Housing Urban and Rular Development Government Departments Closing in 16 days TDR #58421224

Tender For Augmentation And Repair Or Renovation Works Related To Compound Lighting Installations Including Street Light, Main Entrance Light And Boundary Wall Etc At Eije Institute Premises , Howrah.

Issued by Government Departments · Howrah, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Nov 2026
16 days left
EMD
6750
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation And Repair Or Renovation Works Related To Compound Lighting Installations Including Street Light, Main Entrance Light And Boundary Wall Etc At Eije Institute Premises , Howrah.

BOQ

Name of Work:- Augmentation and repair or renovation works related to compound lighting installations including street light, main entrance light and boundary wall etc at EIJE institute premises , Howrah.
Sl. No. Item Description
1Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make:Polycab/Havells/RR Kabel/ Gloster) 2 Core 10 Sqmm.
2Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth to as below and mending good the damages to original finish incl. removing the rubbish. 2 CORE 10 SQMM
3Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 2 core 10 sqmm.
5Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 Core 10 sqmm (22MM)
6Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia.
7Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. [STREET LIGHTS CONTROL]
8Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [STREET LIGHTS CONTROL]
9Supply and Fixing SMC Junction Boxes of dimention (250x200x100)mm with IP 67 protection (Sintex / Hensel )make for compound light. With 4pole 32A terminal stud and 6A 10KA C curve SP MCB (make-Legrand/ABB/Siemens/L&T) [FOR STREET LIGHTS].
10LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10%[COLLEGE CAMPUS ON POLE]
11as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all
12espect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 90 watt.
13Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm. [LOOP BOX TO FITTING CONNECTION].
14Dismantling the existing damage wire, cable, lights , pole etc.
15S & F 50mm dia medium gauge 1.5mt long detachable type GI single arm bracket including carrying charges suitable for pole head.The arm bracket shall be properly welded with 15mm thick stifner plate of pole sleeve for strengthing incl. Properly fixing arrangement with the pole by bolt,nuts and washer as per direction of EIC.
16LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%
17as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of
18relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 250 watt. [GATE LIGHT].
19Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
20Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
21Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 6 swg.
22Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58421224
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 23-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Augmentation And Repair Or Renovation Works Related To Compound Lighting Installations Including Street Light, Main Entrance Light And Boundary Wall Etc At Eije Institute Premises , Howrah.
Basic Detail
Tender No WBPWD/AE/HESD/e-NIQ-41/2026-27
Bidding Type Tender
Location
City Howrah
State West Bengal
Key Dates
Publish Date 06 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 6750
Exemption Not Available
Document List
BOQ_5205504.xls
d7901165-bd45-43d7-89df-4412818f77b5.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5205504.xls

html

d7901165-bd45-43d7-89df-4412818f77b5.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender