Tender For Conversion Of Modular Operation Theatre At Seethalakshmi Urban Primary Health Centre In Ward No. 70 Of Central Zone. Roc No.5038/2026/Md5

Issued by Local Bodies · Coimbatore, Tamil Nadu
Tender Value
46.20 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
16 days left
EMD
46200
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Conversion Of Modular Operation Theatre At Seethalakshmi Urban Primary Health Centre In Ward No. 70 Of Central Zone. Roc No.5038/2026/Md5

BOQ

Name of Work:- Conversion of Modular Operation Theatre at Seethalakshmi Urban Primary Health Centre in Ward No. 70 of Central Zone. ROC No.5038/2026/MD5
Sl. No. Item Description
1Clean removal of Cement plaster from Ceiling as per the direction of departmental officers etc., complete
2Dismantling the existing damaged Brick Work as per the instruction of Departmental officers etc., complete
3Dismantling the existing damaged Vitrified tiles, Ceramic Tile and Dadooing Wall Tile as per the instruction of Departmental officers etc., complete
4Dismantling the existing damaged Plain Cement Concrete as per the instruction of Departmental officers etc., complete
5Plain Cement concrete 1:4:8 (one cement, foursand and eight aggregate) using 40mm hardbroken granite stone jelly for foundationincluding dewatering if found necessary andlaid in layers of not more than 15 cm thickand compacted etc.,complete complying witstandard specification.
6European Water Closet (Colour) with 'P' or 'S' Trap with Double Flapped seat and seat cover with Brass Highes and 10 litre capacity PVC low level flusing tank with all internal fittings
7Plain Cement concrete 1:2:4 (one cement, two sand and Four aggregate) using 20mm hard broken granite stone jelly for foundation including dewatering if found necessary andlaid in layers of not more than 15 cm thickand compacted etc.,complete
8Flooring finishing with first quality Design Ceramic tiles of all colours of size 305cm X 305cm X 6mm laid in cement mortar 1:3 mix to 20mm thick and painting with white cement using 0.30 kg/1m2 including finishing the jointing and painting flush with tiles surface etc., complete - 10 m2
9Dadooing walls with ceramic tiles of sizes 300mm X 450mm X 8mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. (Sl.No.360f)
10Supply and fixing of Solid PVC door shutter using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fix in position including necessary furniture and fittings. The cover all size of top rail, Lock rail and bottom rail shall be 70mm x 45mm, with suitable rebate for housing the shutter.
11Supplying, fabricating and placing in position TMT/CTD rods for all RCC works including cost of steel and binding wire also in all floors complete complying with standard specification
12Reinforced Cement concrete 1:1.5:3 (one cement, one and a half sand and three aggregate) using 20mm hard broken granite stone jelly for all RCC items of work excluding centering, shuttering, and cost of reinforcement grill but including curing finishing, vibrator charges etc., complete and also including fixing fan clamps and fixtures in RCC works wherever necessary as directed by departmental officer etc., complete.
13Plastering the exposed surface of RCC works in cement mortar 1:3 mix 12mm thick with standard specifications.
14Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm (8 3/4\\" x 41/4\\" x 23/4\\") including cost of materials and labour charges etc., as per standard specification - 1m3
15PLASTERING with cement mortar 1:5(one cement and five sand by volume) 12mm thick for all internal/external surfaces like super structure, rainwater, ducts, elevation in all floors complying with standard specifications.
16Paving the floor with Vitrified Floor Tiles of size 60 X 60cm of approved brand and colour Marbonite tiles in all floors base layer of cement mortar 1:3 (one cement and three sand) 20mm thick using first quality Marbonite tiles of size 60 X 60cm and point with colour cement neatly and fixed in position so as to make perfectly smooth and to alignment etc., complete complying with standard specification
17UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
18Supply and providing false ceiling arrangements using 12.5 mm tk tapered edge Gypsm Board False ceiling confirming to IS 2095 including providing and fixing of frame work made up of special sections power pressed from MS Sheet and Galvanised Zinc Coating 600 micron as per IS 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm tk.with flanges of 12 mm and 37 mm providing and fixing at all height false ceiling of at 1200 mm c/c on flanges to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the hanger of 25 mm x 25 mm 5mm of required length and other end of angle hanger being fixed with nuts and bolts to G.I. Channels 45 mm x 15 mm x 0.90 mm running at the rate of 1200 mm c/c to which the ceiling section 0.5 mm tk. bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 at 450 mm c/c shall be fixed in a direction perpendicular to G.I Channel with connected clips made out of 2.64 mm dia x 230 mm long G.I.Wire at every junction including fixing the gypsm board with ceiling section and perimeter channels5 mm tk. 27 mm high having flanges of 20 mm and 30 mm long,theperimeter of ceiling fixed to wall /partitions with the help of rawl plugs at 450 mm c/c with 25 mm long drive -all screws at 230 mm intervals including jointing and fixing to a flush finish of tapered and square edges of the Gupsum Board with recommented filler,paper tapes,Finisher and twp coats of primer suitable for Gypsum Board as per manufactures specification and also including the cost of making openings for light fitting ,Grills Diffusers,cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of th departmental officers .(excluding cost of paintnig)
19Stainless Steel Wall Cladding for Operation TheatreProviding and fixing factory-fabricated Stainless Steel SS 304 wall cladding/panel system for Operation Theatre, comprising minimum 1.2 mm thick SS 304 grade stainless steel sheets, satin/matte finish, mounted over a suitable galvanized steel supporting sub-frame and backed with fire-resistant/moisture-resistant board or approved insulation, including all necessary framing, stiffeners, trims, concealed fasteners, joints, corner panels, sealant/gaskets and accessories. The system shall provide a smooth, non-porous, hygienic, corrosion-resistant and easy-to-clean surface, with sealed/hermetically closed joints, rounded/smooth internal corners without sharp edges, suitable for regular cleaning, disinfection and hospital operating-theatre conditions, including provision for flush mounting of medical equipment, electrical points, medical gas outlets and other services, complete in all respects as per the specifications, drawings and instructions of the Engineer-in-Charge.
20Stainless Steel False Ceiling for Operation TheatreProviding and fixing of Stainless Steel SS 304 false ceiling system for Operation Theatre, comprising minimum 1.2 mm thick stainless steel panels of approved size and finish, including GI/SS supporting grid, suspension system, hangers, perimeter channels, stiffeners, trims, edge profiles, concealed fasteners, necessary cut-outs and openings for light fittings, air-conditioning diffusers, medical gas services and other MEP services, with properly sealed and hygienic joints. The ceiling shall have a smooth, non-porous, corrosion-resistant and easy-to-clean surface, suitable for operation theatre conditions, including all necessary materials, accessories, labour, tools and equipment, complete in all respects as per the specifications, drawings and instructions of the Engineer-in-Charge.
21Providing Cornice Work for Gyp Board False Ceiling as per the direction of th departmental officers
22Providing and fixing powder-coated aluminium office partition with 50 mm × 25 mm finished aluminium sections of Jindal standard, including 50 mm × 40 mm aluminium door sections with beading, 8-tank chemical pretreatment, epoxy polyester powder coating of 40–60 microns thickness, aluminium beading, modular fittings, necessary accessories, installation and all labour charges, complete in all respects
23Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricatedfrom un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm.The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steelreinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. Thesash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazedwith 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded45 degrees. The window should be designed such that the water drainage does not pass through the reinforcementchamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plugand driving ms electroplated screws into plug.
24Providing and fixing of 1.2mm thick Lead Lining Door for X-Ray Rooms, Scanning Rooms with Mild Steel Door Frames 105mm x 57mm X 18 G and 12 G x 50mm Shutter made of GI with PWG finish and honey wool insulationswith SS 101mm x 75mm x 3mm SS 304 Ball Bearings Butt Hinges, Mortice Sash Lock ML 100A, 50mm BS, 85mm centre, CL 207 : Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make), Heavy Duty Door Closer, Frames fixed wih walls using Mortice Sash Lock ML 100A, 50mm BS, 85mm centre CL207: Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make) all neccesary accessories and fittings as per the required and as per the approval for the Department Officer
25Providing and fixing of Stainless Steel SS 304 grade sink of size 1200 mm x 550 mm x 180 mm for Operation Theatre, fabricated from high-quality stainless steel sheet with smooth, non-porous, hygienic and corrosion-resistant finish, including sink bowl, drain outlet, waste coupling, overflow arrangement, suitable brackets/supporting frame, sealant, necessary cut-outs and plumbing connections, complete with all required fittings, accessories, labour and installation, as per the specifications, drawings and instructions of the Engineer-in-Charge.
26Wiring with 2x1.5sq.mm (22/3.0) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessorie in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A switch with continous earth wire connection of SWGTC wire for making good of the concealed portion with suitable colour for PVC Concealed light/Fan Point (For electronic regulator) (5 Points per coil)
27Wiring with 2x1.5sq.mm (22/3.0) PVC insulated unsheathed single core unsheathed copper Conductorcable of 1100V grade in suitableheavy gauge MS conduit pipeon wall and celling with M.S accessories inflush with wall with 150mm x 100mm x 75mm MS swithbox with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuos earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point.
28Wiring with 2x4 sqmm (56/3.0) PVC insulated SC unsheathed cu. Conductor cable of 1100V grade in suitable heavy gauge MS conduit piped on wall and celling with M.S accessories inflush with wall with 150mm x 100mm x 75mm MS switch boxconcealed type with 3mm thick hylum sheet cover for 15A 3pin non interlocking CS plug with continuos earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed power plug point.
29Supply and run of 2 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour.(SD-56)
30Supply and fixing of 1200 mm (48”) AC ceiling fan complete with energy efficient fan of 28 W Regulator with 0.3 m down rod on existing clamp approved brand and good quality as per the departmental officers instruction etc.,Complete (SD 108)
31Supply and fixing of 450mm (18\\") sweep (light duty) AC Exhaust fan complete without provision of hole to wall (SD 119)
32Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting
33Supply & Installation of 1.5 TR Split Type AC Unit Inverter with Copper coi l(AIR-CONDITIONER ) etc, complete as per standard specifications
34Supply and Fixing of Stabilizer for Air Conditioner of approved brand including cost of material with installation charge etc
35Supply, installation, testing and commissioning of 2 TR, 4-Way Cassette Type Inverter Air Conditioner, ceiling-mounted indoor unit with outdoor condensing unit, suitable for 230 V, 50 Hz, single-phase AC supply, with inverter compressor, R-32/R-410A refrigerant, 4-way air flow, wireless remote controller, built-in drain pump, copper refrigerant piping with suitable insulation, drain piping, necessary electrical connections and accessories, including all materials, labour, testing and commissioning, complete as directed by the Engineer-in-Charge.
36Supply and fixing of 22 watts LED Tube Light Fittings complete with copper choke and condensor with TW round blocks on wall or ceiling with LED tube with PVC unsheathed copper leads from terminals to the fitting including all cost etc complete.
37Supply and fixing of 65 mm dia GI pipe (Class'B') 4 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting and construction of masonary pedestal with MS box of 30cm x 20cm x 10cm with angle iron frame work with door and lock and key arrangements with supply and fixing of 60W LED street light fitting with bulb and with supply and fixing of 1No.16A fuse unit (500V) and 5A SP switch inside the MS box with PVC unsheathed FRLS leads and painting of suitable colour
38Supply and fixing of Wall Mounted Air Circulator - Wall 24\\" Fan with Double ball-bearing 900 oscillation Sturdy close-mesh guard beautifull design and Powerful heavy-duty motor . etc, complete as per standard specifications
39Painting with First Quality Emulsion paint two coats over a priming coat including cleaning, scrapping, removal of dust and necessary plaster of paris putty works wherever required etc., complete.
40Painting with first quality emulsion paint two coats including thorough cleaning, scrapping, removal of dust and including necessary plaster of paris putty works wherever required etc., completed
41Painting with enamel paint two coats over base coat for new iron works using good quality and approved colour etc. completed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58429303
AUTHORITY Local Bodies
TENDER VALUE 46.20 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Conversion Of Modular Operation Theatre At Seethalakshmi Urban Primary Health Centre In Ward No. 70 Of Central Zone. Roc No.5038/2026/Md5
Basic Detail
Tender No E87/2026 TwoCover
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 06 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 46.20 Lakhs
Tender Fee Ref. Documents
EMD 46200
Exemption Not Available
Document List
BOQ_868548.xls
Building.pdf
d3466401-8f47-4e5d-90bd-498c296f1d4f.html
ITB.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_868548.xls

pdf

Building.pdf

html

d3466401-8f47-4e5d-90bd-498c296f1d4f.html

pdf

ITB.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender