Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #58410511

Tender For Special Repair To Roof Treatment At Various Locations In Domestic Area At Afs Tezpur

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
48.20 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
6 days left
EMD
96400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Roof Treatment At Various Locations In Domestic Area At Afs Tezpur

BOQ

Name of Work:- SPECIAL REPAIR TO ROOF TREATMENT AT VARIOUS LOCATIONS IN DOMESTIC AREA AT AFS TEZPUR
Sl. No. Item Description
1M&L for providing the roof water proofing treatment in following steps: -(a) Removing of existing APP membrane on the substrate with using torch machine & heating and mechanicals tools for hacking the surfaces all as specified and directed.(b) Chipping & cleaning of surfaces with the help of wire brush, wash the roof with clean water & remove all loose concrete, grease, oil using wire brush and scrubber all as specified and directed.(c) Providing, mixing and applying polymer modified bond coat of Dr Fixit, pidicrete URP mix in the ration of 1:1 (URP 1 : Cement 1) by volume to make it lump free slurry when applied on the pre wet surface apply a single coat all as specified and directed.(d) Providing mixing and applying Dr Fixit pidicrete URP (301) SBR polymer (Styrene-Butadiene Rubber latex) (@ minimum 2% wt of cement used) modified cement concrete for structural members with ratio 1:2:3 (ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size with 25mm average thickness and finished the top surface without using extra cement all as specified and directed.
2Item 1.00 Contd....(e) Apply one coat of self primer 1 liter of Dr Fixit Roof seal classic (based on acrylate PU Hybrid Elastomeric emulsion technology reinforced with Nano fibers) diluted with 500 ml water in the ration 2:1 spreading at the rate of 0.80-10 /Sqm/Litre in the SSD (Saturate Surface Dry) condition. After 3 hours of primer application, apply 1st coat of Dr Fixit roof seal classic without dilution spreading at the reate of 0.500/Liter/Sqm/Coat until all surface is covered. Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90 degree to the first coat. Ensure there are no pinholes or air bubbles of the membrane surface. Apply secound coat of Dr Fixit roof seal classic without dilution spreading at the rate of 0.5 liter/Sqm/coat to achieve total dry film thickness of 1.00 mm at forced coverage at the rate of 1.00 litre/sqm in 2 coats meet the exceeds the ASTM D 6083-97a standard specification. Attains a Tensile strength of >2.1 N/sqmm with 45 GSM glass fiber mesh confirming to ASM D 412, Elongation at break > 300% and crack bridging ability upto 2mm., solar reflectance index as per ASTM E 1980-106, Air cure the coating for 7 day all as specified and directed.Note : (a) Work shall be carried out through manufacturer authorised applicator & contractor to submit MTC and test certificates alongwith gaurantee certificate from manufacturers.(b) Work shall be carried out upto 3rd floor roof of the building, Cost of necessary scaffolding and safety precautions shall be provided without any extra cost to the Govt.(c) Equivalent makes may also be user subject to prior approval of the GE.
3Demolition of existing cement concrete (un reinforced) in padding of roof slabs, covings of chajjas, including any type of tarfelt etc, roughening surfaces of old concrete roof slab/chajjas by picking, sweeping clean and washing down with water to remove dust, etc, brushing neat cement slurry with 3.0 kg of cement per sq metre and rendering 10mm thick cement plaster in cement mortar 1:3 mixed with water proofing compound as per manufacturers instruction over and including 25mm thick plain cement concrete type B0 (1:2:4) using 12.5 mm graded aggregates and including two coat of damp proof ultra through mechanical mean as directed by manufacturer complete. Make : Asian or equivalent make of Sika/fosroc/including all necessary scaffolding and safety measures complete all as specified and directed by Engineer-in-Charge.Note : (a) Work shall be carried out through manufacturer authorised applicator & contractor to submit MTC and and test certificates alongwith gaurantee certificate from manufacturer.(b) Work shall be carried out upto 3rd floor roof of the building, Cost of necessary scaffolding and safety precautions shall be provided without any extra cost to the Govt.
4Providing Plain cement concrete in 1:2:4, type B-0 using 12.5 mm graded crushed stone aggregates as in roof kerbs, benching rounded or chamfered on edge including rounded or chamfered edges with necessary form work etc, complete all as specified and directed.
5Disconnecting water tank from roof slab/staging upto triple story building, float valve with float arm and outlet pipe from PVC service water tank, empting, cleaning and removing all scales and dirt etc from tank and finally washing the internal surface with bleaching powder, closing wash outlet, refixing water tank in original position incl replacement of old tank nipple & GI union, including writing \\"Cleaned on dt___ and due date _____for cleaning, using paint , for tank capacity upto 500 litres, complete all as specified and as directed.
6Taking down steel 15mm dia tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed.
7Refixing 15mm old steel tubing with and including new GI fittings in new or old position on walls, complete all as specified and as directed.
8S & F 15mm dia steel water tubing medium grade galvanized with and including all fittings such as bend, tees , union etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
9Taking down steel 20mm dia tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed.
10Refixing 20 mm old steel tubing with and including new GI fittings in new or old position on walls, complete all as specified and as directed.
11S & F 20mm dia steel water tubing medium grade galvanized with and including all fittings such as bend, tees , union etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engr-in-Charge.
12S & F 500 Litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I with & including PTMT Float valve 20mm bore, Tank cover, wash out and overflow pipe necessary tank nipples and with writing date of installation and due date of cleaning and Taking down tanks from roof slab/ staging of upto triple story bldg, lowering, complete all as specified and as directed.
13Cutting & removing tree roots from any height of walls/roof including removal of trees, roots & grass vegetables upto 50 mtr away from bldg & making good to the damaged portion of walls in CM 1:4 or PCC 1:2:4 type B-1 surface area exc 400 sqcm & n exc 900 sqcm, complete all as specified and directed.
14M & L for extra over rendering or plastering 10mm thick in CM 1:3 on concrete surface/side of roof slab/Chajjas for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work, including cutting to edges, all mitres and stopped ends etc including two coat of damp proof ultra through mechanical mean as directed by manufacturer complete including cleaning the existing surface, complete all as specified and directed
15S & F 1000 Litres capacity rotational moulded poly ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I with & including PTMT float valve 20mm bore, tank cover, wash out pipe, overflow pipe, tank nipple and with writing date of installation and due date of cleaning and taking down tanks from roof slab/ staging upto triple story bldg, lowering, complete all as specified and as directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58410511
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.20 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Roof Treatment At Various Locations In Domestic Area At Afs Tezpur
Basic Detail
Tender No 8223/E8
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 06 Nov 2026
Submission Date 25 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 48.20 Lakhs
Tender Fee 500
EMD 96400
Exemption Available
Document List
7ff66059-32d7-4db5-9912-ef053bdc6613.html
BOQ_894730.xls
TENDER8223.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

7ff66059-32d7-4db5-9912-ef053bdc6613.html

xls

BOQ_894730.xls

pdf

TENDER8223.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender