Tender For Maintenance & Repair Of Bulding Number -D2 At Teesta Pally, Tinbatti , Siliguri Under Mahananda Barrage Division
Tender Value
3.84 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
18 days left
EMD
7694
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance & Repair Of Bulding Number -D2 At Teesta Pally, Tinbatti , Siliguri Under Mahananda Barrage Division
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling artificial stone flooring up to 50 mm thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m a) In ground floor including roof. |
| 2 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m In ground floor including roof.a) up to 150 mm thick |
| 3 | Artificial stone in, floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panelsas directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including racking out joints or roughening of concrete surface and application of cement slury before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In Ground Floor 3 mm thick toping (High polishing grinding on this item is not permited with ordinary cement) using grey cement. |
| 4 | Stripping off worn out plaster and racking out joints od walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75 m as directed. |
| 5 | Plaster (to wall, floor, ceiling etc) with sand and cement morter including rounding off or chanfering corners as directed and racking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (Ground Floor). (Excluding cost of chipping over concrete surface).ii) With 1:4 cement morter.b) 10 mm thick plaster. |
| 6 | Plaster (to wall, floor, ceiling etc) with sand and cement morter including rounding off or chanfering corners as directed and racking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (Ground Floor). (Excluding cost of chipping over concrete surface).ii) With 1:4 cement morter.c) 15 mm thick plaster. |
| 7 | Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly (i) Internal surface (All floors)(a) One coat of colour wash(i) Other than yellow, pink. |
| 8 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i)River Bazree |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (up to roof or ground floor).(When the height of a particullar floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4m height shall be alloued under 12(e) for every 4m or part thereof.) a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge. |
| 10 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 11 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete,iron Butt Hinges and M.S clamps (The quantum should be corrected upto three decimals)(i) Other Local Wood. |
| 12 | Panel Shutters of door and window as per design (each panel consisting of single plank without joint).including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm.(c) Other Local Wood. |
| 13 | Supplying fitting & fixing approved brand 32mm dia P.V.C. waste pipe, with P.V.C coupling at one end fitted with necessary clamps. ii) 750 mm long |
| 14 | Supplying fitting & fixing approved brand P.V.C. CONNECTOR white flexible with both ends coupling with heavy brass C.P. nut,15 mm dia. ii)450 mm long |
| 15 | Dismantling Orissa pattern W.C. including taking out of base concrete, if necessary, complete. |
| 16 | Supplying,fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding ‘P’ or ‘S’ trap (excluding cost of concrete for fixing) i) 580 mm X 440 mm |
| 17 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 |
| 18 | 15 mm |
| 19 | 20 mm |
| 20 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking andbending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawingand direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel III. OTHER MANUFACTURERS NOT SPECIFIED |
| 21 | Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4kg. Per sq.m. /3mm thick) fitted with putty bed and teak wood beads and nails including fitting and fixing shutters in position but excluding the cost of glass,putty, teak bead, nails, hinges etc. and other fittings, in ground floor.(iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm.(c) Other Local Wood. |
| 22 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(e) 2500 litre capacity |
| 23 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 |
| 24 | (A) (i) Single Socketed 3 Meter Length(a) 75 mm |
| 25 | (A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 26 | (B) Fittingsxvii) W.C. Connector (150 mm long) 125 X 110(W/WC Ring)75 mm |
| 27 | (B) Fittings xxiii) 110/110 S Trap 75 mm |
| 28 | (B) Fittingsxvi) Pipe Clip 75 mm |
| 29 | (B) Fittingsx) Bend 87.5º (a) 75 mm |
| 30 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessaryspecials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder batclamps (any floor) or for underground work including cutting trenchesupto 1.5 metre and refilling the same complete as per direction of theEngineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials(A)Above ground |
| 31 | (i) 75 mm dia. |
| 32 | (ii) 110 mm dia. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer