Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58405716

Tender For Special Repairs/ Replacement Of Outgoing Lt Ug Cable, Lt Switch Gears And Connected Items In Md And Otm Accn At Naval Station Karanja

Issued by Statutory Bodies & Commissions/Committees · Raigad, Maharashtra
Tender Value
45.53 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
20 days left
EMD
91070
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs/ Replacement Of Outgoing Lt Ug Cable, Lt Switch Gears And Connected Items In Md And Otm Accn At Naval Station Karanja

BOQ

Name of Work:- SPECIAL REPAIRS/ REPLACEMENT OF OUTGOING LT UG CABLE, LT SWITCH GEARS AND CONNECTED ITEMS IN MD AND OTM ACCN AT NAVAL STATION KARANJA
Sl. No. Item Description
1M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accommodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalized with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 Sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made.
2BOQ Serial Item No.1.00 Contd - The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle panel shall be inclusive of the following provisions, complete all as specified and directed by Engr-in-Charge:- (Location : At behind Aryabhat-03 and NWWA office)(A) INCOMING - (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 630 Amps – 01 No. Make : L&T/ABB/SIEMENS(B) OUTGOING- (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 400 Amps – 01 No. Make : L&T/ABB/SIEMENS (ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 315 Amps – 01 No. Make : L&T / ABB / SIEMENS (iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 200 Amps - 01 No. Make : L&T/ABB/SIEMENS (iv) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 125 Amps – 02 Nos. Make : L&T/ABB/SIEMENS(v) MCCB thermal & magnetic type, 4 pole, 415 volt, 35 kA breaking capacity adjustable thermal release of range 100 Amps- 02 Nos. Make : L&T/ABB/SIEMENS (vi) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vii) Current transformer of suitable ratio, Accuracy-5VA, Class-1. Make:- AE / NSDA / PRINZ (viii) Led indicators ribbed lens with trimmed collar - Red, Yellow and Blue - 1 Each, Make TEKNIK/SELECT/L&T (ix) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral. (x) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (xi) Foundation for the panel should provided with PCC 1:2:4, type B-1 (Using 20mm size graded stone aggregate) at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for incoming and outgoing cables.
3M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accommodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalized with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 Sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos. shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made.
4BOQ Serial Item No.2.00 Contd - The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle panel shall be inclusive of the following provisions, complete all as specified and directed by Engr-in-Charge:-Location :- NRA office and in front of Mora Gate(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 400 Amps – 01 No., Make : L&T/ABB/SIEMENS(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 315 Amps – 01 No.Make : L&T/ABB/SIEMENS(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 200 Amps - 01 No. Make : L&T/ABB/SIEMENS (iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 125 Amps – 02 Nos. Make : L&T/ABB/SIEMENS(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking capacity adjustable thermal release range 100 Amps- 03 Nos. Make : L&T/ABB/SIEMENS (v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. Make:- AE/NSDA/PRINZ (vii) Led indicators ribbed lens with trimmed collar - Red, Yellow and Blue - 1 Each, Make- TEKNIK/SELECT/L&T (viii) Aluminium bus bar of Rating 800 Amp R-Y-B phases and neutral. (ix) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (x) Foundation for the panel should provided with PCC 1:2:4, type B-1 (Using 20mm size graded stone aggregate) at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for incoming and outgoing cables.
5M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accommodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalized with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 Sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos. shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made.
6BOQ Serial Item No.3.00 Contd - The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle panel shall be inclusive of the following provisions, complete all as specified and directed by Engr-in-Charge:- Location : Near Maharana Pratap-04 and near Building No.-101 (A) INCOMING - (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 630 Amps – 01 No. Make : L&T/ABB/SIEMENS(B) OUTGOING- (i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 400 Amps – 01 No. Make : L&T/ABB/SIEMENS (ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 315 Amps – 01 No. Make : L&T / ABB / SIEMENS, (iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 200 Amps - 02 Nos. Make : L&T/ABB/SIEMENS, (iv) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking capacity adjustable thermal release range 125 Amps – 02 Nos. Make : L&T/ABB/SIEMENS(v) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking capacity adjustable thermal release range 100 Amps- 01 No. Make : L&T / ABB / SIEMENS, (vi) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vii) Current transformer of suitable ratio, Accuracy - 5VA, Class-1. Make:- AE/NSDA/PRINZ(viii) Led indicators ribbed lens with trimmed collar - Red, Yellow and Blue - 1 Each, Make- TEKNIK/SELECT/L&T, (ix) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral. (x) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (xi) Foundation for the panel should provided with PCC 1:2:4, type B-1 (Using 20mm size graded stone aggregate) at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for incoming and outgoing cables.
7Supply & fixing, jointing, connecting & testing in trenches XLPE / PVC insulated PVC sheathed armoured cable heavy duty 1100 volts grade, aluminium conductor, laying in trenches / ducts of following sizes including taking out of old unserviceable cable cover & cable complete all as specified and directed:-(a). 3.5 core 35 Sqmm
8(b). 3.5 core 50 Sqmm
9(c). 3.5 core 70 Sqmm
10(d). 3.5 core 95 Sqmm
11(e). 3.5 core 120 Sqmm
12(f). 3.5 core 150 Sqmm
13(g). 3.5 core 240 Sqmm
14(h). 3.5 core 300 Sqmm
15Excavation in trenches for not exc 1.50m wide and n. exc. 1.50m depth and getting out in soft / loose soil including taking out faulty cable / cable, cable covers and GI pipe complete all as specified and directed.
16Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
17Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point, complete all as specified and directed
18M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and directed
19Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed
20Laying only un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed
21M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 40 mm bore of pipe complete all as specified and directed
22M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 50 mm bore of pipe complete all as specified and directed
23M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 80 mm bore of pipe complete all as specified and directed
24M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations, filling and mass concrete includings necessary form work complete all as specified and directed Please Enable Macros to View BoQ information
25M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations, filling and mass concrete includings necessary form work complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58405716
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.53 Lakhs
LAST DATE 28-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs/ Replacement Of Outgoing Lt Ug Cable, Lt Switch Gears And Connected Items In Md And Otm Accn At Naval Station Karanja
Basic Detail
Tender No 8428/E8
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 05 Nov 2026
Submission Date 28 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 45.53 Lakhs
Tender Fee 500
EMD 91070
Exemption Available
Document List
8428TenderDocs.pdf
b1bbe189-828d-41f8-9ed7-380b32e83176.html
BOQ_894669.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
pdf

8428TenderDocs.pdf

html

b1bbe189-828d-41f8-9ed7-380b32e83176.html

xls

BOQ_894669.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender