Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58421819

Tender For maintenance of electrical installation & Fans, repair maintenance A/C Equipment, Pump Set At Residences Near Tilak Marg, Darya Ganj, Chanakya Puri & Other Nearby Areas New Delhi (Sh:- Electrical Repairing Work In Quarters And Bungalows).

Issued by Government Departments · Delhi, Delhi
Tender Value
54.89 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
6 days left
EMD
1.09 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of electrical installation & Fans, repair maintenance A/C Equipment, Pump Set At Residences Near Tilak Marg, Darya Ganj, Chanakya Puri & Other Nearby Areas New Delhi (Sh:- Electrical Repairing Work In Quarters And Bungalows).

BOQ

Name of Work:- MOEI & Fans, RMO A/C Equipment, Pump Set at residences near Tilak Marg, Darya Ganj, Chanakya Puri & other nearby areas New Delhi (SH:- Electrical Repairing Work in Quarters and Bungalows).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.(a) Group B
2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
5Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(a) Group B
6Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
8(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
9(d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
10Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(a) Group B
11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3 X 1.5 sq. mm
12(b) 3 x 4 sq. mm
13(c) 3 x 6 sq. mm
14Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25 mm
15Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
16Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
17Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.10.1) 1 or 2 Module (75 mmX75 mm)
1810.2) 6 Module (200 mmX75 mm)
1910.3) 12 Module (200 mmX150 mm)
20Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 A switch
21(b) 15/16 A switch
22(c) 6 pin 15/16 A socket outlet (universal socket)
23(d) Telephone socket outlet
24(e) TV antenna socket outlet
25(g) Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568. 2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
26Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
27Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
28Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.(a) 1 run of cable
29Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(a) 8 way (4 + 24), Double door
30(b) 4 way (4 + 12), Double door
31Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)(a) 12 way, Double door
32Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
33Supplying and fixing following rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 A
34Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 19.1) 100 A TP&N
3519.2) 125 A TP&N
36Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 20.1) For 4 way, Double door TPN MCBDB
3720.2) For 8 way, Double door TPN MCBDB
38Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
39Supplying and drawing 2 pair 0. 5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
40Supplying, installation, testing & commissioning of Decorative type 1200-1320mm BLDC Ceiling Fan, Whisper Quiet, with or without Remote Controlled , aerodynamically design ABS Blades, Ultra-Quiet Performance, High Air Delivery, Energy-Efficient, BLDC Motor, Durable & Bend-Proof ABS Blades, Premium Aesthetic Appeal, Wattage 40W, Air Delivery 230 CCM, Speed 280-300 RPM etc. including connect with 1.5 sqmm wire etc. complete as required. Note: Design of the celing fan shall be decided by Engineer-in-charge.
41Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in allrespect i/c external connections with1.5 sq mm FRLS/HFFR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and alltesting requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sinkof aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0. 50 mm) (a) 36 watt
42Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and alltesting requiredfor LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sinkof aluminium housing such that LED junction temperature shall not rise above 90°C).(a) 150 watt
43(b) 50 Watt
44Supplying and installation of following wall mounted fancy decorative light fitting made of brass body with designer glass & LED bulb complete with testing & commissioning connection etc. as required. (Sample shall be approved by Engineer-in-charge).(a) Single Arm with 9/12 Watt Bulb
45(b) Double Arm with 9/12 Watt Bulb
46Supplying, installation, testing & commissioning of ceiling mounting decorative Pendant Light made of brass & glass of minimum diameter 10 inch with adustable cord length and suitable lamps etc. complete as required. (Sample shall be approved by Engineer-in-charge).
47Supplying, installation, testing & commissioning of following capacity water storage vertical type geyser working on 230 +/- 10 V single phase 50 Hz frequency, tank with altra thick super cold rolled steel plates, puff insolation, rated pressure: 8 bar, Temperature range 75 degree C, heating indicator, temperature setting: manual, power consumption: min 2 kw i/c Thermostate, Thermal cut off, multifactionalsafety valve complete with necessary accessories & flexible heavy duty pvc connection of suitable length (2 Nos.) and 25 amp plug top etc, as reqd.(a) 35 Liters Capacity
48(b) 25 Liters Capacity
49(c) 10 Liters Capacity
50LED Down lighter (COB Type) (System lumen efficacy =105 < 120 lm/Watt).Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector (a) 12 -15 watt
51Supplying & fixing of 15-25 mm Aluminium Conceal Profile with LED flexible strip light of warm white of 20-25 watt per 5 mtr. with driver complete with connetion, testing etc. complete as required.
52Supplying, installation, testing & commissioning of 5-10 watt LED garden spike light, aluminium body, color temperature: 3000K, IP rating: 65, lumens: 90 lumens per watt etc. complete as required. The fitting shall be grouted with the help of making suitable size of cc foundation.
53Supplying, installation, testing & commissioning of wall mounting 10 watt Decorative Brass Antique Picture/ mirror LED Light including connection with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc. as required. (Sample shall be approved by Engineer-in-charge).
54Supplying, installation, testing & commissioning of 8-11 watt LED Decorative Bollard Fitting of minimum nominal size 800-1000 mm height, pressure die-cast aluminium housing, primer coated and painted with polyurethane paint, protection grade of IP66 complete suitable for working on 240V, 50Hz, single phase AC supply complete with making suitable concrete with iron rod foundation including connections etc. as required. (Sample shall be approved by Engineer-in-charge).
55Supplying, installation, testing & commissioning of 8-11 watt LED Decorative Bollard Fitting of minimum nomial size 800-1000 mm height, pressure die-cast aluminum housing, primer coated and painted with polyurethane paint, protection grade of IP66 complete suitable for working on 240V, 50Hz, single phase AC supply complete with making suitable concrete with iron rod foundation including connections etc. as required. (Sample shall be approved by Engineer-in-charge).
56Supplying, installation, testing and commissioning of RO having tank capacity of 6 to 8 ltrs with flow rate 20 ltrs per hours with the help of connection pipe i/c fixing of incoming & outgoing connections on the wall with the help of fastners/screws etc. complete as required.
57Supplying and fixing of single phase 1 HP Monoblock Pump Set, 1500 RPM, 25 mm x 25 mm suction & delivery pipe line, capable to deliver 2800 - 880 LPH at the head of 18 - 45 mtr. i/c making good the damaged foundation complete with connection, testing etc. as required.
58Supplying and installation of 1 HP(0.75Kw), single phase horizontal openwell submersible pump set having 32 x 25 mm delivery pipe line capable to deliver 140 - 10 LPM at the head range of 12 - 27 mtrs. including lowering the pump set in the water tank complete with making water proof joint, connection, testing & commissioning etc. as required.
59Supplying and fixing of single phase Pressure Booster Pump of 0.5 HP, 0.37Kw, 25mm X 25 mm suction & delivery, 6 - 24 mtrs. head range, 33 - 7 LPM discharge range including making good the damaged foundation complete with connection, testing & commissioning etc. as required.
60Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.
61Supplying, installation, testing and commissioning of following size fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as required.(a) 250 mm
62(b) 200 mm
63Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
64Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximumpower consumptionshould notmore than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housingComplete inall respect i/c externalconnections with1.5 sq.mm FRLS/HFFR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and alltesting requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coateddie cast /Extruded aluminium Body including trim(a) 12 -15 watt
65LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete inall respect i/c externalconnections with1.5 sqmm FRLS/HFFR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and alltesting requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sinkof aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0. 50 mm) (a) 36 watt
66Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
67Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade complete as required.(a) 3 x 10 sq.mm in pipe
68(b) 3 x 10 sq.mm in surface
69(c) 4 x 25 sq.mm in pipe
70(d) 4 x 25 sq.mm on surface
71Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
72Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
73Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
74Supply, Installation, Testing and Commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only49.01) 2.0 TR with 4/5 Star BEE Rating
7549.02) 1.5 TR with 4/5 Star BEE Rating
76Supplying and fixing of M.S. outdoor, floor/ wall mounting powder coated stand suitable for 1.5/2.0 Ton capacity split type A.C. outdoor unit complete as required.
77Supplying, installation, testing and commissioning of 5 KVA (170v-270v), copper wounded, wall mounted voltage stabilizer with LED display, surge indicator, automatic reset complete etc. as required.
78Providing &Laying of refrigerant copper piping of size 1/4\\" or 3/8\\" & 5/8\\" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable i along with necessary support complete etc all as per Direction of Engineer-in-charge.
79Supplying & drawing of 3x4 sqmm size of PVC insulated &pvc sheathed copper conductor round multicore flexible cable for indoor to outdoor and upto nearest power point i/c providing suitable copper lugs connection etc. as required.
80Providing & fixing of 25 mm dia (SDR-13.5) UPVC heavy duty white colour drain pipe of with necessary fitting such as nipple, reducer, clamp on surface / recess i/c cutting the wall and making good the same complete as required.
81Supplying, installation, testing and commissioning of led strip light i/c connectors in the existing cove with suitable connection complete as required
82Less for credit of dismantle items Assorted copper wire/cable, scrap iron/ conduit/ box, switches-sockets, DBs (assorted size), MCBs (assorted size), Ceiling Fans (assorted size), Fresh Air Fan (assorted size), Exhaust Fan (assorted size), Light Fittings (assorted size), Geyser (assorted), assorted XLPE aluminium cable, AC units etc. complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58421819
AUTHORITY Government Departments
TENDER VALUE 54.89 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for maintenance of electrical installation & Fans, repair maintenance A/C Equipment, Pump Set At Residences Near Tilak Marg, Darya Ganj, Chanakya Puri & Other Nearby Areas New Delhi (Sh:- Electrical Repairing Work In Quarters And Bungalows).
Basic Detail
Tender No 172/EEE/PWDDHC,NDC/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 06 Nov 2026
Submission Date 13 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 54.89 Lakhs
Tender Fee Ref. Documents
EMD 1.09 Lakhs
Exemption Not Available
Document List
BOQ_401906.xls
fbae3c11-d793-4a2a-bb3f-748cea4680d2.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_401906.xls

html

fbae3c11-d793-4a2a-bb3f-748cea4680d2.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender