Tender For Construction Of Stop Over Facilities For Trainees & Researchers (G+2) At Balugaon During Fy 2026-27 (Composite)
Tender Value
1.30 Crore
Estimated cost
Bid Submission
26 Nov 2026
3 days left
EMD
1.30 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Stop Over Facilities For Trainees & Researchers (G+2) At Balugaon During Fy 2026-27 (Composite)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead. |
| 2 | (a)First Floor |
| 3 | (b)Second Floor |
| 4 | Dismantling brick or stone masonry in lime or cement mortar under 3.0M height including stacking the usefull materials for reuse and removing the debris within 50 M lead. |
| 5 | (a)Ground Floor |
| 6 | (b)First Floor |
| 7 | (c)Second Floor |
| 8 | Dismantling and removing RCC Columns, beams, slabs, staircase, landing, lintel, etc. including stacking the usefull materials for reuse and removing the debris within 50 M lead. |
| 9 | (a)Ground Floor |
| 10 | (b)First Floor |
| 11 | (c)Second Floor |
| 12 | Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 13 | (a)Ground Floor |
| 14 | Construction of Single under reamed bored compaction pile foundation of 300mm dia and 7.00 mtr long with RCC M-25 grade using 20mm and down grade black hard granite (Crusher broken) stone chips including cost of boring but excluding cost of M.S./Tor steel but including the cost of labour, conveyance, taxes, royalty, etc. all complete as per the direction of engineer-in-charge. |
| 15 | (a)Ground Floor |
| 16 | Earth work in all kind of soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
| 17 | (a)Ground Floor |
| 18 | Supplying and filling in foundation and plinth with sand including watering and ramming, poking and compacting including cost, conveyance, royalties, taxes of the materials and cost of all labour, labour cess, T&P etc. required for the work complete as directed by the engineer-in-charge. |
| 19 | (a)Ground Floor |
| 20 | Providing and laying Plain Cement Concrete of proportion (1:3:6) using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including the cost of all materials, cost of labour, conveyance, taxes, royalties, loading, unloading, shuttering, centering, curing, labour cess, T&P, etc. all complete as per the direction of engineer-in-charge. |
| 21 | (a)Ground Floor |
| 22 | Providing, lifting, hoisting and laying in Position Reinforced Cement Concrete of M-25 grade including cost of Centering and shuttering using 20mm and down grade size black hard granite (Crusher Broken) chips of approved quality from approved quary including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, T&P, royalty, labour cess, all complete as per the direction of Engineer-in-charge but excluding the cost of steel reinforcement. |
| 23 | R.C.C. Foundation and Footing Bases of Columns Mass Concrete Pre-Cast Slab etc. |
| 24 | (a)Ground Floor |
| 25 | R.C.C. Grade Beams |
| 26 | (a)Ground Floor |
| 27 | R.C.C. Columns & Roof Beams |
| 28 | (a)Ground Floor |
| 29 | (b)First Floor |
| 30 | (c)Second Floor |
| 31 | (d)Terrace Floor |
| 32 | R.C.C. Lintels |
| 33 | (a)Ground Floor |
| 34 | (b)First Floor |
| 35 | (c)Second Floor |
| 36 | (d)Terrace Floor |
| 37 | R.C.C. Chajja |
| 38 | (a)Ground Floor |
| 39 | (b)First Floor |
| 40 | (c)Second Floor |
| 41 | (d)Terrace Floor |
| 42 | R.C.C. Shelve |
| 43 | (a)Ground Floor |
| 44 | (b)First Floor |
| 45 | (c)Second Floor |
| 46 | R.C.C. Stair Case |
| 47 | (a)Ground Floor |
| 48 | (b)First Floor |
| 49 | (c)Second Floor |
| 50 | R.C.C. Floor and Roof Slab, Landing, Balconies, Projecting Sun Shades and Chajjas up to 4.3 Mtr. Height. |
| 51 | (a)Ground Floor |
| 52 | (b)First Floor |
| 53 | (c)Second Floor |
| 54 | (d)Terrace Floor |
| 55 | Cutting, Straightening, coiled or bent up MS Road of TOR steel using SAIL/RINL/TATA/JINDAL/SHYAM Steel including bending, binding,welding and joining if necessary and tying the grills and placing in position as required for RCC work and hoisting, lowering laying icluding cost, conveyance, taxes of MS rod or TOR steel and binding wire of 18 to 20 gauge and labour required for the work for bending,binding and tying the grills etc. complete. |
| 56 | (a)Ground Floor |
| 57 | (b)First Floor |
| 58 | (c)Second Floor |
| 59 | (d)Terrace Floor |
| 60 | Providing Fly-Ash Brick masonry work in F&P using Fly-Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6) including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer-in-charge. |
| 61 | (a)Ground Floor |
| 62 | Providing Fly-Ash Brick masonry work in Superstructure using Fly-Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6) including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer-in-charge. |
| 63 | (a)Ground Floor |
| 64 | (b)First Floor |
| 65 | (c)Second Floor |
| 66 | (d)Terrace Floor |
| 67 | Providing Fly-Ash Brick masonry work in Superstructure using Fly-Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:4) with provision for two no.s of 6 mm dia after each 4th layer. including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer-in-charge. |
| 68 | (a)Ground Floor |
| 69 | (b)First Floor |
| 70 | (c)Second Floor |
| 71 | Providing 16 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer-in-charge. |
| 72 | (a)Ground Floor |
| 73 | (b)First Floor |
| 74 | (c)Second Floor |
| 75 | (d)Terrace Floor |
| 76 | Providing 12 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer-in-charge. |
| 77 | (a)Ground Floor |
| 78 | (b)First Floor |
| 79 | (c)Second Floor |
| 80 | (d)Terrace Floor |
| 81 | Providing 12mm thick Cement Plaster in Cement Mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. |
| 82 | (a)Ground Floor |
| 83 | (b)First Floor |
| 84 | (c)Second Floor |
| 85 | Providing 6 mm thick cement plaster in cement mortar of (1:4) to RCC work including roughening, scraping, cleaning and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, cost of labour, conveyance, loading and unloading, all taxes and royalties, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge. |
| 86 | (a)Ground Floor |
| 87 | (b)First Floor |
| 88 | (c)Second Floor |
| 89 | (d)Terrace Floor |
| 90 | Providing and fixing ISI marked 35 mm thick flush door shutters with Frame conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete |
| 91 | (a)Ground Floor |
| 92 | (b)First Floor |
| 93 | (c)Second Floor |
| 94 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 95 | (a)Ground Floor |
| 96 | (b)First Floor |
| 97 | (c)Second Floor |
| 98 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. The sash will be fitted with 6mm reflective toughened glass of make - Saint gobain/ AIS/ Goldplus. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent including cost of all materials, labour, sundries , T&P etc. complete in all respect as per drawing and direction of Engineer-in-charge. |
| 99 | (a)Ground Floor |
| 100 | (b)First Floor |
| 101 | (c)Second Floor |
| 102 | (d)Terrace Floor |
| 103 | Supplying and installing UPVC- 3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58mmx32mm and sash dimension of 61mmx37mm for windows with corners fusion welded , fully reinfoeced with Galvanised steel of 1.2mm to 2mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/ AIS/ Goldplus. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent including cost of all materials, labour, sundries , T&P etc. complete in all respect as per drawing and direction of Engineer-in-charge. |
| 104 | (a)Ground Floor |
| 105 | (b)First Floor |
| 106 | (c)Second Floor |
| 107 | (d)Terrace Floor |
| 108 | Supplying, fitting and fixing of G.I. grills in Door /windows made out of MS flat confirming to IS : 2062/2006 painted with red oxide primer including screws as required including the cost of all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. |
| 109 | (a)Ground Floor |
| 110 | (b)First Floor |
| 111 | (c)Second Floor |
| 112 | (d)Terrace Floor |
| 113 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge. |
| 114 | (a)Ground Floor |
| 115 | (b)First Floor |
| 116 | (c)Second Floor |
| 117 | Supplying, fitting and fixing double charged Vitrified Tiles in floors of size 600mm x 600mm (Plain/Ivory) of approved make confirming to IS:13755 laid on 20mm thick cement mortar (1:4) (1 cement : 4 Course Sand) and filling joints with white cement of approved quality including cost, conveyance, taxes, cost of all labour, labour cess, etc. all complete. |
| 118 | (a)Ground Floor |
| 119 | (b)First Floor |
| 120 | (c)Second Floor |
| 121 | Supplying, fitting and fixing vitrified tiles in dados, skirting and risers of steps on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with colouring pigments to match the colour and shade including the cost of washing, polishing, cost of materials, cost of all labour, conveyance, taxes, loading & unloading, T&P, watering and curing etc. complete. |
| 122 | (a)Ground Floor |
| 123 | (b)First Floor |
| 124 | (c)Second Floor |
| 125 | Supplying, fitting and fixing of 20mm thick granite slab in landing and floors laid on 20mm thick cement mortar (1:4) jointed white cement slurry and colouring pigment to match the shade including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc. complete as per the direction of the Engineer-in-Charge. |
| 126 | (a)Ground Floor |
| 127 | (b)First Floor |
| 128 | (c)Second Floor |
| 129 | (d)Terrace Floor |
| 130 | Supplying, fitting and fixing of 10 mm thick Granite stone in dados/skirting using granite stone of approved quality,colur and size over 12mm thick cement mortar (1:3) including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade,machine grinding, cleaning with oxalic acid, mirror polishing the surface including cost of all labour, materials, taxes, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. |
| 131 | (a)Ground Floor |
| 132 | (b)First Floor |
| 133 | (c)Second Floor |
| 134 | (d)Terrace Floor |
| 135 | Providing & laying granite stone flooring using 20 mm thick granite stone of approved quality, colour and size in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, taxes, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. |
| 136 | (a)Ground Floor |
| 137 | (b)First Floor |
| 138 | (c)Second Floor |
| 139 | Supplying, fitting and fixing Vitrified industrial floor tiles of appoved make and size (300mm x 300mm) confirming to IS:4457 laid on 20mm thick cement mortar (1:4) (1 cement : 4 Course Sand) and filling joints with white cement of approved quality including cost, conveyance, taxes, cost of all labour, labour cess, etc. as per the direction of Engineer-in-Charge. |
| 140 | (a)Ground Floor |
| 141 | Finishing the wall surface with Acrylic wall putty (water based) of approved make and finishing smooth even surface to receive painting including cost of all T&P and materials etc complete and as per specification and direction of the Engineer-in-Charge. |
| 142 | (a)Ground Floor |
| 143 | (b)First Floor |
| 144 | (c)Second Floor |
| 145 | (d)Terrace Floor |
| 146 | Providing & Painting with two coats of plastic emulsion paint of approved quality, make and shade over a coat of primer to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge. |
| 147 | (a)Ground Floor |
| 148 | (b)First Floor |
| 149 | (c)Second Floor |
| 150 | (d)Terrace Floor |
| 151 | Providing and painting with two coats of Weather Coat of approved quality, make and shade to give an even surface including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete. |
| 152 | (a)Ground Floor |
| 153 | (b)First Floor |
| 154 | (c)Second Floor |
| 155 | (d)Terrace Floor |
| 156 | Painting Two Coats of Synthetic Enamel Paint over a coat of Primer for Iron Works as per approved shade of approved quality, sand papering, polishing the surface including cost, conveyance, labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints are to be approved before procurement and use). |
| 157 | (a)Ground Floor |
| 158 | (b)First Floor |
| 159 | (c)Second Floor |
| 160 | (d)Terrace Floor |
| 161 | Proding fitting & fixing of false ceilling with Aluminium anodised T Section No. 3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\"x2'-0\\" suspended from ceilling etc. complete. (As per A.R. 237/3) |
| 162 | 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 163 | (a)Ground Floor |
| 164 | (b)First Floor |
| 165 | (c)Second Floor |
| 166 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. |
| 167 | (a)Ground Floor |
| 168 | (b)First Floor |
| 169 | (c)Second Floor |
| 170 | Providing and laying 25mm thick grading Concrete of proportion (1:2:2) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the engineer-in-charge. |
| 171 | (a)Second Floor |
| 172 | (b)Terrace Floor |
| 173 | ELECTRICAL PARTRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.N.B: None of the points/ switchboard shall be given inside the store room. All the lights are to be controlled from switchboards located outside the store room. No provision of ceiling fans are to be given in the store room.Provision of only smoke ventilation fans of suitable CFM are to be given in the store rooms. |
| 174 | Group-A |
| 175 | Group-B |
| 176 | Group-C |
| 177 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 178 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 179 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 180 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius-Next gen)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 181 | S/F of A.C. point consisting of 32 Amp single phase starter with all connection complete in all respect as per direction of engineer incharge (Make : Schneider/legrand/siemens) |
| 182 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 183 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 184 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 185 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 186 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 187 | Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 188 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 189 | Fan & indoor FixturesSupplying and fixing of Energy efficient surface /recess mounted round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 190 | Supplying and fixing of Energy efficient surface /recess mounted round shape 12 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1200 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 191 | SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K with 5 w/mtr @ 5Mtr Spool with Driver as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 192 | Supply and fixing of 6 Watt LED Spot light Surface/Consild fittings of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years make as approved etc as complete and as per the direction of E.I.C. |
| 193 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 194 | Supplying, Erection, Fixing, connection & testing of wall mounted 10W LED Bulkhead wall fitting of Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj. The luminaire should be Replacement Warranty will be 2 years |
| 195 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 196 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 197 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 198 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 199 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 200 | Panels, MDBs, DBs. MCBsMDB AT GF S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list. ON/OFF/TRIP indication for all the incoming and outgoing feeders.50X10MM Separate Aluminium Earth bus bar should be installed. Make of MCCB- ABB(Formula)/Siemens(3VA)/ SCHNEIDER (CVS)/ Legrand(DPX3) Make of MCB- ABB(SB 200)/Siemens(Betaguard) /SCHNEIDER(Acti 9 AN9)/Legrand(DX3) |
| 201 | In commer-1-01 number of 125A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS (FROM TRANSFORMER) |
| 202 | Busbar- AL bus bar Electrolytic busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 203 | Out going- 05 numbers of 63A 4P MCB 10kA, C series( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB-FORMULA) |
| 204 | Out going- 05 numbers of 40A 4P MCB 10kA, C series. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB-FORMULA) |
| 205 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 206 | (ii) Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) (SECURE/ Legrand ) for all the incomers |
| 207 | (ii) 1 set of SPD type 1+2 with 63 A 4 P Mcb, C series 10kA (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard)/ABB SB200 |
| 208 | DBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 209 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 3 years. |
| 210 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years. |
| 211 | Supply and fixing of 6 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITH ROOM ,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD ) Warranty on DB is 3 years. |
| 212 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD ) Warranty on DB is 3 years. |
| 213 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 214 | Supply and fixing of following rating double pole (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. |
| 215 | Supplying and fixing 25 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 216 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 217 | Supply and fixing of following rating double pole 40amp (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 218 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 219 | Cables, Cable Laying & TerminationSupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 220 | 3.5C X50 sqmm |
| 221 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand cushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 222 | TERMINATION OF CABLES Supply & Making end Termination with brass compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) |
| 223 | 3.5C X 50 sq. mm (35mm) |
| 224 | LIGHTNING PROTECTION:Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 225 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 226 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 227 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 228 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IECb 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 229 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 230 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 231 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 232 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 233 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 234 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 235 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 236 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 237 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 238 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 239 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 240 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 241 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 242 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 243 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 244 | EARTHING SYSTEM:S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 245 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 246 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 247 | SPLIT AC & OTHER ACCESSORIES:Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only (Category II)1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16) |
| 248 | REFRIGERANT PIPINGSupply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 249 | 1 TR to 3 TR high wall split A.C |
| 250 | FRAME WORKSupply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. |
| 251 | 1 TR to 3 TR high wall split A.C |
| 252 | DRAIN PIPINGSupply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. |
| 253 | 25mm nom. Dia pipe |
| 254 | CONTROL CABLESupply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 255 | UPSSupply, Installation, Testing and Commissioning of 5 KVA Online Ups with 30 min battery back up 12v/26ah-20no (min VAH : 8640) with Rack, interlink cable (Input 1Phase, output 1phase). UPS Make :Vertiv, APC, Neumeric VRLA Battery Make : Exide/Rocket/Quanta |
| 256 | (PH PORTION)Supplying all materials, labour, T&P and Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge (Supreme/Ashirvad/Oriplast) |
| 257 | In Ground floor 20mm dia C-PVC pipes |
| 258 | 25mm dia C-PVC pipes |
| 259 | In First Floor:20mm dia C-PVC pipes |
| 260 | 25mm dia C-PVC pipes |
| 261 | In Second Floor:20mm dia C-PVC pipes |
| 262 | 25mm dia C-PVC pipes |
| 263 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) |
| 264 | In Ground Floor;25mm PVC ASTM (SCH-80) Pipe |
| 265 | 32mm dia PVC ASTM Pipe |
| 266 | In 1st Floor:25mm dia PVC ASTM Pipe |
| 267 | 32mm dia PVC ASTM Pipe |
| 268 | In 2nd Floor:25mm dia PVC ASTM Pipe |
| 269 | 32mm dia PVC ASTM Pipe |
| 270 | In 3rd Floor:40mm dia PVC ASTM Pipe |
| 271 | 50mm dia PVC ASTM Pipe |
| 272 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
| 273 | In Ground Floor- 250mm thick wall |
| 274 | In 1st Floor:250mm thick wall |
| 275 | In 2nd Floor:250mm thick wall |
| 276 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. |
| 277 | In Ground. floor 250mm to 375mm thick wall. |
| 278 | In 1st Floor: |
| 279 | In 2nd Floor: |
| 280 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. |
| 281 | In Ground floor |
| 282 | In 1st Floor: |
| 283 | In 2nd Floor: |
| 284 | Supplying all materials, labour, T&P and fitting and fixing Brass/CP/CPVC/PVC fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
| 285 | 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN |
| 286 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN |
| 287 | 15mm dia CP angle stop cock (FLR-ACR-5053N) |
| 288 | 15mm dia CP SINK cock (Jaquar)FLR-CHR-5347N |
| 289 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 290 | HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565 |
| 291 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN |
| 292 | Shower Arm (SHA-CHR-477) |
| 293 | Over head shower 100mm dia round (OHS-CHR-1999) |
| 294 | 32mm dia CP Bottle trap (Jaquar make)-ALD -CHR-769L -300x190cm |
| 295 | 25mm dia CPVC ball Valve |
| 296 | 32mm dia CPVC ball Valve |
| 297 | 40mm dia CPVC ball Valve |
| 298 | 50mm dia CPVC ball Valve |
| 299 | 15mm dia CP Flange |
| 300 | 15mm dia CP Extention Nipple |
| 301 | 125mm CP grating |
| 302 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Second floor |
| 303 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. One piece commod(Hindware)ELEMENT Cat No.92084. |
| 304 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049+91115 |
| 305 | 550mmx400mm size wash hand basin with porcelain pedestal Parryware/ Hind ware /Neyser make ) |
| 306 | Supplying all materials, labour, T&P and fitting & fixing stainless steel AISI 304 (18/8) Library/Kitchen sink with drain board as per IS 13983 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink(Nirali/ Prayag) |
| 307 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) |
| 308 | 110mm dia U-PVC SWR pipe |
| 309 | 110mm U-PVC Door Tee |
| 310 | 110mm U-PVC Plain Tee |
| 311 | 110mm U-PVC Y Bend |
| 312 | 110mm U-PVC Plain Bend |
| 313 | 110mm U-PVC Door Bend |
| 314 | 110mm dia U-PVC 'P' trap |
| 315 | 110mm U-PVC Cowl. |
| 316 | 75mm dia U-PVC SWR pipe |
| 317 | 75mm U-PVC Plain Bend |
| 318 | 75mm U-PVC Door Bend |
| 319 | 50mm dia U-PVC class-IV pipes (Ashirbad /Sentinity/Supreeme) (For 2nos qtr) |
| 320 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
| 321 | Design Mirror (jaquar /cera) |
| 322 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge |
| 323 | 600mm Glass Shelf (Jaquar) ACN-CHR-1171N |
| 324 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 325 | 600mm long CP Towel Rail (Jaquar) ACN-CHR-1111NM |
| 326 | CP Towel Ring (Jaquar) ACN-CHR-1121N |
| 327 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP Soap Holder (Jaquar) ACN-CHR-1131N |
| 328 | CP double coat hook (Jaquar) ACN-CHR-1161N |
| 329 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Cooler-cum-Purifier of size (700x430x460mm ht) with water cooling capacity of 40 PPH with contineously flow with one faucet having option for cold water and normal water etc.with internal water supply connection complete as per direction of the Engineer-in-Charge |
| 330 | SS Stand for Aquaguard |
| 331 | Factory made Solid WPC door frame of size 95mmx55mm fabricated. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 332 | In Ground Floor:Door_D3_1X0.75X2.10)= |
| 333 | In First Floor:Door_D3_1X(0.75+2.10+2.10)= |
| 334 | In Second Floor:Door_D3_3X(0.75+2.10+2.10)= |
| 335 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 336 | In Ground Floor:Door_D3_1X0.75X2.10)= |
| 337 | In First Floor:Door_D3_1X0.75X2.10)= |
| 338 | In Second Floor:Door_D3_3X0.75X2.10)= |
| 339 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 340 | In Ground Floor: |
| 341 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. |
| 342 | In Ground Floor: |
| 343 | In First Floor |
| 344 | In Second Floor |
| 345 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1'-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
| 346 | In First Floor(Floor): |
| 347 | In Second Floor(Floor) |
| 348 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 349 | In Ground Floor: |
| 350 | In First Floor: |
| 351 | In Second Floor: |
| 352 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 60 cm. x 60 cm. Kajaria / Somany / Johnson to be pree approved . |
| 353 | In Ground Floor |
| 354 | In First Floor |
| 355 | In Second Floor |
| 356 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size. |
| 357 | In Ground Floor: |
| 358 | In First Floor: |
| 359 | In Second Floor: |
| 360 | Supplying and fitting-fixing of UPVC Louvers fixed window/ventilator made of (small series) frame 47x50mm & mullion 47x68 mm both having wall thickness of 1.9± 0.2mm and single glazing bead of appropriate dimension (Area upto 0.75sqm) etc.all complete as per direction of the Engineer-in-charge. |
| 361 | In Ground Floor:Ventilator_V1_1x0.60x0.60= |
| 362 | In First Floor:Ventilator_V1_1x0.60x0.60= |
| 363 | In 2nd. FloorVentilator_V1_3x0.60x0.60= |
| 364 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 365 | Gully trap chamber of size 250mmx250mm with R.C.C cover slab |
| 366 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 367 | Inspection chamber Inside size 760mmx760mmx460mm |
| 368 | RCPC Cover (18\\" round) |
| 369 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 370 | Man hole chamber Inside size 910mmx910mmx910mm |
| 371 | RCPC Cover (24\\" round) |
| 372 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 373 | RCC Rings Soakway pit 1.22m dia x 2.10m deep |
| 374 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 375 | 110mm dia u-pvc pipe alround concrete |
| 376 | 110mm dia u-pvc pipe alround concrete |
| 377 | Construction 1 nos 20 users RCC Septic tank |
| 378 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 379 | - do - with addl. Depth of 1.5 m |
| 380 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 381 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 382 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 383 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 384 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 385 | Roof Slab |
| 386 | For RCC wall |
| 387 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 388 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 389 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 390 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 391 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 392 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 393 | 110mm diameter U-PVC SWR pipe |
| 394 | 110mm dia U-PVC Plain shoe bend |
| 395 | 110mm dia U-PVC Cowl |
| 396 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 397 | Sinking of 200mmx150mm dia large Tube well(1 No.)Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore. |
| 398 | Labour for Drilling of 200 mm dia bore 0mtr to 120mtr |
| 399 | Labour for Drilling of 150 mm dia bore 0mtr to 120mtr |
| 400 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 401 | Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 45 mtrs |
| 402 | Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe |
| 403 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 404 | By DTH |
| 405 | Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department). |
| 406 | Submerssible Pump Set 1.5 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm. |
| 407 | DOL control panel |
| 408 | 2.50 sqmm cable |
| 409 | 32mm dia steel short piece |
| 410 | 32 mm dia HDPE Pipe |
| 411 | Bore Cap |
| 412 | C.I.Bracket |
| 413 | Rope Wire |
| 414 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 415 | Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender