Drinking Water Supply and Sanitation Government Departments Closing in 13 days TDR #58423178

Tender For Construction & Commissioning Of 05 Nos. 200 Mm Dia Three Phase Tube Well & Providing, Laying And Jointing Of Hdpe Pipe Line With One Year Defect Liability Period At Uwss Sawai Madhopur.

Issued by Government Departments · Sawai Madhopur, Rajasthan
Tender Value
48.59 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
13 days left
EMD
97180
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sawai Madhopur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction & Commissioning Of 05 Nos. 200 Mm Dia Three Phase Tube Well & Providing, Laying And Jointing Of Hdpe Pipe Line With One Year Defect Liability Period At Uwss Sawai Madhopur.

BOQ

Name of Work:- Construction & Commissioning of 05 Nos. 200 mm dia three phase Tube Well & Providing, laying and jointing of HDPE Pipe Line with One year Defect Liability Period at UWSS Sawai Madhopur.
Sl. No. Item Description
1Construction of Tube Well (Rates are based on Revised PHED BSR 2023 exclusive of GST )
2Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.
3Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
4Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
5Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.200 mm dia nominal bore of 5.4mm thickness
6Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.
7Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect
87.5 KW (10 HP) & head above 120 mtr.
99.3 KW (12.5 HP) & head above 120 mtr.
10Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
11Above 10 HP and up to 15 HP
12Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
133 core 6.0 Sq.mm
14Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
1525.0 Sq.mm, 3.5 core
16Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm dia
17Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect.
1850 mm dia
19Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with lockingarrangement of following dia.
2050 mm dia
21Providing & Fixing of double flanged, CI body, ISI marked NRV of approvedmake of following sizes
2265 mm dia
23Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as perspecification with safety cover.
24Pipe Line
25Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.
26HDPE PE-80 PN-6
2790 mm dia
28110 mm dia
29HDPE PE-80 PN-10
3090 mm dia
31Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil
32Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
33Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
34Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0
3580 mm HW
36100 mm HW Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58423178
AUTHORITY Government Departments
TENDER VALUE 48.59 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Construction & Commissioning Of 05 Nos. 200 Mm Dia Three Phase Tube Well & Providing, Laying And Jointing Of Hdpe Pipe Line With One Year Defect Liability Period At Uwss Sawai Madhopur.
Basic Detail
Tender No 50/2026-27 UWSS SWM
Bidding Type Tender
Location
City Sawai Madhopur
State Rajasthan
Key Dates
Publish Date 06 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 48.59 Lakhs
Tender Fee 2500
EMD 97180
Exemption Available
Document List
50TD.pdf
BOQ_1073764.xls
db798118-2c72-4fad-894f-2988d66bc543.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

50TD.pdf

xls

BOQ_1073764.xls

html

db798118-2c72-4fad-894f-2988d66bc543.html

pdf

Tendernotice_1.pdf

Disclaimer