Educational and Research Institute Government Departments Closing in 20 days TDR #58415596

Tender For Shifting Of 250 Kva Silent Type Dg Set From Radiology Department To Pg Hostels At Aiims Rishikesh..

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
9.18 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
20 days left
EMD
4.65 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Shifting Of 250 Kva Silent Type Dg Set From Radiology Department To Pg Hostels At Aiims Rishikesh..

BOQ

Name of Work:- Shifting of 250 KVA Silent type DG Set from Radiology Department to PG Hostels at AIIMS RISHIKESH..
Sl. No. Item Description
1Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 9 x 1.5 sq. mm
5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. mm
6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 6 sq. mm
7Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
8Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. with loose wire box of same OEM as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door
9Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. with loose wire box of same OEM as required. (But without MCB/RCCB/Isolator) 8Way Double Door
10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
11Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Double Pole
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole and neutral
13Taking out old single polemcb/Double pole mcb/2Module meter MCB and refixing them in new DB and making connection including testing and commissioning.
14Dismantling,shifting, servicing, testing and recommissioning of the existing 250 KVA Greeves make Silent Type Diesel Generator Set complete with AMF panel, sound-proof acoustic enclosure, auto-start, water-cooled 1500 RPM engine coupled with synchronous alternator, 3 Phase, 4 Wire, 415 V, including dismantling, loading, transportation, unloading, positioning, alignment and reinstallation at the designated location, complete with comprehensive servicing of the engine, alternator, control panel and all associated mechanical and electrical components as per OEM recommendations, supply and replacement of 02 Nos. 180 AH maintenance-free batteries of suitable make and capacity, fabrication, supply and installation of a heavy-duty MS trolley-mounted base frame with jack arrangement, provision of suitable anti-vibration pads as per OEM guidelines, reconnection/modification of fuel piping, exhaust piping, power and control cabling, earthing and all allied accessories, testing, commissioning and successful trial run under load, including all labour, materials, consumables, tools & tackles,copper control wire transportation and incidental works required for satisfactory completion of the work in all respects as directed by the Engineer-in-Charge.
15Supply, fabrication, testing and installation of 990-litre capacity M.S. Day Fuel Tank suitable for Greeves /Kirloskar Green Diesel Generator Set, fabricated from and 6 mm thick IS 2062 MS plates with internal stiffeners, complete with support frame, filler cap with strainer, vent pipe with flame arrestor, inlet, outlet, return connection, drain valve, inspection cover, fuel level gauge, all necessary fittings, red oxide zinc chromate primer and two coats of synthetic enamel paint, including hydrostatic testing, transportation, erection, interconnection with existing fuel piping and commissioning, complete in all respects as per OEM recommendations and the directions of the Engineer-in-Charge.
16Supply of following sizes PVC/XLPE insulated, PVC sheathed aluminium conductor 660/1100 volt grade armoured cable confirming to IS 1554 complete as required of following makes (Havells/Polycab/Skytone) A). 3.5core x 240sqmm
17Supply of following sizes PVC/XLPE insulated, PVC sheathed aluminium conductor 660/1100 volt grade armoured cable confirming to IS 1554 complete as required of following makes (Harvells/Polycab/Skytone) A). 3.5core x 150sqmm SH:-2 Providing Electrical power cable for with connection at existing LT Panel
18Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
19Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. Mm
20Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
21Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. Mm
22Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm
23Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
24Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm (62 mm)
25Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (45 mm)
26Earthing with GI earth plate 600mmX600mmX6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with characoal/coke and salt complete as reqd.
27Earthing with copper earth plate 600mmX600mmX3mm thick including accessories and providing masonary enclosure with cover plate having locking arangement and watering pipe of 2.7 meter long etc. with characoal/cock and salt complete as reqd.
28Providing and fixing 25mmX5mm GI strip in 40mm dia G.I. pipe from earthelectrode connection with brass nut, bolt, spring, washer excavation and re-filling etc. as reqd.
29Providing and fixing 25mmX5mm GI strip on surface or in recess for connection etc. as reqd.
30Providing and fixing 25mm X 5mm copper strip in 40mm dia G.I. pipe from earthelectrode as reqd. i/c connection with brass nut bolts spring washer excavation and re-filling etc. as reqd.
31Providing and fixing 25mm X 5mm copper strips on surface or in recess for connection etc. as reqd.
32S/L of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupllers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. Make - Rex/Zen duct 90 mm dia (OD-90 mm & ID-76 mm nominal)
33S/L of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, coupllers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. Make - Rex/Zen duct 160 mm dia (OD-160 mm&ID-135)
34Design Fabrication, Supply, Installation, testing and commissioning of cubical typed totally enclosed free standing type dust and vermin proof feeder pillar type LT Panel board, fully compartmentalized fabricated from 2mm Thick CRCA sheet steel, approx with 600 mm depth for incomer and out going strip type aluminium bus bar of 600 Amps. capacity complete with cable alley , duly powder coated in approved colour suitable for use on 415volt three phase with Neutral, 50Hz. AC Supply, controll copper wiring SMC /DMC Insulated indicating lamps. protection release, metering in coming and out going switch gear removable gland plate on top and bottom and provision of mechanical interlocking with following accessories.
35supply and fixing of following switch gear in the existing cubical Panel board complete with connection, testing and commissioning etc, as required. As under. Incoming, 630Amps. 50 KA FP MCCB with Rotary operating handle complete i/c ON Indication and extended terminal. Make:-L&T/ABB/Schnieder /Legrand
36supply and fixing of following switch gear in the existing cubical Panel board complete with connection, testing and commissioning etc, as required. As under. Outgoing, 250 Amps. 35/36 KA FP MCCB with Rotary operating handle complete i/c ON Indication and extended terminal. Make:-L&T/ABB/Schnieder /Legrand
37supply and fixing of following switch gear in the existing cubical Panel board complete with connection, testing and commissioning etc, as required. As under. Outgoing, 200 Amps. 35/36 KA FP MCCB with Rotary operating handle complete i/c ON Indication and extended terminal. Make:-L&T/ABB/Schnieder /Legrand A). R YB LED indication lamp. -8 Set .
38supply and fixing of following switch gear in the existing cubical Panel board complete with connection, testing and commissioning etc, as required. As under. Outgoing, S/F oF following accessories in the existing cubical panel board. Complete with wiring connection testing and commissioning etc. As required as under.B). Current Transformer 600/5Amps. Epoxy -1 Nos. C). Voltmeter digital meter with in built VSS . -1No. D Ammeter digital meter with in built ASS -1No. Including Neceassary Wiring Complete as one Job
39Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. 400 Amps,50 KA FP MCCB with Rotary operating handle complete i/c ON indication and extended terminal. Make:- L&T/ABB/Schneider/Legrand
40Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge
41Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
42Dismentalling and taking away of the follwing items , Old Copper flexible wire assorted size Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58415596
AUTHORITY Government Departments
TENDER VALUE 9.18 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Tender for Shifting Of 250 Kva Silent Type Dg Set From Radiology Department To Pg Hostels At Aiims Rishikesh..
Basic Detail
Tender No 06/EE/Electrical/2026-27
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 06 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 9.18 Lakhs
Tender Fee Ref. Documents
EMD 4.65 Lakhs
Exemption Not Available
Document List
947f0d0e-4abd-4933-9484-f07a8a2dc283.html
BOQ_980905.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

947f0d0e-4abd-4933-9484-f07a8a2dc283.html

xls

BOQ_980905.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender