Tender For Addition/Alteration To Bldg No T-8 At Af Stn Bihta.
Tender Value
29.09 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
19 days left
EMD
58180
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patna → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/Alteration To Bldg No T-8 At Af Stn Bihta.
BOQ
| Sl. No. | Item Description |
| 1 | B/R WORKS |
| 2 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified. |
| 4 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified. |
| 5 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. |
| 6 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 7 | PCC type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in in roof kerbs or mud stops, rounded or chamfered on edges, using water proofing compound, complete all as specified. |
| 8 | PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified. |
| 9 | PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified. |
| 10 | Cement concrete, type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified. |
| 11 | Reinforced cement concrete, type B-1,(1:2:4), (nominal mix) using 20 mm graded stone aggregates as as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified |
| 12 | Brick work using using bricks as specified in PS-II clause 5.1 straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 13 | Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified. |
| 14 | Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified. |
| 15 | Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforced with mild steel square tube, suppling & fixing in opening, complete all as specified. |
| 16 | Factory made uPVC white colour casement/sliding window/door, made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2+0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, all complete and as directed, (Glazing, hardware hinges and fitting, EPDM rubber gasket etc. to be paid separately.) complete all as specified. Note:-Each member of window to be measured separately wrth clear length. |
| 17 | Factory made uPVG white colour Sliding window ( Area exceeding 2.00 sqm each) Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated),steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 18 | Factory made, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 35 mm thick, ISI marked, complete all as specified. |
| 19 | Factory made 35 mm thick ,2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, etc complete all all as specified. |
| 20 | Factory made solid PVC moulded door shutter, 28-30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2 mm thick prelam PVC sheet on back face, all as per specification complete all as specified. |
| 21 | Aluminium anodised barrel tower bolt of extruded section 200mm long, ISI marked, complete all as specified. |
| 22 | Roller blind curtain suitable for office, guest room including fitting complete all as specified. |
| 23 | Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 300 mm long, complete all as specified. |
| 24 | Stainless steel 100mm long butt hinges with stainless steel screws, ISI marked complete all as specified. |
| 25 | Extruded aluminium anodised handles fabricated type with plate 150 mm long, ISI marked complete all as specified. |
| 26 | Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, complete. |
| 27 | Aluminium (Die cast) door closer hydraulically regulated designation No. 2 aluminium body universal type suitable for door shutters of 701 to 850 mm in width and weight between 36 to 60 kg, ISI marked, complete all as specified. |
| 28 | Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks or steel wire staples, all as specified. |
| 29 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 30 | Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified. |
| 31 | Framed mild steel work as in door or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guide) and hanging also fastening and fixing complete all as specified. |
| 32 | Mild steel rolled sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to grade Fe-410-Gde E-250, complete all as specified. |
| 33 | Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified. |
| 34 | Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed, IN REPAIR (each line wire to be measured) complete all as specified. |
| 35 | Supply only mild steel galvanised iron hot dipped 4mm dia wire chain link fencing not exceeding 4.00 Kg/ Sq.m of approved mesh size complete all as specified. |
| 36 | Fixing only chain link fencing including line wire mesh, any mesh, size and type to any types of standards rails, straining bolts, etc. including provision of binding wire complete, all as specified. |
| 37 | Mild steel round bars 10mm dia and over, cut to length, bent to shape required, for chain link fencing complete, all as specified. |
| 38 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm not exceeding 10cm long, dia of neck 11 to 15 mm, complete all as specified. |
| 39 | Pressed steel frames of size 105 mm x 60 mm made out mild sheet 1.25 mm thick, for doors with one or more rebates including necessary fixing lugs, 100 mm size medium grade mild steel hinges, lock strike plates etc including providing PCC (1:3 :6) type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified. |
| 40 | Pressed steel frames of size 125 mm x 60 mm made out mild sheet 1.25 mm thick, for doors with one or more rebates including necessary fixing lugs, 100 mm size medium grade mild steel hinges, lock strike plates etc including providing PCC (1:3 :6) type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified. |
| 41 | Water Proofing Treatment to RCC roofs comprising of : - |
| 42 | Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified. |
| 43 | Rendering 15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ. |
| 44 | APP based polymeric membrane minimum weighing 3Kg/Sqm & minimum 2mm thick, laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified. |
| 45 | Roof cool tile of size 300 x 300mm thick 8-9 mm thick to reduce room temperature slip resistance white in colour having properties like water absortion max 3.3 % breaking strength 1000N moisture expansion max 3 % scratch hardness 4 min thermal stock resistance 10 cycles min impact resistance 0.55, and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified. |
| 46 | Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ. |
| 47 | NOTE : For Guarantee of Water Proofing Treatment refer PS clause 11.5. |
| 48 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws comlete all as specified. |
| 49 | Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour having tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws comlete all as specified. |
| 50 | 0.80mm thick plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with self tapping screwscomlete all as specified. |
| 51 | Anodised powder coated GI snap grid frame work including suspenders with size of grid 605 mm x 605 mm for false ceiling and shown on serial page No. 186 of MES Schedule Part-II.complete, all as specified. |
| 52 | Hangers 2-3 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs / trusses by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 53 | 4 mm thick calcium silicate tile, cut to size and fixed in grid frame work ceiling as panels, complete. |
| 54 | 5mm thick solid / hollow panel wall panelling of any colour over 5-8mm wide and 4-5mm thick PVC rubber beading fixed with nails etc for framing as per manufacture instruction and also provided chamfered / rounding at corner with machine moulding complete all as specified.Note:- Colour as approved by GE/Stn HQ |
| 55 | 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & fair without using extra cement, as in sub floors, complete all as specified. |
| 56 | 50 mm thick, cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate, finished even & finished even & fair without using extra cement, as in floors, complete all as specified. |
| 57 | 75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified. |
| 58 | 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in floors/path , sub base complete all as specified. |
| 59 | Glazed ceramic coloured tiles 7-8 mm thick, area of each tile exc. 0.13 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified |
| 60 | Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:6), complete all as specified. |
| 61 | Coloured vitrified dark shade tiles 9-10mm thick (square/ rectangular) area of each tile n. exc. 0.36 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified. |
| 62 | Coloured vitrified dark shade tiles 9-10mm thick (square/ rectangular) area of each tile n. exc. 0.36 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified |
| 63 | Factory made PCC glossy finished, colured chequered tiles, ISI marked, 22-25 mm thick, of size 250 mm x 250 mm, in floors, over & including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete, all as specified. |
| 64 | 60 mm thick factory glossy finished coloured, made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete. |
| 65 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified. |
| 66 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth on walls in cement mortar (1:4), complete all as specified. |
| 67 | Supply only liquid water proofing compound, ISI marked, complete all as specified. |
| 68 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats & smoothening the surfaces etc. as specified (preparatory to paint as directed). (b) Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer. |
| 69 | Prepration of new plasterd ceiling surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer. |
| 70 | Complete removal of existing treatment of any description, including prepration of wall, chajjas, coloumn, beams etc surfaces of any description & Applying two coats of exterior acrylic emulsion over and including a coat of water based exterior primer complete all as specified. |
| 71 | Prepration of new plasterd wall, chajjas, coloumn, beams surfaces of any description & applying Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer complete all specified |
| 72 | Two coats of white washing on old ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 73 | Sheet glass 5 mm thick ordinary quality and glazing with rubber gasket in squares n. exc. 0.5sqm in each pane complete all as specified. |
| 74 | 10-12mm thick toughned glass as in hinged doors (floor door spring) partitions automatic door and similar work including cutting to shape, drilling holes required complete all specified |
| 75 | One coat (finishing coat) of synthetic enamel paint over wood and wood based surfaces of any description not other wise described over 10cm width or girth, including preparation of surfaces, complete all as specified. |
| 76 | Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 77 | One coat (finishing coat) of synthetic enamel paint over old painted steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 78 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 79 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel & iron (new) surfaces of any description, not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified. |
| 80 | Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking down existing tube complete all as specified of size: - |
| 81 | 15 mm bore |
| 82 | 20 mm bore |
| 83 | 500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, IN-REPAIRS, complete all as specified including the following acessories: -(i) PTMT ball valves, high pressure, with epoxy coated aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified.(iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified.(iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP, IN REPAIRS, complete all as specified. |
| 84 | Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. |
| 85 | Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT, complete. |
| 86 | Pillar tap, cast copper alloy chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPLACEMENT, complete. MAKE: Prayag Cat No. 6502 or equivalent make mentioned in Appendix 'B' |
| 87 | Two way control tap 15 mm bore chromium plated, valve cast copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 88 | Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including stainless steel body Jet spray (L-bend) with 1.50 metre long braded tube tube, soft close ISI marked PVC seat & cover, , complete all as specified. |
| 89 | Viterous china urinal bowl type(back), of size 465x355x265mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal aginst wall in cement mortar 1:2 incl urinal spreader all as specified. |
| 90 | Vitreous China wash basin, white, flat type, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPAIRS, complete all as specified. |
| 91 | PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, complete. |
| 92 | Looking mirror 600 x 450 mm, selected quality glass 5.5 mm thick, mounted on PVC ply not less than 6 mm thick, and provision of PVC frame alround fixed with chromium plated brass screws and rawl plugs,IN REPLACEMENT complete all as specified. |
| 93 | Tubular towel rail brass chromium plated, 20mm dia D type 60cm long complete all as specified. |
| 94 | Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, complete. |
| 95 | PVC connections 15 mm size of length 600 mm with PTMT nuts, complete all as specified |
| 96 | uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors / fixed to wall as SWR pipes, complete all as specified of size: - |
| 97 | 75 mm external dia pipe |
| 98 | 110 mm external dia pipe |
| 99 | uPVC/PVC bend any radius, complete all as specified. suitable for uPVC soil waste discharge pipes, of size: |
| 100 | 75 mm external dia pipe |
| 101 | 110 mm external dia pipe |
| 102 | uPVC/PVC junction, single T, equal or unequal, suitable for uPVC soil waste discharge pipes 110 mm external dia, complete all as specified. |
| 103 | uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified. |
| 104 | 75mm dia uPVC / PVC floor trap with grating including jointing with solvent and embedding in cement concrete type B-1 (1:2:4) complete all as specified. |
| 105 | E/M WORKS |
| 106 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI sunken boxes made out of 1.2mm thick MS sheet, 60mm deep concealed in wall modular metal flush box & including modular cover plate with frame having necessary cutting for fixing switches/ sockets comprising the following: - |
| 107 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 108 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 109 | One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 110 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 111 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). |
| 112 | Switch modular type single pole one way, 6 Amp, 1 module complete all as specified. |
| 113 | Switch modular type single pole one way, 16 Amp, 1 module complete all as specified. |
| 114 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified. |
| 115 | Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, 2 Module complete all as specified. |
| 116 | Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified. |
| 117 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 118 | Lamp (angle) holder, PVC/ polycorbonate type with back plate suitable for batten fittings complete, all as specified. |
| 119 | Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specified for the following: - NOTES: (i) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \\"1 RUNNING METRE\\" |
| 120 | 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 121 | Sheet metal enclosure SPN, 8 way with 100 Amp rated bus bar, 240 V, double door type for DB for fixing MCB’s, isolators etc., having IP-43 protection with magnetic locking system, including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing surface , IN REPLACEMENT, complete all as specified |
| 122 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified. |
| 123 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp complete all as specified. |
| 124 | LED bulb 9 / 10watt B-22 Cap, highly efficient complete all as directed. |
| 125 | Surface mounted Environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 20 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt, IN REPLACEMENT, completeMAKE: Havells Cat No. LHEXBLP7PN1W018 or equivalent in makes mentioned in Appendix 'B' |
| 126 | Surface mounted environment friendly LED 10 W batten with polycarbonate housing & integrated electronic driver with THD<10% , lumen output should not be less than 90 lumens per watt, IN REPLACEMENT, completeMAKE: Havells Cat No. LHEXACP7INW010 or equivalent in makes mentioned in Appendix |
| 127 | LED 36 watt recessed 600mmx600mm luminaire Warm White which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid Ceiling including LED driver and connection with 3 core copper wire incl all accessories, IN REPLACEMENT complete all as specified |
| 128 | Exhaust fan steel body of size 300mm sweep with louvers, 900 RPM 230 volts single phase AC supply complete with bolt, nuts and washer and including PVC insulated and overall sheathed flexible 3 core 0.5 Sq.mm copper conductor cable from ceiling rose to exhaust fan for giving connection complete all as specified. |
| 129 | Ceiling fan 1200 mm sweep, 230 V with remote, blades & down rod, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated, brushless direct current motor (BLDC) and connecting up from ceiling rose or connector to fan, complete all as specified. |
| 130 | Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. |
| 131 | Brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed |
| 132 | Cutting the existing road straight by manual, depth and width not less than 1 metre below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 using 20mm graded aggregate stone complete all as specified. |
| 133 | Supply, laying, jointing & testing of LT XLPE insulated cable of sectional area 16 sqmm 4 core screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including taking down existing cable, complete all as specified |
| 134 | Steel tubes 40mm bore ‘light grade’, with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc including taking down existing pipe complete all as specified |
| 135 | Earthing to panel with galvanised steel plate electrode 600 mm x 600 mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal groung level) with top edge of earth lead wire 4.0 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule pt-I 2009, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. IN REPLACEMENT, complete all as specified. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. |
| 136 | Demolition and Dismantling work |
| 137 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified. |
| 138 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified. |
| 139 | Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 140 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 141 | Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 142 | Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified |
| 143 | Demolition of cement concrete of any description and in any position not otherwise specifically provided all as specified. |
| 144 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified. |
| 145 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified. |
| 146 | Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified. |
| 147 | Dismantling wrought iron or mild steel work of any description, complete all as specified. |
| 148 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, embedded in natural ground etc. complete all as specified. |
| 149 | Dismantlig brick tiles in roof laid dry and pointed in cement mortar all as specified. |
| 150 | Dismantling existing cast iron soil vent pipe of any size internal dia, fixed to wall/floor/rain water laid in trenchs incl all fitting & accessories |
| 151 | Dismantling fencing wire mesh, any type complete all as specified. |
| 152 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 153 | Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 154 | Taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connection from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified & directed. |
| 155 | Note : Amount of credit for retrieved materials is mentioned in Sch of credit of tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender