Public Administrative Department Local Bodies Closing in 9 days TDR #58423256

Tender For Improvement Of Iei Infrastructure For Renovation Of Conference Room, Library Hall And Auditoriums Green Room At Navyug School, Sarojini Nagar Under Moti Bagh Wiring Enquiry, Bm-Ii Division.

Issued by Local Bodies · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Nov 2026
9 days left
EMD
11725
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvement Of Iei Infrastructure For Renovation Of Conference Room, Library Hall And Auditoriums Green Room At Navyug School, Sarojini Nagar Under Moti Bagh Wiring Enquiry, Bm-Ii Division.

BOQ

Name of Work:- Improvement of IEI infrastructure for renovation of Conference Room, Library Hall and Auditoriums Green Room at Navyug School, Sarojini Nagar under Moti Bagh Wiring Enquiry, BM-II Division.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required Group – C (a) Light point - 42 (b) Fan Point - 27 (c) Exhaust Point - 03
2Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4(b) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
7Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
9(b) Single pole and neutral
10Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 A
11Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 8 way , Double door
12(b) 12 way, Double door
13Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25 mm
14LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 1.20 mm) (a) 36 watt
15SITC of Exhaust fan double ball bearing heavy duty, Size 12\\" (300mm sweep) complete with motor, 3/4 blades sets down double ball bearing and motor should be copper winding performs well at low voltage, Low Noise, RPM 1400, Operating Voltage 220/240 V, 50 Hz, Grey/Black color. Warranty 02 years from the date of supply/installation, Make:- Atomberg/ Havells/ Orient/ Usha
16Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
17Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
18Deduct - Credit for old dismantled materials (Rs.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58423256
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 16-11-2026
Authority
Authority Name New Delhi Municipal Council
Work Description Tender for Improvement Of Iei Infrastructure For Renovation Of Conference Room, Library Hall And Auditoriums Green Room At Navyug School, Sarojini Nagar Under Moti Bagh Wiring Enquiry, Bm-Ii Division.
Basic Detail
Tender No 64/EE (BM-II) E/26-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 06 Nov 2026
Submission Date 16 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 11725
Exemption Not Available
Document List
BOQ_401872.xls
dc790dc4-199a-4cea-90d9-d31ee8bb5aac.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_401872.xls

html

dc790dc4-199a-4cea-90d9-d31ee8bb5aac.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender