Tender For Tender**: Construction Of 220/132/33 Kv Ais Substation Raipur (Bhagwanpur), Roorkee Along With Its Associated Transmission Lines
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Dec 2026
30 days left
EMD
3.13 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tender**: Construction Of 220/132/33 Kv Ais Substation Raipur (Bhagwanpur), Roorkee Along With Its Associated Transmission Lines
BOQ
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 220/132/33 KV AIS Substation Raipur (Bhagwanpur), Roorkee along with its associated transmission lines” Contract No: PTCUL/E-Tender/C&P-II/SS-24/2026-27 |
| 2 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI. No. Item Description Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 3 | Price Schedule-A (Supply ) for (Construction of 220/132/33kV AIS Substation Raipur, Roorkee ) |
| 4 | Transformers |
| 5 | 160MVA, 220/132/11kV, Three phase Transformer including first filling of oil and Fibre Optic Temperature Measurement System and complete with all associated accessories. |
| 6 | 80MVA, 132/33kV, Three phase Transformer including first filling of oil and Fibre Optic Temperature Measurement System and complete with all associated accessories. |
| 7 | Online DGA Multigas type for above transformers. |
| 8 | Nitrogen Injection Fire Prevention & extinguishing system for above transformers. |
| 9 | Oil Storage Tank (15KL) |
| 10 | Oil sampling Bottle (Stainless Steel) 2ltrs capacity. |
| 11 | LT Transformers |
| 12 | 630kVA, 33/0.433kV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil) |
| 13 | 245kV Equipments |
| 14 | 245kV SF6 Circuit breakers (3 Ph.), 50kA |
| 15 | 245kV (5 Core) Current Transformer (1 Ph.) |
| 16 | For Line, BC, TBC |
| 17 | For Transformer |
| 18 | Junction box for above CT |
| 19 | 245kV Capacitive Voltage Transformer (1 Ph.) |
| 20 | Junction box for above CVT |
| 21 | 245kV Isolators (3-phase) |
| 22 | Isolator with one E/S |
| 23 | Isolator with two E/S |
| 24 | Isolator without E/S (Tandem) |
| 25 | 216kV Surge Arrestors |
| 26 | 245kV Bus Post Insulators |
| 27 | Hardware |
| 28 | Insulator strings, Disc Insulators, Hardware, conductor, 4\\" IPS Aluminium tube, bus-bar material, cable trays, clamps, connectors, earthwire, earthing material etc. for the following |
| 29 | 220kV |
| 30 | Line Bay |
| 31 | Transformer Bay |
| 32 | Transfer Bus Coupler Bay |
| 33 | Bus Coupler Bay |
| 34 | Bus Works (for 2Nos. Main Bus & 1No. Transfer Bus) |
| 35 | 145kV Equipment |
| 36 | 145kV SF6 Circuit breakers (3 Ph.), 40kA |
| 37 | 145kV (5 Core) Current Transformer (1 Ph.) with Junction Box |
| 38 | For Line feeder |
| 39 | For 220kV Transformer LV |
| 40 | For 132kV Transformer HV |
| 41 | 145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box |
| 42 | Isolators 145kV (3-phase) |
| 43 | Isolator with E/S |
| 44 | Isolator without E/S |
| 45 | Isolator without E/S (Tandem) |
| 46 | 120kV Surge Arrestors |
| 47 | 145kV Bus Post Insulators |
| 48 | Hardware |
| 49 | Insulator strings, Disc Insulators, Hardware, conductor, 4\\" IPS Aluminium tube, bus-bar material, cable trays, clamps, connectors, earthwire, earthing material etc. for the following |
| 50 | 132kV |
| 51 | Line Bay |
| 52 | Transformer Bay (220kV LV & 132kV HV) |
| 53 | Bus Coupler Bay |
| 54 | Bus Works (for Main & Transfer Bus ) |
| 55 | 33kV Equipments |
| 56 | 33kV Isolator (3-Ph), 25kA |
| 57 | Without E/S |
| 58 | With E/S |
| 59 | 33kV Circuit Breaker |
| 60 | Current Transformer |
| 61 | 33kV Current Transformer (single phase) for Transformer |
| 62 | 33kV Current Transformer (single phase) for Line and Bus Coupler |
| 63 | Junction Box for above CTs |
| 64 | 30kV Surge Arrestor |
| 65 | 33kV PT (single phase) |
| 66 | Junction Box |
| 67 | 33kV Bus Post Insulators/Solid core insulator |
| 68 | 33 kV HG fuse set |
| 69 | 2*5 MVAR Capacitor Bank |
| 70 | 33kV Circuit Breaker |
| 71 | 33kV Isolator with earth link |
| 72 | 33kV Isolator without earth link |
| 73 | Single phase Reactor |
| 74 | 33kV NCT |
| 75 | 33kV CT |
| 76 | 33kV Control and relay panel |
| 77 | Insulator strings, Disc Insulators, Hardware, conductor, 4\\" IPS Aluminium tube, bus-bar material, cable trays, clamps, connectors, earthwire, earthing material etc. for the following |
| 78 | 33kV 1 Main + 1 Transfer |
| 79 | Line bay |
| 80 | Transformer Bay 33kV |
| 81 | Bus Coupler Bay |
| 82 | Bus Works for Main Bus (including Sectionalizer Isolator) & Transfer Bus |
| 83 | Capacitor Bank |
| 84 | Substation Automation System |
| 85 | Complete Substation Automation System including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications |
| 86 | Bay Control Units |
| 87 | 220kV system |
| 88 | 132kV system |
| 89 | 33kV system |
| 90 | AC Kiosks |
| 91 | 220kV system |
| 92 | 132kV system |
| 93 | 33kV system |
| 94 | Online Monitoring, Data Acquisition and ABT Analysis System |
| 95 | ABT Meters 0.2S Class with TCP/IP, Optical Communication Ports (ABT Meters shall be mounted on the respective C&R Panel) |
| 96 | DCU & Accessories along with 2 Nos. 4G/5G Data enable SIM |
| 97 | Industrial Grade Network Switch -8 Port, unmanaged |
| 98 | UPS 2 KVA online with 30 Min back up on 100% load |
| 99 | Workstation: Application & Database server |
| 100 | Database - Microsoft SQL Server Edition (Latest) |
| 101 | MS office - Standard edition (Latest) |
| 102 | MacAfee Virus Scan Enterprise Desktop Edition (Latest) - 3 year |
| 103 | Local Energy Monitoring Software - Professional edition |
| 104 | LAN cable (average one roll per S/S 300 Meters) Cat-06 |
| 105 | PVC conduit Pipe - 3/4\\" ISI Mark |
| 106 | Enclosure for LAN Switch |
| 107 | SDH/MUX EQUIPMENT |
| 108 | Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input |
| 109 | SDH (STM-4 upgradable upto STM-16)/MUX base 19\\" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply. |
| 110 | OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs |
| 111 | SFP module to support upto 50 km |
| 112 | SFP module to support upto 100 km |
| 113 | Optical Amplifier/Booster equipment |
| 114 | OFC Patch Cords - (Set of 12 Nos.) |
| 115 | Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces) |
| 116 | Minimum 8 Port E1 interface card |
| 117 | Minimum 8 Port 4w E&M Interface card |
| 118 | Minimum 12 Port FXO interface card |
| 119 | Minimum 10 Port FXS interface card |
| 120 | Minimum 4 Port programmable data interface card |
| 121 | Integrated Teleprotection card (4 Commands each) |
| 122 | Engineering Order Wire Phone |
| 123 | Optical Fibre Cable for above OPGW communication |
| 124 | 220 kV Control and Relay panel |
| 125 | Circuit Breaker Control Panel |
| 126 | With Auto Reclose |
| 127 | With out Auto Reclose |
| 128 | Line Protection Panel (Main 1+Main 2) |
| 129 | Bus Bar Protection Panel (Bay-Segrigated Decentralised Scheme, Bay unit shall be installed in respective C&R Panel and Central Unit shall be installed in a separate Busbar panel) |
| 130 | 220kV (Bus Bar protection) Panel for Main-1 and Main-2 |
| 131 | Transformer Protection Panel 220/132 kV HV Side |
| 132 | 132 kV Control and Relay panel |
| 133 | Circuit Breaker Control Panel |
| 134 | With Auto Reclose |
| 135 | With out Auto Reclose |
| 136 | Line Protection Panel |
| 137 | Transformer protection panel |
| 138 | For 220/132kV LV side |
| 139 | For 132/33kV HV side |
| 140 | Other/common equipments |
| 141 | Time synchronisation equipment /GPS Clock (to be installed in SAS Panel) |
| 142 | PLCC for 220KV Line Feeder |
| 143 | Line Traps |
| 144 | 2000A, 0.5 mH/1.0 mH, 50kA |
| 145 | Coupling device ( Phase to Phase ) |
| 146 | HF Cable |
| 147 | Carrier Equipment (for speech+protection and for speech+Data) |
| 148 | Protection Coupler |
| 149 | PLCC for 132KV Line feeder |
| 150 | Line Traps |
| 151 | 2000A, 0.5 mH/1.0 mH, 40kA |
| 152 | Coupling device ( Phase to Earth ) |
| 153 | HF Cable |
| 154 | Carrier Equipment (for speech+protection and for speech+Data) |
| 155 | Protection Coupler |
| 156 | 33kV Control and Relay Panel |
| 157 | 33kV Tripple Feeder Control and Relay Panel |
| 158 | Testing & Maintenance Equipment |
| 159 | Insulation Tester Meter 15kV Multirange (Motorized) |
| 160 | Automatic capacitor and Tan Delta measuring kit |
| 161 | Digital Multi meter |
| 162 | Leakage tester (Tong type) |
| 163 | Selective level meter |
| 164 | Signal generator |
| 165 | Micro-ohm meter |
| 166 | Gapless Zinc Oxide LA tester |
| 167 | Oil BDV Kit 0-100 KV |
| 168 | Gas Evacuating and refilling Plant |
| 169 | Winding Resistance Meter |
| 170 | Thermal Imaging Camera |
| 171 | Gas Leakge Monitor |
| 172 | Circuit Breaker Analyser |
| 173 | Dew Point Meter |
| 174 | Battery Earth Fault Locator |
| 175 | Primary Injection Set |
| 176 | Relay Test Kit |
| 177 | D-Spanner set, Ring-Spanner set & Torque Wrench set. Each set shall be a complete set including all standard sizes. |
| 178 | Insulating Gloves & Helmets |
| 179 | Hydraulic Ladder Battery Operated (Rechargable) upto 300kg capacity & 10 Mtrs height |
| 180 | Spliced ladders 5mtr. & 10mtr. Each |
| 181 | Spliced ladders 20mtr. |
| 182 | Polyamide or Braided white nylon rope -12 mm, 14 mm & 20 mm of each type |
| 183 | Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements |
| 184 | Shock treatment chart & artificial respiratory system |
| 185 | First-aid box complete with first filling of required medicines, instruments and tools |
| 186 | Danger / Man on line / Break-Down boards of appropriate size |
| 187 | Rain coat, Gum boot and Safety Harness Belt with adequate straps |
| 188 | Air-conditioner |
| 189 | Split AC with cassette type indoor unit (Capacity-2T) Max Star rating |
| 190 | Miscellaneous items |
| 191 | Air Curtain for Control Room Building |
| 192 | Interactive Screen for Control Room Building |
| 193 | Bay Marshalling Kiosk (BMK) |
| 194 | LT Switchboard |
| 195 | 415V Main Switchboard |
| 196 | 415V AC Distribution Board |
| 197 | 415V MLDB |
| 198 | 415V ELDB |
| 199 | 220V DCDB |
| 200 | 48V DCDB |
| 201 | Batteries |
| 202 | 220V, 500AH |
| 203 | 48V, 300AH |
| 204 | Battery charger system |
| 205 | 220V, 100Amps Float Cum Boost Charger |
| 206 | 48V, 60Amps Float Cum Boost Charger |
| 207 | 250kVA, 440V DG set alongwith AMF Control panel |
| 208 | Fire Prevention & Extinguishing System |
| 209 | Fire Detection and Alarm System for Control Room Building and AC Kiosk |
| 210 | 45Ltrs Water Mist & CAFS |
| 211 | 45Ltr. Foam Type |
| 212 | 20Kg CO2 Type |
| 213 | 4.5kg CO2 type for outdoor kiosk |
| 214 | 6 Fire Bucket with stand |
| 215 | Sand Drum (half size) filled with sand |
| 216 | Fire Hut and sand pit |
| 217 | Illumination system |
| 218 | Switchyard lighting (LED Type Lights) with mounting accessories |
| 219 | Indoor Light LED Type for Control Room Building, Offices, Store Room and Kiosk |
| 220 | Street Lighting, LED Lights |
| 221 | Solar light system for street light (LED Type Lights) with Pole and other mounting accessories |
| 222 | 1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc. |
| 223 | Power Cables Aluminium (XLPE) |
| 224 | 3.5cx400 Sq.mm |
| 225 | 3.5cx300 Sq.mm |
| 226 | Power cable Aluminium (PVC) |
| 227 | 3.5cx70Sq.mm |
| 228 | 3.5cx35Sq.mm |
| 229 | 4cx16 Sq.mm |
| 230 | 4cx6 Sq.mm |
| 231 | Control cable Copper (PVC) |
| 232 | 2Cx2.5Sq.mm |
| 233 | 4Cx2.5Sq.mm |
| 234 | 6Cx2.5Sq.mm |
| 235 | 10Cx2.5Sq.mm |
| 236 | Grounding/Earthing system |
| 237 | 40mm MS rod for earthmat |
| 238 | 3 mtr deep driven earth electrode 40mm dia |
| 239 | 3 meter deep pipe electrode (treated pit) |
| 240 | MS/GS Flat 75 x 12 mm |
| 241 | MS/GS Flat 50 x 6 mm |
| 242 | Steel structure |
| 243 | Lattice structure (Main Structures & Auxiliary Equipment Structures) |
| 244 | Pipe structure (Auxiliary Equipments Structure) |
| 245 | Mandatory spares as per Annexure-\\"Mandatory Spares for AIS\\" |
| 246 | 220/132/33kV, 160MVA Transformer |
| 247 | 132/33kV, 80MVA Transformer |
| 248 | 245kV CB |
| 249 | 245kV Isolator & ES |
| 250 | 245kV CT |
| 251 | 245kV CVT |
| 252 | 198kV LA |
| 253 | 145kV CB |
| 254 | 145kV Isolator & ES |
| 255 | 145kV CT |
| 256 | 145kV CVT |
| 257 | 120kV LA |
| 258 | 33kV CB |
| 259 | 33kV Isolator & ES |
| 260 | 33kV CT |
| 261 | 33kV PT |
| 262 | 33kV LA |
| 263 | Control and Relay Panel |
| 264 | Substation Automation System |
| 265 | Illumination System |
| 266 | Fire Protection System |
| 267 | DG Set |
| 268 | Battery |
| 269 | Battery Charger |
| 270 | LT switchgear |
| 271 | AC &Ventilation |
| 272 | Erection hardware |
| 273 | Optical fibre cable |
| 274 | Price Schedule-A (Supply ) for ( Construction of LILO of 132 kV Bhagwanpur-LSM line at proposed 220 kV Substation Raipur, Roorkee |
| 275 | Towers |
| 276 | Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of 132 kV D/C towers with cleat including Nut & Bolts. |
| 277 | For B type (2o-15o) |
| 278 | For C type (15o-30o) |
| 279 | 132 kV D/C lattice type Cable termination Tower |
| 280 | Fabrication, Galvanizing and Supply of complete 132 kV D/C lattice type towers with bolts & nuts, step bolts, pack washers, spring washers, D-shackles including Body & Leg Extensions. |
| 281 | B type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 282 | C type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 283 | 132 kV D/C lattice type Cable termination Tower |
| 284 | Supply of Galvanized templates |
| 285 | Template of B type tower including Bolts, Nuts & washers etc. (2 Nos.) |
| 286 | Template of C type tower including Bolts, Nuts & washers etc. (2 Nos.) |
| 287 | Template of lattice type cable termination tower including Bolts, Nuts & washers etc.(2 Nos.) |
| 288 | ACSR Panther Conductor |
| 289 | Design and supply of hardware Fittings |
| 290 | Single Tension fitting for ACSR Panther Conductor suitbale for 120 KN Disc Insulator |
| 291 | Double Tension fitting for ACSR Panther Conductor suitbale for 2x120 KN Disc Insulator |
| 292 | Pilot fitting suitable for ACSR Panther (70 KN Disc Insulator) |
| 293 | Tension fitting for GS Earth wire 7/10 SWG |
| 294 | PG Clamp suitable for Panther Conductor for LILO arrangments |
| 295 | Accessories for conductor & earth wire |
| 296 | Vibration damper for Panther Conductor |
| 297 | Flexible Copper Bond |
| 298 | Repair sleeve for ACSR Panther conductor |
| 299 | Mid span compression joint for ACSR Panther Conductor |
| 300 | Mid span compression joint for GS earth wire 7/10 SWG |
| 301 | Insulators |
| 302 | 132 kV, 120 KN porcelain Long rod Insualtor (01 No. 120 KN Porcelain long rod insulator for each Tension fitting) |
| 303 | 132 kV, 70 KN porcelain Long rod Insualtor (01 No. 70 KN Porcelain long rod insulator for each Tension fitting) |
| 304 | Supply of following tower accessories |
| 305 | Number plate |
| 306 | Danger Plate |
| 307 | Circuit Plate (set of two) |
| 308 | Phase Plate (set of three) |
| 309 | Anti-Climbing device |
| 310 | Pipe type earthing (Set of Two) |
| 311 | Supply of following items for aviation requirements |
| 312 | Span markers |
| 313 | Obstruction lights (to be provided as per IS 5613) |
| 314 | 1 Medium + 2 low intensity |
| 315 | 1 Medium + 4 low intensity |
| 316 | Supply of Wind Measuring Equipment |
| 317 | Supply of OPGW |
| 318 | OPGW 48 Fibre - 132 KV |
| 319 | All requiered hardware such as Tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 132 kV lines |
| 320 | Vibration Damper |
| 321 | Reinforcing rod |
| 322 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 323 | Approach Cable 48 Fibre |
| 324 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 325 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 326 | Price Schedule-A (Supply ) for ( Construction of 132 kV DC line through Underground Cable for LILO of 132 kV Bhagwanpur-LSM line\\" at 220/132/33 kV Substation Raipur, Roorkee ) |
| 327 | Design, manufacturing & supply of 132 kV 630 sq. mm. Single Core XLPE insulated Copper Cable ( 6+1 Spare ). |
| 328 | Supply of 3.3 KV 240 Sqmm. Sheath bonding Cable |
| 329 | Supply of Polymer type outdoor termination kit suitable for 132 kV 630 Sq.mm Copper Cable. |
| 330 | Supply of straight through joint/Cross bonding Joint suitable for 132 kV 630 sq. mm Cable |
| 331 | Three Phase earthing link box without SVL. |
| 332 | Single Phase earthing link box with SVL. |
| 333 | Single Phase earthing link box without SVL. |
| 334 | Supply of polymer type Lighting Arrester suitable for 132 kV 630 Sq.mm. cable with surge counter meter. |
| 335 | Supply of route marker (@ 50 Meter interval |
| 336 | Supply of HDPE Pipes (160 mm dia) |
| 337 | Supply of HDPE Pipes (75 mm dia) |
| 338 | Approach Cable 48 Fibre |
| 339 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 340 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 341 | Trefoil clamp |
| 342 | Pipe Earthing for termination kit & Lighting Arrester |
| 343 | Warning tape in buried trench |
| 344 | Supply of earth continuity Conductor of 1.1 KV 1Cx240 Sq. mm.(for earthing) |
| 345 | Supply of Ms flat 50x6 mm Earthing material |
| 346 | Supply of Ms round 40 mm for earthing (having 3 mtr. length) |
| 347 | Price Schedule-A (Supply ) for ( Construction of 220 kV DC Overhead line from 400/220 kV Substation Puhana to proposed 220 kV Substation Raipur, Roorkee ) |
| 348 | Towers |
| 349 | Supply of Utility Monopole |
| 350 | Design, Fabrication and supply of Galvanized 220 kV D/C Utility Monopole complete in all respect suitable for (2°-30°) Deviation angle. |
| 351 | Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of 220 kV D/C towers with cleat including Nuts & Bolt. |
| 352 | For B type (2o-30o) |
| 353 | For C type (30o-60o) |
| 354 | Fabrication, Galvanizing and Supply of complete 220 kV D/C lattice type towers with bolts & nuts, step bolts, pack washers, spring washers, D-shackles including Body & Leg Extensions. |
| 355 | B type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 356 | C type D/C tower including 3 mtr. 6 mtr. & 9 mtr Body Extension. |
| 357 | Supply of Galvanized templates |
| 358 | Template of B type tower including Bolts, Nuts & washers etc. (2 Nos.) |
| 359 | Template of C type tower including Bolts, Nuts & washers etc. (2 Nos.) |
| 360 | ACSR Zebra Conductor |
| 361 | Design and supply of hardware Fittings |
| 362 | Single Tension fitting for Single ACSR Zebra Conductor suitbale for 160 KN Disc Insulator |
| 363 | Double Tension fitting for Single ACSR Zebra Conductor suitbale for 2x160 KN Disc Insulator |
| 364 | Pilot fitting suitable for Single ACSR Zebra (90 KN Disc Insulator) |
| 365 | Accessories for conductor & earth wire |
| 366 | Vibration damper for Zebra Conductor |
| 367 | Flexible Copper Bond |
| 368 | Repair sleeve for ACSR Zebra conductor |
| 369 | Mid span compression joint for ACSR Zebra Conductor |
| 370 | Insulators |
| 371 | 220 kV, 160 KN porcelain Long rod Insualtor (02 No. 160 KN Porcelain long rod insulator for each Tension fitting) |
| 372 | 220 kV, 90 KN porcelain Long rod Insualtor (01 No. 90 KN Porcelain long rod insulator for each Supspension/Pilot fitting) |
| 373 | Supply of following tower accessories |
| 374 | Number plate |
| 375 | Danger Plate |
| 376 | Circuit Plate (set of two) |
| 377 | Phase Plate (set of three) |
| 378 | Anti-Climbing device |
| 379 | Pipe type earthing (Set of Two) |
| 380 | Supply of following items for aviation requirements |
| 381 | Span markers |
| 382 | Obstruction lights (to be provided as per IS 5613) |
| 383 | 1 Medium + 2 low intensity |
| 384 | 1 Medium + 4 low intensity |
| 385 | Supply of OPGW |
| 386 | OPGW 48 Fibre - 220 KV |
| 387 | All requiered hardware such as Tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 220 kV lines |
| 388 | Vibration Damper |
| 389 | Reinforcing rod |
| 390 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 391 | Approach Cable 48 Fibre |
| 392 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 393 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 394 | Price Schedule-A (Supply ) for ( Construction of 220 kV DC line through Underground Cable from 400/220 kV Substation Puhana to proposed 220/132/33 kV Substation Raipur, Roorkee ) |
| 395 | Design, manufacturing & supply of 220 kV 1000 sq. mm. Single Core XLPE insulated Copper Cable ( 6+1 Spare ). |
| 396 | Supply of 6.6 KV 300 Sqmm. Sheath bonding Cable |
| 397 | Supply of Polymer type outdoor termination kit suitable for 220 kV 1000 Sq.mm Copper Cable. |
| 398 | Supply of straight through joint/Cross bonding Joint suitable for 220 KV 1000 Sq.mm Cable |
| 399 | Three Phase earthing link box without SVL. |
| 400 | Single Phase earthing link box with SVL. |
| 401 | Single Phase earthing link box without SVL. |
| 402 | Supply of polymer type Lighting Arrester suitable for 220 KV 1000 Sq.mm. cable with surge counter meter. |
| 403 | Supply of route marker (@ 50 Meter interval |
| 404 | Supply of HDPE Pipes (225 mm dia) |
| 405 | Supply of HDPE Pipes (75 mm dia) |
| 406 | Approach Cable 48 Fibre |
| 407 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 408 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 409 | Trefoil clamp and connector |
| 410 | Pipe Earthing for termination kit & Lighting Arrester |
| 411 | Warning tape in buried trench |
| 412 | Supply of earth continuity Conductor of 1.1 KV 1Cx300 Sq. mm.(for earthing) |
| 413 | Supply of Ms flat 50x6 mm Earthing material |
| 414 | Supply of Ms round 40 mm for earthing (having 3 mtr. length) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 220/132/33 KV AIS Substation Raipur (Bhagwanpur), Roorkee along with its associated transmission lines” Contract No: PTCUL/E-Tender/C&P-II/SS-24/2026-27 |
| 415 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI.No. Description of Material Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 416 | Price Schedule-B (Erection) for (Construction of 220/132/33kV AIS Substation Raipur, Roorkee ) |
| 417 | Transformers |
| 418 | 160MVA, 220/132/11kV, Three phase Transformer including first filling of oil and Fibre Optic Temperature Measurement System and complete with all associated accessories. |
| 419 | 80MVA, 132/33kV, Three phase Transformer including first filling of oil and Fibre Optic Temperature Measurement System and complete with all associated accessories. |
| 420 | Online DGA Multigas type for above transformers. |
| 421 | Nitrogen Injection Fire Prevention & extinguishing system for above transformers. |
| 422 | LT Transformers |
| 423 | 630kVA, 33/0.433kV, three phase transformer including bushing, accessories and first filling of Oil (fresh oil) |
| 424 | 245kV Equipments |
| 425 | 245kV SF6 Circuit breakers (3 Ph.), 50kA |
| 426 | 245kV (5 Core) Current Transformer (1 Ph.) |
| 427 | For Line, BC, TBC |
| 428 | For Transformer |
| 429 | Junction box for above CT |
| 430 | 245kV Capacitive Voltage Transformer (1 Ph.) |
| 431 | Junction box for above CVT |
| 432 | 245kV Isolators (3-phase) |
| 433 | Isolator with one E/S |
| 434 | Isolator with two E/S |
| 435 | Isolator without E/S (Tandem) |
| 436 | 216kV Surge Arrestors |
| 437 | 245kV Bus Post Insulators |
| 438 | Hardware |
| 439 | Insulator strings, Disc Insulators, Hardware, conductor, 4\\" IPS Aluminium tube, bus-bar material, cable trays, clamps, connectors, earthwire, earthing material etc. for the following |
| 440 | 220kV |
| 441 | Line Bay |
| 442 | Transformer Bay |
| 443 | Transfer Bus Coupler Bay |
| 444 | Bus Coupler Bay |
| 445 | Bus Works (for 2Nos. Main Bus & 1No. Transfer Bus) |
| 446 | 145kV Equipment |
| 447 | 145kV SF6 Circuit breakers (3 Ph.), 40kA |
| 448 | 145kV (5 Core) Current Transformer (1 Ph.) with Junction Box |
| 449 | For Line feeder |
| 450 | For 220kV Transformer LV |
| 451 | For 132kV Transformer HV |
| 452 | 145kV Capacitive Voltage Transformer (1 Ph.), 4400pF with Junction Box |
| 453 | Isolators 145kV (3-phase) |
| 454 | Isolator with E/S |
| 455 | Isolator without E/S |
| 456 | Isolator without E/S (Tandem) |
| 457 | 120kV Surge Arrestors |
| 458 | 145kV Bus Post Insulators |
| 459 | Hardware |
| 460 | Insulator strings, Disc Insulators, Hardware, conductor, 4\\" IPS Aluminium tube, bus-bar material, cable trays, clamps, connectors, earthwire, earthing material etc. for the following |
| 461 | 132kV |
| 462 | Line Bay |
| 463 | Transformer Bay (220kV LV & 132kV HV) |
| 464 | Bus Coupler Bay |
| 465 | Bus Works (for Main & Transfer Bus ) |
| 466 | 33kV Equipments |
| 467 | 33kV Isolator (3-Ph), 25kA |
| 468 | Without E/S |
| 469 | With E/S |
| 470 | 33kV Circuit Breaker |
| 471 | Current Transformer |
| 472 | 33kV Current Transformer (single phase) for Transformer |
| 473 | 33kV Current Transformer (single phase) for Line and Bus Coupler |
| 474 | Junction Box for above CTs |
| 475 | 30kV Surge Arrestor |
| 476 | 33kV PT (single phase) |
| 477 | Junction Box |
| 478 | 33kV Bus Post Insulators/Solid core insulator |
| 479 | 33 kV HG fuse set |
| 480 | 2*5 MVAR Capacitor Bank |
| 481 | 33kV Circuit Breaker |
| 482 | 33kV Isolator with earth link |
| 483 | 33kV Isolator without earth link |
| 484 | Single phase Reactor |
| 485 | 33kV NCT |
| 486 | 33kV CT |
| 487 | 33kV Control and relay panel |
| 488 | Insulator strings, Disc Insulators, Hardware, conductor, 4\\" IPS Aluminium tube, bus-bar material, cable trays, clamps, connectors, earthwire, earthing material etc. for the following |
| 489 | 33kV 1 Main + 1 Transfer |
| 490 | Line bay |
| 491 | Transformer Bay 33kV |
| 492 | Bus Coupler Bay |
| 493 | Bus Works for Main Bus (including Sectionalizer Isolator) & Transfer Bus |
| 494 | Capacitor Bank |
| 495 | Substation Automation System |
| 496 | Complete Substation Automation System including hardware and software for the substation & remote control stations alongwith associated equipments as per Technical Specifications |
| 497 | Bay Control Units |
| 498 | 220kV system |
| 499 | 132kV system |
| 500 | 33kV system |
| 501 | AC Kiosks |
| 502 | 220kV system |
| 503 | 132kV system |
| 504 | 33kV system |
| 505 | Online Monitoring, Data Acquisitionand ABT Analysis System |
| 506 | ABT Meters 0.2S Class with TCP/IP, Optical Communication Ports (ABT Meters shall be mounted on the respective C&R Panel) |
| 507 | DCU & Accessories along with 2 Nos. 4G/5G Data enable SIM |
| 508 | Industrial Grade Network Switch -8 Port, unmanaged |
| 509 | UPS 2 KVA online with 30 Min back up on 100% load |
| 510 | Workstation: Application & Database server |
| 511 | Database - Microsoft SQL Server Edition (Latest) |
| 512 | MS office - Standard edition (Latest) |
| 513 | MacAfee Virus Scan Enterprise Desktop Edition (Latest) - 3 year |
| 514 | Local Energy Monitoring Software - Professional edition |
| 515 | LAN cable (average one roll per S/S 300 Meters) Cat-06 |
| 516 | PVC conduit Pipe - 3/4\\" ISI Mark |
| 517 | Enclosure for LAN Switch |
| 518 | Integration of station metering system with centrlized data system including all hardware and software required. |
| 519 | SDH/MUX EQUIPMENT |
| 520 | Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input |
| 521 | SDH (STM-4 upgradable upto STM-16)/MUX base 19\\" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply. |
| 522 | OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs |
| 523 | SFP module to support upto 50 km |
| 524 | SFP module to support upto 100 km |
| 525 | Optical Amplifier/Booster equipment |
| 526 | OFC Patch Cords - (Set of 12 Nos.) |
| 527 | Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces) |
| 528 | Minimum 8 Port E1 interface card |
| 529 | Minimum 8 Port 4w E&M Interface card |
| 530 | Minimum 12 Port FXO interface card |
| 531 | Minimum 10 Port FXS interface card |
| 532 | Minimum 4 Port programmable data interface card |
| 533 | Integrated Teleprotection card (4 Commands each) |
| 534 | Engineering Order Wire Phone |
| 535 | Optical Fibre Cable for above OPGW communication |
| 536 | 220 kV Control and Relay panel |
| 537 | Circuit Breaker Control Panel |
| 538 | With Auto Reclose |
| 539 | With out Auto Reclose |
| 540 | Line Protection Panel (Main 1+Main 2) |
| 541 | Bus Bar Protection Panel (Bay-Segrigated Decentralised Scheme, Bay unit shall be installed in respective C&R Panel and Central Unit shall be installed in a separate Busbar panel) |
| 542 | 220kV (Bus Bar protection) Panel for Main-1 and Main-2 |
| 543 | Transformer Protection Panel 220/132 kV HV Side |
| 544 | 132 kV Control and Relay panel |
| 545 | Circuit Breaker Control Panel |
| 546 | With Auto Reclose |
| 547 | With out Auto Reclose |
| 548 | Line Protection Panel |
| 549 | Transformer protection panel |
| 550 | For 220/132kV LV side |
| 551 | For 132/33kV HV side |
| 552 | Other/common equipments |
| 553 | Time synchronisation equipment /GPS Clock (to be installed in SAS Panel) |
| 554 | PLCC for 220KV Line Feeder |
| 555 | Line Traps |
| 556 | 2000A, 0.5 mH/1.0 mH, 50kA |
| 557 | Coupling device ( Phase to Phase ) |
| 558 | HF Cable |
| 559 | Carrier Equipment (for speech+protection and for speech+Data) |
| 560 | Protection Coupler |
| 561 | PLCC for 132KV Line feeder |
| 562 | Line Traps |
| 563 | 2000A, 0.5 mH/1.0 mH, 40kA |
| 564 | Coupling device ( Phase to Earth ) |
| 565 | HF Cable |
| 566 | Carrier Equipment (for speech+protection and for speech+Data) |
| 567 | Protection Coupler |
| 568 | 33kV Control and Relay Panel |
| 569 | 33kV Tripple Feeder Control and Relay Panel |
| 570 | Air-conditioner |
| 571 | Split AC with cassette type indoor unit (Capacity-2T) Max Star rating |
| 572 | Miscellaneous items |
| 573 | Air Curtain for Control Room Building |
| 574 | Interactive Screen for Control Room Building |
| 575 | Bay Marshalling Kiosk (BMK) |
| 576 | LT Switchboard |
| 577 | 415V Main Switchboard |
| 578 | 415V AC Distribution Board |
| 579 | 415V MLDB |
| 580 | 415V ELDB |
| 581 | 220V DCDB |
| 582 | 48V DCDB |
| 583 | Batteries |
| 584 | 220V, 500AH |
| 585 | 48V, 300AH |
| 586 | Battery charger system |
| 587 | 220V, 100Amps Float Cum Boost Charger |
| 588 | 48V, 60Amps Float Cum Boost Charger |
| 589 | 250kVA, 440V DG set alongwith AMF Control panel |
| 590 | Fire Prevention & Extinguishing System |
| 591 | Fire Detection and Alarm System for Control Room Building and AC Kiosk |
| 592 | 6 Fire Bucket with stand |
| 593 | Fire Hut and sand pit |
| 594 | Illumination system |
| 595 | Switchyard lighting (LED Type Lights) with mounting accessories |
| 596 | Indoor Light LED Type for Control Room Building, Offices, Store Room and Kiosk |
| 597 | Street Lighting, LED Lights |
| 598 | Solar light system for street light (LED Type Lights) with Pole and other mounting accessories |
| 599 | 1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded cable sealing, Lugs, Glands and straight joints, etc. |
| 600 | Power Cables Aluminium (XLPE) |
| 601 | 3.5cx400 Sq.mm |
| 602 | 3.5cx300 Sq.mm |
| 603 | Power cable Aluminium (PVC) |
| 604 | 3.5cx70Sq.mm |
| 605 | 3.5cx35Sq.mm |
| 606 | 4cx16 Sq.mm |
| 607 | 4cx6 Sq.mm |
| 608 | Control cable Copper (PVC) |
| 609 | 2Cx2.5Sq.mm |
| 610 | 4Cx2.5Sq.mm |
| 611 | 6Cx2.5Sq.mm |
| 612 | 10Cx2.5Sq.mm |
| 613 | Grounding/Earthing system |
| 614 | 40mm MS rod for earthmat |
| 615 | 3 mtr deep driven earth electrode 40mm dia |
| 616 | 3 meter deep pipe electrode (treated pit) |
| 617 | MS/GS Flat 75 x 12 mm |
| 618 | MS/GS Flat 50 x 6 mm |
| 619 | Steel structure |
| 620 | Lattice structure (Main Structures & Auxiliary Equipment Structures) |
| 621 | Pipe structure (Auxiliary Equipments Structure) |
| 622 | Support for Operation and Maintenance (O&M) of substation, Trouble shooting and familiarization of PTCUL staff with installed system for a period of Six (06) Months by deplyoing adequate number of qualified persons round the clock. |
| 623 | Price Schedule-B (Erection) for ( Construction of LILO of 132 kV Bhagwanpur-LSM line at proposed 220 kV Substation Raipur, Roorkee ) |
| 624 | Part - 1 |
| 625 | Survey |
| 626 | Detailed route Survey, Profiling, Alignment etc. including prepration of Tower schedule, Optimisation of tower locations etc and prepration of forest case (if any) complete in all respect |
| 627 | Check survey and final peg marking |
| 628 | Soil Investigation |
| 629 | Part - 2 |
| 630 | Setting of Stubs, inlcuding all foundation work but excluding the cost of concreting and excavation |
| 631 | B type Double Circuit (2o- 30o ) tower |
| 632 | C type Double Circuit (30o- 60o) tower |
| 633 | 132 kV D/C lattice type Cable termination Tower |
| 634 | Concrete for RCC type foundations including all material, shoring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for concrete (cost of supply of MS steel bar is not to be included) |
| 635 | M 20 (1:1.5:3) |
| 636 | M 10 (1:3:6) |
| 637 | Excavation of foundation pits including all earthwork, backfilling and levelling etc. |
| 638 | Super structure erection of various type of towers, tower part, tower extention (complete) with bolts & nuts and including all work above ground level excluding hoisting of insulators & fitting of danger plate, number plate, phase plate, circuit plate, anti climbing devices and bird guards, but including punching of bolts. |
| 639 | B type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 640 | C type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 641 | 132 kV D/C lattice type Cable termination Tower |
| 642 | Laying, Stringing, Tensioning, clamping, jointing etc. complete with Single ACSR Panther conductor including hoisting of insulators and fitting of vibration dampers etc. for complete route of D/C Single Panther. |
| 643 | Grounding work for Pipe type earthing including excavation and backfilling (Set of Two). |
| 644 | Tack welding on bolts and nuts on Ist section of towers |
| 645 | Fixing of tower accessories: |
| 646 | Danger plate |
| 647 | Number plate |
| 648 | Phase Plate (set of three) |
| 649 | Circuit Plate (set of two) |
| 650 | Anti-Climbing device |
| 651 | M.S. Steel bar for reinforcement |
| 652 | Installation of Avaition Items |
| 653 | Span markers |
| 654 | Obstruction lights (to be provided as per IS 5613) |
| 655 | 1 Medium + 2 low intensity |
| 656 | 1 Medium + 4 low intensity |
| 657 | Painting of Towers (As per IS:5613) |
| 658 | Erection of OPGW |
| 659 | Laying, Stringing Tensioning, clamping, jointing etc. complete with OPGW 48 Fibre - 132 kV and all requiered hardware such as Vibration damper, tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 132 kV lines |
| 660 | Reinforcing rod |
| 661 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 662 | Approach Cable 48 Fibre |
| 663 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 664 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 665 | Price Schedule-B (Erection) for ( Construction of 132 kV DC line through Underground Cable for LILO of 132 kV Bhagwanpur-LSM line\\" at 220/132/33 kV Substation Raipur, Roorkee ) |
| 666 | Detailed Survey, Laying of 132 KV 630 Sq. mm. Single Core XLPE insulated Copper Cable ( 6+1 spare) including excavation of ground for min. 1.5 meter depth/as per the site requirement for trefoil arrangement and constraints in normal or hard soil Sand/brick installed, roads or any other site condition/underground conditions refiling, raining of earth etc. with suitable size RCC/HDPE pipes as cover on strategic locations for complete machanical protections of the Cable showing all danger sign etc. in the ground and above on the route including structure installation, earthing, bounding shielding size testing and commissioning in all respects. |
| 667 | Complete Route Survey, Check Survey including trial pits, Profiling, Alignment etc. including prepration of Tower schedule, pegmarking of locations etc. |
| 668 | Earth work excavation by mechanical means (hydraulic excavator) or manually means |
| 669 | Laying of 132 kV, 630 Sq.mm. XLPE Cable |
| 670 | Laying of XLPE Cable by HDD method including all works related to laying of HDPE pipe, XLPE cable, sheath bonding cable and earth countinuity cable (including 75 mm HDPE pipe) including excavation of all type of soil, backfilling, removing of extra excavated soil etc. complete in all respect including testing & commissioning of cable system. |
| 671 | Laying of XLPE Cable including all works related to laying of XLPE cable, sheath bonding cable and earth countinuity cable including excavation of all type of soil, trenching, sand filling, backfilling, removing of extra excavated soil, RCC slab, warning tape etc.and placing of HDPE pipe in open cut trench complete in all respect including testing & commissioning of cable system. |
| 672 | Approach Cable 48 Fibre |
| 673 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 674 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 675 | Providing and laying of position cement concrete or specified grade including the cost of centering, shuttering, material, forming, concreting, curing of water and cost of CC for 1:3:6 (excluding the cost of Reinforcement of slab). |
| 676 | Brick work with commen brunt clay F.P.S. brick of class designation 7.5 in foundation & plinth as per requirement cement mortar 1:4 ( 1 cement : 4 Coarse sand ), work also include plaster of walls of ratio 1:6 & curing of water. |
| 677 | Installation of straight through joint/Cross bonding Joint suitable for 132 kV 630 Sq.mm Cable |
| 678 | Installation polymer type outdoor termination kit suitable for 132 kV 630 Sq.mm Copper Cable (for monopole) including earthing etc. |
| 679 | Pipe earthing and connecting with 75x12 mm earth strip |
| 680 | Installation of Polymer Type Lightening Arrestor, Surge counter. |
| 681 | Erection of route marker @ 50 Meter interval |
| 682 | Installation of single phase link boxes |
| 683 | Installation of three phase link boxes |
| 684 | Laying of MS Flat 50x6 mm including cutting, bending and all welding work |
| 685 | Laying of MS round 40 mm including reiser cutting, bending and all welding work |
| 686 | Price Schedule-B (Erection) for ( Construction of 220 kV DC Overhead line from 400/220 kV Substation Puhana to proposed 220 kV Substation Raipur, Roorkee ) |
| 687 | Part - 1 |
| 688 | Survey |
| 689 | Detailed route Survey, Profiling, Alignment etc. including prepration of Tower schedule, Optimisation of tower locations etc and prepration of forest case (if any) complete in all respect |
| 690 | Check survey and final peg marking |
| 691 | Soil Investigation |
| 692 | Part - 2 |
| 693 | Setting of Stubs, inlcuding all foundation work but excluding the cost of concreting and excavation |
| 694 | B type Double Circuit (2o- 30o ) tower |
| 695 | C type Double Circuit (30o- 60o) tower |
| 696 | Foundation Bolt Setting for monopole, inlcuding all foundation work but excluding the cost of concreting and excavation |
| 697 | 220 kV D/C Cable termination Utility Monopole |
| 698 | Concrete for RCC type foundations including all material, shoring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for concrete (cost of supply of MS steel bar is not to be included) |
| 699 | M 20 (1:1.5:3) |
| 700 | M 10 (1:3:6) |
| 701 | Excavation of foundation pits including all earthwork, backfilling and levelling etc. |
| 702 | Super structure erection of various type of towers, tower part, tower extention (complete) with bolts & nuts and including all work above ground level excluding hoisting of insulators & fitting of danger plate, number plate, phase plate, circuit plate, anti climbing devices and bird guards, but including punching of bolts. |
| 703 | B type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 704 | C type tower including Erection for 3 mtr., 6 mtr. & 9 mtr. Body Extension |
| 705 | 220 kV D/C Cable termination Utility Monopole |
| 706 | Laying, Stringing, Tensioning, clamping, jointing etc. complete with Single ACSR Zebra conductor including hoisting of insulators and fitting of vibration dampers etc. for complete route of D/C Single Zebra. |
| 707 | Grounding work for Pipe type earthing including excavation and backfilling (Set of Two). |
| 708 | Tack welding on bolts and nuts on Ist section of towers |
| 709 | Fixing of tower accessories: |
| 710 | Danger plate |
| 711 | Number plate |
| 712 | Phase Plate (set of three) |
| 713 | Circuit Plate (set of two) |
| 714 | Anti-Climbing device |
| 715 | M.S. Steel bar for reinforcement |
| 716 | Installation of Avaition Items |
| 717 | Span markers |
| 718 | Obstruction lights (to be provided as per IS 5613) |
| 719 | 1 Medium + 2 low intensity |
| 720 | 1 Medium + 4 low intensity |
| 721 | Painting of Towers (As per IS:5613) |
| 722 | Erection of OPGW |
| 723 | Laying, Stringing Tensioning, clamping, jointing etc. complete with OPGW 48 Fibre - 220 kV and all required hardware such as Vibration damper, tension assemblies, earthing bond and downlead clamps as needed for a tension tower suitable for 48 Fibre OPGW on 220 kV lines |
| 724 | Reinforcing rod |
| 725 | Splice enclosure along with the downlead clamps as needed for 48 Fiber OPGW |
| 726 | Approach Cable 48 Fibre |
| 727 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 728 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 729 | Price Schedule-B (Erection) for (Construction of 220 kV DC line through Underground Cable from 400/220 kV Substation Puhana to proposed 220/132/33 kV Substation Raipur, Roorkee ) |
| 730 | Detailed Survey, Laying of 220 KV 1000 Sq. mm. Single Core XLPE insulated Copper Cable ( 6+1 spare) including excavation of ground for min. 1.9 meter depth/as per the site requirement for trefoil arrangement and constraints in normal or hard soil Sand/brick installed, roads or any other site condition/underground conditions refiling, raining of earth etc. with suitable size RCC/HDPE pipes as cover on strategic locations for complete machanical protections of the Cable showing all danger sign etc. in the ground and above on the route including structure installation, earthing, bounding shielding size testing and commissioning in all respects. |
| 731 | Complete Route Survey, Check Survey including trial pits, Profiling, Alignment etc. including prepration of Tower schedule, pegmarking of locations etc. |
| 732 | Earth work excavation by mechanical means (hydraulic excavator) or manually means |
| 733 | Laying of 220 kV, 1000 Sq.mm. XLPE Cable |
| 734 | Laying of XLPE Cable by HDD method including all works related to laying of HDPE pipe, XLPE cable, sheath bonding cable and earth countinuity cable (including 75 mm HDPE pipe)including excavation of all type of soil, backfilling, removing of extra excavated soil etc. complete in all respect including testing & commissioning of cable system. |
| 735 | Laying of XLPE Cable including all works related to laying of XLPE cable, sheath bonding cable and earth countinuity cable including excavation of all type of soil, trenching, sand filling, backfilling, removing of extra excavated soil, RCC slab, warning tape etc.and placing of HDPE pipe in open cut trench complete in all respect including testing & commissioning of cable system. |
| 736 | Approach Cable 48 Fibre |
| 737 | Junction Box (OPGW-Approach cable) along with downlead clamp for 48 Fibre |
| 738 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each). |
| 739 | Providing and laying of position cement concrete or specified grade including the cost of centering, shuttering, material, forming, concreting, curing of water and cost of CC for 1:3:6 (excluding the cost of Reinforcement of slab). |
| 740 | Brick work with commen brunt clay F.P.S. brick of class designation 7.5 in foundation & plinth as per requirement cement mortar 1:4 ( 1 cement : 4 Coarse sand ), work also include plaster of walls of ratio 1:6 & curing of water. |
| 741 | Installation of straight through joint/Cross bonding Joint suitable for 220 KV 1000 Sq.mm Cable |
| 742 | Installation polymer type outdoor termination kit suitable for 220 KV 1000 Sq.mm Copper Cable (for monopole) including earthing etc. |
| 743 | Pipe earthing and connecting with 50x6 mm earth strip |
| 744 | Installation of Polymer Type Lightening Arrestor, Surge counter. |
| 745 | Erection of route marker @ 50 Meter interval |
| 746 | Installation of single phase link boxes |
| 747 | Installation of three phase link boxes |
| 748 | Laying of MS Flat 50x6 mm including cutting, bending and all welding work |
| 749 | Laying of MS round 40 mm including reiser cutting, bending and all welding work |
| 750 | Price Schedule-B (Civil Works) for (220/132/33 KV Sub station, Raipur, Roorkee ) |
| 751 | Civil works as per technical specification |
| 752 | Buildings |
| 753 | Control room building (Plinth area to be measured). (It can be single or double storey building depending upon availability of space) including parking shed, rain water harvesting ponds, land scaping and park & plantation and ACP in face of control room building) |
| 754 | Store shed ( Plinth area to be measured) |
| 755 | Colony |
| 756 | Construction of residences |
| 757 | 3 nos Type IV Ground floor (Plinth area of each- 125 Sqm) |
| 758 | 4 nos Type III Ground floor (Plinth area of each- 79 Sqm) |
| 759 | 4 nos Type III First floor (Plinth area of each- 79 Sqm) |
| 760 | 8 nos Type II Ground floor (Plinth area of each- 57.70 Sqm) |
| 761 | 8 nos Type II First floor (Plinth area of each- 57.70 Sqm) |
| 762 | Residences devlopment work |
| 763 | Switch Yard |
| 764 | Construction of foundation of following structures including excavation and back filling of earth, CC/ RCC works including centering and shuttering, reinforcement, supply & fixing of bolts etc. complete. |
| 765 | 220 KV Tower |
| 766 | 220 KV Equipment |
| 767 | Circuit Breaker |
| 768 | Current Transformer (1 Ph.) with junction box |
| 769 | Lightening Arrestor |
| 770 | 1600A, 40 KA, isolator with one E/S |
| 771 | 1600A, 40 KA, isolator with two E/S |
| 772 | 1600A, 40KA, Isolator without E/S (Tandem) |
| 773 | Bus post Insulator |
| 774 | Support Insulator for Wave trap |
| 775 | 132 KV Tower |
| 776 | 132 KV Equipment |
| 777 | Circuit Breaker |
| 778 | Lightening Arrestor |
| 779 | 1250A, 40 KA, isolator with E/S |
| 780 | 1250A, 40 KA, isolator without E/S |
| 781 | 1250A, 40KA, Isolator without E/S (Tandem) |
| 782 | Bus post Insulator |
| 783 | 33 KV Tower |
| 784 | 33 KV Equipments |
| 785 | Circuit Breaker |
| 786 | Potential Transformer |
| 787 | Lighting Arrestor |
| 788 | Isolator Without E/S |
| 789 | Isolator With E/S |
| 790 | Bus post Insulator |
| 791 | Transformer |
| 792 | 160 MVA 220/132 KV |
| 793 | 80 MVA 132/33 KV |
| 794 | 630 KVA 33/0.4 KV |
| 795 | 400 KVA 33/0.4 KV |
| 796 | Fire Protection Wall between 160 MVA transformers |
| 797 | Fire Protection Wall between 80 MVA transformers |
| 798 | Construction of DG set plinth |
| 799 | RCC Cable trenches with trench covers ( all sections) including all type of crossing and all metallic work to support cables and trench covers. |
| 800 | 200 X 200mm size trench with minimum depth 200mm |
| 801 | 400 X 400mm size trench with minimum depth 400mm |
| 802 | 600 X 600mm size trench with minimum depth 600mm |
| 803 | 1000 X 1000mm size trench with minimum depth 1000mm |
| 804 | 2 x 1000x1000mm size trench with minimum depth 1000mm |
| 805 | Buried Cable Trenches |
| 806 | RCC Roads including all types of crossings |
| 807 | 1.80 metre wide |
| 808 | 3.75 metre wide |
| 809 | 5.00 metre wide |
| 810 | RCC Storm water drain including culverts, sumpwell, sump house and pumps etc. |
| 811 | Security fencing 3.6 mtr high along with gates and security room |
| 812 | Security fencing 3.6 mtr high along with gates including toe wall and retaining wall |
| 813 | Security Room(Approx. plinth area-32.00 sqm) |
| 814 | Switch yard turfing and antiweed treatment including leveling and dressing of area, PCC and gravels |
| 815 | Construction of tube well with a discharge capacity of 500 lpm with KSB make submersible pumping set of 350 lpm discharge with L&T make panel board including construction of RCC Over Head Water Tank of 50 Kl capacity,15 Mtr staging, including pump house, connecting pipe lines, valves etc complete to ensure proper water supply in building and substations area with one spare pumping set and panel board. |
| 816 | Land Development works |
| 817 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 818 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation, trenches, plinth, sides of foundation etc. complete for all lift. |
| 819 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 820 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 821 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 822 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 823 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 824 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars |
| 825 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 826 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 827 | Construction of colony and colony roads & drains, water supply mains, fencing for residences and associated land development works. |
| 828 | Construction of 3.75 m wide RCC road for colony |
| 829 | Construction of colony drains including all type of crossing |
| 830 | Fencing for residences |
| 831 | Water supply mains |
| 832 | RCC roads including all types of crossings |
| 833 | 5.00 metre wide RCC Connecting Road for colony |
| 834 | RCC Box type Culvert 2.0 M span |
| 835 | Construction of 3.0m high retaining cum boundary wall having RCC columns at 3.0m C/C and brick panels upto 2.4m from FGL and 600mm barbed wire fencing above these panels with 2 no. RCC bands at FGL and top, including required foundations and construction of gate |
| 836 | Price Schedule-B (Pile Foundation ) for (Construction of 03 No pile foundation for the work 132 KV Bhagwanpur-LSM line at 220 KV S/s Raipur, Roorkee) |
| 837 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 838 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 839 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts and wall etc. |
| 840 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 841 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 842 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 843 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 750 mm dia piles |
| 844 | Fixing of template for stub of tower in correct position, level and alignment including setting of stub supplied by the department free of cost department free of cost (NSI). |
| 845 | Price Schedule-B (Pile Foundation ) for (Construction of 5 No pile foundation for the work 220 KV Raipure-Puhana line at 220 KV S/s Raipur, Roorkee) |
| 846 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 847 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 848 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts and wall etc. |
| 849 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 850 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 851 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 852 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 750 mm dia piles |
| 853 | Fixing of template for stub of tower in correct position, level and alignment including setting of stub supplied by the department free of cost department free of cost (NSI). Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Construction of 220/132/33 KV AIS Substation Raipur (Bhagwanpur), Roorkee along with its associated transmission lines” Contract No: PTCUL/E-Tender/C&P-II/SS-24/2026-27 |
| 854 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) * Tender is of composite nature comprising of supply of goods and supply of services NOTE:- The bidder has to fill the GST AMOUNT on The green cells of AMOUNT COLOUM(4) ONLY. In case any discrepancy is observed in amount carried from BoQ1 & BoQ2 sheet as below, the value given in BoQ1 & BoQ2 sheet shall prevail. NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Particulars Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Pleas Enter ZERO Only AMOUNT VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 855 | Total Price Schedule-A (Supply) from BoQ1 sheet WITHOUT GST |
| 856 | Total Price Schedule-B ( Erection, Civil Works, Devlopment Works and Pile Foundation) from BoQ2 sheet WITHOUT GST |
| 857 | Add GST* Amount on (Total of Price Schedule-A + Total of Price Schedule-B above) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only |
AI Tender Summary
Tender Timeline
Nov 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 30 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 31 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender