Tender For Providing Cctv Surveillance At Various Locations At Police Complex, Dhanas, Chandigarh.
Tender Value
37.30 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
4 days left
EMD
74610
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Cctv Surveillance At Various Locations At Police Complex, Dhanas, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No. 40.5.25/6MP IP IR Dome CameraSupplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc, Type of Camera: Dome Camera , (As per Complete Item No. 1 of the DNIT). |
| 2 | 5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome Camera. |
| 3 | DSR item No.40.6.2 5/6MPIPIRBullet Camera Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc, (As per Complete Item No. 2 of the DNIT). |
| 4 | 5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera. |
| 5 | DSR item No.40.9.1Supplying Installation Testing and Commissioning of PTZ (Pan, Tilt and Zoom) IP IR Camera having following specifications and features etc :-PTZ (Pan,Tilt and Zoom) IP IR Camera having following specifications and features etc, (As per Complete Item No. 3 of the DNIT). |
| 6 | DSR Item No. 40.11.1 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below, (As per Complete Item No. 4 of the DNIT). : |
| 7 | 32 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16/25/32(36), |
| 8 | DSR item no.40.12.2 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.(As per Complete Item No. 5 of the DNIT). |
| 9 | 6TB (Terabytes) |
| 10 | DSR item no.39.24 Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, (As per Complete Item No. 6 of the DNIT). |
| 11 | DSR item no.39.26 Supply and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. Etc. complete as required. |
| 12 | DSR item No.39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 13 | DSR item No.39.21 Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, (As per Complete Item No. 9 of the DNIT). |
| 14 | 6PortLIU |
| 15 | 12PortLIU |
| 16 | DSR item No.39.19.1 Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, (As per Complete Item No. 10 of the DNIT). |
| 17 | Single Mode 6 Core Optical fiber cable |
| 18 | DSR item No.39.3.1 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, (As per Complete Item No. 11 of the DNIT). |
| 19 | 24portPoELayer2NetworkSwitchwithPoESupportof 370W or higher with each cooper port supporting 802.3at PoE+ min. |
| 20 | DSR item No.39.1.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, (As per Complete Item No. 12 of the DNIT). |
| 21 | 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 22 | DSR item No.39.17.1 Supplying,drawing,Installation,Testing and commissioningof CAT6UTPLSZH23AWGTwistedPair Cableinexisting conduit/ on surface, (As per Complete Item No. 13 of the DNIT). |
| 23 | 1Runofcable |
| 24 | DSR item No.39.12.1 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cordshould have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D |
| 25 | CopperPatchCordsoflength1m(3ft) |
| 26 | DSR item No. 39.6 Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. |
| 27 | 1G SFP Single Mode/Multi Mode |
| 28 | 10 G SFP + Single Mode/Multi Mode |
| 29 | DSR item no.42.4.3 LED Display Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. |
| 30 | 55 inch or larger |
| 31 | DSR item No.15.15 Supplying and laying of following sizeDWC HDPE pipe ISImarkedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 32 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 33 | DSR item No.15.16 SupplyingandlayingoffollowingsizeDWCHDPEpipeISI markedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeasrequired. |
| 34 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 35 | DSR item no.26.1.1 Online UPS - Input supply: Single Phase, Output Supply: Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input,Single Phase output AC Supply. The UPS shall include a Rectifier,(As per Complete Item No. 19 of the DNIT). |
| 36 | 2 KVA |
| 37 | DSR item No.39.22 Supply and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, (As per Complete Item No. 20 of the DNIT). |
| 38 | S/E of 8Mtr. long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 225mm x225mm x16mm alongwith inbuilt lockable junction box which should be operated with single key with connectors of Elmax/ Connectwell/ Essen/ Wago make for the cable termination as per site requirement and one no.(As per Complete Item No. 21 of the DNIT). |
| 39 | Labour charges for horizontal boring 1 Mtr. Below ground level for laying of DWC pipe including cost of 2 Nos. pit digging and refilling complete in all respects to entire satisfaction of the Engineer-In-Charge of the work. |
| 40 | Supply and erection of XLPE insulated PVC sheathed armoured copper conductor cable to be laid in existing pipe/pole including the cost of glands and making connections as per site requirement. The cable should strictly conforming to IS: 1554 specifications. The job also includes necessary painting and other petty material required to complete the same to the satisfaction of Engineer-In-charge of the work. The cable should be of Polycab/ KEI/ RPG/ Unistar (Universal)/ Havells/ Finolex/ R.R. Kabel make only. |
| 41 | Cable 3 x 1.5 Sq. mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender