Tender For Shifting Of 11 Kv Oh Line From The Premises Of The Industrial Units M/S Samaleswari Industries & M/S Urban Infra At Phase-Ii, Balangir, Sadeipali.
Tender Value
14.15 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
9 days left
EMD
14160
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Shifting Of 11 Kv Oh Line From The Premises Of The Industrial Units M/S Samaleswari Industries & M/S Urban Infra At Phase-Ii, Balangir, Sadeipali.
BOQ
| Sl. No. | Item Description |
| 1 | Cost of Material for 11 mtr , 13 mtr rs joist pole and 100sqmm insulated covered conductor. |
| 2 | Supply & installation of all reqd. materials for 11 mtr 150X150 RS Joist Pole 34.6Kg/m with excavation of pole pit in all kinds of soil and rock up to depth of 1/6 th of the pole-length/height & with Concreting of poles in ratio 1:1.5:3 (M-20 grade) (500mmX500mm X1800mm) = 0.45Cu.mtr & Couping of poles in ratio 1:1.5:3 (M-20 grade) (500X500X450)= 0.1125 Cu mtr along with curing as required and for supports. complete as required & as per approved technical specification and direction of EIC. |
| 3 | Supply & installation of all reqd. materials for 13 mtr 150X150 RS Joist Pole 34.6Kg/m with excavation of pole pit in all kinds of soil and rock up to depth of 1/6 th of the pole-length/height & with Concreting of poles in ratio 1:1.5:3 (M-20 grade) (500mmX500mm X2200mm) = 0.55Cu.mtr & Couping of poles in ratio 1:1.5:3 (M-20 grade) (500X500X450)= 0.1125 Cu mtr along with curing as required and for supports. complete as required & as per approved technical specification and direction of EIC. |
| 4 | SITC of 100 sq.mm. Insulated covered conductor complete as per approved technical specification and direction of E.I.C. |
| 5 | Cost of Material for 11 KV DP with 400 Amp AB Switch - 2 Nos |
| 6 | SITC of 100 sq.mm. Insulated covered conductor complete as per approved technical specification and direction of E.I.C. |
| 7 | Supply and installation of Top Channel 100x50x6 mm,Bracing Channel 70x40x6 mm & Bracing Angle 50x50x6 mm with Fabrication & Galvanisation complete as per approved technical specification and direction of E.I.C. |
| 8 | Supply and Installation of GI Flat 50x6 mm . complete as per approved technical specification and direction of E.I.C. |
| 9 | Supply and Installation of GI Flat 25x3 mm. complete as per approved technical specification and direction of E.I.C. |
| 10 | Supply and Installation of Fish Plate 50X6mm. complete as per approved technical specification and direction of E.I.C. |
| 11 | SITC of Lightning Arrester (12KV,10KA) Station Class .complete as per approved technical specification and direction of E.I.C. |
| 12 | SITC of 11kV Disc Insulator B & S , Polymer complete as per approved technical specification and direction of E.I.C. |
| 13 | SITC of 11kV H/W Fitting (B & S type) for Disc Insulator complete as per approved technical specification and direction of E.I.C. |
| 14 | Supply and Installation of Aluminium Socket 120mm. complete as per approved technical specification and direction of E.I.C. |
| 15 | SITC of A.B. Switch (11 KV, 400A, 3pole, 50Hz) .complete as per approved technical specification and direction of E.I.C. |
| 16 | Supply and Installation of PG Clamp for 100 sqmm AAAC. complete as per approved technical specification and direction of E.I.C. |
| 17 | SITC of 11 kV HT Stay Set complete including excavation of stay pit in all kind of soil and rock as required with GI HT Stay Set, Stay Clamp , Stay Insulator & 7/10 GI stay Wire & Stay Concreting ratio 1:1.5:3 (M-20 grade) (500 mm x 500mm x 800mm) = 0.2 Cu.mtr complete with curing as required & as per approved technical specification & direction of EIC. |
| 18 | SITC of earth electrode made out of 40 mm dia class-B G.I Pipe of 3 mtr. Long with arrangements for fitting and termination of G.I Flat/G.I wire with G.I nut-bolts and washers including cost of burnt wood charcoal salt/Bentonite Powder, bricks masonry chamber with removable RCC cover complete with labour for excavation of pit in all kinds of soil and rock complete as per technical specification of TPWODL and direction of E.I.C. |
| 19 | Supply & fixing of G.I Nut, Bolt & Washers as required. |
| 20 | SITC of Anticlimbing Device using GI barbed wire (2kg per support) with Back Clamp (25X3 mm GI flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)). complete in all respect as per approved technical specification and direction of E.I.C. |
| 21 | Supply and installation of Danger Plate using GI Back clamp (Pole-clamp) made of 25x3 mm flat flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510). complete in all respect as per approved technical specification and direction of E.I.C. |
| 22 | Cost of Material for 11 KV line Tapping point - 1 Nos |
| 23 | Supply and installation of 75x40x6mm. Channel for Straight Cross- arm (1.2mtr.X 4nos) with Fabrication & Galvanisation complete as per approved technical specification and direction of E.I.C. |
| 24 | Supply and Installation of Bracing angle 50x50x6mm.-2x4mtr. Long, (4.5Kg./mtr.) . complete as per approved technical specification and direction of E.I.C. |
| 25 | Supply and Installation of GI Flat 50x6 mm . complete as per approved technical specification and direction of E.I.C. |
| 26 | SITC of 11kV Disc Insulator B & S , Polymer(70 KN) complete as per approved technical specification and direction of E.I.C. |
| 27 | SITC of 11kV H/W Fitting (B & S type) (70 KN) for Disc Insulator complete as per approved technical specification and direction of E.I.C. |
| 28 | Supply and Installation of PG Clamp for 100 sqmm AAAC. complete as per approved technical specification and direction of E.I.C. |
| 29 | SITC of 11 kV HT Stay Set complete including excavation of stay pit in all kind of soil and rock as required with GI HT Stay Set, Stay Clamp , Stay Insulator & 7/10 GI stay Wire & Stay Concreting ratio 1:1.5:3 (M-20 grade) (500 mm x 500mm x 800mm) = 0.2 Cu.mtr complete with curing as required & as per approved technical specification & direction of EIC. |
| 30 | SITC of Earthing of support (Coil Type) complete as per approved technical specification and direction of E.I.C. |
| 31 | SITC of No 8 GI wire for earthing complete as per approved technical specification and direction of E.I.C. |
| 32 | Supply & fixing of G.I Nut, Bolt & Washers as required. |
| 33 | SITC of Anticlimbing Device using GI barbed wire (2kg per support) with Back Clamp (25X3 mm GI flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)). complete in all respect as per approved technical specification and direction of E.I.C. |
| 34 | Supply and installation of Danger Plate using GI Back clamp (Pole-clamp) made of 25x3 mm flat flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510). complete in all respect as per approved technical specification and direction of E.I.C. |
| 35 | Cost of Material for 11 KV Pin Point - 9 Nos |
| 36 | Supply & installation of 11KV GI V-Cross arm with G.I Back Clamp for V cross arm. complete as required & as per approved technical specification & direction of EIC. |
| 37 | SITC of 11KV Pin Insulator, Polymer complete as per approved technical specification and direction of E.I.C. |
| 38 | Supply and Installation of F Clamp . complete as per approved technical specification and direction of E.I.C. |
| 39 | Supply & fixing of G.I Nut, Bolt & Washers as required. |
| 40 | SITC of Earthing of support (Coil Type) complete as per approved technical specification and direction of E.I.C. |
| 41 | SITC of No 8 GI wire for earthing complete as per approved technical specification and direction of E.I.C. |
| 42 | SITC of Anticlimbing Device using GI barbed wire (2kg per support) with Back Clamp (25X3 mm GI flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)). complete in all respect as per approved technical specification and direction of E.I.C. |
| 43 | Supply and installation of Danger Plate using GI Back clamp (Pole-clamp) made of 25x3 mm flat flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510). complete in all respect as per approved technical specification and direction of E.I.C. |
| 44 | SITC of 11 kV HT Stay Set complete including excavation of stay pit in all kind of soil and rock as required with GI HT Stay Set, Stay Clamp , Stay Insulator & 7/10 GI stay Wire & Stay Concreting ratio 1:1.5:3 (M-20 grade) (500 mm x 500mm x 800mm) = 0.2 Cu.mtr complete with curing as required & as per approved technical specification & direction of EIC. |
| 45 | Cost of Material for Guarding for road crossing - 1 Nos |
| 46 | Supply and Installation of MS Channel 75 X40X6mm . complete as per approved technical specification and direction of E.I.C. |
| 47 | Supply and Installation of GI Flat 50X6 . complete as per approved technical specification and direction of E.I.C. |
| 48 | Supply and Installation of No.8 GI wire (Dia-4.6mm) . complete as per approved technical specification and direction of E.I.C. |
| 49 | Supply and Installation of No.6 GI wire (Dia-4.8mm) . complete as per approved technical specification and direction of E.I.C. |
| 50 | Supply and Installation of Eye Hook . complete as per approved technical specification and direction of E.I.C. |
| 51 | Supply & fixing of G.I Nut, Bolt & Washers as required. |
| 52 | Cost of Dismantling of Material |
| 53 | Dismantling of 3ph 11 Kv line. complete as per direction of E.I.C. |
| 54 | N.B: The bidders are required to Quote theire rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender