level of the HT pole foundation where PCC pole is situated by means of Bolts, Nuts, Check Nuts and Washers etc. Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion including taking down unserviceable earting and connected Items, complete all as specified and as directed. |
| 26 | S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410-SP-31 (9.0 metres long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and interally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer including marking of pole number with black paint in yellow circle complete all as specified and directed.(Note:- Necessary earth work, PCC coping will be measured and paid for separately under respective items.) |
| 27 | S&F street light junction box made up of 3 mm thick CRCA Sheet steel enclosure front openable including MS Fixing clamps made up of 32 x 6 mm MS flat duly painted, GI nuts, bolts and washers of suitable size and the size of junction box shall not be less than 30 cm x 27 cm x 15 cm having 200 Amps rated aluminium bus bar of length not less 15 cm long for 3 phase 4 wire system mounted on Porcelain/epoxy insulators and provn of one MCB SP 2.5 to 6.0 Amps with locking arrangement complete all as specified and directed. |
| 28 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for foundation of pole complete all as specified and as directed |
| 29 | M&L for earthing complete with galvanized steel pipe electrode size 40 mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connected with and including GI strip of size 32x 6 MM by means of bolts and nuts check nut and washer of galvanized iron with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion including taking down old unsv earthing, complete all as specified and directed. Note :- (i) RCC pit cover shall be cast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lie if CI cover and the rate includes in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate. (iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate. |
| 30 | S&F sub main wiring with PVC insulated & PVC sheathed copper conductor flexible cable 2.5 sqmm served with an inner sheathing of PVC tape, 1100 volts grade heavy duty cable drawn through and including PVC rigid Conduit and fixed on wall /poles etc and connected to light fittings complete all as specified and directed. Note : One runs of 3 Core PVC cable 2.5 sqmm & one run of PVC conduit will be considered as one unit. |
| 31 | S&F LT Street Light Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 600 x 450 x 250 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under : Incoming :- (a) MCCB 4 Pole, Micro processor release, breaking capacity 36 kA at 415V, 50Hz, 63 Amp 415V (Make : L & T Cat No CM92153OOOOX1 or equivalent in Legrand/Schneider) - 01 No. (b) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- (a) 3 pole street light power contactor with astronomical timer relay 24 hrs, fuses, complete suitable for 32A capacity - 01 No including necessary O/L, SPP & S/C protection relay complete for street light connection . (b) Angle iron base frame of required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50 x 50 x 6 mm thick angle iron duly painted - 01 No. |
| 32 | M&L GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia),medium grade, 1.20 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying two coats of aluminium paint over a coat of primer complete all as specified and as directed. |
| 33 | Supply and laying of DWC pipe inner dia 120 mm and outer dia 103 mm comfirming to IS 16205 for protection of LT UG cable of size upto 25 sqmm all complete all as specified and directed. |
| 34 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 35 | Supply and Install centrifugal pump set split casing of discharge capacity 360 cum per hr at 60 mtr head suitable for 1480 RPM having CI impeller SS 410 shaft with pump efficiency 78 % directly coupled with 150 HP /110 KW with 1480 RPM ,50 Hz squirrel cage induction motor 415 volt complete all as specified and directed. |
| 36 | Supply and Install Star delta starter suitable for capacity 150 HP pump motor with digital meter along with 16 guage box complete all as specified and directed. |
| 37 | Supply and fixing of copper wire of size 90 sqmm 3 core with color code RYB suitable for connecting capacity 150 HP pump motor complete all as specified and directed. |
| 38 | M&L earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connected with and including GI strip of size 32x 6 MM by means of bolts and nuts check nut and washer of galvanized iron with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion including taking down old unsv earthing, complete all as specified and directed. Note :- (i) RCC pit cover shall be cast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lie if CI cover and the rate includes in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate. (iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate. |
| 39 | Supply and Install Electric driven pump of capacity 50 HP ,horizontal end suction , centrifugal type,CI casing and bronze impeller stainless steel shaft, suitable for delivering 2640 LPM , 90 meter head and 2900 RPM complete all as specified and as directed. Make: Kirloskar/KSB/CG/CRI |
| 40 | Supply and fixing Star delta Starter fully automatic suitable for 50 HP motor ,415 V AC complete all as specified and as direected. |
| 41 | Supply and fixing NRV 100 mm dia cast iron complete all as specified and as direected. |
| 42 | Supply and fixing Sluice valve 150 mm cast iron complete all as specified and as direected. |
| 43 | S&F for GI tubes, medium grade 150mm dia with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender