Tender For Construction Of Govt. College Of Nursing (G+1) And Hostel Building (G+3) At Balukhanda, Dist.-Puri.
Tender Value
17.28 Crore
Estimated cost
Bid Submission
11 Nov 2026
3 days left
EMD
17.29 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Puri → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Govt. College Of Nursing (G+1) And Hostel Building (G+3) At Balukhanda, Dist.-Puri.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKEarth work in excavation of foundation trenches in ordinary soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge.College Building.Ground floor |
| 2 | Hostel Building.Ground floor |
| 3 | Security room and Gate complex |
| 4 | Compound wall |
| 5 | Internal Drainage |
| 6 | Internal road |
| 7 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. College Building.Ground floor |
| 8 | Hostel Building.Ground floor |
| 9 | Security room and Gate complex |
| 10 | Compound wall |
| 11 | Internal Drainage |
| 12 | Internal road |
| 13 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.College Building.Ground floor |
| 14 | Hostel Building.Ground floor |
| 15 | Security room and Gate complex |
| 16 | Compound wall |
| 17 | Internal Drainage |
| 18 | Internal road |
| 19 | Land devlopment and surface filling |
| 20 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.College Building.Ground floor |
| 21 | Hostel Building.Ground floor |
| 22 | Security room and Gate complex |
| 23 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6\\") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge.College Building.Ground floor |
| 24 | Hostel Building.Ground floor |
| 25 | Security room and Gate complex |
| 26 | Compound wall |
| 27 | Internal Drainage |
| 28 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. College Building.Ground floor |
| 29 | Hostel Building.Ground floor |
| 30 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.College Building.Ground floor |
| 31 | Hostel Building.Ground floor |
| 32 | Security room and Gate complex |
| 33 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.College Building.Ground floor |
| 34 | First floor |
| 35 | Second floor |
| 36 | Hostel Building.Ground floor |
| 37 | First floor |
| 38 | Second floor |
| 39 | Third floor |
| 40 | Terrace floor |
| 41 | Security room and Gate complex |
| 42 | Compound wall |
| 43 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.College Building.Ground floor |
| 44 | First floor |
| 45 | Hostel Building.Ground floor |
| 46 | First floor |
| 47 | Second floor |
| 48 | Third floor |
| 49 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.College Building.footing |
| 50 | Pedestal |
| 51 | Column up to plinth |
| 52 | Plinth Beam |
| 53 | Hostel Building.Footing |
| 54 | Pedestal |
| 55 | Column up to plinth |
| 56 | Plinth Beam |
| 57 | Security room and Gate complex Footing |
| 58 | Column up to plinth |
| 59 | Plinth Beam |
| 60 | Compound wallFooting |
| 61 | Column up to plinth |
| 62 | Plinth Beam |
| 63 | College BuildingR.C.C Column Ground floor |
| 64 | First floor |
| 65 | Terrace floor |
| 66 | Hostel BuildingR.C.C Column Ground floor |
| 67 | First floor |
| 68 | Second floor |
| 69 | Third floor |
| 70 | Terrace floor |
| 71 | Security room and Gate complex R.C.C Column Ground floor |
| 72 | Compound wallR.C.C Column Ground floor |
| 73 | College BuildingR.C.C Lintel Ground floor |
| 74 | First floor |
| 75 | Hostel BuildingR.C.C Lintel Ground floor |
| 76 | First floor |
| 77 | Second floor |
| 78 | Third floor |
| 79 | Security room and Gate complex R.C.C Lintel Ground floor |
| 80 | College BuildingR.C.C ChajjaGround floor |
| 81 | First floor |
| 82 | Terrace floor |
| 83 | Hostel BuildingR.C.C Chajja Ground floor |
| 84 | First floor |
| 85 | Second floor |
| 86 | Third floor |
| 87 | College BuildingR.C.C Roof beam Ground floor |
| 88 | First floor |
| 89 | Terrace floor |
| 90 | Hostel BuildingR.C.C Roof beam Ground floor |
| 91 | First floor |
| 92 | Second floor |
| 93 | Third floor |
| 94 | Terrace floor |
| 95 | Security room and Gate complex R.C.C Roof beam Ground floor |
| 96 | Compound wallR.C.C beam |
| 97 | College BuildingR.C.C SlabGround floor |
| 98 | First floor |
| 99 | Terrace floor |
| 100 | Hostel BuildingR.C.C Slab Ground floor |
| 101 | First floor |
| 102 | Second floor |
| 103 | Third floor |
| 104 | Terrace floor |
| 105 | Security room and Gate complex R.C.C Slab Ground floor |
| 106 | College BuildingR.C.C Stair caseGround floor |
| 107 | First floor |
| 108 | Hostel BuildingR.C.C Stair caseGround floor |
| 109 | First floor |
| 110 | Second floor |
| 111 | Third floor |
| 112 | College BuildingR.C.C wallGround floor |
| 113 | R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge.Internal Drainage footing |
| 114 | Internal DrainageR.C.C drainage wall |
| 115 | Internal DrainageR.C.C Slab |
| 116 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.College Building.Ground Floor |
| 117 | First floor |
| 118 | Terrace floor |
| 119 | Hostel BuildingGround floor |
| 120 | First floor |
| 121 | Second floor |
| 122 | Third floor |
| 123 | Terrace floor |
| 124 | Security room and Gate complex |
| 125 | Compound wall |
| 126 | Internal Drainage |
| 127 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (Out side)College Building.Ground Floor |
| 128 | First floor |
| 129 | Terrace floor |
| 130 | Hostel BuildingGround floor |
| 131 | First floor |
| 132 | Second floor |
| 133 | Third floor |
| 134 | Terrace floor |
| 135 | Security room and Gate complex |
| 136 | Compound wall |
| 137 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (Inside)College Building.Ground Floor |
| 138 | First floor |
| 139 | Terrace floor |
| 140 | Hostel BuildingGround floor |
| 141 | First floor |
| 142 | Second floor |
| 143 | Third floor |
| 144 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. College Building.Ground Floor |
| 145 | First floor |
| 146 | Terrace floor |
| 147 | Hostel BuildingGround floor |
| 148 | First floor |
| 149 | Second floor |
| 150 | Third floor |
| 151 | Terrace floor |
| 152 | Security room and Gate complex |
| 153 | Compound wall |
| 154 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.College Building.Ground Floor |
| 155 | First floor |
| 156 | Terrace floor |
| 157 | Hostel BuildingGround floor |
| 158 | First floor |
| 159 | Second floor |
| 160 | Third floor |
| 161 | Terrace floor |
| 162 | Security room and Gate complex |
| 163 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.College Building.Ground Floor |
| 164 | First floor |
| 165 | Hostel BuildingGround floor |
| 166 | First floor |
| 167 | Second floor |
| 168 | Third floor |
| 169 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.College Building.Ground Floor |
| 170 | First floor |
| 171 | Hostel BuildingGround floor |
| 172 | First floor |
| 173 | Second floor |
| 174 | Third floor |
| 175 | Supplying, fitting and fixing full body matt finish vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make(JOHNSON / KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.College Building.Ground Floor |
| 176 | First floor |
| 177 | Hostel BuildingGround floor |
| 178 | First floor |
| 179 | Second floor |
| 180 | Third floor |
| 181 | Security room and Gate complex |
| 182 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON /RAK / KAJARIA) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.College Building.Ground Floor |
| 183 | First floor |
| 184 | Hostel BuildingGround floor |
| 185 | First floor |
| 186 | Second floor |
| 187 | Third floor |
| 188 | Security room and Gate complex |
| 189 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.Hostel BuildingGround floor |
| 190 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in Dado over 12mm thick bed of cement mortar 1:3 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.Hostel BuildingGround floor |
| 191 | Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mm of size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (JOHNSON / RAK / KAJARIA) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.College Building.Ground Floor |
| 192 | Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.Hostel BuildingGround floor |
| 193 | Providing & Fixinng factory made 100% Solid WPC (Wood Polymer Composite) - Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (Make-Green Land / Century/ Alstone) College Building.Ground Floor |
| 194 | First floor |
| 195 | Hostel BuildingGround floor |
| 196 | First floor |
| 197 | Second floor |
| 198 | Third floor |
| 199 | Security room and Gate complex |
| 200 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter 30 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Make-Green Land / Century/ Alstone)College Building.Ground Floor |
| 201 | First floor |
| 202 | Hostel BuildingGround floor |
| 203 | First floor |
| 204 | Second floor |
| 205 | Third floor |
| 206 | Security room and Gate complex |
| 207 | Supplying and fixing of Powder coated 50-60 microns approved colour of Aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass of make-Saint gobain/ AIS/ Gardian/ modi. the rate quoted inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion ,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame - 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter - 34.6 x 26 x 1.5mm thickness, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Jindal, Hindalco, schueco)College Building.Ground Floor |
| 208 | Hostel BuildingGround floor |
| 209 | Metal Fire DoorProviding and fixing ISI Marked un-insulated fire rated door confirming to IS 3614:2021,& tested to IS17518,and shall carry a unique label with certification/test report number.The fire rating shall be for 120minutes integrity only.Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2(18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm/sqm).Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers.The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement.All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of double leaf doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS-304 grade of size100x75x3mm,1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back to back per leaf, with spindle,SS 304, SS finish. 1no of Door closer with spring size of EN 2- 4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Shakti Hormannm,Tata pravesh)College Building.Ground Floor |
| 210 | First floor |
| 211 | Hostel BuildingGround floor |
| 212 | First floor |
| 213 | Second floor |
| 214 | Third floor |
| 215 | Supplying and installing UPVC- 3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32 mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/AIS/Gardian/modi . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) College Building.Ground Floor |
| 216 | First floor |
| 217 | Hostel BuildingGround floor |
| 218 | First floor |
| 219 | Second floor |
| 220 | Third floor |
| 221 | Security room and Gate complex |
| 222 | Supplying, fitting & fixing in all floors of S.S. grills, grill gates, S.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of S.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge..College Building.Ground Floor |
| 223 | First floor |
| 224 | Terrace floor |
| 225 | Hostel BuildingGround floor |
| 226 | First floor |
| 227 | Second floor |
| 228 | Third floor |
| 229 | Terrace floor |
| 230 | Security room and Gate complex |
| 231 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).College Building.Ground Floor |
| 232 | First floor |
| 233 | Terrace floor |
| 234 | Hostel BuildingGround floor |
| 235 | First floor |
| 236 | Second floor |
| 237 | Third floor |
| 238 | Terrace floor |
| 239 | Security room and Gate complex |
| 240 | Compound wall |
| 241 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).College Building.Ground Floor |
| 242 | First floor |
| 243 | Terrace floor |
| 244 | Hostel BuildingGround floor |
| 245 | First floor |
| 246 | Second floor |
| 247 | Third floor |
| 248 | Terrace floor |
| 249 | Security room and Gate complex |
| 250 | Compound wall |
| 251 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. College Building.Ground Floor |
| 252 | First floor |
| 253 | Terrace floor |
| 254 | Hostel BuildingGround floor |
| 255 | First floor |
| 256 | Second floor |
| 257 | Third floor |
| 258 | Terrace floor |
| 259 | Security room and Gate complex |
| 260 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).College Building.Ground Floor |
| 261 | First floor |
| 262 | Terrace floor |
| 263 | Hostel BuildingGround floor |
| 264 | First floor |
| 265 | Second floor |
| 266 | Third floor |
| 267 | Terrace floor |
| 268 | Security room and Gate complex |
| 269 | Painting two coat with approved synthetic enamel paint to new wood work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).College Building.Ground Floor |
| 270 | First floor |
| 271 | Hostel BuildingGround floor |
| 272 | First floor |
| 273 | Second floor |
| 274 | Third floor |
| 275 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).College Building.Ground Floor |
| 276 | First floor |
| 277 | Terrace floor |
| 278 | Hostel BuildingGround floor |
| 279 | First floor |
| 280 | Second floor |
| 281 | Third floor |
| 282 | Terrace floor |
| 283 | Security room and Gate complex |
| 284 | Internal road |
| 285 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ) College Building.Ground Floor |
| 286 | First floor |
| 287 | Hostel BuildingGround floor |
| 288 | First floor |
| 289 | Second floor |
| 290 | Third floor |
| 291 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.College Building.First Floor |
| 292 | Terrace floor |
| 293 | Hostel BuildingFirst floor |
| 294 | Terrace floor |
| 295 | Security room and Gate complex |
| 296 | Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30% Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² @ 28dTensile elongation: 60% @ 20°CShore A Hardness >85 (between 3 - 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)(Make-Myk, Fosroc, Sika)College Building.First Floor |
| 297 | Terrace floor |
| 298 | Hostel BuildingFirst floor |
| 299 | Terrace floor |
| 300 | Security room and Gate complex |
| 301 | Supplying & fitting & fixing of grid mineral fibre ceilling board having size 600mmx600mmx16mm of approved desgin & quality complete with frame & all fittings & fixtures as per direction of the Engineer-in-charge.College Building.Ground Floor |
| 302 | First floor |
| 303 | Supplying and Installing of Expoband one Flexible Polyolefin (FPO) membrane system which is designed to be bonded over expansion and movement joints up to 150mm in structures to prevent the passage of water having Elongation at break : 400%,Tensile Strength : 12.5N/mm2 (DIN EN 12311-2 Method B),Water vapour permeability : 2.7g/Sqm/day (DIN EN 1931-Method B). It is bonded in position using two-part epoxy adhesive, Nitobond PC40 as per manufacturer direction after proper fixing of the necessary backup materials as specified and directed by the Engineer In-charge. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation etc. complete as per design, drawing & instructions of EIC.(make-Myk,Fosroc,Sika) College Building.Ground Floor |
| 304 | First floor |
| 305 | Terrace floor |
| 306 | Hostel Building Ground floor |
| 307 | First floor |
| 308 | Second floor |
| 309 | Third floor |
| 310 | Terrace floor |
| 311 | Loosening to a depth of 150mm, leveling and compacting original ground supporting embankment /sub-grade as per approved drawing and technical specifications as per Section 900 and Clause 305, 305.3.4 of MoRT&H Specification for Road & Bridge works (5th Revision) and as per direction of Engineer-in-Charge.Internal road |
| 312 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) Internal road |
| 313 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 as per direction of the Engineer-in-charge.Internal road |
| 314 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Internal road |
| 315 | Supply and Installation of System comprises of Semi unitized extruded aluminum Structural Glazing wall panels comprising of extruded Vertical Aluminium mullions and Horizontal transoms (JINDAL/HINDALCO/EQUEVALENT ) with super Durable Powder Coating finish of minimum 60 Microns confirming standards to withstand wind pressure. The mullions and transoms are installed on locations as indicated in the architectural drawings. The framing members provide no structural support for the building and the Structural Glazing wall is deemed to be a lightweight façade which is intended to separate the external from the internal of the building and provides natural light into the building. The curtain wall system is designed to have internal drainage system within the extruded sections with 6MM Blue toughened glass. Gaskets are employed as water barrier between the aluminum gridwork and the glazed sashframe, which are fully drained in the event of leakage past the primary seal. The external grooves are covered with application of backer rod with weather sealant of approved make as indicated in the concept drawing. Fabricating and supplying Mild Steel ( HDG coated ) Brackets to accommodate 3 Dimensional movement for achieving perfect verticality and proper fixing of structural glazing system with the RCC/ masonry/structural steel framework of building structure, using stainless steel (chemical/mechanical) anchor fasteners/ bolts, Teflon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel Grade 316, of the required capacity and in required numbers College Building.Ground Floor |
| 316 | First floor |
| 317 | Hostel Building Ground floor |
| 318 | First floor |
| 319 | Second floor |
| 320 | Third floor |
| 321 | Terrace floor |
| 322 | Providing & Installation of GFRC GFRC JALI (Glass Fiber Reinforced Concrete) thickness of 25-30 mm & Border thickness of 50 mm with Pattern, design, and colour of approved make to be fixed on/between RCC /Block work Column or structural work with Dry Fixing method with appropriate SS Pipe & Cleats frame work, using fasteners, and necessary hardware etc. The element shall be made from '53 grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre make 'Owens Corning' or equivalent, Super plasticizers / Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROX (Germany)' or equivalent. The material casting shall take place in Synthetic Rubber / FRP Mould manufactured by Mould / Tool / Mould Grade Resin of Revex/ 'Reckli' or equivalent. (Make-Unistone,Samudyam,Eco Vision)College Building.Ground Floor |
| 323 | First floor |
| 324 | Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.Land devlopment and surface filling |
| 325 | E.I. WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.Group A |
| 326 | Group B |
| 327 | Group C |
| 328 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 329 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 330 | Supply& fixing of Modular type 6 Amp one way switch and 6 A socket outlet with metal box and modular cover Separate Board on surface or recess including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)) |
| 331 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI / V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 332 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI / V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 333 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI / V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 334 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI / V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 335 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI / V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6) |
| 336 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 337 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 6 Way(8+(4x3)+(3x6)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-18 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 338 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 339 | Supplying and fixing 16 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 340 | Supplying and fixing 32 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 341 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 342 | Supplying and fixing 16 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 343 | Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 344 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year |
| 345 | Fittings & FixturesSupply and fixing Of 4Ft surface mounted/suspended Single Piece Constructed CRCA LED TUBE BATTEN required pre-wired terminal one side with body earthing provision -(TMC502 1xT-LED 22W) along with mounting of 1No.s Master PVC T8 Base Tube 2100Lumen Pack,Efficacy >116Lm/W, 18Watt,CRI >=80, PF >0.9, CCT 4K, IP20, 40K Burning Hours, Temp -20To45Degree,CE marking RoHS compliance KEMA Keur certificate. The luminaire must be Replacement Warranty will be 2 years.Make- Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj |
| 346 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W (2'x2' 595x595x70mm) and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years. To be used in dining hall and big office room. |
| 347 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 348 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 349 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) |
| 350 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) |
| 351 | MAIN PANELS/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.40X10MM Separate Aluminium Earth bus bar should be installed. ON/OFF/TRIP indication for all the feeders shall be given. Mandatory provision of cable alley is to be given.In commer- 01 no 250 A, 36kA 4P LSIG Microprocessor release MCCB ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) (FROM EX TRANSFORMER).01 no of 160A 4P onload changeover switch (Make-ABB/Siemens/Schneider/Legrand).Busbar-04 numbers of 400Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 05 numbers of 63A 4P MCCB,16Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ic( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS.Out going- 04 numbers of 125A 4P MCCB,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ic( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS.Out going- 04 numbers of 100A 4P MCCB,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ic( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS.Out going- 4 numbers of 32A 4P MCB,C series, 10 Ka (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Out going- 4 numbers of 63A 4P MCB,C series, 10 Ka (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication.1 no. 3P+N 50kA/POLE type 1+2 SPD with 600A HRC backup fuse(Make of SPD-ABB/DEHN/OBO ). |
| 352 | Floor Power panel :-S/I/T&Commissioning of LT indoor floor mounted cubical type electrical power panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING power)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed.ON/OFF/TRIP indication for all the feeders shall be given. Mandatory provision of cable alley is to be given.In commer- 1 number of 125A 4P MCCB,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS.Busbar-1&2 04 numbers of 200Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 05 numbers of 63A 4P MCB 10KA,C series (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/ Schneider/ ABB/ Legrand).(iii)01 set of 3 ph digital type Ammeter(0-150)A(Make-Siemens/ Schneider/ ABB /Legrand) with CTs 150/5A 3 nos class 1 type.1 no. 3P+N 40kA 4P type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB 10KA,C series (Make-LEGRAND/ Siemens/ Schneider/ABB ). |
| 353 | Floor Light panel :-S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING power)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed.ON/OFF/TRIP indication for all the feeders shall be given. Mandatory provision of cable alley is to be given.In commer- 1 number of 100A 4P MCCB,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ABB Formula/ Schneider- CVS.Busbar-1&2 04 numbers of 200Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 1 05 numbers of 32A 4P MCB 10KA,C series (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-150)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 100/5A 3 nos class 1 type.1 no. 3P+N 40kA 4P type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB 10KA,C series (Make-LEGRAND/ Siemens/ Schneider/ABB ). |
| 354 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical UPS Outgoing panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING power)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed.ON/OFF/TRIP indication for all the feeders shall be given. Mandatory provision of cable alley is to be given.In commer- 01 no 63A 4P Changeover ( Make-LEGRAND/ Siemens/ Schneider/ABB) (Icu=100%Ics)with shunt trip.Busbar- 04 numbers of 100Amps copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 05 nos 20A 4P MCB 10kA,C series UPS floor panel . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200.Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-150)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 100/5A 3 nos class 1 type.1 no. 3P+N 40kA 4P type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB 10KA,C series (Make-LEGRAND/ Siemens/ Schneider/ABB ). |
| 355 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical UPS floor panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed.ON/OFF/TRIP indication for all the feeders shall be given. Mandatory provision of cable alley is to be given.In commer- 01 no 20 A 4P MCB 10KA,C series (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Busbar-1&2 04 numbers of 100Amps Copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) .Out going- 5 nos 16 A 4P MCB 10KA,C series (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/ Schneider/ ABB/ Legrand).(iii)01 set of 3 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 100/5A 3 nos class 1 type.1 no. 3P+N 40kA 4P type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB 10KA,C series (Make-LEGRAND/ Siemens/ Schneider/ABB ) . |
| 356 | UPS 20 KVA :-Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 357 | CABEL :-Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5 core x 240 sq mm Aluminium armoured Cable.(FOR MAIN PANEL) |
| 358 | 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR FLOOR PANEL) |
| 359 | 4 core 16 sqmm Aluminium armoured Cable (For lift, external feeder pillar and UPS outgoing panel) |
| 360 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.3.5 core x 240 sq mm brass double compression gland and aluminium lugs |
| 361 | 3.5 core x 50 sq mm brass double compression gland and aluminium lugs |
| 362 | 4 core x 16 sq mm brass double compression gland and aluminium lugs |
| 363 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 364 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 365 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 366 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 367 | EARTHING :-Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 368 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 369 | Providing and fixing 50 mm X 6 mm GI strip on surface or in recess for connections etc. as required. |
| 370 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 371 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 372 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 373 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 374 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 375 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 376 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 377 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OOBO/Dehn/ABB |
| 378 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 379 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 380 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 381 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 382 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 383 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 384 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 385 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 386 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 387 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 388 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 389 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge.. |
| 390 | SAFTEY EQUIPMENT :-Supply installation of high-voltage insulating mat has a thickness of 3.0 mm, rated for maximum use voltage of 33 kV. It withstands an AC proof voltage of 36 kV and an AC dielectric strength of 65 kV, with maximum leakage current limited to 10 mA. Minimum insulation resistance (5000V megger) is 1,00,000 MΩ. Tensile strength is minimum 15 N/mm², with 250% minimum elongation. After 168 hrs aging at 70±1°C, retention is minimum 75% (tensile & elongation); after 48 hrs immersion in acid/alkali/diesel/oil, retention is minimum 80%. The mat offers low-temperature resistance and flame retardance, made of synthetic elastomer, conforming to IS 15652. complete as per direction of Eng-in-charge.(Size-10mx1m) make : mandelia insulation and transmission co./Duratuf/Raychem/Vardhman |
| 391 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.. |
| 392 | SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages.Make-Prolite/Bajaj |
| 393 | FIRE FIGHTINGPUMPS AND APPURTENANCES :-Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 946 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar/Grundfoss |
| 394 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/ABB |
| 395 | Supplying, installation testing and commissioning of the following-: ‘C’ class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. Make-TATA/JINDAL/SAIL100mm NB |
| 396 | 80mm NB |
| 397 | 25mm NB |
| 398 | Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/AUDCO/Leader100mm NB |
| 399 | Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader100mm NB |
| 400 | Supply,Installation,Testing & Commissioning of orifice plate made of 6mm thick stainless steel with orifice of required size in between flane and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg/ sq cm complete as required. |
| 401 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: H.GURU/G.GURU |
| 402 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: DANFOSS/INDFOSS make |
| 403 | Supply,Installation,Testing & Commissioning of 100 MM stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader |
| 404 | Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required. |
| 405 | Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 406 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 407 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 408 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 409 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex |
| 410 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
| 411 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 100mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Minimax/Newage/Fireshield/Safex |
| 412 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog/Kalpex .4.5 kg capacity |
| 413 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog/Kalpex.6 kg capacity |
| 414 | Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. |
| 415 | Supplying, installing, testing and commissioning of photo electric adressable multi sense smoke detector with inbuilt isolator module/isolator base ,base, junction box and other accessories.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 416 | Supply, installing, testing and commissioning of of 2 Loop Network Panel Micro processor based 2 wire fault tolerant loop,with inbuilt network port (each loop accessing 99 or more detectors and 99 or more modules ) fire alarm/detection control panel. The Panel shall have 10000 or more event log history . Panel shall be capable of having 1600 or more configurable zones .The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have 7 Inch Touch Screen unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have provision for 40 or more Zones with Individual LED Indicators expdable upto 200 Zones or higher. The panel shall have a built in power supply and battery charger along with maintenance free 7 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by UL/EN54 The panel shall support detection logics like coincidence & verification detections for the false alarm management. The Panel shall adjust the sensitivity between day and night to maintain the better detection/reponse time. The Panel shall be capabale of programming through PC ; Touch Screen of USB .This panel having facility of MODBUS protocol over TCP/IP for BMS integration.The panel should have provision for inbuilt RJ45 connection terminal for connecting to the LAN with inbuilt BACNET Protocol. Make- Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 417 | Supplying, installation, testing & commissioning of Addressable Single Output Module,Single Output Module, provides dry contact (Loop powered) or active output (24VDC required, cable monitored) (Certified by LPCB)) indicates system status: GREEN / AMBER / RED.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 418 | Supplying, installing, testing and commissioning of Addressable Manual Call Point with back box.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 419 | Supplying, installing, testing and commissioning of Analogue Addressable Loop powered Sounder with strobe light.MakeHoneywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information |
| 420 | Supplying, installing, testing and commissioning of Analogue Addressable Loop powered Sounder with strobe light.MakeHoneywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender