Tender For Special Repairs To Electrical Installations, Ac Units And Ups Arrangements In Taluk Office Building At Modakurichi In Erode District.
Tender Value
2.47 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
14 days left
EMD
2500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Erode → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Electrical Installations, Ac Units And Ups Arrangements In Taluk Office Building At Modakurichi In Erode District.
BOQ
| Sl. No. | Item Description |
| 1 | Renewal by supply and fixing of 3Nos. 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) (SD-142) (In A4 Section) |
| 2 | Renewal by supply and fixing of 20Amps DP plug and socket in sheet steel enclosure with 32A DP MCB in flush with wall with earth connection.[for AC Plug] [SD-144] (In Election Section and Computer Room) |
| 3 | Renewal by supply erection testing commissioning of 1.50TR (4500KCal/Hr) ABS Plastic split type Air Conditioner confirming to IS1391[Part 2] 1992 with Rotary compressor operating on refrigerant R-22/Non CFL suitable for wall mounting for operating on 230V 50HZ single phase AC supply with Five Star rating as per BEE Specification and capable of performing the following functions.A) Cooling, B) dehumidifying C) Air circulating D) Filtering the installation work for the above split type AC units includes the following. 1. Mounting /fitting indoor and outdoor units at their respective locations. 2. Laying refrigerant pipe line of 6mtrs distance and connecting the both units after drilling hole in the wall if required thickness of the copper tubing shall not be less than 0.80mm 3. Insulating the suction pipe with expanded polythene foam 5mm thick tubing. 4. Laying 15mm dia flexible PVC drain pipe of 6mtrs length to throw out the condensate water being formed in the indoor unit. 5. Leak testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 4mtrs length and up to switch within 3mtrs of location of indoor unit.(Make -Carrier/voltas /Blue star make only) (SOR M-1984) (In Computer Room) |
| 4 | Renewal by supply and fixing of 4KVA Automatic voltage stabilizer of wall mounting type with Automatic time delay switching arrangements suitable to operate on 230V Single phase supply.(SOR M 1988) (In Computer Room) |
| 5 | Renewal by supply and laying of 5/8'' and 3/8'' copper pipe (Extra beyond 3Mtrs supplied with AC Unit) (SOR M 1990) |
| 6 | Renewal by supply and fixing of angle iron stand for outdoor split A.C unit. (SOR M 1991) |
| 7 | Renewal by supply, Erection, Testing and Commissioning of uninterrupted Power supply (UPS) (Sine Wave) (Microteck/ Amaron/ Luminious/ Exide) unit of capacity 2KVA with input Voltage 12V DC Supply, Output Voltage 230V, 50HZ AC Supply with following accessories/ Circuits and with following accessories and with 2Hour of Battery backup at full load respectively. 1.Battery charging Device. 2.Inverter Circuit. 3.Over load as well as short circuit. 4.Indication for operations like Battery charging, overload, Low Battery etc. 5.Reset Switch - 1No. 6.Tall Tubular Battery - 2Nos of 12V AC IT500 150AH (Reputed make ) 7.Two layer Wooden/ Steel stand. (In Office Room) [ SOR - M-2106 ] |
| 8 | Renewal by supply, Erection, Testing and Commissioning of uninterrupted Power supply (UPS) (Sine Wave) (Microteck/ Amaron/ Luminious/ Exide) unit of capacity 1KVA with input Voltage 12V DC Supply, Output Voltage 230V, 50HZ AC Supply with following accessories/ Circuits and with following accessories and with 2Hour of Battery backup at full load respectively. 1.Battery charging Device. 2.Inverter Circuit. 3.Over load as well as short circuit. 4.Indication for operations like Battery charging, overload, Low Battery etc. 5.Reset Switch - 1No. 6.Tall Tubular Battery - 1Nos of 12V AC IT500 150AH (Reputed make ) 7.Two layer Wooden/ Steel stand. (In Election Section) [ SOR - M-2105 ] |
| 9 | Renewal by supply and run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour.(SD-347) (For Computer Plugs Set) |
| 10 | Renewal by supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour.(SD-56) (For 20A MC Plug and Socket) |
| 11 | Removal of out door units shifting and refixing the same with supply and run of copper pipe size ½’’, 1/4’’ and 5/8’’ insulator pipe for indoor and out door unit for the length of 10feet including charges for gas tap up and refixing service complete. [As Per Quotation Rate] (In Election Section) |
| 12 | Renewal by supply and fixing of 5A 3Pin and 2Pin Combined flush type wall socket on existing switch box with connection etc....[DATA-2 ] (In Election Section) |
| 13 | GST@18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender