Railways Local Bodies Closing in 9 days TDR #58418636

Tender For Design, Engineering, Supply, Installation, Testing And Commissioning Of Outdoor Led Landscape Illumination Systems Works Of Tau Devi Lal Park, Sector-22, Gurugram -Including 5 Years Maintenance-Cum-Defect Liability Period.

Issued by Local Bodies · Gurgaon, Haryana
Tender Value
1.55 Crore
Estimated cost
Bid Submission
17 Nov 2026
9 days left
EMD
3.11 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Design, Engineering, Supply, Installation, Testing And Commissioning Of Outdoor Led Landscape Illumination Systems Works Of Tau Devi Lal Park, Sector-22, Gurugram -Including 5 Years Maintenance-Cum-Defect Liability Period.

BOQ

Name of Work:- Design, engineering, supply, installation, testing and commissioning of outdoor LED landscape illumination systems works of Tau devi Lal Park, Sector-22, Gurugram -Including 5 years maintenance-cum-defect liability period.
Sl. No. Item Description
1SITC of feeder pillar Outdoor type with 125 Amp MCCB as incomer along with timer, contractor. Outgoing 7 Nos TPN63Amp/40 Amp
2SITC of IP65 3 way Junction box made of ABS lastic/Polycarbonate/MS sheet.
3As per HSR ITEM EL004 :- 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
4DHBVN 157 - Supply of LT XLPE armoured cable 4c x 16sqmm( DHBVN 78/DD-117/Vol-XIX/PandD Dated -25/5/2026).
5DHBVN 159 - Supply of LT XLPE armoured cable 4cx50sqmm( DHBVN 78/DD-117/Vol-XIX/PandD Dated -25/5/2026).
6Operation and Maintenance for 2nd Year..
7Operation and Maintenance for 3rd Year..
8Operation and Maintenance for 4th Year..
9Operation and Maintenance for 5th Year..
10[23.28.12.10]Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 10. 40 watt [Rate]
11[23.28.12.14]Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 14. 90 watt [Rate]
12[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
13[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
14[24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate]
15[24.2.4.1]LT CABLE 4.1. Laying of underground cable in pipe /existing open/closed trench etc as required:- 2.5 Sq mm to 10 Sq mm 2 to 4 Core [Through Rate]
16[24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core [Through Rate]
17[24.2.4.3]LT CABLE 4.3. Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core [Through Rate]
18[24.2.6.2]LT CABLE 6.2. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 2.5 sqmm [Through Rate]
19[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate]
20[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate]
21[24.4.2.1]STREET LIGHT 2.1. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 60 cm long. [Through Rate]
22[24.4.2.4]STREET LIGHT 2.4. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 150 cm long, with 30 cm high suitable size pole cap. [Through Rate]
23[24.4.4.1]STREET LIGHT 4.1. Erection of street light fitting on the pole including the cost of petty material required (irrespective of height/length of bracket) At Pole up to the height of 4.5 metres [Through Rate]
24[24.4.4.2]STREET LIGHT 4.2. Erection of street light fitting on the pole including the cost of petty material required (irrespective of height/length of bracket) At Pole above 4.5 metres but up to the height of 7 metres. [Through Rate]
25[24.4.8.1]STREET LIGHT 8.1. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 3 Metre Long pole with top dia 65 mm and bottom dia 130mm with base plate of size 200 x 200 x 12 mm [Through Rate]
26[24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm [Through Rate] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58418636
AUTHORITY Local Bodies
TENDER VALUE 1.55 Crore
LAST DATE 17-11-2026
Authority
Authority Name Gurugram Metropolitan Development Authority
Work Description Tender for Design, Engineering, Supply, Installation, Testing And Commissioning Of Outdoor Led Landscape Illumination Systems Works Of Tau Devi Lal Park, Sector-22, Gurugram -Including 5 Years Maintenance-Cum-Defect Liability Period.
Basic Detail
Tender No 202682967406 2AAF 475F 9244 5D40CD8DE5391838001
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 06 Nov 2026
Submission Date 17 Nov 2026
Open Date 18 Nov 2026
Finance
Tender Value 1.55 Crore
Tender Fee 5000
EMD 3.11 Lakhs
Exemption Available
Document List
6d153eac-6b40-42c1-92f7-e5aee4d70047.html
BOQ_639159.xls
OT0183005.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

6d153eac-6b40-42c1-92f7-e5aee4d70047.html

xls

BOQ_639159.xls

pdf

OT0183005.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender