Tender For Construction Of Girls Toilet At Batabari Cha Bagan Ssk Within Matiali Batabari-I G.P Under Matiali Block
Tender Value
4.70 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
12 days left
EMD
9404
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of Girls Toilet At Batabari Cha Bagan Ssk Within Matiali Batabari-I G.P Under Matiali Block
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. In layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 and for all lift |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level:a) 1:3:6 (1 Cement: 3 coarse sand (zone- III) derived from natural sources: 6 graded stone aggregate 20mm nominal sizederived from natural sources) |
| 5 | b) 1:2:4 (1 cement: 2 coarses and (zone-III) derived from natural sources: 4 graded stone aggregate 20mm nominal sizederived from natural sources) |
| 6 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., upto floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20mm nominal sizederived from natural sources) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 9 | b) Suspended floors, roofs, landings, balconies and access platform |
| 10 | Providing and laying damp-proofcourse40 mm thick with cement concrete 1:2:4(1 cement :2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1cement :6 coarse sand) |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) ricks of class designation 7.5 in superstructure above plinth level upto floor V levelCement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | Tile brick masonry work 5cm thick with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth and upto floor five level. |
| 14 | Cement Plaster (In Fine sand)20mm cement plaster of mix:1:6 (1 cement : 6 fine sand) |
| 15 | 15mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement : 4 fine sand) |
| 16 | 12mm cement plaster of mix :1:4 (1 cement : 4 fine sand) |
| 17 | Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic water proofing polymers on interior wall plaster surface in three coats @14.35kg/10sqm. One coat of self priming of cementatious water proofing polymer (dilution with water in the ratio of 1:1) and two coats of cementatious water proofing polymer (dilution with water in the ratio of 3:1) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. |
| 18 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 19 | Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand).Dark shade pigment using ordinary cement |
| 20 | Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete. |
| 21 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of Matching shade complete. |
| 22 | Colour washing such as green, blue or buff to give an even shade:New work (two or more coats) with a base coat of white washing with lime |
| 23 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work(Two or more coat applied @1.67ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm) |
| 24 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 25 | Providing and fixing factory made panel PVC door shutter consisting o frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10mm (5mmx2) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet be adding on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.30mm thick pre laminated PVC door shutters |
| 26 | Providing precast cement concrete Jali 1:2:4 (1cement : 2 coarse sand (zone-III): 4 graded stone aggregate 6mm nominal size), reinforced with 1.6mm dia mildsteel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.25mm thick |
| 27 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 40mm dia nominal bore |
| 28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10mm gap for thermal expansion,(i) Single socketed pipes. |
| 29 | Bend 87.5 degree110mm. Dia. |
| 30 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid |
| 31 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I./ PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamp sand C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required:Single squatting plate with 5litre P.V.C. automatic flushing cistern |
| 32 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x450mm with a single15mm C.P. brass pillar tap |
| 33 | Providing and fixing brass stop cock of approved quality: 20mm nominal bore |
| 34 | Providing and fixing PTMT, push cock of approved quality and colour. 15mm nominal bore, 98mm long, weighing not less than 75gms |
| 35 | Providing and fixing brass bib cock of approved quality: 15mm nominal bore |
| 36 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):20 mm |
| 37 | 25 mm |
| 38 | Providing and fixing PTMT grating of approved quality and colour. Circular type 100mm nominal dia |
| 39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in Charge.(a)For Exposed Work PVC Pipes25mm nominal dia Pipes |
| 40 | 20mm nominal dia Pipes |
| 41 | 15mm nominal dia Pipes |
| 42 | Providing and placing on terrace(at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and the bases up port for tank. |
| 43 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion(i) Single socketed pipes.110mm diameter |
| 44 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion.Single tee with door 110x110x110 mm |
| 45 | Bend 87.5°110mm bend |
| 46 | Constructing soak pit 1.20x1.20x1.20m filled with brick bats including S.W. drain pipe 100mm diameter and 1.20m long complete as per standard design. |
| 47 | Earthwork in excavation by mechanical means(Hydraulic excavator)/ manual means in foundation trenches or drains(not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil. |
| 48 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto plinth level:1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40mm nominal size derived from natural sources) |
| 49 | Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6(1cement : 6 coarse sand) |
| 50 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4(1 cement: 2coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 51 | Brick work with common burnt lay F.P.S.(non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level in all shapes and sizes in:—Cement mortar 1:6(1 cement: 6 coarse sand) |
| 52 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3(1 cement: 1.5 coarses and (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 53 | Centering and shuttering including strutting, propping etc. and removal of form Suspended floors, roofs, landings, balconies and access platform |
| 54 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 55 | 12mm cement plaster of mix: 1:6 (1 cement: 6 fine sand) |
| 56 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @0.488 kg/sqm mixed with water proofing cement compound @0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @0.242kg/sqm mixed with water proofing cement compound @0.126kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 57 | Circular shape 450mm dia precast R.C.C. manhole cover with frame- L.D.-2.5 |
| 58 | Providing and laying non-pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement: 2 fine sand) including testing of joints etc. complete:— 150mm dia. R.C.C. pipe |
| 59 | Half brick masonry with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4(1 cement: 4 coarse sand) |
| 60 | Providing and laying non-pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement: 2 fine sand) including testing of joints etc. complete:—100mm dia. R.C.C. pipe |
| 61 | Modified base estimate using correction factor of DSR 2023 on account of GST @ 0.973 |
| 62 | Add excalation for cost index (1.19%) |
| 63 | Add for EPF @(0.35x25)=8.75% Vide OM No. DG/SOP-2022/12, dated 20/01/2023 |
| 64 | Add for EPF @(0.35x4)=1.4% Vide OM No. DG/SOP-2022/12, dated 20/01/2023 |
| 65 | Supply, Fitting and fixing of vending machine with incinerator with all required fittings and works complete (Non Scheduled Item) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender