Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58425146

Tender For Special Repair To Ac Against Ber At Kms.

Issued by Statutory Bodies & Commissions/Committees · Kota, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Nov 2026
16 days left
EMD
75000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kota → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Ac Against Ber At Kms.

BOQ

Name of Work:- SPL REPAIR TO AC AGAINST BER AT KMS.
Sl. No. Item Description
1Taking down unserviceable window/split type ACs with all accessories of any capacity from existing locationand deposited to E/M store yard complete all as specified and directed.
2Supply, installing, commissioning and testing energy efficient BEE 5 star rated heavy duty split type air conditioner with intelligent remote control, 220Volts AC, nominal capacity 2 TR, complete with copper condensing tubing designed for outside ambient temperature (summer 50 degree celcius, monsoon 32 degreecelcius), relative humidity 50% to 60 %, number of air changes 3-4 per hour, copper refrigerant piping with insulation (EP foam pipe section) upto 3 metre from indoor unit to outdoor unit with copper power cables upto 4 mtr including supply, fixing/grouting a set of best quality mounting brackets for outdoor unit, complete all as specified and directed.
3Supply, installing, commissioning and testing energy efficient BEE 5 star rated heavy duty split type air conditioner with intelligent remote control, 220Volts AC, nominal capacity 1.5 TR, complete with copper condensing tubing designed for outside ambient temperature (summer 50 degree celcius, monsoon 32 degreecelcius), relative humidity 50% to 60 %, number of air changes 3-4 per hour, copper refrigerant piping with insulation (EP foam pipe section) upto 3 metre from indoor unit to outdoor unit with copper power cables upto 4 mtr including supply, fixing/grouting a set of best quality mounting brackets for outdoor unit, complete all as specified and directed.
4S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 32 Amps 240 volts complete all as specified and as directed.
5Dismantling the unserviceable/damaged insulation and supply and fix nitrile rubber insulation of size 7/8\\" for suction and liquid refrigerant line for split type AC. (Make-A-flex,Totaline)
6S & F in repair copper tube of size 1/4\\" dia including necessary soldering, flaring and connecting the copper tube in between indoor to outdoor units of split type air conditioners and testing complete including removing the unserviceable item complete all as specified and as directed.
7S & F in repair copper tube of size 1/2\\" dia including necessary soldering, flaring and connecting the copper tube in between indoor to outdoor units of split type air conditioners and testing complete including removing the unserviceable item complete all as specified and as directed.
8S & F transparent, flexible, durable, leak resistant water drain pipe of required size for split type AC cover casing complete all as specified and directed.
9Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be measured and paid separately.)
10S & F voltage stabilizer 5 KVA single phase, 230 V, 50 Hz, capacity wall mounting type suitable to 2 TR air conditioners with low/ high voltage cut off and intelligent time delay 3 minute +/- 20 second of working voltage range input and output voltage 230V, ± 2.5%, (170 V - 270 V) and speed of correction 8 Volt per second complete all as specified and as directed.
11Cutting chases in stone, concrete block walls & slabs to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. by means of drill machine for installation of AC and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
12Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. including taking down old cable complete all as specified and as directed.
13Supply only high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal diameter 63 mm including all fittings and fixtures for insertion into horizontal boring/ floor/ wall with necessary fixing arrangements as in cable protection complete all as specified and directed.
14Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
15Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
16Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58425146
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Ac Against Ber At Kms.
Basic Detail
Tender No 9146E8
Bidding Type Tender
Location
City Kota
State Rajasthan
Key Dates
Publish Date 06 Nov 2026
Submission Date 25 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 75000
Exemption Available
Document List
Tendernotice_1.pdf
44518ebd-61d6-4f5a-ae4f-1aeedc3a5a99.html
9146Tenderdoc.pdf
BOQ_894885.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

44518ebd-61d6-4f5a-ae4f-1aeedc3a5a99.html

pdf

9146Tenderdoc.pdf

xls

BOQ_894885.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender