Tender For Provn Of 20 X Toilet And 05 X Bathroom For Transient Accn Of Tst Camp Of Age B/R And Age E/M Under Ge Tenga
Tender Value
36.60 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
11 days left
EMD
73200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of 20 X Toilet And 05 X Bathroom For Transient Accn Of Tst Camp Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil all as specified and directed. |
| 2 | Excavation in trenches n exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in hard/dense soil all as specified and directed. |
| 3 | All as per item No 2 above but exceeding 1.5 meter but not exceeding 3.00 mtr in depth complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D2(using 40mm graded aggregate) as in foundation filling and mass concrete etc all as specified and directed. |
| 5 | M & L for PCC (1:2:4) type B-2 (40 mm graded stone aggregate) Cement concrete in surface channels and drains with WPC 3% by weight of cement complete all specified and directed. Note :- WPC will be measured and paid sepretately under respective item. |
| 6 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed. |
| 7 | M&L for precast cement concrete solid building blocks (1:3:6), type C-1, 10 cm thick (with plain or interlocking joints as directed) setting in cement mortar (1:4) laying inner side of wall complete all as specified and directed. |
| 8 | M&L for MS TMT bars 10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed. |
| 9 | M&L for MS TMT bars 05mm dia and over, upto and including 10 mm dia in stirrups, spaces and binders all as specified and directed. |
| 10 | M&L for re-inforced cement concrete 1:2:4 type B-1 using (20mm graded aggregate) as in beams, plinth beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed. |
| 11 | Use & waste of flat Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete all as specified and directed. |
| 12 | M&L for Reinforcement cement concrete 1:2:4 type B1 using (20 mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. |
| 13 | Use & Waste of flat Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping, all as specified and directed. |
| 14 | M&L for Reinforcement cement concrete 1:2:4 type B0 using (12.5mmgraded aggregate) in Walls, retaining walls, basementwalls, ballast walls and the like;any thickness; above top of footings; including attachedpilaster and buttresses, all as specified and directed. |
| 15 | M&L for flat Formwork to faces of Baffle walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all specified and directed. |
| 16 | M&L for precast cement concrete, 1:2:4, type B1 (using 20mm graded stone aggregate) in cover slab for manhole and similar articles with plain faces and set in CM 1:6 complete all as specified and directed. |
| 17 | Supply only Integrated water proofing compound all as specified and directed. |
| 18 | M&L for Rendering 20mm thick on fair faces of brick work or concrete surface in cement plaster 1:4, with WPC 3% by weight of cement finished even and smooth without using extra cement completed all as specified and directed. Note :- WPC will be measured and paid sepretately under respective item. |
| 19 | M&L for rendering 15 mm thick in CM (1:4) over concrete wall surfaces finished even and smooth without using extra cement all as specified and directed. |
| 20 | M&L for newly plastered surfaces of walls and applying two coats of cement based paint, over a coat of primer complete all as specified and directed. |
| 21 | M&L for rendering 10 mm thick in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement all as specified and directed. |
| 22 | M&L for newly plastered surfaces of walls and applying two coats of oil bound distemper, over a coat of Alkali-resistant primer complete all as specified and directed. |
| 23 | M&L for hard core of gauge n.exc 63mm, deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface (broken stone and boulders) complete all as specified and directed. |
| 24 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as cement concrete in sub-bases floors and pavings etc complete all as specified & directed. |
| 25 | M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in sub base of floorings complete all as specified and directed. |
| 26 | M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles complete all as specified and directed. |
| 27 | M & L for Non-skid ceramic tiles 7 to 8 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.11 sqm but notexceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match all as specified & directed. |
| 28 | M & L for 10mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces finshed rough to receive tiles .all as specified and directed. |
| 29 | M & L for 350 x 250 x 7 mm/450 x 350 x 7 mm/300 x 200 x 7 mm thick glazed coloured ceramic tiles on vertical surface of wall set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade complete all as specified and directed. |
| 30 | S & F roof trusses (framed), trussed, purlines, crane grantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, plates etc confirming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 31 | M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new steel surfaces complete all as specified and directed. |
| 32 | S&F Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws all as specified and directed. |
| 33 | S&F for anodised aluminium snap grid of size 605X605 mm frame work for false ceiling with aluminium anodized section size, wall angle 40mm X25mmX2mm thk, main/cross tee-section 36.5 X 25 X 1.4mm and 23.5mm X 26.4mm 1.4mm and susupended with 6mm dia GI wire respectively with and including 8mm thk laminated Gypssum board fixed to aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer's instructions complete all as specified and as directed by Engineer -in-charge |
| 34 | S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying and fixing in opening all as specified and directed. |
| 35 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frame at site complete all as specified and directed. |
| 36 | S&F 100mm size stainless steel butt hinges, medium weight, cold rolled complete with stainless steel screw etc. all as specified as directed. |
| 37 | S& F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed all as specified and directed. |
| 38 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised all as specified and directed. |
| 39 | S & F Vitreous China Squatting pan 'Orissa pattern' size 580 x440 mm white with integral foot rest.all as specified and directed. |
| 40 | S&F vitreous china wash hand basin white flat back of size 550mmx400 mm including cutting for and pinning in end of brackets,32 mm waste fittings,brass chromium plated for glazed ware sinks,basins etc.with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed.and flush pipe of polytethylene of low or high density or PVC 32 mm dia complete all as specified and directed. |
| 41 | S & F 10 litres PVC, Syphonic action type, duel type Flushing cistern low level, white with inlet ball valve float and brackets complete all as specified and directed. |
| 42 | S&F PVC connections 15 mm size with PTMT nuts of length 450 mm all as specified and directed. |
| 43 | S&F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls all as specified and directed. |
| 44 | S&F PVC (SWR) junction single, (single T) equal or unequal with access door 110mm dia complete all as specified and directed. |
| 45 | S&F PVC (SWR) bends any radius, bend 110mm dia complete all as specified and directed. |
| 46 | S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 47 | S&F PVC (SWR) WC connector 110mm dia with lip ring all as specified and directed . |
| 48 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 49 | S&F PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints fixed to walls all as specified and directed. |
| 50 | S&F PVC (SWR) bends any radius with access door, 75mm dia all as specified and directed. |
| 51 | S&F 15 mm dia bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed. |
| 52 | S&F 15mm bore angle stop valves, fancy type chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions & fixed. all as specified and directed. |
| 53 | Supply and fix 15mm Pillar taps , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 54 | S& F Brass CP mixer 15 mm for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed. |
| 55 | S& F Brass Chromium plated shower roses 125mm with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed. |
| 56 | S & F Brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and directed. |
| 57 | S & F in looking mirror 600 mm x 450 mm bevelled edge mirror or selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 58 | M&L for 75 mm thick plain cement concrete type C-1, 1:3:6 using (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement all as specified and directed. |
| 59 | S & F framed work such as grills, gratting,framed brackets of angles or tees with web and flange cut to shape etc with ends of bars, shouldered and/or reveted, or forged into spikes, framed guard bars, framed works of water tankes stagging,gates and similar work con-forming to Fe.290.Gde-E-165. all as specified and directed. |
| 60 | S&F Rotational mounded polythene water storage tank of 1000 ltrs capacity, (multilayered, cylindrical, vertical with closed top) hoisted and fixed in position all as specified and directed. |
| 61 | S&F ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipes of 20 mm dia or brass ferrule and fixed all as specified and directed. |
| 62 | S&F Gun metal globe or gate valve with Iron wheel head, screwed both ends for 20 mm dia of pipe and fixed all as specified and directed. |
| 63 | S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes fixed to walls all as specified and directed . |
| 64 | S& F 20 mm bore galvanised steel tubes medium grade with all fittings for water supply pipes fixed to walls all as specified and directed. |
| 65 | M & L for 75 mm thick Cement concrete type D2 1:4:8 using (40mm graded aggregate) as in sub base, including form work complete all as specified and directed by Engineer-in-Charge. |
| 66 | M&L for 20 mm thick screed bed in CM 1:4 for laying floor tiles all as specified and directed . |
| 67 | M&L for Chequered cement concrete tiles 20cmx20cmx25mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry in floors completed all as specified and directed by Engr-in-Charge. |
| 68 | S&F Mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for Iron steps Fe-410-W (Gde.E-250) quality-A orFe 290 (Gde -E-165) complete all as specified and directed. |
| 69 | Loose filling with broken bricks aggregates of gauge 80 to 150 mm in sockage wells complete all as specified and directed. |
| 70 | M & L for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 100mm on after they are laid and tested complete all as specified and directed. |
| 71 | S&F PVC (SWR) pipe 150 mm bore single socketed, in any length with rubber ring joints, laid in trenches, wall or in floors complete all as specified and directed. |
| 72 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches including PVC insulated and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 73 | All as per item No. 72 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size complete all as specified and directed. |
| 74 | All as per item No. 72 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified & directed. |
| 75 | All as per item No. 72 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified & directed. |
| 76 | S&F Switch socket combination 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed. |
| 77 | S&F Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type complete all as specified and directed. |
| 78 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed. |
| 79 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 80 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified & directed. |
| 81 | Supply and fixing LED light fitting 1 x 10 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as specified and directed. |
| 82 | Supply and fix LED light fitting 1 x10W bulkhead luminaires inculding LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 83 | Supply and fix exhaust fan,PVC body AC single phase, 230V of size 250mm sweep heavy duty with blades, and frame and louvers complete all as specifed and directed. |
| 84 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 60 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 85 | Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre, BEE 5 star rated adjustable temprature setting 0-90 degree C complete with accessories such as safety wall, thermostate, NRV indication lamps, inlet outlet connections,air vent connections, connection pieces including all fixing arrangements such as fastners, bolts, nuts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge |
| 86 | Supply and fix sheet metal enclosures for DBs,double door when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board complete all as specified and directed. |
| 87 | S&F MCB SPN having breaking capacity 10KA, 'C' curve, 32 Amps, 240 V complete all as specified and directed. |
| 88 | S&F MCB SP having breaking capacity 10KA, 'C' curve, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 89 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 90 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out soil complete all as specified and directed. |
| 91 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 92 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 93 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning complete all as specified and directed. |
| 94 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete all as specified and directed . |
| 95 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 16 Sqmm 2 core complete all as specified and directed. |
| 96 | S&F GI tubing 50 mm dia grade in trench or on Wall/in Air/Poles for the protection of UG cable all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender