Tender For Construction of Additional Accommodation To Girls Hostel For G.S.S. School At Kaza In Distt. Lahaul & Spiti (H.P.) {Sh: - Providing E.I., Solar Inverter And Solar Water Geyser, Fire Extinguisher Therein}
Tender Value
28.44 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
4 days left
EMD
56900
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lahul and Spiti → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction of Additional Accommodation To Girls Hostel For G.S.S. School At Kaza In Distt. Lahaul & Spiti (H.P.) {Sh: - Providing E.I., Solar Inverter And Solar Water Geyser, Fire Extinguisher Therein}
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group A |
| 3 | Group B |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 6 | Specification of LED fittings: |
| 7 | Wattage of LED fittings - As per following parameter. |
| 8 | Total lumens of the fittings - as per wattage |
| 9 | Diffuser - Polycarbonate diffuser/PMMA |
| 10 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 11 | Input frequency - 50 Hz + 1 Hz |
| 12 | Power factor - Minimum 0.90 |
| 13 | Luminaire efficacy - >100 lm/w |
| 14 | Color rendering index - CRI shall be greater than 80 |
| 15 | Working/ operating temperature - 00 to + 450c or better |
| 16 | Color temperature - 60000K + 10% |
| 17 | Electronic Driver |
| 18 | Drive current (LED) - As per OEM. |
| 19 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 20 | Type of driver - Constant current output driver |
| 21 | THD - Less than 10% |
| 22 | Surge Protection - 2.5 KV minimum |
| 23 | Efficiency Driver - >85% |
| 24 | Protection - Shall have under voltage and over voltage protection. |
| 25 | Warranty of LED fittings including LED driver - 5 years against manufacturing defect. |
| 26 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 27 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 28 | Life of LED - 25000 burning hours at 70% lumen maintenance |
| 29 | Lumen output of the fitting |
| 30 | LED Batten Light >2000Lumens. |
| 31 | LED Batten Light >1000Lumens. |
| 32 | S/E of LED Panel with PDC body and polycarbonate /Acrylic diffuser to be mounted in recess The job includes carriage, erection, making connections testing and commissioning of the fittings.2 * 2 feet |
| 33 | Specification of LED fittings: |
| 34 | Wattage of LED fittings - As per following parameter. |
| 35 | Total lumens of the fittings - as per wattage |
| 36 | Diffuser - polycarbonate/acyrlic diffuser UGR <30 |
| 37 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 38 | Input frequency - 50 Hz + 1 Hz |
| 39 | Power factor - Minimum 0.90 |
| 40 | Luminaire efficacy - >110 lm/w |
| 41 | Color rendering index - CRI shall be greater than 80 |
| 42 | Working/ operating temperature - 00 to + 450c or better |
| 43 | Color temperature - 60000K + 10% |
| 44 | Electronic Driver |
| 45 | Drive current (LED) - As per OEM. |
| 46 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 47 | Type of driver - Constant current output driver |
| 48 | THD - Less than 10% |
| 49 | Surge Protection - 2.5 KV minimum |
| 50 | Efficiency Driver - >85% |
| 51 | Protection - Shall have under voltage and over voltage protection. |
| 52 | Warranty of LED fittings including LED driver - 5 years against manufacturing defect. |
| 53 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 54 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 55 | Life of LED - 50000 burning hours at 70% lumen maintenance |
| 56 | Lumen output of the fitting |
| 57 | LED Panel Light 2'x2' >3960Lumens. |
| 58 | S/E of LED Downlighter Surface type square with polycarboante body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 59 | Specification of LED fittings: |
| 60 | Wattage of LED fittings - As per following parameter. |
| 61 | Total lumens of the fittings - as per wattage |
| 62 | Diffuser - Polycarbonate diffuser. |
| 63 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 64 | Input frequency - 50 Hz + 1 Hz |
| 65 | Power factor - Minimum 0.90 |
| 66 | Luminaire efficacy - >85 lm/w |
| 67 | Color rendering index - CRI shall be greater than 80 |
| 68 | Working/ operating temperature - 00 to + 450c or better |
| 69 | Color temperature - 60000K + 10% |
| 70 | Electronic Driver |
| 71 | Drive current (LED) - As per OEM. |
| 72 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 73 | Type of driver - Constant current output driver |
| 74 | THD - Less than 15% |
| 75 | Surge Protection - 2.5 KV minimum |
| 76 | Efficiency Driver - >85% |
| 77 | Protection - Shall have under voltage and over voltage protection. |
| 78 | Warranty of LED fittings including LED driver - 5 years against manufacturing defect. |
| 79 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 80 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 81 | Life of LED - 25000 burning hours at 70% lumen maintenance |
| 82 | Lumen output of the fitting |
| 83 | LED Down Light >425Lumens. |
| 84 | LED Down Light >1700Lumens. |
| 85 | S/E of LED bulk head IP 66 rated with aluminium body/PDC housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 86 | Specification of LED fittings: |
| 87 | Wattage of LED fittings - As per following parameter. |
| 88 | Total lumens of the fittings - as per wattage |
| 89 | Diffuser - Polycarbonate diffuser/PMMA |
| 90 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 91 | Input frequency - 50 Hz + 1 Hz |
| 92 | Power factor - Minimum 0.90 |
| 93 | Luminaire efficacy - >80 lm/w |
| 94 | Color rendering index - CRI shall be greater than 80 |
| 95 | Working/ operating temperature - 00 to + 450c or better |
| 96 | Color temperature - 60000K + 10% |
| 97 | Electronic Driver |
| 98 | Drive current (LED) - As per OEM. |
| 99 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 100 | Type of driver - Constant current output driver |
| 101 | THD - Less than 10% |
| 102 | Surge Protection - 2 KV minimum |
| 103 | Efficiency Driver - >85% |
| 104 | Protection - Shall have under voltage and over voltage protection. |
| 105 | Warranty of LED fittings including LED driver - 5 years against manufacturing defect. |
| 106 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 107 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 108 | Life of LED - 50000 burning hours at 70% lumen maintenance |
| 109 | Lumen output of the fitting |
| 110 | LED Bulk Head >800Lumens. |
| 111 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 112 | Providing and installation of following type of LED retrofit lamp B-22 holder base with polycarbonate body and aluminium heat sink; suitable for input voltage: AC 220-240 V, 50/60Hz, including mounting in existing fixture, testing etc. as required complete in all respects. |
| 113 | LED retrofit lamp 9/10 Watt. |
| 114 | S/E of LED FLOOD LIGHT IP65 with IK07 protection industrial with weather-proof, pressure die cast & powder coated aluminium housing.The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 115 | Specification of LED fittings: |
| 116 | Wattage of LED fittings - As per following parameter. |
| 117 | Total lumens of the fittings. -as below |
| 118 | Diffuser -Polycarbonate diffuser/PMMA |
| 119 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 120 | Input frequency - 50 Hz + 1 Hz |
| 121 | Power factor - Minimum 0.90 |
| 122 | Luminaire efficacy ->100 lm/w |
| 123 | Color rendering index-CRI shall be greater than 70 |
| 124 | Working/ operating temperature - 00 to + 450c or better |
| 125 | Color temperature - 60000K + 10% |
| 126 | Electronic Driver |
| 127 | Drive current (LED)-As per OEM. |
| 128 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 129 | Type of driver - Constant current output driver |
| 130 | THD -Less than 10% |
| 131 | Surge Protection -4 KV minimum |
| 132 | Efficiency Driver->85% |
| 133 | Protection-Shall have under voltage and over voltage protection. |
| 134 | Warranty of LED fittings including LED driver - 5 years against manufacturing defect. |
| 135 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 136 | LED Type/ Make/ Model-Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 137 | Life of LED-25000 burning hours at 70% lumen maintenance |
| 138 | Lumen output Of fitting |
| 139 | LED Flood Light >5500Lumens. |
| 140 | Providing and installation exhaust fan of following sizes in the existing opening, Double ball bearing type metal frame including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: of Approved Make Domestic type. |
| 141 | Exhaust Fan, Light duty, (Domestic) 150 mm sweep |
| 142 | Exhaust Fan, Light duty, (Domestic) 225/230 mm sweep |
| 143 | Providing and fixing of Iron shutter for all sizes exhaust fans in the existing opening, including installation at site etc. as required to the best satisfaction of Engineer-in-Charge. |
| 144 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 145 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 146 | 5/6 amps switch |
| 147 | 3 pin 5/6 A socket outlet |
| 148 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 149 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 150 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 151 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 152 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For Computer plugs to be used in non residential buildings). |
| 153 | Providing and installation of instant Electric water heater (Geyser) of various sizes with 8 bar pressure rating 3kw element and safety valve installation by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- |
| 154 | 6 Liter capacity water heater (Cat-A) |
| 155 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes with 8 bar pressure rating Five star BEE rating and safety valve installation by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required. |
| 156 | 25 Liter capacity water heater (Cat-A) |
| 157 | 35 Liter capacity water heater (Cat-A) |
| 158 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 159 | Armoured cable 35 sq. mm (3.5 core) |
| 160 | Providing, laying and fixing of one No. DWC ( Double walled corrugated ) HDPE Pipe for Power cable protection of high grade direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering and jointing together by Snap-fit coupler with rubber ring complete with connection etc. as required to complete the job to the entire satisfaction of EIC. |
| 161 | 63 mm dia. |
| 162 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 163 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 164 | Supplying and fixing of following size Jindal make G.I. Pipe Medium B-class direct in ground to be laid below the ground level along with all accessories etc. of the required size. Make:- JINDAL, TATA or any other approved by Engineer-in-Charge. |
| 165 | 50-mm ( 2\\") dia. G.I. Pipe, Medium class |
| 166 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 167 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 168 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 169 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 170 | 4 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 171 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 172 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 173 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 174 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 175 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 176 | Single pole 6 Amp. |
| 177 | Single pole 10 Amp. |
| 178 | Single pole 16 Amp. |
| 179 | Single pole 25 Amp. |
| 180 | Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required. |
| 181 | 40 A DP |
| 182 | Supplying and fixing following rating, follwing pole, (single phase and neutral), 240/415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 183 | 40 A DP |
| 184 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 185 | 6 way , Double door |
| 186 | 8 way , Double door |
| 187 | 12 way , Double door |
| 188 | 16 way Double Door |
| 189 | S/E of MCCB Amp. 4 Pole 415 Volt. with Thermal Magnetic Release for overload and short circuit protection 36 kA breaking Capacity (Ics=100% Icu with positive isolation) with/ without Spreader/ Rotary Handle. |
| 190 | MCCB 40- 100 Amp. 36 ka 4 Pole Release without rotary handle |
| 191 | Providing & fixing and installation of MCCB Enclosure for Thermal Magnetic Release 4 Pole MCCB having IK08 and IP30 Protection with mounting holes for easy wall mounting and Louvers for better heat dissipation complete with installation. Make:- L&T, ABB, Legrand or any other approved by Engineer-in-Charge. |
| 192 | MCCB 4 Pole Enclosure. |
| 193 | Supplying and fixing TP&N copper bus-bar chamber suitable for 415 volts capacity with 4 No. copper strip bus-bars each of length and x-section suitable for following current carrying capacities, enclosure made of sheet steel having thickness of 1.6mm, dust protected, duly powder painted with detachable gland plate and other accessories including drilling holes on the board, making connections, earthing etc. as required. |
| 194 | 63 A Copper Busbar Chambers 15\\" (SS Enclosure) |
| 195 | 100 A Copper Busbar Chambers 15\\" (SS Enclosure) |
| 196 | Providing and fixing of following type Kit-kat Rewireable (Porcelain Fuse carrier & Base) fuse suitable for input voltage 415 V, 50/60Hz, complete in all respect as required:- Make: L&T, Havells or any other approved by Engineer-in-Charge. |
| 197 | Kit-Kat Fuse 63 Amp. 220 Volt |
| 198 | Kit-Kat Fuse 100 Amp. 415 Volt |
| 199 | Supplying and fixing wooden boxes of following sizes (nominal size) on surface or in recess suitable for fixing meter/Kit-kat in front including painting etc. as required. |
| 200 | Wooden Box 203mm.x 254mm.x60mm. Deep |
| 201 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 202 | 20 mm |
| 203 | Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, in sheet steel enclosure, with side handle operation, including drilling holes on the board, making connections, etc. as required:- |
| 204 | 63 amps. TPN, On Load Change over switch (SS Enclosure type) |
| 205 | Supply Installation testing and commissioning of 25 KVA/20Kwp Hybrid solar Photovoltic power plant conforming to MNRE specification as amended, consisting of Mono/Poly Crystalline silicon solar cells, net-metering facility, necessary protection againts Surge and Lightening, sufficient number of earthing, mounted on rooftop with Aluminium/GI structure of suitable strength with following components with 24 months warranty complete as required at site. Make:- Tata, Waaree, Intra Solar,Fuji, Livgaurd, Exide, Havells, Luminous or any other approved by Engineer-in-Charge. |
| 206 | a) Solar Photovoltaic Module DCR, 600 Wp or above of 10.8KW capacity, ALMM approved, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part- 2. Solar Photovoltaic Module conversion efficiency shall not be less than 20.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Make: Make : Amaze/ Luminous/ Servotech/Vikram/Eastman etc |
| 207 | b) Power Conditioning Unit (PCU) |
| 208 | Power Conditioning Unit (PCU) of 350-800 VDC Input voltage range and 400 VAC 3 -PHASE SOLAR HYBRID INVERTER 25KVA/20KW/240Vdc, Inbuilt Galvanic Isolation Transformer • Export Excess\ Power Generated & Also Get Backup • In-built Zero Export Function • Advanced DSP Control • IGBT Based Rectifier • Surge protection on Grid side & PV side. |
| 209 | Open circuit Voltage: 500 V; Maximum PV power: 10.8kW, MPPT Charge Controller, MPPT range:300 - 480 V; Input supply: 415 VAC, 3 Phases, 4 wire (+15%, -15%); Battery Voltage: 240 VDC, Battery Type: Lithium ion battery |
| 210 | Output waveform:Pure Sine wave; Output Nominal Voltage:415VAC ±2%, 3P; Output Frequency:50Hz ±1%; Load Power Factor: 0.6 lag to 1(within kVA and KW rating),Peak Efficiency:90% |
| 211 | Protection:Input Under and Over voltage, Input Under and Over Frequency, Output Overload, Output short circuit, Output over and Under voltage, Over Temperature, Array Reverse Polarity, Battery Over and Under voltage |
| 212 | Charging current from grid: 15A For 150Ah battery Battery or, as required by any other battery (upto 50% kW rated capacity of Inverter) |
| 213 | c) Battery: maintenance free Litium ion Battery for Battery bank of 240V x 150 Ah deep (150 Ah of 15 No. ) cycle batteries. Make : Amaze/ Luminous/Exide/Servotech/Eastman. Note : 5 Year Manufaturing warrenty |
| 214 | d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable alongwith glands, lugs and other accessories etc. as required. |
| 215 | e) Lightening and surge voltage protection |
| 216 | f)Earthing for inverter, structure and Lightening arrestor. Minimum 6 number of earthing. |
| 217 | g) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit alongwith supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 218 | i) Data Monitoring System complete with accessories as required. |
| 219 | The installation shall be Warrantyd for 60 months for complete work and equipments from the date of satisfactory handing over of the site as certified by the Department/Consultant/Client after correction of faulty/bad workmanship, defective design, manufacturing defects in works. The contractor shall Warranty the works to maintain quality on the basis of design/scheme i.e. 60 months |
| 220 | Supplying, Installation, Testing, Commissioning of following capacity Evacuated Tube Collector (ETC) Solar Water Heating System comprising of all glass ETC tube absorber. The inner layer of absorber shall be of solar selected absorbing coated tube, Vacuum jacket, cover glass tube, getter and getter mirror surface, as per IS 16543. The system shall have temperature gauges, strainer, 2 nos. water meters, Suitable capacity cold and hot water tank, all MS structure for installation including suitable electric control panel complete with control and power wiring, necessary pluming including piping for cold and hot water line between tank and solar water system, water heater and thermostat including non-return valve, float valve and other valve etc. as required. The various component shall have following specification.1. The Absorber area i.e. the number, dimension and thickness of solar evacuated tube as per IS:16544 clause 5.4 and IS: 16543 clause 4.22. Boro Silicate Glass 3.3 for cover plat as per ISO: 3585.3. |
| 221 | The material for three target coating shall be aluminum nitrate, aluminum nitrate stainless steel and copper multi layer selecting coating as per IS: 16543.4. Manifold shall be of Mild steel section with PP coating and Inner material shall be of SS 304.5. Recommended operating pressure:10 Bars.6. The capacity of hot water tank shall be minimum 1.5 times the rated capacity system. Inner Material shall be Stainless Steel SS 316 b) as per IS 1730 grade SS304-2B (22SWG). The hot water tank shall be insulated with high density injected PUF insulation 50 mm thickness between inner and outer tank. Tank stand shall be of mild steel and shall be design to withstand wind velocity of 100km/hours (minimum) or more as per site. 7. Suitable nos. ISI Marked electrical heaters along control panel, with suitable breaker, all protections, and all safety provisions so as to achieve 60 °C temperature rise in an hour. The range of thermostat shall be upto 80 °C. Make:- Recold, Tata, AO Smith, Jaquar or any other approved by Engineer-in-Charge.including 5 year warranty. |
| 222 | Providing & fixing of IS marked (IS:15683) portable fire extinguisher, carbondioxide (CO2) BC-type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill with CO2 gas confirming to IS:15222 filled to a filling ratio of not more than 0.667 and wall suspension bracket. (ISI MARK) Make:- Minimax, Ceasefire, Atasee, Lifeguard or anyother approved by the Engineer in Charge |
| 223 | Powder Type CO2 ( 4.5 Kg.Capacity) |
| 224 | Providing and fixing Water Stored Pressure type fire extinguishers Capacity 9 Ltr.consisting of seamless cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. ( ISI MARKED) . Make:- Minimax, Ceasefire, Atasee, Lifeguard or anyother approved by the Engineer in Charge |
| 225 | Water Stored Pressure Type ( 9Ltr.Cap) |
| 226 | Providing & Fixing 4 Kg. ABC MAP-50% Powder type fire extinguishers are manufactured and marked to Indian standard IS: 15683. Hose shall made of EPDM Rubber, CE Marked Valve, Suitable first aid appliance for fighting fires in Class A, B & C fire that is wood, textile, flammable liquids & gases.Make:- Minimax, Ceasefire, Atasee, Lifeguard or anyother approved by the Engineer in Charge |
| 227 | 4Kg.Capacity ABC Powder Type ( MAP-50%) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender