| Sl. No. | Item Description |
| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or salimar pattern roof coverings, etc. complete all as specified and as directed. |
| 2 | S&F Pre painted galvalume aluminum zinc coating GI based corrugulated steel sheet of 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, etc. complete all as specified and as directed. |
| 3 | S&F Pre painted galvalume aluminum zinc coating GI based plain steel sheet of 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, etc. complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description, etc. complete all as specified and as directed. |
| 5 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A), etc. complete all as specified and as directed. |
| 6 | Refixing only steel truss, rafter and purlin of different size bend to shape, cut to length etc, including necessary welding, special shape washer, etc. complete all as specified and as directed. |
| 7 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets of any thickness including cover fillet, etc. complete all as specified and as directed. |
| 8 | Dismantling of timber scantlings 40 Sqcm and over in section, in any position from framed work, etc. complete all as specified and as directed. |
| 9 | S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection n.exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size19mmx19mmX0.36 mm Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, as per manufacturer's instruction, etc. complete all as specified and as directed.Make : Everest or equvalent as approved by GE. |
| 10 | Dismantling of boarding of any description fixed in any position with nails/screws, etc. complete all as specified and as directed. |
| 11 | S&F 20mm thick 2nd class planed soft wood for facia boarding with but joints and champhered matched with one side of the boarding, etc. complete all as specified and as directed. |
| 12 | Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions, arches, pillars etc but excluding ashler facing dressed stone work and precast concrete, etc. complete all as specified and as directed. |
| 13 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, etc. complete all as specified and as directed. |
| 14 | M&L for brick work with sub-class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, etc. complete all as specified and as directed. |
| 15 | Taking down cement plaster on brick or stone masonry surfaces of walls including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 16 | M&L for 10 mm thick rendering in cement mortar 1:6 on other than fair faces of stone masonry, brick work and rendering finished even and smooth without using extra cement, etc. complete all as specified and as directed. |
| 17 | M&L for 15 mm thick rendering ( in two coats 10mm+5mm) on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall and finished even and fair mixed with integral water proofing compound @ 2% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated, etc. complete all as specified and as directed.Note:-WPC will be measured and paid separately as supply only. |
| 18 | Supply only integral water proofing compond, etc. complete all as specified and as directed. |
| 19 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent), etc. complete all as specified and as directed. |
| 20 | M&L for preparation of old plastered surfaces of wall and applying two coats of oil bound distemper, etc. complete all as specified and as directed. |
| 21 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer, etc. complete all as specified and as directed. |
| 22 | M&L for preparation of old decorated surfaces of walls, chajjas and applying two coats of cement base paint, etc. complete all as specified and as directed. |
| 23 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, etc. complete all as specified and as directed. |
| 24 | M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, etc. complete all as specified and as directed. |
| 25 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing near cement slurry @3 Kg per sqm, etc. complete all as specified and as directed. |
| 26 | M&L for 7 to 8 mm thick non skid ceramic coloured tiles (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar 1:6, etc. complete all as specified and as directed. |
| 27 | M&L for 350x 250x 7 mm or 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM 1:4 finished even and rough, etc. complete all as specified and as directed. |
| 28 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above ground level), etc. complete all as specified and as directed. |
| 29 | M&L for 75 mm thick cement concrete type C-2 (1:3:6) (using 40 mm graded stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, etc. complete all as specified and as directed. |
| 30 | M&L for PCC type B2 (1:2:4) (using 20mm graded stone aggregates) as in surface channels, drains including all necessary form work, extra etc. complete all as specified and as directed. |
| 31 | M&L for preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, etc. complete all as specified and as directed. |
| 32 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, etc. complete all as specified and as directed. |
| 33 | Taking down chowkhats or frame n.exc 1.50 sqm each without taking off shutters from the frame, etc. complete all as specified and as directed. |
| 34 | Taking down Chowkhats or frames exc 1.5 sqm but n.exc 4.00 sqm each without taking off shutters from the frame, etc. complete all as specified and as directed. |
| 35 | S&F Pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges, lock, strike plate, etc. complete all as specified and as directed. |
| 36 | S&F 35 mm thick second class hard wood, plain, framed panelled shutters of any number of panels, with panels of 12 mm thick timber flat on both sides feather edged, or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers and the dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I, etc. complete all as specified and as directed. |
| 37 | S&F 35 mm thick second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, wire mesh, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass, wire mesh and fitted to chowkhats and the dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I), etc. complete all as specified and as directed. |
| 38 | S&F Powder Coated Aluminium anodised frame for doors, windows, ventilators minimum thickness of powder coating 50 micron with one or more rebates including joining cleat for fixing, etc. complete all as specified and as directed. |
| 39 | S&F Power Coated Aluminium anodised window and ventilator shutters of any colour and the thickness of fixed type without sash bar and powder coating not less than 50 micron and aluminium section weighing 0.55 kg/m, including necessary joining cleats, glazing clips, rubber neoprene packing, 2 Nos of Aluminium handles and tower bolts in each door/shutter including necessary hinges, aluminium anodised snap beading and lucking arrangement, screws, etc. complete all as specified and as directed. |
| 40 | S&F Aluminium anodised grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening and weight not less than 3.4 kg/Sqm, etc. complete all as specified and as directed. |
| 41 | M&L for providing and fixing steel roller for Aluminium sliding window with necessary screws, etc. complete all as specified and as directed. |
| 42 | S&F 4 mm thick Sheet glass of ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane, etc. complete all as specified and as directed. |
| 43 | S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.50 sqm in each pane, etc. complete all as specified and as directed. |
| 44 | M&L for PCC type C-1 (1:3:6) (using 20 mm graded stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including necessary form work, etc. complete all as specified and as directed. |
| 45 | S&F 0.63mm nominal dia galvanised mild steel wire cloth and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, etc. complete all as specified and as directed. |
| 46 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube fixing in opening as per specification & drawing, etc. complete all as specified and as directed. |
| 47 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement fixing in the frame at site as per specification & drawing, etc. complete all as specified and as directed. |
| 48 | S&F 100mm size butt hinges of medium weight mild steel cold rolled, etc. complete all as specified and as directed. |
| 49 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section and fixed with screws, etc. complete all as specified and as directed. |
| 50 | S&F 150 mm size Aluminium handles of cast type and fixed with screws, etc. complete all as specified and as directed. |
| 51 | S&F 300 mm long aluminium alloy anodised sliding door bolts with haps staple (bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed with screws, etc. complete all as specified and as directed. |
| 52 | S&F 75 mm size butt hinges of medium weight mild steel cold rolled, etc. complete all as specified and as directed. |
| 53 | S&F 125 mm size Aluminium handles of cast type and fixed with screws, etc. complete all as specified and as directed. |
| 54 | S&F 100 mm long aluminium anodised barrel tower bolt of extruded section and fixed with screws, etc. complete all as specified and as directed. |
| 55 | S&F in repair water closet (squatt pattern) of vitreous china squatting pan \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syponic pipe ect complete including trap set in and including necessary lean cement concrete, etc. complete all as specified and as directed. |
| 56 | S&F in repairs Vitrous china wash down water closet pan pedestal pattern white, exlcuding fixing bolts, flushing cistem & Flush pipe including PVC Seat Cover white recess bottom type mild steel chromium plated or aluminium hanging device including dismantling existing EWC, etc. complete all as specified and as directed. |
| 57 | S&F in repairs fancy type CP Health faucet (ABS Body) suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS, wall hook including making connections and fixed in position, etc. complete all as specified and as directed. |
| 58 | S&F in repairs PVC high level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required including disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, etc. complete all as specified and as directed. |
| 59 | S&F in repairs Vitreous China wash basin, flat back, size 550x400mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets and waste coupling of 40mm bore dia brass, chromium plated with long screwed shanks, plugs (waste) with rings and fly nuts, flange end bedded in red lead cement and other end fixed, etc. complete all as specified and as directed. |
| 60 | S&F Brass CP Basin mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed, etc. complete all as specified and as directed. |
| 61 | S&F in repairs 15 mm bore fancy type CP bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, etc. complete all as specified and as directed. |
| 62 | S&F in repairs angle 15 mm bore fancy type CP stop valve with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, etc. complete all as specified and as directed. |
| 63 | S&F in repairs 125 mm size Brass CP shower rose with arm including fixing to steel pipe or union, etc. complete all as specified and as directed. |
| 64 | S&F 2 in 1 System-FLR fancy type CP wall mixer with Provision for Overhead shower with 115 mm Long Bend pipe, etc. complete all as specified and as directed by Engr-in-Charge.Make:Jaquar or equivalent |
| 65 | S&F in repair 15 mm bore PVC connection of 450 mm long with two brass chromium plated brass nuts and PVC washers, etc. complete all as specified and as directed. |
| 66 | S&F in repairs 100mm dia CP Gratings, etc. complete all as specified and as directed. |
| 67 | S&F in repairs fancy type CP Soap dish fixed to plugs with chromium plated brass screws, etc. complete all as specified and as directed. |
| 68 | S&F in repairs fancy type brass CP Tubular towel rail of 20 mm dia D' type 60cm long between flanges, etc. complete all as specified and as directed. |
| 69 | S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, etc. complete all as specified and as directed. |
| 70 | S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror, etc. complete all as specified and as directed. |
| 71 | Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, etc. complete all as specified and as directed. |
| 72 | S&F 15 mm bore GI tubes of medium grade including all GI fitting such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug and fixed to wall and ceiling or laid in/on floor, etc. complete all as specified and as directed. |
| 73 | Refixing of 15 mm old GI steel tubing including all GI fitting such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug and connections in new or old position of walls, ceiling, floors or laid in/on floor, etc. complete all as specified and as directed. |
| 74 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, etc. complete all as specified and as directed. |
| 75 | Taking up or down 20 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, etc. complete all as specified and as directed. |
| 76 | S&F 20 mm bore GI tubes of medium grade including all GI fitting such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug and fixed to wall and ceiling or laid in/on floor, etc. complete all as specified and as directed. |
| 77 | Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site as directed by Engineer-in-Charge, etc. complete all as specified and as directed. |
| 78 | S&F 110 mm bore PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, etc. complete all as specified and as directed. |
| 79 | S&F 75 mm bore PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, etc. complete all as specified and as directed. |
| 80 | S&F 110 mm bore PVC (SWR) bend of any radius with access door, etc. complete all as specified and as directed. |
| 81 | S&F 75 mm bore PVC (SWR) bend of any radius with access door, etc. complete all as specified and as directed. |
| 82 | S&F 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, etc. complete all as specified and as directed. |
| 83 | S&F 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, etc. complete all as specified and as directed. |
| 84 | S&F in repairs 75 mm bore PVC (SWR) floor trap plain including jointing with solvent cement, etc. complete all as specified and as directed. |
| 85 | Fixing olny Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays towall or roof, etc. complete all as specified and as directed. |
| 86 | S&F 1mm thick Mild steel sheet eaves gutters for 150mm dia , galvanised class 3, half round with rounded edges , etc. complete all as specified and as directed. |
| 87 | S&F Stop ends (for spigot or socket ends) 1mm thick Mild steel sheet eaves gutters for 150mm dia , etc. complete all as specified and as directed. |
| 88 | S&F 25mm dia decorative type curtain rod (curtain rails) of stainless steel (SS-304 grade) including suitable selective choice decorative knobs and brackets fixed with wall flange and screws including takingdown existing curtain rods, etc. complete all as specified and as directed by Engr-in-Charge. |
| 89 | S&F in repair of small fittings such as brackets of any type latch and hinge block, shaped door window stops and the like in second class hard wood article n.exc 200 cucm each, etc. complete all as specified and as directed. |
| 90 | S&F in repairs floor door stopper of brass body and tongues with hard drawn steel spring, overall length cover plate 140 mm, etc. complete all as specified and as directed. |
| 91 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, etc. complete all as specified and as directed. |
| 92 | M&L for Pre-cast RCC type B-1 (1:2:4) (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 including necessary formwork, etc. complete all as specified and as directed.Note: Reinforcement shall me measured and paid for separately. |
| 93 | S&F 10 mm dia and over TMT bars cut to length bent to shape as required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, etc. complete all as specified and as directed. |
| 94 | M&L for 75mm thick PCC type C-1 (1:3:6) (using 20 mm graded stone aggreate) as in sub-base, etc. complete all as specified and as directed. |
| 95 | M&L for Pre-plished coloured Chequered cement concrete tiles of 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors includig 20mm thick screed bed in CM (1:6), etc. complete all as specified and as directed. |
| 96 | Taking down unserviceable copper/aluminium point wiring of any description, including all associated fittings such as switches, socket outlets, switch-socket combinations, lamp holders, ceiling roses, regulators, etc., and making good the disturbed surfaces of walls, floors, etc., to match the existing finishes, etc. complete all as specified and as directed. |
| 97 | M&L for point wiring with 1.5 Sq.mm PVC insulated and un-sheathed single core FRLSH copper cable of 1100 volts grade, multi-stranded conductor, drawn through and including PVC casing and capping not less than 20 mm size (medium grade) fixed on surface with all necessary accessories, along with continuous 1.5 Sq.mm PVC insulated FRLSH copper earth wire connected to common earth dolly, including providing and fixing of modular type PVC surface box of suitable size complete with modular frame (grid) and cover plate, making good disturbed surfaces, complete for light/call bell point controlled by one switch, etc. complete all as specified and as directed. |
| 98 | Description all as per item No 97.00 here-in-efore but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent board, etc. complete all as specified and as directed. |
| 99 | Description all as per item No 97.00 here-in-efore but for one switch socket outlet 15/16 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable, etc. complete all as specified and as directed. |
| 100 | S&F 6A Modular switch 1 way, 1 module 230 Volts,50Hz, ISI marked, etc. complete all as specified and as directed. |
| 101 | S&F 16A Modular switch 1 way, 1 module 230 Volts,50Hz, ISI marked, etc. complete all as specified and as directed. |
| 102 | S&F 6A Socket, 2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, etc. complete all as specified and as directed. |
| 103 | S&F 6A/16A Socket, 2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, etc. complete all as specified and as directed. |
| 104 | S&F 65 X 50 mm Ceiling rose of surface bakelite three terminal, etc. complete all as specified and as directed. |
| 105 | S&F Lamp Holder insulated body with back plate for batten fitting, etc. complete all as specified and as directed. |
| 106 | S&F 15W LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink, etc. complete all as specified and as directed.CAT Part No : LHLDDDBNL5R015 of Havells or Equivalent of Crompton/Philips. |
| 107 | S&F 20W LED batten surface / wall mounted with extruded aluminium box type housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 20W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) with operating range of 150-270 V AC, etc. complete all as specified and as directed. |
| 108 | S&F 36W recessed type LED Panel Light of 600 mm × 600 mm size suitable for operation on 140–270 V AC supply, complete with powder coated die-cast aluminium housing, high quality glare free diffuser, independent electronic driver duly wired up to terminal block and all fixing accessories. The fitting shall have minimum system efficacy ≥100 lm/W, PF ≥0.90, CRI ≥80, THD ≤10%, IP20 protection, 6500K CCT, beam angle 120°, flicker ≤5%, instant start, inbuilt surge protection ≥3 kV and minimum life ≥35,000 burning hours, complete with internal connections, testing and commissioning in all respects, etc. complete all as specified and as directed. |
| 109 | S&F 35W LED building security light fitting 230V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including G.I pipe bracket, bracket mounting clamp with nuts & bolts, etc. complete all as specified and as directed. |
| 110 | S&F 10W LED bulkhead light with system efficiency of ≥90 lumens/W, Ingress protection IP 66, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria with range 150-270V AC all as per specified and directed.pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt, PF>0.95, etc. complete all as specified and as directed. |
| 111 | Taking down existing sub main wiring of any type and size laid in surface/recessed on wall/ceiling including removing from saddles, conduits, etc. complete all as specified and as directed. |
| 112 | M&L for sub main wiring along with earth wire of size two run of 4 sq mm + one run of 4 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLSH including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof, etc. complete all as specified and as directed.(Note:Three run of 4 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length |
| 113 | M&L for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLSH including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof, etc. complete all as specified and as directed.Note:Three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length. |
| 114 | Dismantling of distribution boards (DBs) and making good the disturbed surfaces to match existing finishes, etc. complete all as specified and as directed. |
| 115 | S&F TPN DB suitable for 4 Pole (TPN) MCB incomer, double door type (IP-43), 4-way, complete with 100 Amps rated insulated busbars, neutral link and earth bar, suitable for 415 Volts, 3 phase, 4 wire, 50 Hz AC supply, flush or surface mounted as required, including all accessories and interconnections, etc. complete all as specified and as directed. |
| 116 | S&F sheet metal enclosure, double door type (IP-43), SPN Distribution Board, duly phosphatised and powder coated, complete with 100 Amps rated copper busbar, neutral link and earth bar, 8-way, suitable for 240 Volts, single phase, 50 Hz AC supply, flush or surface mounted as required, including all accessories and interconnections, etc. complete all as specified and as directed. |
| 117 | S&F 415 Volts, 10 kA, ‘C’ curve, 4 Pole (TPN) MCB of 32 Amps rating, in TPN DB, complete with connections, testing and commissioning, etc. complete all as specified and as directed. |
| 118 | S&F 240 Volts, 10 kA, ‘C’ curve, Double Pole (DP) MCB of 40 Amps rating in SPN DB, including connections, testing and commissioning, etc. complete all as specified and as directed. |
| 119 | S&F 240 Volts, 10 kA, ‘C’ curve, SP MCB of 5–32 Amps rating in MCB DB, complete with connections, testing and commissioning, etc. complete all as specified and as directed. |
| 120 | S&F DBOX type MCB protected socket comprising PVC insulated enclosure with inbuilt plug top and socket, complete with 01 No. SP MCB of 20/25 Amp rating, C curve, suitable for 220–240 Volts AC supply, including making necessary electrical connections, testing and commissioning, etc. complete all as specified and as directed. |
| 121 | Taking down unserviceable electric water heater (Geyser), storage type steel body with copper inner tank upto 25/50/100 litre capacity, repairing the same including replacement/checking of heating element, thermostat, safety valve and internal wiring, refixing in original position, reconnecting water and electrical connections, testing and depositing unserviceable parts to MES Store, etc. complete all as specified and as directed. |
| 122 | S&F 25 litre capacity electric water heater (Geyser) storage type steel body with copper inner tank and heating element upto 2 KW, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc including taking down old u/s Geaser & deposit to MES Store, etc. complete all as specified and as directed. |
| 123 | S&F Exhaust fan made of sturdy engineering plastic, AC single phase, 230V, of 250 mm sweep, complete with blades, frame and louvers, including all fixing arrangements, wiring connections including taking down of old/unserviceable exhaust fan and depositing the same to MES Store, etc. complete all as specified and as directed. |
| 124 | M&L for repair of earthing complete with galvanised steel earth plate electrode of size 600 × 600 × 6 mm, buried directly in ground at a depth not less than 2.25m below ground level, with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire of 4 mm dia by means of galvanised iron/steel bolts, nuts, check nuts and washers, and connected to equipment as directed, including providing funnel with GI medium grade watering pipe of 20 mm bore with wire mesh, charcoal or coke and common salt in alternate layers of 150 mm compacted thickness all around the earth electrode, complete with PCC type C-1 (1:3:6) chamber and 50 mm thick precast RCC type B-1 (1:2:4) cover slab reinforced with 8 mm dia deformed bars at 150 mm centre to centre with suitable handle of 10 mm dia round bar, including GI medium grade pipe for protection of earth lead, complete with necessary excavation in soft/loose soil and disposal of excavated earth to a distance not exceeding 50 m, including dismantling of existing earthing and testing on completion, complete all as shown on Electrical Plate No. 3 of MES SSR Part-I, etc. complete all as specified and as directed. |
| 125 | Taking out old unserviceable underground cable of any size and type from trenches, walls, roofs, etc., for necessary repairs, replacement or re-laying works, etc. complete all as specified and as directed.Note: Excavation and earthwork shall be measured and paid for separately. |
| 126 | M&L for providing, laying, testing and commissioning of XLPE insulated, PVC bedded, galvanised steel strip/wire armoured, 1100 Volts grade heavy duty power cable with stranded aluminium conductor of size 16 sq mm, 4 core, laid in ground/on wall/air as required, including supply and fixing of suitable glands, lugs, nuts, bolts and washers at both ends, complete with all connections, testing and commissioning, etc. complete all as specified and as directed. |
| 127 | Excavation in trenches/ foundation in soft/ loose soil n.exc. 1.5 metre wide and n.exc. 1.50m deep for LT underground cable/pole foundation and getting out including forming bottom surface to required level or slope, etc. complete all as specified and as directed. |
| 128 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in thickness, etc. complete all as specified and as directed. |
| 129 | Removing excavated material n.exc 50 metres and depositing the same where directed at a level n.exc 1.5m above the starting point, etc. complete all as specified and as directed. |
| 130 | Supply and laying of sand cushioning to underground cables with consolidated thickness layer of sand 8 cm thick below the cable and 15 cm thick above the cable in trenches, including punning/ramming to achieve a total compacted thickness of 18 cm, etc. complete all as specified and as directed. |
| 131 | M&L for providing Sub-Class ‘B’ bricks of standard size for covering of cables, laid dry flat in trenches, etc. complete all as specified and as directed. |
| 132 | S&F 40 mm dia GI steel pipe of light grade for laid in trenches or underground/under floor/under road or fixed to pole for protection of cable/earth strip, including clamps with nuts, bolts and washers, etc. complete all as specified and as directed. |
| 133 | Excavating in post holes or similar holes in loose/soft soil each n.exc 0.50 cubic metre, including getting out the excavated material, returning, filling in, and ramming earth or broken rubble mixed with earth in layers n.exc 25 cm thickness, including disposal of surplus excavated soil to a distance n.exc 50m, and making good the disturbed surfaces, etc. complete all as specified and as directed. |
| 134 | M&L for providing and laying PCC, type C-2 (1:3:6) (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, including mixing, placing, compacting, levelling, and finishing the surface, etc. complete all as specified and as directed. |
| 135 | Taking out/dismantling existing unserviceable 20 to 25 mm nominal bore GI/PVC pipes including bends, tees, elbows, unions, valves and all other fittings, from trenches, walls, floors or any other location, etc. complete all as specified and as directed. |
| 136 | M&L for providing and laying 25 mm bore GI tubing of medium grade with all necessary fittings such as bends, tees, sockets, unions, clamps, and accessories, laid in trenches or fixed to wall/ceiling with suitable supports, including cutting, threading, jointing, and testing, etc. complete all as specified and as directed. |
| 137 | M&L for providing and laying 20 mm bore GI tubing of medium grade with all necessary fittings such as bends, tees, sockets, unions, clamps, and accessories, laid in trenches or fixed to wall/ceiling with suitable supports, including cutting, threading, jointing, and testing, etc. complete all as specified and as directed. |
| 138 | S&F 2000 litres capacity rotational moulded polyethylene water storage tank (vertical cylindrical, closed top) of, including all necessary fittings such as inlet, outlet, overflow, washout pipe, tank nipple, and locking arrangement, complete in all respects, fixed in position including taking down, etc. complete all as specified and as directed. |
| 139 | M&F for cutting, screwing, threading and fixing of GI tubing of 25 mm and 32 mm bore for alterations or additions to existing pipe lines, etc. complete all as specified and as directed. |
| 140 | S&F 25mm Gun metal gate valve with iron wheel head, screwed at both ends suitable for connection including jointing, testing and making leak-proof connections, etc. complete all as specified and as directed. |
| 141 | S&F 20mm Gun metal gate valve with iron wheel head, screwed at both ends suitable for connection including jointing, testing and making leak-proof connections, etc. complete all as specified and as directed. |
| 142 | S&F 25mm High-pressure PVC float valve with polythene float and fly nuts, screwed type suitable for connection with iron pipe or PVC ferrule including making necessary connections, adjustments and testing for proper operation, etc. complete all as specified and as directed. |
| 143 | M&L for angles, flat iron, fixed independently and interconnected with welding work, without the use of connecting plates, cut to required lengths as indicated, for water tank staging or similar structural works, conforming to Fe 410-W (Grade E-250), Quality-A steel, including dismantling of old/unserviceable existing staging, etc. complete all as specified and as directed. |
| 144 | M&L for providing hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 20 cm thick, watered and rolled/rammed to a true surface including filling of moorum/red bajri, etc. complete all as specified and as directed. |
| 145 | M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces and finished even and smooth without using extra cement, etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 146 | M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces and finished even and smooth without using extra cement, etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender