Tender For Special Repairs/ Replacement Of Outgoing Lt Ug Cable, Lt Switch Gears And Connected Items In Md And Otm Accn At Naval Station Karanja
Tender Value
45.53 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
20 days left
EMD
91070
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs/ Replacement Of Outgoing Lt Ug Cable, Lt Switch Gears And Connected Items In Md And Otm Accn At Naval Station Karanja
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accommodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalized with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 Sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. |
| 2 | BOQ Serial Item No.1.00 Contd - The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle panel shall be inclusive of the following provisions, complete all as specified and directed by Engr-in-Charge:- (Location : At behind Aryabhat-03 and NWWA office)(A) INCOMING - (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 630 Amps – 01 No. Make : L&T/ABB/SIEMENS(B) OUTGOING- (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 400 Amps – 01 No. Make : L&T/ABB/SIEMENS (ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 315 Amps – 01 No. Make : L&T / ABB / SIEMENS (iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 200 Amps - 01 No. Make : L&T/ABB/SIEMENS (iv) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 125 Amps – 02 Nos. Make : L&T/ABB/SIEMENS(v) MCCB thermal & magnetic type, 4 pole, 415 volt, 35 kA breaking capacity adjustable thermal release of range 100 Amps- 02 Nos. Make : L&T/ABB/SIEMENS (vi) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vii) Current transformer of suitable ratio, Accuracy-5VA, Class-1. Make:- AE / NSDA / PRINZ (viii) Led indicators ribbed lens with trimmed collar - Red, Yellow and Blue - 1 Each, Make TEKNIK/SELECT/L&T (ix) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral. (x) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (xi) Foundation for the panel should provided with PCC 1:2:4, type B-1 (Using 20mm size graded stone aggregate) at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for incoming and outgoing cables. |
| 3 | M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accommodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalized with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 Sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos. shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. |
| 4 | BOQ Serial Item No.2.00 Contd - The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle panel shall be inclusive of the following provisions, complete all as specified and directed by Engr-in-Charge:-Location :- NRA office and in front of Mora Gate(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 400 Amps – 01 No., Make : L&T/ABB/SIEMENS(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 315 Amps – 01 No.Make : L&T/ABB/SIEMENS(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 200 Amps - 01 No. Make : L&T/ABB/SIEMENS (iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 125 Amps – 02 Nos. Make : L&T/ABB/SIEMENS(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking capacity adjustable thermal release range 100 Amps- 03 Nos. Make : L&T/ABB/SIEMENS (v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. Make:- AE/NSDA/PRINZ (vii) Led indicators ribbed lens with trimmed collar - Red, Yellow and Blue - 1 Each, Make- TEKNIK/SELECT/L&T (viii) Aluminium bus bar of Rating 800 Amp R-Y-B phases and neutral. (ix) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (x) Foundation for the panel should provided with PCC 1:2:4, type B-1 (Using 20mm size graded stone aggregate) at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for incoming and outgoing cables. |
| 5 | M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accommodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalized with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 Sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos. shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. |
| 6 | BOQ Serial Item No.3.00 Contd - The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle panel shall be inclusive of the following provisions, complete all as specified and directed by Engr-in-Charge:- Location : Near Maharana Pratap-04 and near Building No.-101 (A) INCOMING - (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 630 Amps – 01 No. Make : L&T/ABB/SIEMENS(B) OUTGOING- (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 400 Amps – 01 No. Make : L&T/ABB/SIEMENS (ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 315 Amps – 01 No. Make : L&T / ABB / SIEMENS, (iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 200 Amps - 02 Nos. Make : L&T/ABB/SIEMENS, (iv) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 125 Amps – 02 Nos. Make : L&T/ABB/SIEMENS(v) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking capacity adjustable thermal release range 100 Amps- 01 No. Make : L&T / ABB / SIEMENS, (vi) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vii) Current transformer of suitable ratio, Accuracy - 5VA, Class-1. Make:- AE/NSDA/PRINZ(viii) Led indicators ribbed lens with trimmed collar - Red, Yellow and Blue - 1 Each, Make- TEKNIK/SELECT/L&T, (ix) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral. (x) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (xi) Foundation for the panel should provided with PCC 1:2:4, type B-1 (Using 20mm size graded stone aggregate) at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for incoming and outgoing cables. |
| 7 | Supply & fixing, jointing, connecting & testing in trenches XLPE / PVC insulated PVC sheathed armoured cable heavy duty 1100 volts grade, aluminium conductor, laying in trenches / ducts of following sizes including taking out of old unserviceable cable cover & cable complete all as specified and directed:-(a). 3.5 core 35 Sqmm |
| 8 | (b). 3.5 core 50 Sqmm |
| 9 | (c). 3.5 core 70 Sqmm |
| 10 | (d). 3.5 core 95 Sqmm |
| 11 | (e). 3.5 core 120 Sqmm |
| 12 | (f). 3.5 core 150 Sqmm |
| 13 | (g). 3.5 core 240 Sqmm |
| 14 | (h). 3.5 core 300 Sqmm |
| 15 | Excavation in trenches for not exc 1.50m wide and n. exc. 1.50m depth and getting out in soft / loose soil including taking out faulty cable / cable, cable covers and GI pipe complete all as specified and directed. |
| 16 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 17 | Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point, complete all as specified and directed |
| 18 | M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and directed |
| 19 | Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed |
| 20 | Laying only un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed |
| 21 | M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 40 mm bore of pipe complete all as specified and directed |
| 22 | M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 50 mm bore of pipe complete all as specified and directed |
| 23 | M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 80 mm bore of pipe complete all as specified and directed |
| 24 | M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations, filling and mass concrete includings necessary form work complete all as specified and directed Please Enable Macros to View BoQ information |
| 25 | M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations, filling and mass concrete includings necessary form work complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender