Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58415693

Tender For Addn/Altn Of Lt Infrastructure And Connected Items For Mh Gaya

Issued by Statutory Bodies & Commissions/Committees · Gaya, Bihar
Tender Value
44.82 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
19 days left
EMD
89654
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gaya → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Addn/Altn Of Lt Infrastructure And Connected Items For Mh Gaya

BOQ

Name of Work:- ADDN/ALTN OF LT INFRASTRUCTURE AND CONNECTED ITEMS FOR MH GAYA
Sl. No. Item Description
1Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 150 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
2All as per item No. 01 here-in before but for cable of size 3.5 core 50 sqmm.
3All as per item No. 01 here-in before but for cable of size 3.5 core 70 sqmm.
4All as per item No. 01 here-in before but for cable of size 3.5 core 95 sqmm.
5All as per item No. 01 here-in before but for cable of size 3.5 core 120 sqmm.
6All as per item No. 01 here-in before but for cable of size 3.5 core 300 sqmm.
7Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified and directed .
8.-ditto as above but exceeding more than 1.5 m in depth
9Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed.
10Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
11Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
12Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. Brick size-0.23x0.15x0.7 note :-all measurement in meter
13M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
14Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level and filling in depth of poles. including neccassory form work and finishing the surface fair and even without using extra cement all as specified and directed.
15M&L for PCC 1:2:4 type B-2 using 20 mm graded broken stone aggregate as in mass concrete in foundations of stay and grouting of Lt panel, filling of road cutting etc complete all as specified and directed .
16Cutting of roads/walls/hardstanding for laying cable including match with surface through cement mortar complete with pcc 1:3:6, type C-1, all as specified and directed.
17M&L in replacement cable jointing kit for 1100 Volt grade cable heat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm to 150 sqmm complete all as specified and directed.
18M&L in replacement cable jointing kit for 1100 Vgrade cable for indoor type heat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400sqmm complete all as specified and directed .
19Supply,laying and in replacement galvanised steel tubing light grade complete with all fitting of size 40 mm dia for cable protection along with pole across road etc. Complete all as specified and directed.
20All as per item Ser No 19 above but size of pipe 50 mm dia.
21Cutting of walls/hardstanding for laying cable including match with surface through cement mortar complete with pcc 1:3:6, type C-1, all as specified and directed.
22Supply and fix Servo controlled oil cooled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 400 KVA complete all as specified and directed .
23Supply and fix sheet TP&N Vertical Loadline MCCB Incomer, 4 WAY, Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) G-FRAME MCCB INCOMER DB (Busbar Rating - 160 A) and flush to wall including all cutting etc. in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
24S & F Supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 36 KA in the DB complete with connection testing and commissioning. including providing thimble for out going cables complete all as specified and directed .
25Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/ 4poles and current carrying capacity of 16 to 32 amp in the DB complete with connection testing and commissioning complete all as specified and directed .
26M & L for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR Part I.
27M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site with levelling the ground all as specified an directed.
28Supply installation, testing and commissioning LT main Feeder panel board , outdoor type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.00 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, with 630 Amps on -load changeover switch, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB's as incoming and outgoing with MCCB's, lockable arrangement with aluminium bus bar three phase and neutral of capacity of 800 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- (1) LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011(3) Maker shall comply with 9 tank pre treatment plant with complete process.(2) PCC shall be measured and paid separately.INCOMING:- (a) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps,Ics=Icu=100%, conforms to IS -01 Nos(b) 4 Pole On-Load changeover switch of capacity 630 Amps, conforms to IS/IEC:60947-3, with SS Enclosure --- 01 NosOUT GOING:- (a) MCCB 250 Amps, adjustable thermal and magnetic type, 415 volts ,4 Pole, 36 KA, conforms to IS/IEC:60947-2 --- 01 Nos as outgoing.(b) MCCB 160 Amps, adjustable thermal and magnetic type, 415 volts ,4 Pole, 25 KA, conforms to IS/IEC:60947-2 --- 01 Nos as outgoing.(c) MCCB 200 Amps, adjustable thermal and magnetic type, 415 volts ,4 Pole, 36 KA, conforms to IS/IEC:60947-2 --- 03 Nos as outgoing.(d) MCCB 32 Amps, adjustable thermal and magnetic type, 4 pole 415 Volts, 25 KA, Conforms to IS/IEC:60947-2 -01 Nos.(e) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.(f) CT of suitable size(g) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(h) Wiring complete with copper wire of suitable size (i) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(j) Cable glands brass of suitable size for cable.
29Supply installation, testing and commissioning in replacement sub LT Feeder panel board outdoor type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 60X60X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2.0 mm the CRCA sheet duly compartmentalized for each MCCB's as incoming and outgoing with MCCB's, lockable arrangement with aluminium bus bar three phase and neutral of capacity of 600 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- (i) LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011 (ii) Maker shall comply with 9 tank pre-treatment plant with complete process. (iii) PCC shall be measured and paid separately. INCOMING:- (a) MCCB 160 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 50 KA -01 NosOUT GOING:- (a) MCCB 100 A,415V 4Pole, 35 KA Adjustable thermal & adjustable magnetic type ---- 03 No(b) MCB 6 to 16 A,415V 4Pole,16KA---- 3 Nos(c) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.(d) CT of suitable size(e) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(f) Wiring complete with copper wire of suitable size (g) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(h) Cable glands brass of suitable size for cable.
30Supply installation, testing and commissioning in replacement sub LT Feeder panel board outdoor type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 60X60X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2.0 mm the CRCA sheet duly compartmentalized for each MCCB's as incoming and outgoing with MCCB's, lockable arrangement with aluminium bus bar three phase and neutral of capacity of 800 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- (i) LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011 (ii) Maker shall comply with 9 tank pre-treatment plant with complete process. (iii) PCC shall be measured and paid separately. INCOMING:- (a) MCCB 200 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 35 KA -01 Nos OUT GOING:- (a) MCCB 125 A,415V 4Pole, 35 KA (ICs - 75% Icu) Adjustable thermal & adjustable magnetic type ---- 03 No(b) MCCB 63A,415V 4 Pole, 25KA, ---- 02 Nos(c) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.(d) CT of suitable size(e) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(f) Wiring complete with copper wire of suitable size (g) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(h) Cable glands brass of suitable size for cable.(i) MCB 6 to 16 A,415V 4Pole,16KA---- 3 Nos
31Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed.
32Taking up / down old and unserviceable xlpe alumunium cable of size 70 sqmm 3.5 core all as specified and directed
33Taking up / down old and unserviceable xlpe alumunium cable of size 16 sqmm 4 core all as specified and directed Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58415693
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.82 Lakhs
LAST DATE 27-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn Of Lt Infrastructure And Connected Items For Mh Gaya
Basic Detail
Tender No 8058/GE/26-27/E8
Bidding Type Tender
Location
City Gaya
State Bihar
Key Dates
Publish Date 06 Nov 2026
Submission Date 27 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 44.82 Lakhs
Tender Fee 500
EMD 89654
Exemption Not Available
Document List
8058Tenderdocuments.pdf
bc02409f-f056-43d6-a701-44194fee2db3.html
BOQ_894835.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
pdf

8058Tenderdocuments.pdf

html

bc02409f-f056-43d6-a701-44194fee2db3.html

xls

BOQ_894835.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender