Tender For Provn Of Ac Points In Md Accn At Vsn Nagpur (Phase-Iii)
Tender Value
42.53 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
20 days left
EMD
85100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provn Of Ac Points In Md Accn At Vsn Nagpur (Phase-Iii)
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Fixing MCB TPN 100 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. all complete as specified and directed. |
| 2 | Taking down old unserviceable and Material and labour for laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 4 Core all complete as specified and directed. |
| 3 | All as per item No 2 above but of size 50 sqmm 3.5 Core all complete as specified and directed. |
| 4 | All as per item No 2 above but of size 150 sqmm 3.5 Core all complete as specified and directed. |
| 5 | All as per item No 2 above but of size 120 sqmm 3.5 Core all complete as specified and directed. |
| 6 | All as per item No 2 above but of size 185 sqmm 3.5 Core all complete as specified and directed. |
| 7 | All as per item No 2 above butr of size 240 sqmm 3.5 Core all complete as specified and directed. |
| 8 | Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe ( where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed. |
| 9 | Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point all complete as specified and directed. |
| 10 | Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed. |
| 11 | Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of HDPE pipe 40 to 100 mm bore and making good both ends all specified and directed |
| 12 | Material & Labour for sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed. |
| 13 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 2, flat size 300mmx 180mm x 40mm all complete as specified and directed. |
| 14 | Materian & Labour for demolition of Hardstanding road & concrete in floor for laying of LT cable and making good the disturbed surfaces of floor by applying cement plaster matching with the existing surfaces complete all as directed. |
| 15 | Material & Labour for PCC 1:3:6 type C-2 (using 40 mm gradded aggregate) for foundation, filling and mass concrete etc complete all as specified and directed . |
| 16 | Material & Labour for sub main wiring (concealed/surface) complete with two single core 4 Sqmm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLSH PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note :- (i) 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit. (ii)The disturbed surfaces of wall for concealing box/wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for the same shall be deemed to include the cost of making good. |
| 17 | Supply and fixing power unit with 20A SP MCB alongwith 20 A Plug for AC upto 2 ton, 3 module, 240 volts all as specified and directed. |
| 18 | Supply & Fixing MCB SP 6-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. all complete as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender