Communications and Information Technology Government Departments Closing in 1 days TDR #58415720

Tender For Construction Of Eklavya Model Residential School Pangi At Killar (Dharwas), Tehsil Pangi, District Chamba (Hp) [Sh: Provision Of Fan Fitting, Power Distribution And Lightening Arrestor In Studio Apartments (Transit Accommodation) Blocks]

Issued by Government Departments · Kinnaur, Himachal Pradesh
Tender Value
12.24 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
1 days left
EMD
24494
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kinnaur → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Eklavya Model Residential School Pangi At Killar (Dharwas), Tehsil Pangi, District Chamba (Hp) [Sh: Provision Of Fan Fitting, Power Distribution And Lightening Arrestor In Studio Apartments (Transit Accommodation) Blocks]

BOQ

Name of Work:- Construction of Eklavya Model residential school Pangi at Killar (Dharwas), Tehsil Pangi, District Chamba (HP) [SH: Provision of Fan Fitting, Power distribution and Lightening arrestor in Studio Apartments (Transit Accommodation) Blocks]
Sl. No. Item Description
1SUB HEAD-I (Fan & Fittings & Misc.)
2Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50Hz, Operating temp range -5°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≤120<135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make)
3Powder coated CRCA Sheet Body (Thickness ≥0.50 mm) 40 Watt
4Powder coated CRCA Sheet Body (Thickness ≥0.50 mm) 18-22 Watt
5Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /Square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 4000°K /5700°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≤120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
6Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 12-15Watt
7SITC of following type prewired surface / recess mounted (minimum colour code 840) LED light fixture & integrated electronic driver (wherever required) suitable to operate on 240 volts 50 HZ AC supply including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make)
8LED retrofit type T Lamp/ Round Lamp /Radial lamp minimum 15Watt with accessories etc as required
910 watt LED Bulkhead Luminaire with Opal diffuser, PDC Housing 2 KV inbuilt surge protection with IP 65 protection rating with accessories etc as required
104 module polycarbonated UV stabilized LED Foot light 2.5/3 Watts with accessories etc as required
11Supplying, Installation, Testing & Commissioning of 45Watt Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen ≤120<135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make).
12Supply, Installation, Testing and Commissioning of 1200mm sweep BEE 5 Star rated ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) ≥6.0, air delivery 210 CM/Min (minimum), 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75°C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
13SITC of 250 mm sweep Ventilating fan with plastic body and louvers i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as required at site. (M/s HAVELLS / Crompton Greaves/Usha/ Khaitan/Bajaj/Orient)
14SITC of 150 mm sweep round Ventilating fan with plastic body and louvers i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as required at site. (M/s HAVELLS / Crompton Greaves/Usha/ Khaitan/Bajaj/Orient)
15SITC of 300 mm sweep fresh air fan With metalic body and net i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as reqd at site. (M/s Havel, Usha, Bajaj, Khaitan or similar superior make).
16Supplying and fixing musical/Ding Dong call bell suitable for D.C./A.C. single phase, 230 volts, complete as required.
17Supplying and fixing Batten/Angle holder i/c 10W LED Ball Lamp, connections, testing etc. complete as required.
18Supplying ,Installation, testing and commissioning of following type rating and size Geyser (Electric Storage Water Heater), suitable for single phase AC supply , including supplying of two no flexible connection pipes for water connection and suitable size PVC insulated, copper conductor, three core flexible wire for power supply connection etc. as required.
191Liter 3KW rating Instantaneous water heater with ultra thick SS tank and ABS shock proof body ( Make Havells/Bajaj/Crompton or similar superior make)
2025 Ltr Capacity Energy efficient Storage water Heater with thermostat control and preset thermal cutout , Steel tank and having 5 star rating ( Make Havells/Bajaj/Crompton or similar superior make)
21Supplying and fixing of G.I bracket for mounting of LED street light fitting on wall fabricated out of 40mm dia G.I pipe (medium class) of 1 Meter length having suitable machine made curve with suitable size of reducers, 40mmx3mm flat iron clamp and shall be painted with two coats of red oxide and two coats of aluminium paint including numbering complete as required.
22Supplying and fixing Adaptor Box(s) fabricated out of 16 SWG M.S. sheet complete with cutting, welding, painting, sign writing etc. all as required.
23Supplying and laying 1 Meter X 2 Meters, 6 mm. Thick -chequered Rubber Matting as required. (ISI marked)
24Supplying & fixing One No. First aid box of Standard type containing the following:- a) Instruction book (first aid to injured). b) 3 wound dressing large (for other injury) c) 3 wound dressing medium (for injured hands and feet) d) 1 absorbent cotton wool 200 gms. e) Antiseptic solution f) Bandages. g) 1 tube of burn ointment. h) 1 dressing scissors. i) 10 tablets of asprin.
25SH:- II- Distribution System & Cabling
26Supplying and fixing M.S. cubicle of depth 225 mm fabricated out of combination of 16 SWG M.S. sheet & 25mmx25mmx3mm angle iron complete with cutting, welding, painting, sign writing etc. having arrangement for housing HPSEB energy meter, SFU, MCB /RCCBs etc. & 6mm thick backlite sheet on back side complete as required. (Note : Measurement shall be done as per front surface area of panel)
27SITC of 200 A Three Phase Neutral (TPN) 4 Ways Busbar Chamber Box having size not less than 15\\"x15\\"x15\\" made out of 1.2 Mm Thick (16 G) i/c Fixing , interconnections etc Complete as reqd. (Havells Model IHBC020004)
28Supplying and fixing Four Pole 250A MCCB with variable Thermo-Magnetic Realese (Release range 160-200A) breaking capacity 36KA, (Ics = 100% Icu) at suitable for operation on 415 volts, 3 phase, 4 wire, 50HZ A.C. including spreaders for installation in the existing M.S. sheet steel , Medium Voltage, Cubicle Panel including drilling the holes in cubicle panel, making interconnections , etc. as required. (M/s L&T D-sine model DN2-250D or equivalent similar superior make)
29Supplying and fixing of following sizes of medium class PVC pipe along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
3050 mm
3175 mm
32Supplying & Laying XLPE Aluminium conductor armoured cable of 1.1 KV grade of following sizes on surface/ existing cable tray/pipe etc. as required.
332 x 6 Sq.mm.
342 x 16 Sq.mm.
354x16 Sq.mm.
363½ x35 Sq.mm.
373½ x50 Sq.mm.
38Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
392 x 6 Sq.mm.(19mm)
402 x 16 Sq.mm.(22mm)
413½ x 35 Sq.mm.(32mm)
423½ x 50 Sq.mm.(32mm)
43SUB HEAD-III (Earthing and Lightning Conductor)
44Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
45Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
46Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
47Providing and fixing 25mmx5mm GI strip on surface or in recess for connections etc as required
48Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
49Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required.
50Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc as required.
51Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
52Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
53Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
54Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58415720
AUTHORITY Government Departments
TENDER VALUE 12.24 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Tender for Construction Of Eklavya Model Residential School Pangi At Killar (Dharwas), Tehsil Pangi, District Chamba (Hp) [Sh: Provision Of Fan Fitting, Power Distribution And Lightening Arrestor In Studio Apartments (Transit Accommodation) Blocks]
Basic Detail
Tender No 46/EE/E/BSNL/ED/ETEN/SML/26-27
Bidding Type Tender
Location
City Kinnaur
State Himachal Pradesh
Key Dates
Publish Date 06 Nov 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 12.24 Lakhs
Tender Fee 590
EMD 24494
Exemption Not Available
Document List
BOQ_346254.xls
d5321909-997a-4933-8918-02e5aa2624e1.html
NITDARBHASKILAR06112026.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_346254.xls

html

d5321909-997a-4933-8918-02e5aa2624e1.html

pdf

NITDARBHASKILAR06112026.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender