Tender For Procurement Of Transformer Wti/Oti For Local And Ccu Transmitter Along With Rtd For Remote Indication Of Wti & Oti For Ph-Iv, Stps, Mppgcl, Sarni
Tender Overview
Project Description
Tender for Procurement Of Transformer Wti/Oti For Local And Ccu Transmitter Along With Rtd For Remote Indication Of Wti & Oti For Ph-Iv, Stps, Mppgcl, Sarni , Wti (Winding Temperature Indicator ) , Wti For 315 Mva Bhel Make Generating Transformers Range - 30°C - 150°C , (A) Wti For 315 Mva Bhel Make Generating Transformers Range - 30°C - 150°C & Wti Ctr - Hv -456/3.2-2.8-2.3, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , (B) Wti For 315 Mva Bhel Make Generating Transformers Range - 30°C - 150°C & Wti Ctr - Lv - 12000/5A, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 20 Mva Bhel Make Unit Auxiliary Transformers Range - 30°C - 150°C Wti Lv Ctr -799.81/2.38-2.72-2.94-3.4-3.68 Oil/Wdg Temp Rise - 50/55°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 50 Mva Bhel Make Station Transformers Range - 30°C - 150°C Wti Ctr - Hv -81/2.8-2.4-2.0A, Lv1&2 - 2092/3.4-3.0-2.6A,Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 50 Mvar Areva Make Sarni Astha Reactor Range - 0°C - 150°C, Wti Ctr - 70/2 A, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 2000 & 1600 Kva Voltamp Make Ahp & Esp Transformers Range - 0°C - 150°C, Wti Ctr - 2135/5A, Oil/Wdg Temp Rise - 50/55°C, Control Switch 02 Nos. & 05 Meter Capillary Length , Wti For 800 & 750 Kva Voltamp Make Etp & Ahp Transformers Range - 0°C - 150°C, Wti Ctr - 1070/5A, Oil/Wdg Temp Rise - 50/55°C, Control Switch 02 Nos. & 05 Meter Capillary Length.. , Wti For 250 Kva Voltamp Make Raw Water Intake Transformers Range - 0°C - 150°C, Wti Ctr - 335/5A, Oil/Wdg Temp Rise - 50/55°C, Control Switch 02 Nos. & 05 Meter Capillary Length.. , Wti For 50 Mvar Ge Make Isp Reactor Range - 0°C - 150°C, Wti Ctr - 70/2.0-1.5-1.0 A, Oil/Wdg Temp Rise - 45/50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 63 Mvar Bhel Make Bus Reactor-I Range - 0°C - 150°C, Wti Ctr - 87/2.2-2.0-1.8-1.6 A, Oil/Wdg Temp Rise - 50/55°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 63 Mvar Bus Reactor-Ii Range -30°C - 150°C, Wti Ctr - 87/2.2-2.0-1.8-1.6 A, Oil/Wdg Temp Rise - 45/50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) , (A) Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) , Range - 30°C - 150°C & Wti Ctr - Hv - 455/2.5-2.0-1.5 A, Oil/Wdg Temp Rise - 40/45°C , Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , (B) Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range - 30°C - 150°C & Wti Ctr - Iv - 919/2.9-2.5-2.1 A Oil/Wdg Temp Rise - 40/45°C , Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , ( C ) Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range - 30°C - 150°C & Wti Ctr - Lv - 1837/3.0-2.7-2.4 A, Oil/Wdg Temp Rise - 40/45°C , Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length , Oti (Oil Temperature Indicator ) , Oti For Ht Transformers / Reactor Range - 20°C - 140°C 02 Micro Switches, 10 To 12 Meter Capillary Length (For Gt, St , Uat, Bus Reactor- 1 & 2) , Oti For Ht Transformers / Reactor Range - 0°C - 150°C,02 Micro Switches, 10 To 12 Meter Capillary Length. ( For Ashta Line And Isp Reactor ) , Oti For Lt Transformers Range - 0°C - 150°C, Control Switch 02 Nos & 05 Meter Capillary Length. ( For Ahp, Esp, Esp Tr Set, Etp, Rw Intake Transformers ) , Oti For Ht Transformer Range - 20°C - 140°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. ( For ,Inter Connecting Transformer (Ict) ) , Ccu With Inbuilt Power Supply / Transmitter Along With Rtd (Pt 100) For Remote Indication Of Wti & Oti , Ccu For 315 Mva Bhel Make Generating Transformers , (A) Ccu For 315 Mva Bhel Make Generating Transformers Range Wti- 30°C - 150°C & Wti Ctr - Hv -456/3.2-2.8-2.3, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C. , (B) Ccu For 315 Mva Bhel Make Generating Transformers Range Wti- 30°C - 150°C & Wti Ctr - Lv - 12000/5A, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C. , Ccu For 20 Mva Bhel Make Unit Auxiliary Transformers Wti Range - Wti- 30°C - 150°C Wti Lv Ctr --799.81/2.38-2.72-2.94-3.4-3.68, Oil/Wdg Temp Rise - 50/55°C. , Ccu For 50 Mva Bhel Make Station Transformers , (A) Ccu For 50 Mva Bhel Make Station Transformers Wti Range - Wti- 30°C - 150°C - Hv -81/2.8-2.4-2.0, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C , (B) Ccu For 50 Mva Bhel Make Station Transformers Wti Range - Wti- 30°C - 150°C - Lv1&2 - 2092/3.4-3.0-2.6A, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C. , Ccu For 50 Mvar Areva Make Sarni Astha Reactor Range - Wti - 0°C - 150°C, Wti Ctr - 70/2 A, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C. , Ccu For 50 Mvar Ge Make Isp Reactor Wti Range - Wti - 0°C - 150°C, Wti Ctr - 70/2.0-1.5-1.0 A, Oil/Wdg Temp Rise - 45/50°C. , Ccu For 63 Mvar Bhel Make Bus Reactor-I Wti Range - Wti - 0°C - 150°C, Wti Ctr - 87/2.2-2.0-1.8-1.6 A, Oil/Wdg Temp Rise - 50/55°C , Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C , (A) Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C & Wti Ctr - Hv - 455/2.5-2.0-1.5 A, Oil/Wdg Temp Rise - 40/45°C Over Ambient Of 50°C. , (B) Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C & Wti Ctr - Iv - 919/2.9-2.5-2.1 A Oil/Wdg Temp Rise - 40/45°C Over Ambient Of 50°C. , (C) Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C & Wti Ctr - Lv - 1837/3.0-2.7-2.4 A, Oil/Wdg Temp Rise - 40/45°C Over Ambient Of 50°C. , Ccu For Oti , (A) Ccu For Oti Range - Oti- 20°C - 140°C, Input From Pt100 Sensor Dual 4 - 20 Ma Dc Output Signal (For Gt, Uat, St & Ict ) , (B) Ccu For Oti Range - Oti- 0°C - 150°C, Input From Pt100 Sensor Dual 4 - 20 Ma Dc Output Signal (For Sarni- Ashta & Isp Reactor) , Transformer Protection System / Relay For 2 Mva Dry Type Transformer Having Winding Temperature Scanner 4 Channels With 4-20 Ma Dc Output Suitable For Auxiliary Supply 90-260 V Ac/Dc, Range - 0-300°C, 4Nos. Pt-100 Sensor With 5 Meters Cable Length
BOQ
| Sl. No. | Item Description |
| 1 | WTI (Winding Temperature Indicator ) |
| 2 | WTI for 315 MVA BHEL make Generating TransformersRange – 30°C - 150°C |
| 3 | (a) WTI for 315 MVA BHEL make Generating TransformersRange – 30°C - 150°C & WTI CTR – HV -456/3.2-2.8-2.3, OIL/Wdg temp Rise – 35/40°C over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 4 | (b) WTI for 315 MVA BHEL make Generating TransformersRange – 30°C - 150°C & WTI CTR – LV – 12000/5A, OIL/Wdg temp Rise – 35/40°C over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 5 | WTI for 20 MVA BHEL make Unit Auxiliary TransformersRange - 30°C - 150°C WTI LV CTR –799.81/2.38-2.72-2.94-3.4-3.68 OIL/Wdg temp Rise – 50/55°C, 04 micro switches, 10 to 12 meter capillary length. |
| 6 | WTI for 50 MVA BHEL make Station TransformersRange - 30°C - 150°C WTI CTR – HV -81/2.8-2.4-2.0A, LV1&2 – 2092/3.4-3.0-2.6A,OIL/Wdg temp Rise – 50/55°C over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 7 | WTI for 50 MVAR Areva make Sarni Astha ReactorRange – 0°C - 150°C, WTI CTR – 70/2 A, OIL/Wdg temp Rise – 50/55°C over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 8 | WTI for 2000 & 1600 KVA Voltamp Make AHP & ESP TransformersRange – 0°C - 150°C, WTI CTR – 2135/5A, OIL/Wdg temp Rise – 50/55°C, Control Switch 02 Nos. & 05 meter capillary length |
| 9 | WTI for 800 & 750 KVA Voltamp Make ETP & AHP TransformersRange – 0°C - 150°C, WTI CTR – 1070/5A, OIL/Wdg temp Rise – 50/55°C, Control Switch 02 Nos. & 05 meter capillary length.. |
| 10 | WTI for 250 KVA Voltamp make Raw Water Intake TransformersRange – 0°C - 150°C, WTI CTR – 335/5A, OIL/Wdg temp Rise – 50/55°C, Control Switch 02 Nos. & 05 meter capillary length.. |
| 11 | WTI for 50 MVAR GE Make ISP ReactorRange – 0°C - 150°C, WTI CTR – 70/2.0-1.5-1.0 A, OIL/Wdg temp Rise – 45/50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 12 | WTI for 63 MVAR BHEL Make Bus Reactor-IRange – 0°C - 150°C, WTI CTR – 87/2.2-2.0-1.8-1.6 A, OIL/Wdg temp Rise – 50/55°C, 04 micro switches, 10 to 12 meter capillary length. |
| 13 | WTI for 63 MVAR Bus Reactor-IIRange –30°C - 150°C, WTI CTR – 87/2.2-2.0-1.8-1.6 A, OIL/Wdg temp Rise – 45/50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 14 | WTI for 315 MVA BHEL make Inter Connecting Transformer (ICT) |
| 15 | (a) WTI for 315 MVA BHEL make Inter Connecting Transformer (ICT) , Range – 30°C - 150°C & WTI CTR – HV - 455/2.5-2.0-1.5 A, OIL/Wdg temp Rise – 40/45°C , over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 16 | (b) WTI for 315 MVA BHEL make Inter Connecting Transformer (ICT) Range – 30°C - 150°C & WTI CTR – IV - 919/2.9-2.5-2.1 A OIL/Wdg temp Rise – 40/45°C , over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length. |
| 17 | ( c ) WTI for 315 MVA BHEL make Inter Connecting Transformer (ICT) Range – 30°C - 150°C & WTI CTR – LV – 1837/3.0-2.7-2.4 A, OIL/Wdg temp Rise – 40/45°C , over Ambient of 50°C, 04 micro switches, 10 to 12 meter capillary length |
| 18 | OTI (Oil Temperature Indicator ) |
| 19 | OTI for HT Transformers / ReactorRange – 20°C - 140°C02 micro switches, 10 to 12 meter capillary length (For GT, ST , UAT, BUS Reactor- 1 & 2) |
| 20 | OTI for HT Transformers / ReactorRange – 0°C - 150°C,02 micro switches, 10 to 12 meter capillary length. ( For Ashta line and ISP Reactor ) |
| 21 | OTI for LT TransformersRange – 0°C - 150°C, Control Switch 02 Nos & 05 meter capillary length. ( For AHP, ESP, ESP TR Set, ETP, RW Intake Transformers ) |
| 22 | OTI for HT TransformerRange – 20°C - 140°C, 04 micro switches, 10 to 12 meter capillary length. ( For ,Inter Connecting Transformer (ICT) ) |
| 23 | CCU with inbuilt power supply / Transmitter along with RTD (PT 100) for Remote indication of WTI & OTI |
| 24 | CCU for 315 MVA BHEL MakeGenerating Transformers |
| 25 | (a) CCU for 315 MVA BHEL MakeGenerating TransformersRange WTI- 30°C - 150°C & WTI CTR – HV -456/3.2-2.8-2.3, OIL/Wdg temp Rise – 35/40°C over Ambient of 50°C. |
| 26 | (b) CCU for 315 MVA BHEL MakeGenerating TransformersRange WTI- 30°C - 150°C & WTI CTR – LV – 12000/5A, OIL/Wdg temp Rise – 35/40°C over Ambient of 50°C. |
| 27 | CCU for 20 MVA BHEL Make Unit Auxiliary Transformers WTIRange – WTI- 30°C - 150°C WTI LV CTR –-799.81/2.38-2.72-2.94-3.4-3.68, OIL/Wdg temp Rise – 50/55°C. |
| 28 | CCU for 50 MVA BHEL Make Station Transformers |
| 29 | (a) CCU for 50 MVA BHEL Make Station Transformers WTIRange – WTI- 30°C - 150°C – HV -81/2.8-2.4-2.0, OIL/Wdg temp Rise – 50/55°C over Ambient of 50°C |
| 30 | (b) CCU for 50 MVA BHEL Make Station Transformers WTIRange – WTI- 30°C - 150°C – LV1&2 – 2092/3.4-3.0-2.6A, OIL/Wdg temp Rise – 50/55°C over Ambient of 50°C. |
| 31 | CCU for 50 MVAR AREVA MAKE Sarni Astha ReactorRange – WTI - 0°C - 150°C, WTI CTR – 70/2 A, OIL/Wdg temp Rise – 50/55°C over Ambient of 50°C. |
| 32 | CCU for 50 MVAR GE MAKE ISP Reactor WTIRange – WTI - 0°C - 150°C, WTI CTR – 70/2.0-1.5-1.0 A, OIL/Wdg temp Rise – 45/50°C. |
| 33 | CCU for 63 MVAR BHEL Make Bus Reactor-I WTIRange – WTI - 0°C - 150°C, WTI CTR – 87/2.2-2.0-1.8-1.6 A, OIL/Wdg temp Rise – 50/55°C |
| 34 | CCU for 315 MVA BHEL make Inter Connecting Transformer (ICT) Range WTI- 30°C - 150°C |
| 35 | (a) CCU for 315 MVA BHEL make Inter Connecting Transformer (ICT) Range WTI- 30°C - 150°C & WTI CTR – HV - 455/2.5-2.0-1.5 A, OIL/Wdg temp Rise – 40/45°C over Ambient of 50°C. |
| 36 | (b) CCU for 315 MVA BHEL make Inter Connecting Transformer (ICT) Range WTI- 30°C - 150°C & WTI CTR – IV - 919/2.9-2.5-2.1 A OIL/Wdg temp Rise – 40/45°C over Ambient of 50°C. |
| 37 | (c) CCU for 315 MVA BHEL make Inter Connecting Transformer (ICT) Range WTI- 30°C - 150°C & WTI CTR – LV – 1837/3.0-2.7-2.4 A, OIL/Wdg temp Rise – 40/45°C over Ambient of 50°C. |
| 38 | CCU for OTI |
| 39 | (a) CCU for OTIRange – OTI- 20°C - 140°C, Input from PT100 Sensor Dual 4 - 20 mA DC output Signal (For GT, UAT, ST & ICT ) |
| 40 | (b) CCU for OTIRange – OTI- 0°C - 150°C, Input from PT100 Sensor Dual 4 - 20 mA DC output Signal (For Sarni- Ashta & ISP Reactor) |
| 41 | Transformer Protection System / Relay for 2 MVA Dry Type Transformer having Winding Temperature scanner 4 channels with 4-20 mA DC output suitable for auxiliary supply 90-260 V AC/DC, Range - 0-300°C, 4Nos. Pt-100 Sensor with 5 meters cable length Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender