Tender For Provn Of Oxygen Charging Bay At 20 Wing And Provn Of Misc E/M And B/R Works In 24 P&S At Af Station Bagdogra Under Ge (Af) Bagdogra
Tender Value
39.40 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
21 days left
EMD
78800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Oxygen Charging Bay At 20 Wing And Provn Of Misc E/M And B/R Works In 24 P&S At Af Station Bagdogra Under Ge (Af) Bagdogra
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing n exc15 cm deep and getting out any type of soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in soft/loose soil complete all as specified and directed. |
| 3 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soft/loose soil etc complete all as specified and directed. |
| 5 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 6 | M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in foundation, footing, foundation beam, plinth beam, base for columns, etc. complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately. |
| 7 | M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate)as in columns, etc. complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately. |
| 8 | M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in beams, cantilevers, bressumm ers, lintels over 1.5m span complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately. |
| 9 | M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in roof beam and gable beam complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately. |
| 10 | M&L for RCC 1:2:4 type B-1 (Nominal mix) using 20 mm graded stone aggregates as in Chajjas complete all as specified and directed. Note: Reinforcement shall be measured and paid separately. |
| 11 | M&L for RCC 1:2:4 type B-1 (Nominal mix) using 20 mm graded stone aggregates as in Slab supported on wall, beam and column in floor, roof, complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately) |
| 12 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter (rough finished surface) complete all as specified and directed. |
| 13 | M&L for formwork to sides of pillar, post, strut, piers, column and stanchions (square/rectangular /polygonal) rough finished surface complete all as specified and directed. |
| 14 | M&L for formworkto soffits of suspended slabs such as roof slab, floor, slab, landing and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and directed. |
| 15 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors in rough finished flat surfaces and etc complete all as specified and directed. |
| 16 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide (rough finished surface) complete all as specified and directed. |
| 17 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 18 | All as per item No. 17 above, but 5 mm dia & over upto & including 10 mm dia in stirrups, spacers and binders, complete all as specified and directed. |
| 19 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 20 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft and loose soil complete all as specified and directed. |
| 21 | M&L cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in foundations, filling and mass concrete in post, pillars complete all as specified and directed. |
| 22 | M&L Steel work in tubular/angle trusses or rectangular/ square hollow section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 23 | M&L Plates (plain or chequered square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 24 | M&L Bands, straps, supports or stays for rainwater, ventilating pipe, including bolts, if required hooks (stay) heavy for large gates, hook, holdfast and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, flat iron, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 25 | M&L preparation of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 26 | M&L pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated/trapezoidal steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 27 | M&L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof ridge, valley gutter, covering/cladding to wall fixed with self tapping screws or \\"J\\" hook complete all as specified and directed. |
| 28 | M&L anodised aluminium snap grid frame work for false ceiling of grid size 605X605 mm panel with hangers 4 mm bore. G.I. (upto 1200mm length) adjusting level fixed to roof slabs/roof truss by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm bore. 40mm long complete as per manufacturer's instructions including fixing of nut, bolt and clamps with the help of drilling machine complete all as specified and directed. |
| 29 | M&L for non-asbestos, fibre cement reinforced board high pressure steam cured (Design-Oceanic or approved),pre painted seif finished white/ivory colour, 4mm thick size (595mmx595mm) board fixed or laid/inserted to aluminium/M.S frame work with screws if required all as per specification and drawing or all as per manufacture's instructions complete all as specified and directed. Note : Aluminium snap grid frame work shall be measured and paid separately) |
| 30 | M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and fair (without using extra cement) complete all as specified and directed. |
| 31 | M&L for 15 mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer's instruction and complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 32 | M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two or more coat distempering with putty 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre over a coat of primer, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed. |
| 33 | M&L preparation of newly plastered surfaces of wall and applying two coats of Weather proof Exterior Emulsion paint for camouflage design over a coat of suitable primer on walls incl necessary scaffolding complete all as specified and directed. |
| 34 | M&L for Hardcore (broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 35 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 36 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified and directed. |
| 37 | M&L for 25 mm thick Cement concrete type B-0 1:2:4 (12.5 mm graded aggregate) as in sub floors etc incl finishing the surface even & rough to receive screeding complete all as specified and directed. |
| 38 | M & L Machine cut kota stone slab flooring 20 -25 mm thick over cement screed based laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20 mm thick screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified including rubbing and polish complete all as specified and directed. |
| 39 | M & L Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 10mm thick rendering in CM 1:4 etc. set and jointed in neat cement slurry and pointed including rubbing and polish complete all as specified and directed. |
| 40 | M&L for Granite (of any type) tiles15-18 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15mm thick screed bed in CM 1:6, including grinding and polishing complete all as specified and directed. |
| 41 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, including sealing compound grade A complete all as specified and directed. |
| 42 | M&L powder coated anodized Aluminum frame for doors, windows ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 43 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium fittings such as handles - 02 Nos, 100mm long hinges - 03 Nos, sliding bolt - 01 Nos, tower bolt - 02 Nos in each door, powder coated aluminium snap beading and rubber gasket, screws etc complete all as specified and directed. Note: Glass shall be measured separately. |
| 44 | M&L powder coated aluminium sliding window shutters with frames (consisting of 02 Nos glazed shutters and 01 No gauze shutter) Series -D (25mm), 3 track sliding shutters, duly fitted with neoprene beading, glazing clips, locking device, heat absorbing glass 5.5 mm nominal thickness in glazed shutters, stainless steel wire mesh of 0.254mm nominal dia of wire and 0.95 mm average width of aperture in gauzed shutter and powder coated aluminum grill 4mm dia, 75 x 75mm aperture fixed with standard aluminum beading fixed in outer portion of the chowkat complete all as specified and directed. |
| 45 | M&L for 4 mm thick sheet glass ordinary quality and glazing each pane fixed with neopune rubber gasket in aluminium frame work complete all as specified and directed. |
| 46 | M&L pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete size of frame 105mm X 60mm complete all as specified and directed. |
| 47 | M&L for PCC type C1, 1:3:6 (using 20 mm graded aggregate) for holdfast blocks complete all as specified and directed. |
| 48 | M&L factory made 35mm thick flush shutters solid core construction with block board core and plywood face panel commercial type on both faces complete all as specified and directed. |
| 49 | M & L for Preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer complete all as specified and directed. |
| 50 | M&L 25 mm outer dia medium weight pipe and end clamps with ornamental knobs for sides made out of stainless steel 304 grade, curtain rods to fixed to walls complete all as specified. |
| 51 | S&F aluminium (extruded section body) door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters 851 mm to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 52 | Taking down chowkhat or frame with shutters without taking of shutters from frames exc 1.5 Sqm but not exc 4.00 sqm each incl making good disturbed portion including removing to store complete all as specified and directed. |
| 53 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 54 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium fittings such as handles - 02 Nos, 100mm long hinge - 03 Nos, sliding bolt - 01 Nos, tower bolt - 02 Nos in each door, powder coated aluminium snap beading and rubber gasket, screws etc complete all as specified and directed. Note: Glass shall be measured separately. |
| 55 | M&L for 5 mm thick sheet glass ordinary quality and glazing each pane fixed with neopune rubber gasket in aluminium frame work complete all as specified and directed. |
| 56 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 57 | M&L for joint free colour glazed ceramic wall tiles of size 450x300x6-7mm thick on vertical surfaces laid over and including for rendering 10mm thick in CM (1:4) on vertical surface of wall cement screed bet set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 58 | Surface Excavation in any type of soil n exc 30 cm deep and averaging 15 cm deep and getting out any type of soil complete all as specified and directed. |
| 59 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 complete all as specified and directed. |
| 60 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified and directed. |
| 61 | M & L for sand cushioning to receive interlocking tiles incl spreading, levelling in layers complete all as specified and directed. |
| 62 | M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey Cement and pigment complete all as specified and directed. |
| 63 | M&L for designed, pre painted coloured chequered cement concrete tiles 300x300x25mm thick with grey cement and pigments set, jointed & pointed in neat cement slurry, laid over 20mm thick screed bed in CM 1:6 finished with pigments match the shade of tiles complete all as specified and directed. |
| 64 | Removing excavated materials (Soils) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 65 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping/kerb stone etc complete all as specified and directed. |
| 66 | M& L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including In stove enamelled steel conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, columns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and complete all as specified and directed for the following:- (a) One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 67 | S&F flame proof Exhaust fan 15 inch single phase complete all as specified and directed. |
| 68 | M & L for sutable hole in exixting wall for fixing of Exhaust fan and distrub surface will be plastred and painted as existing complete all as specified and directed. |
| 69 | S&F in replacement of LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 70 | S&F in replacement of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 71 | M& L for Point wiring with 2.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including In stove enamelled steel conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and complete all as specified and directed. |
| 72 | S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. |
| 73 | Supply and laying in trenches service cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 Volts grade with stranded aluminium conductor of16 Sqmm 2 Core size complete all as specified and directed. |
| 74 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc.and getting out for soft/loose soil complete all as specified and directed. |
| 75 | Supply and lay GI tubes light grade with connected fittings laid in trenches/ wall/pole for protection to UG cables of size 32 mm dia complete all as specified and directed. |
| 76 | M&L for cushioning for protection of cable using dry river sand, free from particles complete all as specified and directed. |
| 77 | M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks complete all as specified and directed. |
| 78 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as specified and directed. |
| 79 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 80 | M& L for Point wiring with 4.0 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including In stove enamelled steel conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, columns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and complete all as specified and directed. |
| 81 | S&F in replacement MCB SPN/DP 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 82 | S&F in replacement MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 83 | S&F in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish complete all as specified and directed. |
| 84 | Supply, Install, testing and commissioning of flame proof window type AC 1.5 TR ,18000 BTU/Hr Reciprocating single phase with Flame proof design complying with IS/IEC 600079 standards weather-proof (IP-65) construction suitable for outdoor environments available for hazardous areas Zone-1&2 and compacted low vibration design with optimized air distribution options for GI (power coated) ss304 construction scroll or reciprocating compressor options for enhanced energy efficiency R407C/R134 refrigerant compatible eco-friendly and efficient custom voltage and single phase 230V optional alarm integration for compressor trip over temperature or system fault CIMFR certified for complete compliance with hazardous area requirements Cat Part No PFC-2W18R1PO complete all as specified and directed. |
| 85 | M&L Chemical Earthing Complete with copper earth plate electrode 90cm x 60cm x 5mm thick buried directly in ground earth pit not less than 5.0 M deep below normal ground level and complete size of pit 1.6 M X1.6 M X 5.0 M earth plate connected to copper strip of size 50 x 6 mm by brazing only ,earth strip protected with light grade GI Pipe 80 mm bore from copper earth plate electrode and upto and including the earth test point made of gunmetal Phosphorous bronze of size 75x75x25 mm including 25 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh. Alternate five layers of charcoal (250 KG ) & salt crystal (200 KG) and top two inch layers with BFC (100 KG) including excavation in strata ,refilling with black cotton soil above the Back filling compound and removal of the excavated soil and depositing at the place where directed,(,PCC Pit in PCC ( 1:3:6 ) type C1 using 20 mm graded stone aggregate , RCC M ) 40 mm thick in RCC ( 1:2:4 ) type B 1 using 20 mm grade aggregate reinforced with 8mm dia TMT bars @ 7.5 mm c/c both ways including MS angle iron frame of 40 X40X 3 mm etc, watering the earth pit to achieve earth resistance not more than 01 OHM incl testing all as directed and spfd. ( Note For item No 1 to 4: Earth conductor from earth plate to equipment upto 7.5 M length deemed to be included in the rate quoted by the contractor and beyond 7.5 M will be measured and paid under the respective item of the schedule. Note 2 : Cost of excavation, returning and filling, earth work required based on the nature of eath pit for satisfactory completion of job deemed to be inclusive in the unit rate.) |
| 86 | M&L Air termination, single pointed copper rod 12mm dia 300mm long complete all as specified and directed. |
| 87 | M&L test terminal block made of gun metal for phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25 mm long hex. head screw complete all as specified and directed. |
| 88 | M&L Copper strip of 20 x 3.15mm with saddle & fixing screw etc for roof conductor and down conductor above ground complete all as specified and directed. |
| 89 | S&F porcelain insulator of size 65X65X40 mm complete with one number GI stud bolts including nut & bolts etc complete all as specified and directed. |
| 90 | M&L Earthing of machinery/equipment installed at power house/ substation, using 20 x 3 mm Copper strip and copper plate of size 600 x 600 x 3.15 mm as earth electrode complete all as specified and directed. |
| 91 | M & L GI tubing of 20 mm bore light grade with all fitting fixed to wall/ceiling or laid on floor complete all as specified and directed. |
| 92 | M&L for PCC (1:2:4) type B-I coping with 20 mm graded aggregate for grouting, finished even and smooth without using extra cement complete all as specified and directed. |
| 93 | M& L for Point wiring with 4.0 Sqmm (36/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing capping/ PVC Conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, columns/ beams alongwith 4.0 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and complete all as specified and directed for AC Point. Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 94 | S&F sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed. Please Enable Macros to View BoQ information |
| 95 | S&F sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender