Tender For Special Repairs To Electrical Installations, Ac Units And Ups Arrangements In Taluk Office Building At Bhavani In Erode District.
Tender Value
2.47 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
14 days left
EMD
2500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Erode → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Electrical Installations, Ac Units And Ups Arrangements In Taluk Office Building At Bhavani In Erode District.
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring with 2x1.5sq.mm (22/0.3) PVC insulated unsheathed SC. Cu. conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch in flush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light/ fan point (for electronic regulator)(5 points per coil).(SD-22) |
| 2 | Renewal by Supply and fixing of 4 Feet LED 20W with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting(SD-443) |
| 3 | Renewal by supply and fixing of 1200mm 48\\" AC Ceiling Fan High Speed complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp.(DATA-1) |
| 4 | Renewal by supply and fixing 400mm Oscillating type Wall mounting fan with regulator complete on wall with connection complete(Higher end)(DATA) |
| 5 | Renewal by Supply and fixing of 3Nos. 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) (SD-142) |
| 6 | Renewal by supply and fixing of 5A/15A 3pin combined flush type wall socket with 15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet(SD-141) |
| 7 | Renewal by supply and fixing of 20Amps DP plug and socket in sheet steel enclosure with 32A DP MCB in flush with wall with earth connection.(For AC Plug)(SD-144) |
| 8 | Renewal by supply erection testing commissioning of 2.00TR (6000 Kcal/Hr) ABS Plastic split type Air Conditioner confirming to IS1391[Part 2] 1992 with Rotary compressor operating on refrigerant R-22/Non CFL suitable for wall mounting for operating on 230V 50HZ single phase AC supply with Five Star rating as per BEE Specification and capable of performing the following functions. A) Cooling, B) dehumidifying C)Air circulating D)Filtering the installation work for the above split type AC units includes the following. 1.Mounting/fittiing indoor and outdoor units at their respective locations. 2.Laying refrigerant pipe line of 6mtrs distance and connecting the both units after drilling hole in the wall if required thickness of the copper tubing shall not be less than 0.80mm 3.Insulating the suction pipe with expanded polythene foam 5mm thick tubing. 4.Laying 15mm dia flexible PVC drain pipe of 6mtrs length to throw out the condensate water being formed in the indoor unit. 5.Leak testing the entire gas unit. 6.Charging refrigerant gas in the unit. 7.suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 4mtrs length and up to switch within 3mtrs of location of indoor unit (Make -Carrier/voltas/ Blue star make only)(SOR M-1985) |
| 9 | Renewal by supply and fixing of 5KVA Automatic voltage stabilizer of wall mounting type with Automatic time delay switching arrangements suitable to operate on 230V Single phase supply.(SOR M 1989) |
| 10 | Renewal by supply and fixing of angle iron stand for outdoor split A.C unit (SOR M 1991) |
| 11 | Renewal by Supply, Erection,Testing and Commissioning of uninterrupted Power supply (UPS) (sine Wave)(Microtek/ Amaron/ Luminious/ Exide) unit of capacity 2KVA with input Voltage 12V DC Supply, Output Voltage 230V, 50HZ AC Supply with following accessories/Circuits and with following accessories and with 2Hour of Battery backup at full load respectively. 1.Battery charging Device 2.Invert Circuit 3.Over load as well as short circuit 4.Indication for operations like Battery charging, overload, Low Battery etc. 5.Reset Switch - 1No. 6.Tall Tubular Battery- 2Nos of 12V AC IT500 150AH(Reputed make) 7.Two layer Wooden/steel stand. [SOR -M- 2106] |
| 12 | Renewal by Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 1.5 sq.mm copper wire with painting of suitablecolour(SD-54)(For UPS Line) |
| 13 | Renewal by Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour.(SD-56)(For 15A Power Plugs) |
| 14 | Renewal by supply and fixing of 4Feet x 2Feet x 1Feet GI Box on existing 63A Meter board with painting of suitable colour.(DATA-3) |
| 15 | GST@18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender