Housing Urban and Rular Development Government Departments Closing in 4 days TDR #58428836

Tender For General-Providing Ups At Buildings Sub Division Nedumangadu Nedumangadu.-Sitc Of Ups-General Electrical Work

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Nov 2026
4 days left
EMD
5502
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Providing Ups At Buildings Sub Division Nedumangadu Nedumangadu.-Sitc Of Ups-General Electrical Work

BOQ

Name of Work:- GENERAL-Providing UPS at Buildings Sub Division Nedumangadu Nedumangadu.-SITC of UPS-General Electrical Work
Sl. No. Item Description
1AMC-2021-2022
2OD187945/2026-2027:Supply, installation, and commissioning of 2kva UPS Single phase in and out. with indoor (IP20) Input pf >0.99, double conversion technology with input voltage range 176-300 @ full load, 50Hz Single Phase, THD of input current should be < 3% at full linear load. output 230V, 50Hz Single phase, It shall be 100% generator compatible, with Efficiency > 92% and output power factor unity ( 2kVA=2kW), Eco mode Efficiency 97% and including all accessories etc as required. The acoustic noise at 1m of the system should be <55dB.The systemshall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS, and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shallbe with automatic bypass builtin. The system shall have IGBT rectifier and inverter. warranty 3 years for UPS and batteries. The system shall have a battery back up using 5400 VAH C10 tubular battery system (6 numbers 12V 75AH or equivalent) along with battery stand (UPS make - Numeric/APC/Vertiv - Emerson/Hykon/Delta/Eaton or equivalent) (Battery - Exide EL/Amaron)
31.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
41.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
51.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
61.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
71.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
81.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
91.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
101.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
111.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
121.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
131.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
141.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1590.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
1690.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
171.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
181.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
192.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
202.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
212.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
222.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
232.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
242.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
252.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58428836
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 12-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Providing Ups At Buildings Sub Division Nedumangadu Nedumangadu.-Sitc Of Ups-General Electrical Work
Basic Detail
Tender No PWD/BLDG/TR/21299/2025
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 06 Nov 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 555
EMD 5502
Exemption Not Available
Document List
affi.pdf
agree.pdf
BOQ_1512494.xls
c2394559-12a2-443b-a657-5e19a5393e7d.html
epayment.pdf
form.pdf
IP.pdf
make.pdf
Tendernotice_1.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

affi.pdf

pdf

agree.pdf

xls

BOQ_1512494.xls

html

c2394559-12a2-443b-a657-5e19a5393e7d.html

pdf

epayment.pdf

pdf

form.pdf

pdf

IP.pdf

pdf

make.pdf

pdf

Tendernotice_1.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender