Tender For Repair And Renovation Works To Classrooms Al-002 And Al-003, Ground Floor, Electrical Engineering Department, Vjti, Matunga, Mumbai.
Tender Value
22.67 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
14 days left
EMD
22675
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Renovation Works To Classrooms Al-002 And Al-003, Ground Floor, Electrical Engineering Department, Vjti, Matunga, Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Deployment of Mazdoor – Unskilled Heavy Male Labour for Shifting of Materials (scrap, wooden benches, debris, cleaning etc.) as directed. |
| 2 | Removing doors and windows with frames and stacking thematerials as directed with all leads, lifts etc. complete. (Lead up to 100 meters) |
| 3 | Removing cement tiles or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (Lead Upto 100 meters) |
| 4 | Scraping the old paint from the plastered internal surface using a dust-free vacuum paint scraper, followed by coating the entire surface with a mixture of whiting or glue and linseed oil, including the provision of scaffolding, as directed. (The scraping of old paint should be done until the neeru finish of the plaster is achieved.) Lead and Lift upto 100 meters etc. Complete. |
| 5 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 100 metres or spreading in the compound and cleaning the site etc. complete. |
| 6 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. (Lead upto 100 meters) |
| 7 | Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. |
| 8 | Removing the exisitng oil paint from doors and windows surfaces upto the original wood surface by using flame and grinder etc. complete. The Surfaces should got approved from Engineer in charge before applying melamine polish. |
| 9 | Providing antitermite treatment to the sides of flooring of the existing building as per I.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percent of chlorodane emulsion concentrate at the rate of 50 ml per hole and sealing by filling putty etc. complete |
| 10 | Removal, collection, and disposal of debris/ rubbish/ malba from the site, including loading, unloading, transportation, and dumping at approved location as per muncial rules, with all tools, and equipment etc. complete as directed. |
| 11 | Treating rising dampness (Capillary action) in masonry walls using a low pressure impulse pump, and injecting an alkali, siliconate, silicone or stearate fluid into holes of 16 mm diameter with 200 mm length drilled in the walls at every 9 inches. Fill the holes with Polymer modified mortar. Finish the mortar joints between the bricks etc. complete |
| 12 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals \ (Dr.Fixit Pidifin 2k) for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete |
| 13 | Providing waterproof plaster12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete (Dr. Fixit LW+ @200 ml per 50 kg bag of cement). |
| 14 | Chipping /removing loose concrete upto reinforcement bars,without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc complete. |
| 15 | Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush. After detachment of loose scales reddish rusted surface is still left exposed, this has to be retreated or as per approved manufacturers specifications. |
| 16 | Bond Coat: Providing & applying One coat of structural grade epoxy bond coat by brush conforming to ASTM-C-882 87 to the prepared concrete surface to be repaired / strengthened. This is applied prior to the application of polymer repair mortar / epoxy mortar / Microconcrete to have monolithic action between old concrete Surface |
| 17 | Repair with Polymer Modified Mortar (PMM): Repairs to the deteriorated / damaged areas of RCC elements in the structure shall be carried out by using powder Polymer Modified repair mortar. The polymer modified mortar is applied when the epoxy bonding coat is still tacky. In one application 25 mm thickness shall be built.Subsequent layer shall be built with one bond coat of Polymer modified cement slurry. The polymer modified repair mortar shall be mixed, applied and cured as per technical Specifications. |
| 18 | Repairing to the existing RCC structural members (vertical or horizontal) using ready mix Micro Concrete of approved brand where the thickness of repair is more than 30 mm and upto 115 mm. It can be used for carrying out extensive repairs to beams, columns and other structural elements, repairing of structural members subjected to repetitive loading & for Jacketing of beams, columns and other structural elements for strengthening. |
| 19 | Providing and fixing in position steel bars reinforcement of various diameters for R.C.C. pile, pile caps, footings,raft, retainingwall, shear wall, lift wall, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, coping, fins, arches, etc. as per detailed designs, drawings and bar bending schedules, including straightening, cutting, bending, hooking the bars, binding with wires or tack welding, supporting as required etc. all complete at all levels. Thermo-Mechanically Treated steel bars. (Fe500 D) |
| 20 | Providing and applying plaster / wall punning with plaster of paris ( with plasterof paris material) in 10 to 13 millimeter thickness to previously plastered surface / oron newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 21 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete |
| 22 | Centering and Wooden ( Marine plywood) shuttering including strutting, propping, beacing, bolting, wedging, casting, striking, etc. and removal of form for : (Note: props shall consist of well designed adequately braced ) Suspended floors, roofs, landings, balconies and access platform, Lintels, beams, plinth beams, girders, and cantilevers beam, Stairs (waist slab), folded slab, inclined slab etc. |
| 23 | Providing and laying vitrified mirror/glossy/Matte finish tiles of size 590 mm to 605 mm x 590 mm to 605 mm with a thickness of 8 to 10 mm, conforming to IS 15622:2006 (Group B1A) from an approved make, shade, and pattern, for dado and skirting in the required positions. The tiles shall be fixed in 1:4 cement mortar, including neat cement float, filling of joints, curing, cleaning, and all related work, etc., complete. Groove shall be filled with grout of approved shade (Brands like Laticrete etc.) as dicected by the Engineer-in-charge. etc. complete. |
| 24 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete Brands Like Kajaria, Johnson or Similar etc. Groove shall be filled with grout of approved shade (Brands like Laticrete etc.) as dicected by the Engineer-in-charge. etc. complete. |
| 25 | Providing and fixing machine cut mirror polished 16 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges for door frame/ dado/window boxing etc.On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. etc. complete. One side polish |
| 26 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc.complete. |
| 27 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 28 | Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. (Brands such as Asian Paints, Dulux Paints, Nerolac, Berger, Royal, or equivalent make.) |
| 29 | Providing and applying a priming coat over new/old steel and other metal surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter. The surface shall be scoured with wire brushes, fine steel wool, scrapers, and sandpaper, with scaffolding as required, etc. Complete. |
| 30 | Providing and applying two coats of synthetic enamel paint of approved color to new/old structural steel work and woodwork in buildings, including scaffolding if necessary, cleaning, and preparing the surface (excluding primer coat). etc. Complete. (Brands such as Asian Paints, Dulux Paints, Nerolac, Berger, Royal, or equivalent make.) |
| 31 | Providing and applying waterproof melamine polish of the required finish to the woodwork by spray machine, including knotting and preparing an even surface by scraping, applying French polish, scaffolding if required, etc., complete.Note: The work is to be executed only with prior approval from the Superintending Engineer. (Brands such as Asian Paints, MRF Melamine or equivalent.) etc. complete. |
| 32 | Providing anti-termite treatment to the wooden frames of doors and windows of the existing building as per I.S. 6313 (Part-III), by drilling 6 mm dia. holes at the four corners on one side and the four corners on the other side, at a downward angle of approximately 45 degrees at the junction of the woodwork and masonry. Injecting 150 ml of Chlorodane 5% W.C. into each hole and sealing with putty, etc., complete, with a 2-year guarantee on bond paper. |
| 33 | Providing second-class burnt brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in the superstructure, including striking joints, raking out joints, watering, scaffolding, and all related work, etc., complete. |
| 34 | Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m at 60 cms center center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete. |
| 35 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc.all complete. |
| 36 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambe red frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm(+-0.2mm), duly reinforced with G.I. section 1.5mm, wherever required. uPVC window & door profile shall be made in India&shall conform to BSEN12608 and other standards asmentioned below: S.No.Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256-more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM/ TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided.Window /Door will be fixed to the wall with 100 mm long and 8 mm dia.Fastener sand complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47 mm |
| 37 | Providing & fixing premium quality Roller blinds with Solar protection of high tenacity Polyester Yarn with PVC coating & Aluminium Backing and fungi static treatment etc.complete and should block the light flux & offer elimination ofglare and sunlight /radiance Fabric shall have visible light & solar properties & greengaurd (gold) Indoor Air quality & children & school certified.Fabric composition - 39% Polyester / 61% PVC with alumium backing.Weight - 290 g/sq.m (+/- 5%)Thickness - 0.32 mm (+/- 5%)Fabric openness factor - 3%Tensile strength (warp / weft) - 160/170 daN/5cmTearing Strength (warp/weft) - 11/13 daNBacking - Aluminium backing.Fungi static treatment - Degree 0 Excellent (ENISO 846-A)Fire retardancy: B-s2,d0/EN 13501-1, class A/ASTM E84. |
| 38 | Providing and fixing fully glazed double leaf window shutter with openable fanlight including Country cut teakwood 25mm thick style and rails with plain /obscured glass panels 5mm thick as per drawing or as directed by the Engineer in charge with stainless steel fixtures and fastening and finishing the woodwork with oil painting three coats etc. complete. |
| 39 | Repairing existing teak wood doors including necessary dismantling, replacement/repair of damaged wooden members, fixing of new tower bolts, handles, glass panes, screws, fittings and fixtures etc. complete as directed by the Engineer-in-Charge. |
| 40 | Providing and fixing SS Invisible Safety Grill to windows, complete with SS wire ropes, brackets, anchors, tensioners, fasteners and all accessories, including labour and fixing, complete as directed. |
| 41 | Point wiring for light/bell/exhaust fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 42 | Secondary point wiring for additional light/bell point in min 20mm PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification no. WG-PW/SW |
| 43 | Point wiring for ceiling fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 44 | Point wiring for independent plug in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 45 | Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WGPW/ CW |
| 46 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 47 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 48 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module complete. |
| 49 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 8 module complete. |
| 50 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 16/18 module complete. |
| 51 | Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete. |
| 52 | Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW (For AC Circuit) |
| 53 | Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW (For AC Circuit) |
| 54 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. |
| 55 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. |
| 56 | Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated shortcircuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCBO. |
| 57 | Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 58 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 59 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected inposition as per specification no. FG-FN/CF |
| 60 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. |
| 61 | Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. |
| 62 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. |
| 63 | Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 64 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC |
| 65 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete as per specification no. AP/AC-CP For Liquid Line -9.52 mm OD |
| 66 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete as per specification no. AP/AC-CPFor Gas Line -15.88 mm OD |
| 67 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater /AC system. |
| 68 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater /AC system. |
| 69 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/32A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on provided angle iron/GI frame. |
| 70 | Carrying out core cutting of size 3\\" to 5\\" dia x 15\\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender