Housing Urban and Rular Development Local Bodies Closing in 25 days TDR #58429924

Tender For Construction Of Entry Gate, Installation Of Statue And Beautification Work On The Approach From Nh-09 Towards Diamond Flyover

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
2.84 Crore
Estimated cost
Bid Submission
03 Dec 2026
25 days left
EMD
5.69 Lakhs
Bank guarantee accepted
Document Fee
13098
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Entry Gate, Installation Of Statue And Beautification Work On The Approach From Nh-09 Towards Diamond Flyover

BOQ

Name of Work:- CONSTRUCTION OF ENTRY GATE, INSTALLATION OF STATUE AND BEAUTIFICATION WORK ON THE APPROACH FROM NH-09 TOWARDS DIAMOND FLYOVER
Sl. No. Item Description
1GATE COMPLEXEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer- incharge. All kinds of soil DSR 2023/2.6.1(a) Excavation up to 1.5 mtr.
2(b)Excavation 1.5 mtr. To 3.0 mt.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 2023/4.1.8
4Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). As in item no. 3 above but for slabs (Using1:1.5:3 Mix concrete) DSR 2023/5.3
5As in item 3 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)Up to Plinth level DSR 2023/5.1.2
6(i) Above Plinth level DSR 2023/5.3
7As in item 3 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.Up to Plinth level DSR 2023/5.1.2
8(i) Above Plinth level DSR 2023/5.2.2
9As in item 3 above but in R.C.C. Raft foundation and footing with approved stone ballast.(Using 1:1.5:3 Mix concrete) DSR 2023/5.1.2
10Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 2023/6.1.2
11Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 2023/6.4.2
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 2023/5.22.6
13Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - Exposed face fine dressed with rough backing.30 mm thick DSR 2023/8.14.1.5
14Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.DSR 2023/8.15
15Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar'1 :2 (1cement : 2 coarse sand), including making the necessary chases.DSR 2023/8.16
16Making cornice/moulding below railing & walls including labour, material etc. complete as per Design in direction of engineer in charge.,Scaffolding works extra. MR
17Providing and fixing of stone Arch including labour & material etc complete as per direction of the Engineer-in-charge.MR
18Providing & fixing of Stone jali .MR
19Providing & fixing of C.N.C. Jali MR
20Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. For mass concrete. DSR 2023/5.9.1
21(b) Columns, Pillars, Piers, Abutments, Posts and Struts .DSR 2023/5.9.6
22(c)Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. DSR 2023/5.9.20
23(d) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick DSR 2023/5.9.21
24(a) Providing & fixing of Red sand stone Chhatri including labour, material etc. complete as per Design in direction of engineer in charge. Large chhatri MR
25(b) Small chhatri MR
26Providing & fixing of Kalash on stone Chhatri.MR
27Supply & fixing of signage/logo MR
28INTER LOCKING PAVEMENTProviding and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge DSR 2023/16.68
29EXTERNAL ELECTRIFICATIONSupply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. NDSR (MR)External Feeder PillarINCOMING1No. Of 63 Amps FP MCCB of 25KA breaking capacityMetering :1 Set of CT's one of 63/ 5Amp ratio for Multifunction MeterOne (1) Set of Phase Indication Lamp.BUS BAR1 Set of 100 Amps TPN Aluminium Bus BarsOUTCOMING32 Amps FP MCCB of 25KA - 4 No(3 OUTGOING+SPARE)Panel described as above
30SUBHEAD: - II - EARTHINGEarthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required DSR E&M 2025 5.2
31Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) asrequired. DSR E&M 2025 5.4
32Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) DSR E&M 2025 5.9
33Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. DSR E&M 2025 5.12
34SUB-HEAD -III : L.T. CABLESLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required DSRE&M 2025 10.5.1 Up to 35 sq.mm.
35Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment NDSR4 x 16 sq.mm
36(i) 3 x 6 sq.mm,
37Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. DSR E&M 2025 11.1.22 X 10 sq. mm (19mm)
38(i) 4 X 16 sq. mm (28mm) SI 11.1.33
39Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required90 mm dia (OD-90 mm & ID-76 mm nominal) DSR E&M 2025 15.16.2
40SUBHEAD - III :MiscellaneousConstructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : CIVIL DSR 18.34With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 SI 18.34.1
41SUBHEAD - IV: EXTERNAL LIGHTINGSupply, Installation, Testing and Commissioning of LED RGB/RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270V AC, 50Hz with power factor>0.9. Fixture shall be suitable to operate at an ambient temperature range of-10°C to +50°C and shall be IP65 and IK06 rated. Life times hall beat least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322) and shall be complete with all necessary accessories required for proper working of fixture including weatherproof connection cables, water proof connectors etc. as required. DSR FACADE LIGHTING 145W /40W
42Supply and fixing of LED Burial light fitting having die cast aluminium body anddiffuser with driver set suitable for 6 watt to 10 watt. Confirming to IP 68 and above protection complete in all respect. NDSR
43Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. DSR E&M 2025 2.10Double pole
44Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, NDSR
45Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. DSR E&M 2025 7.41 output per phase and suitable for single phase supply
46Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required 32mm dia DSR E&M 2025 12.6
47HORTICULTURESupplying and stacking of sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment) (DSR-2.3)
48Carrigae of sludge upto 5 K.M. (DSR-1.1.3)
49Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S.designation 4.75 mm (DSR-2.4.3)
50Carrigae of manure upto 5 K.M. (DSR-1.1.3)
51Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.(DSR-2.9)
52Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manureor/and good earth to be paid separately). (DSR-2.8)
53Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). (DSR-2.14.1)Holes 1.2 m dia and 1.2 m deep
54Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.(DSR-7.63)
55Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as perdirection of the officer-in-charge.(DSR-7.65)
56Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf.(DSR-2.10.2)
57Sculpture WorksEarth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches (not exceeding 1.5 m width or 10 sqm on plan), incl. dressing of sides & ramming of bottoms, all lift, getting out & disposal of surplus soil within 50 m lead — all kinds of soil. DSR SI 2.8.1
58Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in 20 cm layers, incl. ramming & watering, lead up to 50 m, all lift. (Return filling in 300 mm annular cover around foundation) DSR SI 2.25
59Providing & laying in position reinforced cement concrete 1:1.5:3 (M20 nominal mix; 20 mm graded stone aggregate), excluding centering, shuttering, finishing & reinforcement — all work up to plinth level. DSR SI 5.1.2
60Reinforced cement concrete 1:1.5:3 in walls, columns, pillars, piers, posts etc. above plinth level, excluding centering, shuttering, finishing & reinforcement. DSR SI 5.2.2
61Steel reinforcement for RCC work incl. straightening, cutting, bending, placing in position & binding — Thermo-Mechanically Treated (TMT) bars Fe-500D or more DSR SI 5.22.6
62Centering & shuttering incl. strutting, propping & removal of form — foundations, footings, bases of columns etc.DSR SI 5.9.1
63Extra for shuttering in circular work (20% of item 5.9.1) — foundation DSR SI 5.9.14
64Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc.DSR SI 5.9.2
65Extra for shuttering in circular work (20% of item 5.9.2) — kerb DSR SI 5.9.14
66Centering & shuttering — columns, pillars, piers, posts etc. (Curved faces of pedestal drums) DSR SI 5.9.6
67Extra for shuttering in circular work (20% of item 5.9.6) — pedestal DSR SI 5.9.14
68Brick work with common burnt clay F.P.S. (non-modular) bricks, class designation 7.5, in superstructure above plinth level, all shapes & sizes, in cement mortar 1:4.DSR SI 6.4.1
69Providing & fixing 18 mm thick gang saw cut, mirror polished, premoulded & prepolished machine-cut granite for facias & similar locations, laid over 20 mm base CM 1:4, joints with white cement, epoxy touch-ups, moulding & polishing of edges — Granite black / Cherry-Ruby red, slab area over 0.50 sqm. (Pedestal front 7.65 sqm + top 2.60 sqm) DSR SI 8.2.2.2
70Steel work in built-up tubular (round/square/rectangular hollow tubes) work incl. cutting, hoisting, fixing in position & applying priming coat of approved steel primer, incl. welding & bolting complete — Electric resistance / induction butt-welded tubes. DSR SI 10.16.3
71Painting with synthetic enamel paint of approved brand & required colour, two or more coats on new work over an undercoat of suitable shade (MS tube grill incl. added vertical poles — measured on enclosing area 7.66 m x 0.762 m = 5.84 sqm + 10% = 6.42 sqm) DSR SI 13.62.1
72PART B — SPECIALISED / NON-DSR ITEMS — Cost Index NOT applicable)SUPPLY AND FIXING — Stainless steel sculpture 8 ft (H) x 6 ft (W) complete with installation & landscaping,Quotation
73SUPPLY AND FIXING OF LIGHTING Quotation
74Supply and fixing jali with logo in gate (grill) Quotation
75Supply and fixing 1 m long LED Bollard Light 25 to 45 Watt with foundation Quotation
76HIGH MAST LIGHTSupply and Fixing of 100W-120W Decorative tear drop Luminaire with CCT 4000K/5700K,Operating Voltage range 140 - 270 V, CE / BIS Certified,IK09, IP 66 Luminaire. Spun aluminium top cover Ø Min. 536-634 mm max, with double Aluminium Casting crown attachment added for aesthetics, Gravity die cast aluminium (LM6 Grade) Suitable for pole arm mounting with ID of Ø41 mm with 3 nos. SS Hex bolt M8X25 screws. Spun aluminium top cover have undergone Acid treatment & pure polyester powder coating.Convex type acrylic diffuser. Lamp fixedposition.Fixture Height should be 617mm, This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), (L70 B50) Lifespan of the luminaire > 50,000 hours . Operating ambient temperature range is from +50°C. Driver efficiency >85%, power factor >0.9, THD <10%,CRI-70, Surge protection Min 10KV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13. Make Unilamp/WIPRO/Klite -KL- 6799/Bega. The manufacturer should have inhouse manufacturing facility and inhouse oniophotometer to check the photometry of the Luminaire. The installation will be as per the direction provided by the manufacturer and Engineer-in-charge. MR
77Supply and Fixing of 9mtr Decorative pole made of galvanised mild steel pipe fitted with cast aluminium Embellishments duly polyurethane paint Coated with CNC on bottom of GMP and bracket.Bottom dia- 200x200x1500mm Top-88.9x7500mm Base Plate- 300x300x16mm PCD-300mm with Single arm bracket in 1:3:6 RCC foundation bolt including the cost of foundation excavation and back filling and T & P complete in all respect. Make:kaslac/K-lite/Polux Engineers/Havells Lighting/ Bajaj/ Trading etc.PSR-2025
78Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering Set. 242 pipe etc. with charcoal/ coke and salt as required.(7658*0.838=6417.404) DSR-2025/5.2
79Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (755*0.838=632.69) DSR 2025/5.11
80Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. withcharcoal/coke and salt as required.(15004*0.838=1257.352) DSR 2025/5.6
81Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm), (1024*0.838=858.112)DSR 2025/5.8
82Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Size: 25 sq.mm 3-1/2 core UP PWD SOR-2018/501(i)
83Supply and fixing 40 A TPN capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. UP PWD SOR-2018/1423
84Supplying & Laying of 10 Sqmm X 2 Core PVC sheathed unarmoured cable 1.1 KV grade XLPE insulated and FRLS PVC sheathed UNARMOURED cable conforming to relevant IS.etc.UP PWD SOR-2018/807(f)
85Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. CAT-AAA SOR 2018-1443
86Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. (Pwd Sor No 652) complete in all respect. Make: - Wipro/Philips/Crompton SOR 2018-652
87Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. SOR 2018-625D
88Supply & fixing of factory wired integral LED Flood Light luminaire with die cast aluminum housing built with driver set suitable for 200 watts confirming to IP 66 protection in all respect. PWD SI No 1455. Make:- Wipro/Philips/LT/Trilux SOR 2018-1455
89Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 40 Amp TPN SOR 2018-807 (F)(ii)
90Supply and fixing of single unit LED aviation obstruction light complete with transformer and LED spiral etc complete in all respect. CAT AAA SOR 2018-409
91Supply & fixing of Radium Sign board with Lettering & numbering of poles with photography of each poles(2 Fit x1.5 fit) MR
9233 KV LINE2 pole structure Supply, erection and commissioning of 2-pole structure for terminating 11 KV O.H. supply from supply company as per specifications and drawing. The 2-pole structure shall comprise of:-a) MS tubular galvanised swaged pole 11 mtrs high (410SP 55) (as per latest relevant BS standard)or as per Indian std., in cement concrete foundation 1:3:6 (1 cement : 3 coarse sand : 6 graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint -2 Nos.b) Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc of different sizes for cross arms, bracings, supports etc. for pole GODO etc. including anticlimbing barbed wires (conforming to BS Standard) having 4 points barbs spaced 75 ±12mm apart. All steel structure shall be given 2 coats of red oxide primer and 2 finishing coats of aluminium paint as required as per drawings and direction of Engineer-in-charge -Lot c) Supply, installation, testing and commissioning of 11 KV class disc/pin/support insulators complete with clamps and fixing hard disc/pin/support insulators complete with clamps and fixing hard wares etc. complete as required as per drawings and direction of Engineer-in-charge -Lot d) Supply, installation, testing and commissioning of 11 KV station class thyrite type lightning arrestors complete with mounting arrangement (on all phases) -1 Set e) Supply, installation, testing and commissioning of drop out -lock out (DOLO) fuse, gang operating device (Air Break Switch) with pad locking arrangement (operating rod to be supported properly), complete with operating handle and locking arrangement -1 Set f) Supply, installation, testing and commissioning of GI stay set complete with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles, stay clamps, 7/4.00 mm dia GI stay wire, turn buckle (20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling -1 Sets 2-pole structure as described above. MR
93Supplying and erection of 33KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.(928x0.838=777.65) DSR-2025/14.23
94Supplying and erection of 33 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.(13122x0.838=2616.24) DSR-2025/14.24
95Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of ze * 45cm * 45cm * 7.5mm thick, thimble, stay clamps, turn buckle 20mm * 600mm ), 7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation and excavation including required. (6144x0.838=5146.996) ) DSR-2025/14.14
96Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.3.0 C x 300 sqmm Aluminium conductor Rate Analysis Based on Stock issue Register S. No. 16
97Supply of 3CX300 sqmm, 33 kV XLPE cable Outdoor Jointing Kit complete in all respects as per direction of E/I. UPPCL S.I.R.(2025-26) SN-43
98Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. 160 mm dia (CD-160 mm & ID-135 mm nominal) ( 385x0.838=322.63) DSR-2025/15.15.4
99Earthing with Cu. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR-2025/5.6[15004x0.838=12573.352)]
100Dismantling of overhead lines comprising of copper/aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required.(111x0.838=93.018) DSR-2025/13.40 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58429924
AUTHORITY Local Bodies
TENDER VALUE 2.84 Crore
LAST DATE 03-12-2026
Authority
Authority Name Ghaziabad Development Authority
Work Description Tender for Construction Of Entry Gate, Installation Of Statue And Beautification Work On The Approach From Nh-09 Towards Diamond Flyover
Basic Detail
Tender No 701/4/PA-T/2026-27 Dt. 05.11.2026 (S.no-5)
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 06 Nov 2026
Submission Date 03 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value 2.84 Crore
Tender Fee 13098
EMD 5.69 Lakhs
Exemption Not Available
Document List
701_5.pdf
BOQ_2287142.xls
f47bba85-0abe-4429-9b10-d88c634e75f0.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
pdf

701_5.pdf

xls

BOQ_2287142.xls

html

f47bba85-0abe-4429-9b10-d88c634e75f0.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender