Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #58415695

Tender For Construction Of 03 Technical Building At Cad Pulgaon Under Ge Pulgaon

Issued by Statutory Bodies & Commissions/Committees · Wardha, Maharashtra
Tender Value
26.12 Crore
Estimated cost
Bid Submission
12 Dec 2026
23 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Wardha → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 03 Technical Building At Cad Pulgaon Under Ge Pulgaon

BOQ

Name of Work:- CONSTRUCTION OF 03 TECHNICAL BUILDING AT CAD PULGAON UNDER GE PULGAON
Sl. No. Item Description
1Note:-Please refer schedule 'A' notes before quoting the tender.
2GENERAL SUMMARY
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’ Part- I (Ref prepriced schedule attached seperately)
4Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
6Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
7Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
8Lump sum price worked out by the contractor for ROAD, PATH, CULVERTS AND HARDSTANDING WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
9Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
10Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
11Lump sum price worked out by the contractor for FIRE FIGHTING & FIRE ALARM WORKS as listed in Schedule ‘A’ Part-IX (Ref prepriced schedule attached seperately)
12Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS as listed in Schedule ‘A’ Part-X (Ref prepriced schedule attached seperately)
13Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING WORKS as listed in Schedule ‘A’ Part-XI (Ref prepriced schedule attached seperately)
14Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-XII (Ref prepriced schedule attached seperately)
15SCH 'A' Pt - XIII (MISCELLANEOUS ITEMS)
16INTERNAL ELECTRIFICATION WORKS NOTE:- For items of INTERNAL ELECTRIFICATION notes given at the beginning of Sch ‘A’ Part-III ( INTERNAL ELECTRIFICATION) shall also be applicable.
17S&F LED lamp 9/10W , in Type B22, 230V AC, 50HZ single phase including bakelite batton holder with all fitting fixing accessories complete all as specified and directed.
18S & F Flame proof - weather proof LED flood light fitting with protection IP-65 suitable for 60 Watt for indoor type complete all as specified and directed.
19M&L flame proof distribution board TPN 4 way ( Totally enclosed dust and flame proof /jet proof ( IP-65 protection) including flame proof MCB TPN 32-01 NOS, SP 5 to 30 Amps-12 NOS 240 volts AC 10KA (10 Nos) and RCCB 01 Nos 40 Amps, TPN MCB 40 Amps 415 volts AC 50 Hz 16 KA (01 No) Flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981 , with complete internal bus bar & wiring upto terminals.
20M&L flame proof distribution board SPN 8 way ( Totally enclosed dust and flame proof /jet proof ( IP-65 protection) including flame proof MCB SPN 32 Amp-01 NOS, SP 5 to 30 Amps-6 NOS 240 volts AC 10KA, Flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981, with complete internal bus bar & wiring upto terminals.
21EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable.
22Supply and fix pipes Ductile iron pipe including specials, supplied and laid complete, Nominal dia 150 mm,K-9 as per IS 3589 all as specified and directed
23M&L for construction of brick Masonarry valve pit chamber 900mm x 900mm x 900mm (internal size), 100 mm thick PCC 1:4:8 type D2 lean concrete foundation using 40 mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick build in CM 1:6 rendaring 15mm thick in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.5mm thick MS sheet steel cover fixed on 50 x50x6 mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS coats of synthatic enamel paint of approved shade over a coat of primer (Red oxide) to all exposed surface complete all as specified and directed.
24EXTERNAL ELETRIC SUPPLY NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELETRIC SUPPLY) shall also be applicable.
25Supply and fixing PVC moulded case cable juction box outdoor type of size 200x140x95 mm with hinged front open door including locking arrangement and with one number MCB SP 6 Amp with necessary clamps made out of 25mm flat GI strip, nut, bolt etc and providing 3 core copper conductor 1.5 Sqmm from PVC junction box to street light fitting in with proper clamping complete all as specified and directed.
26Supply and fixing new 40mm bore or next suitable size (for 1x60 Watt LED fitting) light grade GI bracket 1.2 Mtr long bent to shape by cutting welding and well finishing including MS Clamp of flat iron of size 25x5mm suitable length 2 Nos complete for steel tubular poles with nuts,bolts and painting with two coats of aluminium paint over a coat of primer on MS Clamp complete all as specified and directed.
27Supply and fixing Double wall corrugated High Density POLYMER Ethylene (HDPE) pipe of size 50 mm as per IS 14930 (Part-2):2001, Laid in Trenches/floors and fixed on walls/poles, with and including necessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
28Supply and fixing Double wall corrugated High Density POLYMER Ethylene (HDPE) pipe of size 90 mm as per IS 14930 (Part-2):2001, Laid in Trenches/floors and fixed on walls/poles, with and including necessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
29M&L trenchless boring for Cable laying 150 mm bore size, not Exceeding 1.5 meter depth Complete all as specified and directed.
30HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breakerhaving rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630Amp.
31Supply, installation, commisioning and testing powder coated factory made outdoor type double door panel board conforming to IP 54 protection, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket around doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame size 50mmx50mmx6mm, pedestal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm grades stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable. multistranded housed with the following accessories:-(For PUMP HOUSE )(a) Incoming(i) ALUMINIUM BUS BAR 320 Amp(ii) MCCB 200 Amps 36 KA 4 Pole -01 Nos, 415 volt, 50 HZ(b) Outgoing (i) MCCB 160 Amps 36 KA 4 Pole -02 Nos, 415 volt, 50 HZ (ii) TPN 63 Amp ,16 kA-01 Nos (iv) TPN 32 Amp,16 KA-01 Nos(v) MCB SP 32 Amps 10 KA 4 Pole -2 Nos, 415 volt, 50 HZ(v) RYB indication LED type -03 Nos(vi) Star delta starter 60 HP,coil type wide band ,IP 54 440v (vii) Star delta starter 12.5 HP,coil type wide band ,IP 54 440v(viii) Ammeter digital, 96x96mm, with suitable ratio CTs with built in selector switch - 01 No(vii) Volt meter of range 0-500 Volts, 96 x 96 mm with built in slelctor switch - 01NOTE :- All MCCB's shall be adjustable thermal & Fixed magnatic type, ICS =100%icu.
32Supply, installation, commisioning and testing Compact sub stn 100 kva all as specified and directed consist of following components :-(a) 100 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked & BEE Star Labelled” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box Transformer as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 300W Losses @100% Load - 1050W (b) HT Section 11KV, 630A, Indoor Type 26.3 KA Load Break Switch (LBS) with fuse trip, earth switch, dynamic MIMIC arrangement, 230 V AC shunt trip coil and 2no+2nc aux. contacts. (c) LT Panel comprising of following switchgear on LV Side; Incomer - 01 no.-160 Amp 415V 4 Pole 25KA MCCB with thermal magnetic based release with O/L & S/C protection. - RYB Indication Lamp - Ammeter - Voltmeter(d) MS Steel Sheet enclosure suitable for Outdoor Installation with MS channels (Base). 01 Set Provision for receiving Incoming and Outgoing cables through Bottom entry, Excluding Termination Kit and Glands .
33ROAD, PATH, CULVERTS AND HARDSTANDING WORKSNOTE:- For items of ROAD PATH CULVERT AND HARDSTANDING WORKS notes given at the beginning of SCHEDULE 'A' PART -VI (ROAD PATH CULVERT AND HARDSTANDING WORKS) shall also be applicable.
34Material and labour for writing letters, figures or sign not exceeding 30cm high and widht of letter according to the height as per standard norms with radium letters with high prismatic grade and colour as per users requirments complete all as specified and directed.
35SEWAGE DISPOSAL WORKSNOTE:- For items of SEWAGE DISPOSAL WORKS notes given at the beginning of SCHEDULE 'A' PART -VIII (SEWAGE DISPOSAL WORKS) shall also be applicable.
36S&F 1000mm dia, 2.5m long, RCC Hume pipe septic tank designed to carry sewage and sullage water, excavtion in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc. complete for 10 users complete all as specified and directed. (TD Drg No. ____)
37S&F soakage well with & including excavation in any type of soil foundation in PCC 1:3;6 walls of honeycombed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia X 3.0m deep complete all as specified and directed. (TD Drg No. CEBZ/TD/78/2011)
38FIRE FIGHTING & FIRE ALARM WORKSNOTE:- For items of FIRE FIGHTING & FIRE ALARM WORKS notes given at the beginning of SCHEDULE 'A' PART -IX (FIRE FIGHTING & FIRE ALARM WORKS) shall also be applicable.
39Supply and fix Gun metal fire brigade inlet connection (suction collecting head) consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia sluice valve (one no 150mm dia NRV), and 150mm dia flanged outlet complete with all accessories.
40Supply and fix strainer CI of 80 mm dia complete all as specified and directed
41Supply and fix Foot valve CI confirming to IS 4038,200 mm dia all as specified and directed
42Supply and fix Foot valve CI confirming to IS 4038,80 mm (3”) dia all as specified and directed
43DEMOLITION AND DISMANTLING WORKSNOTE:- For items of DEMOLITION AND DISMANTLING WORKS notes given at the beginning of SCHEDULE 'A' PART -X (DEMOLITION AND DISMANTLINGWORKS) shall also be applicable.
44Removing the Unserviceable earthing from existing storage shed including connected earth continuity conductor complete all as specified
45Dismantling the unserviceable air termination rod with 2 mtr GI Pipe complete all as specified and directed
46Dismantling the unserviceable copper rope from existing storage shedcomplete all as specified and directed
47FRG Dunnage Box
48Supply of Anti-Static FRG dunnage box made to the dimension requirement (30 x 30 x 20 cm) complete all as specifed and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58415695
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 26.12 Crore
LAST DATE 12-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction Of 03 Technical Building At Cad Pulgaon Under Ge Pulgaon
Basic Detail
Tender No CEBZ/PUL/TOKEN/19 OF 2026-27
Bidding Type Tender
Location
City Wardha
State Maharashtra
Key Dates
Publish Date 06 Nov 2026
Submission Date 12 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value 26.12 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Not Available
Document List
656a3a7d-9e8c-4821-9a8a-8c21fdd81e0b.html
BOQ_894774.xls
Drawings.pdf
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

656a3a7d-9e8c-4821-9a8a-8c21fdd81e0b.html

xls

BOQ_894774.xls

pdf

Drawings.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender